• Title/Summary/Keyword: Two liquids

Search Result 163, Processing Time 0.032 seconds

Korean and Japanese EFL Learners' AV Benefit for the Perception of the Liquid Contrast in English (한국인 및 일본인 영어학습자의 유음 차이 지각에 미치는 시각/청각 효과)

  • Chung, Hyun-Song
    • MALSORI
    • /
    • no.60
    • /
    • pp.1-11
    • /
    • 2006
  • This paper investigated AV benefit of Korean and Japanese EFL learners' perception of the liquid contrast in English. In a perception experiment, the two English consonants /l/ and /r/ were embedded in initial and medial position in nonsense words in the context of the vowels /i, a, u/. Singletons and clusters were included in the speech material. Audio and video recordings were made using a total of 108 items. The items were presented to Korean and Japanese learners of English in three conditions: audio-alone (A), visual-alone (V) and audio-visual presentation (AV). The results showed that there was no evidence of AV benefit for the perception of the /l/-/r/ contrast for either Korean or Japanese learners of English. The results suggest that increasing auditory proficiency in identifying a non-native contrast is linked with an increasing proficiency in using visual cues to the contrast.

  • PDF

유기물 분리용 투과증발막

  • 박현채
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1996.03a
    • /
    • pp.69-90
    • /
    • 1996
  • In the chemical industry, in the pharmaceutical industry, and in a number of other industries separation processes are necessary to separate and purify products and raw materials [1,2]. Separation processes are also widely used in other applications such as in recycling valuable materials from waste streams. Unit operations for separation processes can be classified in phase separation techniques and component separation techniques based on the nature of the feed mixtures to be separated. The former techniques are used for the separation of heterogeneous mixtures, in which the feed is already present in two or more separated phases on a micro-scale. The latter are suitable for the separation of homogeneous mixtures such as gaseous mixtures and mixtures of completely miscible liquids. tn these cases the separation into individual components is generally achieved by utilizing the differences in physico-chemical properties of components, and is much more difficult compared to phase separation techniques. Separation processes such as distillation, evaporation, liquid-liquid extraction, and crystallization belong to this class.

  • PDF

Study on the Manufacturing Process of Artemisia asiatica Carbonized Organic Solution(Wormwood Acetic Acid) by Development of Carbonize Equipment (탄화장치 개발에 의한 쑥(Artemisia asiatica) 탄화 유기용액(쑥초액) 제조에 관한 연구)

  • Ryu, Soung-Ryual
    • Journal of Integrative Natural Science
    • /
    • v.4 no.1
    • /
    • pp.15-22
    • /
    • 2011
  • In this study, liquid with carbonized artemisia was developed for the first time that can be used as food additives and outside medicinal agents by burning artemisia species such as Artemisia dubia wall, Artemisia capillaris Thunb, Artemisia montana (Nakai) Pamp), Artemisia keiskeana Miq, Leonurus Japonicus Houtt. etc. In addition, edibility of recovered liquid with carbonized artemisia was verified by comparing the contents according to each ingredient with common refined pyroligneous liquid through the analysis of 9 kinds of organic acid by the species of artemisia, methanol and ethanol. Besides, the result of antimicrobial activities on six kinds of food spoilage and food poisoning bacteria observed by paper disc method for liquid with carbonized artemisia indicated that those two liquids showed strong antimicrobial. At the concentration of 1.5 mg/disc, clear zone for S. sonnei and S. aureus, L. monocytogenes was 13~16 mm, and they showed stronger antimicrobial activities than other strain.

TRANSIENT CHF PHENOMENA DUE TO EXPONENTIALLY INCREASING HEAT INPUTS

  • Park, Jong-Doc;Fukuda, Katsuya;Liu, Qiusheng
    • Nuclear Engineering and Technology
    • /
    • v.41 no.9
    • /
    • pp.1205-1214
    • /
    • 2009
  • The critical heat flux (CHF) levels that occurred due to exponential heat inputs for varying periods to a 1.0-mm diameter horizontal cylinder immersed in various liquids were measured to develop an extended database on the effect of high subcoolings for quasi-steady-state and transient maximum heat fluxes. Two main mechanisms of CHF were found. One mechanism is due to the time lag of the hydrodynamic instability (HI) which starts at steady-state CHF upon fully developed nucleate boiling, and the other mechanism is due to the explosive process of heterogeneous spontaneous nucleation (HSN) which occurs at a certain HSN superheat in originally flooded cavities on the cylinder surface. Steady-state CHFs were divided into three regions for lower, intermediate and higher subcooling at pressures resulting from HI, transition and HSN, respectively. HSN consistently occurred in the transient boiling CHF conditions that correspond to a short period. It was also found that the transient boiling CHFs gradually increased, then rapidly decreased and finally increased again as the period became shorter.

Thin CNTs nanoliquid film development over a rough rotating disk

  • Swatilekha Nag;Susanta Maity;Sanjeev K. Metya
    • Advances in nano research
    • /
    • v.15 no.2
    • /
    • pp.91-104
    • /
    • 2023
  • Development of thin carbon nanotubes (CNTs) nanoliquid film over the rough surface of a horizontal rotating disk is investigated by considering symmetric roughness either along the azimuthal or radial directions. The disk surface is either heated or cooled axisymmetrically from below. The effects of single-walled carbon nanotubes (SWCNTs), multi-walled carbon nanotubes (MWCNTs) are analyzed on the film thinning process with different types of base liquids. Closed form solutions for velocity and temperature field are obtained for small values of Reynolds number whereas the numerical solution is derived for moderate values of Reynolds number. It is found that fluid retention / depletion takes place when the roughness is symmetric along the azimuthal / radial directions. It is also seen that the film thinning rate enhances for MWCNTs compare to SWCNTs. Further it is found that two different heat transfer regions exits within the flow domain depending on the fact that heat is transferred from disk to liquid film and vice-versa.

A Study of the Reverse Engineering of a Two-Stage Impeller-Submerged Pump for Cryogenic Fluids (극저온용 2단 임펠러 액중펌프 역설계에 관한 연구)

  • Kweon, Byung Soo;Yi, Chung-Seob;Lee, Chi-Woo
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.16 no.3
    • /
    • pp.9-15
    • /
    • 2017
  • This study represents basic research for the development of submerged pump technology applicable to transfer and storage of a cryogenic liquids. Its purpose is to secure baseline design data by applying reverse engineering to the process of developing a submerged cryogenic pump. The two-stage model included in the ARTICK Series LNG Submerged Pump produced by Vanzetti of Italy was selected for analysis for development of a localized product, and was disassembled for reverse engineering. The pump was disassembled after analyzing its processing/assembly characteristics such as shrinkage of fittings. In addition, the materials used in manufacturing of the main components were analyzed, and the ingredients were confirmed. As a result, a design drawing for each component required for product development was secured via foundational design, and a test product was manufactured by maximizing the application of appropriate domestic technologies.

A Yew Technique for Infrared Spectroscopy using Polyethylene Film Cell (Polyethylene Film을 利用한 赤外線分光分析用 Cell)

  • Sung, Chwa-Kyung;Noh, Ick-Sam
    • Journal of the Korean Chemical Society
    • /
    • v.7 no.1
    • /
    • pp.58-64
    • /
    • 1963
  • Authors propose a new technique using polyethylene film instead of sodium chloride window as a cell material. Nujol mulls, liquids and aqueous solutions are sandwitched between two pieces of polyethylene film which are held between cardboards. Ordinary lead or stainless steel spacers could be used if exact cell thickness is desired. A more elaborate cell can be assembled by injecting samples between two pieces of polyethylene film which are placed between sodium chloride windows of ordinary demountable liquid cell. The absorption bands due to polyethylene and Nujol are compensated by placing the polyethylene film of suitable thickness in the reference beam. The absorption bands due to solvents such as water can also be compensated by the polyethylene film cell sandwitched solvent of suitable thickness in the reference beam. This method would be a simple new technique. Especially this technique may offer a new helpful way for the investigation of the state of substances in aqueous system. Using this technique, authors have observed the appearance of an absorption bands at 3.2 micron, in the spectrum of phenol in aqueous solution, that is absent in the spectrum of phenol in benzene solution. The same absorption band also has been observed in the spectra of aqueous formaldehyde solution and aqueous polyvinyl alcohol solution, where the absorption bands due to polyethylene and water are compensated. Although it may be regarded that this absorption band is related to the intermolecular interaction between water and the solute having OH group, that is hydrogen bonding. The exact assignment of this absorption band is out of this work.

  • PDF

A study on the acoustic scalings of cavitation noise in an orifice configuration and a constant flow control valve (오리피스 구조내에서 발생한 공동소음의 음향학적 스케일링에 관한 연구)

  • Lee, J. H.;Lee, S.;Yoo, S. H.
    • 유체기계공업학회:학술대회논문집
    • /
    • 1999.12a
    • /
    • pp.81-89
    • /
    • 1999
  • The major source of noise in the process of transporting liquids is related to the cavitation phenomenon. The control valve noise is mostly dominated by bubble dynamics under cavitating conditions. In this investigation, an orifice configuration is set-up to correlate its flow-field and acoustic signatures with those from a control valve device. The performance and noise characteristics form the orifice configuration in anechoic surroundings were measured to reveal the noise sources depending on pressure differences across the orifice configuration. The sound powers from the orifice configuration are effectively normalized using proposed scaling parameters. Flow-excited dynamic systems for which there is no strong coupling between the flow and the system response can be described using a linear source-filter model. On this assumption, the normalized sound powers can be decomposed of noise source function and a response function. To find noise sources, pressure spectra measured over a range of pressure differences are transformed into the product of two non-dimensional frequency function : $P_{ss}(He,f_{ca},x/D) = F(f_{ca})\;G(He,x/D)$. This scheme of finding noise sources is shown to be applicable to the cavitation noise from the control valve effectively Two kinds of cavitating modes based on our experimental data are found and discussed.

  • PDF

Laboratory investigations on the effects of acid attack on concrete containing portland cement partially replaced with ambient-cured alkali-activated binders

  • Ramagiri, Kruthi K.;Patil, Swaraj;Mundra, Harsh;Kar, Arkamitra
    • Advances in concrete construction
    • /
    • v.10 no.3
    • /
    • pp.221-236
    • /
    • 2020
  • To reduce the CO2 emissions associated with the manufacture of portland cement (PC), an efficient alternative like an alkali-activated binder (AAB) is the requirement of the industry. To promote the use of AAB in construction activities, a practically implementable mix proportion is required. Owing to the several raw ingredients of AAB concrete and their associated uncertainties, partial replacement of PC by AAB may be adopted instead of complete replacement as per industrial requirements. Hence, the present study aims to determine an optimal proportion for partial replacement of PC with AAB and recommend a technique for it based on site conditions. Three modes of partial replacement are followed: combining all the dry ingredients for AAB and PC followed by the addition of the requisite liquids (PAM); combining the PC and the AAB concrete in two horizontal layers (PAH); and two vertical layers (PAV). 28-day old specimens are exposed to 10% v/v solutions of HCl, H2SO4, and HNO3 to evaluate changes in mechanical, physical, and microstructural characteristics through compressive strength, corrosion depth, and microscopy. Based on deterioration in strength and integrity, PAH or PAV can be adopted in absence of acid attack, whereas PAM is recommended in presence of acid attack.

Relationship between Interfacial Tension and Solubility of Diesel Fuel in Surfactant Solutions (계면활성제용액-경유 간 계면장력과 용해도 상관관계 연구)

  • Jeong, Seung-Woo;Hur, Jeong-Hyun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.35 no.1
    • /
    • pp.70-73
    • /
    • 2013
  • Solubility of oil contaminants in surfactant solutions plays an important role in selecting a suitable surfactant type for soil remediation. Solubility measurement procedures consist of making an equilibrium between surfactant solution and oil, solvent extraction using dichloromethane, and condensation for gas chromatography analysis. Solubility measurement requires time consumption and lots of materials. Interfacial tension is the contracting force between two immiscible liquids, surfactant solution and oil, and also closely related to solubility of oil. This study established a relationship between the interfacial tension and solubility of diesel fuel in surfactant solution and suggested a quick method to estimate solubility of oil in a surfactant solution by measuring its interfacial tension. The results of this study showed that the solubility of diesel fuel in surfactant solution was exponentially increased by decreasing the interfacial tension between two immiscible liquids. The solubility of diesel fuel was significantly increased under the interfacial tension conditions below 1 dyne/cm, while the solubility change was not apparent under the interfacial tension conditions beyond 5 dyne/cm. Interfacial tension measurements may allow us to quickly select an efficient surfactant and its concentration for soil remediation.