• 제목/요약/키워드: Two liquids

검색결과 163건 처리시간 0.034초

Lipase-catalyzed Transesterification in Several Reaction Systems: An Application of Room Temperature Ionic Liquids for Bi-phasic Production of n-Butyl Acetate

  • Park Suk-Chan;Chang Woo-Jin;Lee Sang-Mok;Kim Young-Jun;Koo Yoon-Mo
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • 제10권1호
    • /
    • pp.99-102
    • /
    • 2005
  • Organic solvents are widely used in biotransformation systems. There are many efforts to reduce the consumption of organic solvents because of their toxicity to the environment and human health. In recent years, several groups have started to explore novel organic solvents called room temperature ionic liquids in order to substitute conventional organic solvents. In this work, lipase-catalyzed transesterification in several uni- and bi-phasic systems was studied. Two representative hydrophobic ionic liquids based on 1-butyl-3-methylimidazolum coupled with hexafluorophosphate ([BMIM][$PF_6$]) and bis[{trifluoromethylsulfonyl} imide] ([BMIM] [$Tf_{2}N$]) were employed as reaction media for the transesterification of n-butanol. The commercial lipase, Novozym 435, was used for the transesterification reaction with vinyl acetate as an acyl donor. The conversion yield was increased around $10\%$ in a water/[BMIM][$Tf_{2}N$] bi-phasic system compared with that in a water/hexane system. A higher distribution of substrates into the water phase is believed to enhance the conversion yield in a water/[BMIM][$Tf_{2}N$] system. Partition coefficients of the substrates in the water/[BMIM][$Tf_{2}N$] bi-phasic system were higher than three times that found in the water/hexane system, while n-butyl acetate showed a similar distribution in both systems. Thus, RTILs appear to be a promising substitute of organic solvents in some biotransformation systems.

온도가 세척계의 표면장력에 미치는 영향(제1보) -세액의 표면장력 성분변화를 중심으로- (Effect of Temperature on the Surface Tensions in the Detergency System(I) -Change of Surface Tension Components of Washing Liquids-)

  • 채정희;김성련
    • 한국의류학회지
    • /
    • 제17권4호
    • /
    • pp.511-517
    • /
    • 1993
  • Changes of the surface and interface tension with temperature for washing liquids and alkanes were measured by FACE surface tensiometer. Using the extended Fowkes' equation, the dispersion and polar force components of the surface tension were estimated. The results were as follows : 1. The surface tensions of washing liquids and alkanes decreased almost linearly with the increase of temperature. 2. The interface tensions of 0.25% DBS/alkane increased slowly with the increase of temperature. In the case of nonionic surfactant solutions, however, the interface tensions with alkanes varied with the number of hydrophilic ethylene oxide(EO) groups. 3. Of the surface tension of water at $20^{\circ}C$, the dispersion force component was 25.3 dyn/cm and the polar force component was 47.8 dyn/cm. As the temperature increased, both the polar and dispersion force components decreased in a similar fashion. 4. The dispersion force component of surface tension of 0.25% DBS solution was 30.0 dyn/cm, and the polar force component was 2.2 dyn/cm at $20^{\circ}C$. The two components decreased with the increase of temperature. 5. As the temperature increased, the dispersion force component of surface tension decreased and the polar force component increased significantly for 0.25% NPPG-7.5EO solution. In the case of 025% NPPG-10EO, both the dispersion and polar force components decreased slowly, but the polar force component is expected to increase from $60^{\circ}C$. However, the polar force component of surface tension decreased with the increase of temperature for 025% NPPG-15EO solution, and at the temperature higher than $60^{\circ}C$ the surface tension is expected to be composed of only dispersion force component.

  • PDF

개방식 장치를 이용한 난연성-가연성 이성분계 혼합물(CCl4+o-Xylene and CCl4+p-Xylene)의 인화점 측정 (The Measurement of Flash Point for Unflammable-Flammable Binary Mixtures(CCl4+o-Xylene and CCl4+p-Xylene) Using Open Cup Tester)

  • 김창섭;이성진;하동명
    • 에너지공학
    • /
    • 제24권4호
    • /
    • pp.18-23
    • /
    • 2015
  • 인화점은 인화성에 따라 가연성 액체들을 분류하기 위해 사용된다. 인화점은 인화성 액체를 안전하게 저장, 취급 수송하기 위한 중요한 정보이다. Tag 개방식 장치를 이용하여 두 개의 이성분계 혼합물($CCl_4+o-xylene$ and $CCl_4+p-xylene$)의 인화점을 측정하였다. 또한 라울의 법칙, UNIQUAC 식, 경험식을 이용하여 인화점을 계산하여 그 값을 측정치와 비교하였다. 이 중 경험식에 의한 인화점 계산치가 가장 측정치를 잘 모사하였다.

Comparison of Pre-Stain Suspension Liquids in the Contrasting Ability of Neutralized Potassium Phosphotungstate for Negative Staining of Bacteria

  • Kim, Ki-Wooh;Jung, Woo-Kyung;Park, Yong-Ho
    • Journal of Microbiology and Biotechnology
    • /
    • 제18권11호
    • /
    • pp.1762-1767
    • /
    • 2008
  • Image contrast of whole bacteria was compared in Staphylococcus aureus and Escherichia coli depending on pre-stain suspension liquids by energy-filtering transmission electron microscopy. The two bacterial strains were suspended in three most commonly used liquids for negative staining (triple distilled water [DW], phosphate-buffered saline [PBS], and nutrient broth [NB]) and directly observed without staining or stained with neutralized potassium phosphotungstate (PTA), respectively. Even though in low contrast, unstained bacteria were observed owing to their inherent electron density and cell shape in zero-loss (elastic scattering) images. After being suspended in PBS, unstained bacteria appeared to have higher contrast and more refined periphery than DW-suspended ones, and extracellular appendage structures such as fimbriae and flagella could be discerned. The unstained bacteria appeared to be invariably surrounded with electron-lucent precipitates, possibly from PBS. As far as delineation of the structures, the combination of DW or PBS suspension with subsequent staining provided the most satisfactory results, as evidenced by the high contrast of bacterial morphology and appendage structures. However, after being suspended in NB and stained with PTA, bacteria often had too high contrast or poor staining, with electron-dense aggregates around the bacteria. These results suggest that suspension with concentrated organic aliquots including broth media before PTA staining could deteriorate image contrast, and should be used only in dilute form for visualizing bacterial morphology and appendage structures. Moreover the contrast enhancement of unstained bacteria by salt granules would be advantageous in demonstrating bacterial sorption of environmental particles like heavy metals, maintaining minimal contrast for cell imaging.

The competing roles of extensional viscosity and normal stress differences in complex flows of elastic liquids

  • Walters, K.;Tamaddon-Jahromi, H.R.;Webster, M.F.;Tome, M.F.;McKee, S.
    • Korea-Australia Rheology Journal
    • /
    • 제21권4호
    • /
    • pp.225-233
    • /
    • 2009
  • In various attempts to relate the behaviour of highly-elastic liquids in complex flows to their rheometrical behaviour, obvious candidates for study have been the variation of shear viscosity with shear rate, the two normal stress differences $N_1$ and $N_2$, especially $N_1$, and the extensional viscosity $\eta_E$. In this paper, we shall be mainly interested in 'constant-viscosity' Boger fluids, and, accordingly, we shall limit attention to $N_1$ and $\eta_E$. We shall concentrate on two important flows - axisymmetric contraction flow and "splashing" (particularly that which arises when a liquid drop falls onto the tree surface of the same liquid). Modern numerical techniques are employed to provide the theoretical predictions. It is shown that the two obvious manifestations of viscoelastic rheometrical behaviour can sometimes be opposing influences in determining flow characteristics. Specifically, in an axisymmetric contraction flow, high $\eta_E$ can retard the flow, whereas high $N_1$ can have the opposite effect. In the splashing experiment, high $\eta_E$ can certainly reduce the height of the so-called Worthington jet, thus confirming some early suggestions, but, again, other rheometrical influences can also have a role to play and the overall picture may not be as clear as it was once envisaged.

대학생들의 영어자음 인지 연구 (A Study of English Consonants Identified by College Students)

  • 양병곤
    • 음성과학
    • /
    • 제12권3호
    • /
    • pp.139-151
    • /
    • 2005
  • Previous studies have shown that Korean students have difficulty identifying some English consonants which are not in the Korean sound inventory. The aim of this study was to examine the accuracy rate of English consonants correctly identified by 130 college students in order to find out which English consonants were difficult for the students to perceive. The subject's task was to identify one of the minimal pairs played in a quiet laboratory classroom. 100 minimal pairs consisted of syllables with various onsets or codas: stops, fricatives, affricates, liquids and nasals. Results were as follows: First, the average score of the English major group was significantly higher than that of the non-English major group. Second, there was a similar distribution in the rank order of minimal pairs sorted by the accuracy rate between the two groups. Third, the accuracy rate systematically decreased as each score range decreased. Fourth, the students showed higher accuracy in the perception of liquids than that of the stop-fricative contrast. Fifth, the accuracy score in onset position was higher than in coda position. Finally, the students still had problem telling voiced consonants from voiceless ones, especially in coda position. It would be desirable to extend the present research to middle or high school students to fundamentally resolve those listening problems.

  • PDF

과냉수에서의 증기응축제트에 대한 해석적 연구 (An Analytical Study on the Condensation of Submerged Vapor Jets in Subcooled Liquids)

  • 김기웅;이계복;김환열
    • 에너지공학
    • /
    • 제8권2호
    • /
    • pp.333-340
    • /
    • 1999
  • 과냉수에서의 난류 증기응축 제트에 대한 수치해석 연구가 수행되었다. 증기와 과냉수 사이에 국부 균질유동을 가정하고 난류 특성은 난류 확산화염에서 사용되는 $textsc{k}$-$\varepsilon$-g 모델을 사용하여 증기응축 유동 현상에 대한 물리적 모델을 제안하였다. 즉, 난류는 난류 운동 에너지와 운동 에너지 소멸률로 모사되고 증기와 과냉수의 혼합률비에 대한 평균값과 변동량에 대한 미분 방정식을 추가하여 직접 풀고 혼합률비에 확률분포 함수를 적용하여 열역학 변수의 평균값을 구한다. 증기 질량 유속, 과냉수 온도와 노즐 직경을 변화시키며 증기응축제트의 특성을 해석하였다. 본 해석에 사용된 모델을 평가하기 위해 기존의 실험 데이터를 사용해서 수치해석 결과와 실험치를 비교하여 만족할 만한 결과를 얻었다.

  • PDF

용융 고분자간의 계면장력에 대한 이론적 예측 (Theoretical Estimation of Interfacial Tension between Molten Polymers)

  • 오영기;;전무식
    • 대한화학회지
    • /
    • 제23권4호
    • /
    • pp.210-216
    • /
    • 1979
  • 특성구조액체이론(significant structure theory of liquids)에 입각하여, 섞이지 않는 두 용융 고분자중에서의 계면장력을 예측하는 간단한 계산방법을 연구하였다. 접착에너지는 응집에너지들의 기하평균과 보정항의 곱으로 표시되며, 응집에너지는 고분자 사슬의 격자상을 가정하므로써 계산된다. 계면장력올 계산함에 있어서 고분자사슬의 구성요소간 분산력(dispersion force) 외에 극성력(poIar force)를 포함시켜야 함이 확인되었다.

  • PDF

비이온계 계면활성제 수용액이 PET직물의 습윤특성에 미치는 영향 제1보 : Span 20과 Tween 20의 혼합계와 희석계 (Effect of Nonionic Surfactant Solutions on Wetting and Absorbancy of PET Fabric 1. Mixtures and Dilutions of Span 20 and Tween 20)

  • 김천희
    • 한국의류학회지
    • /
    • 제27권9_10호
    • /
    • pp.1153-1159
    • /
    • 2003
  • The effects of changing aqueous solution properties by nonionic surfactants on wetting behavior and water retention properies of hydrophobic PET (polyethylene terephthalate) fabric were reported. The aqueous solution properties were diversified by mixing and diluting two nonionic surfactants, i.e., sorbitan monolaurate (Span 20) and polyoxyethylene(20) sorbitan monolaurate (Tween 20). The surface wetting properties ($cos{\theta}$) of PET fabric were greatly improved by adding $10^{-1}g/dl$ Tween 20 and further improved by mixing Span 20 to the system. The water retention properties (W) of PET fabric were also greatly increased by addition of $10^{-1}g/dl$ Tween 20. In diluted surfactant systems, the $cos{\theta}'s$ were increased with decreasing surface tension of aqueous liquids. The ratios of aqueous liquid retained in the pore structure to liquid retention capacity (W/H) were also increased with decreasing surface tension, however, W/H values were dramatically increased right after critical micelle concentration (cmc). The existence of micelles was important for the retention of aqueous liquids in the fabric. The critical surface tension of PET fabric used was found to be 28.7dyne/cm.

Development of Electrochemical Processes for Aluminium-Based Coatings for Fusion Applications

  • Konys, J.
    • Corrosion Science and Technology
    • /
    • 제15권6호
    • /
    • pp.314-319
    • /
    • 2016
  • Reduced activation ferritic-martensitic steels (RAFM) are envisaged in future fusion technology as structural material which will be in direct contact with a flowing liquid lead-lithium melt, serving as breeder material. Aluminium-based coatings had proven their ability to protect the structural material from corrosion attack in flowing Pb-15.7Li and to reduce tritium permeation into the coolant, significantly. Coming from scales produced by hot dipping aluminization (HDA), the development of electrochemical-based processes to produce well-defined aluminium-based coatings on RAFM steels gained increased attention in research during the last years. Two different electrochemical processes are described in this paper: The first one, referred to as ECA, is based on the electrodeposition of aluminium from volatile, metal-organic electrolytes. The other process called ECX is based on ionic liquids. All three processes exhibit specific characteristics, for example in the field of processability, control of coating thicknesses (low activation criteria) and heat treatment behavior. The aim of this article is to compare these different coating processes critically, whereby the focus is on the comparison of ECA and ECX processes. New results for ECX will be presented and occurring development needs for the future will be discussed.