• Title/Summary/Keyword: Two droplets

Search Result 298, Processing Time 0.026 seconds

Performance Evaluation of an Electrohydrodynamic Spray Nozzle for Regeneration of Particulate Matter on Diesel Particulate Filter (경유차 입자상물질 저감필터(DPF) 재생용 전기수력학적 연료 후분사 노즐의 미립화 특성 평가 및 수치해석을 이용한 액적 입경별 연소 특성 평가)

  • Jeong, Seonghun;Park, Sung-Eun;Kim, Min-Jung;Cho, Hyung-Jei;Hwang, Jungho
    • Particle and aerosol research
    • /
    • v.8 no.2
    • /
    • pp.55-68
    • /
    • 2012
  • Particulate matters (PM) which are collected into a diesel particulate filter (DPF) system have to be periodically removed by thermal oxidation. In this report, we fabricated an electrohydrodynamic-assisted pressure-swirl nozzle to spray diesel droplets finer. Atomization performance of the nozzle was evaluated using both experimental and numerical methods. Two types of nozzle designs, the charge induction type and the charge injection type, were tested. While the former generated diesel droplets of $400\;{\mu}m$ at an applied electric potential over 10 kV, the latter presented the droplets smaller than $23\;{\mu}m$ at an applied electric potential of 8 kV. The numerical simulation results showed that the reduced size of droplets caused higher evaporation of droplets and therefore the increased temperature, which would eventually increase the regeneration performance of the DPF system.

Ruptured Spinal Dermoid Cysts with Lipid Droplets into the Syrinx Cavity : Reports of Fourteen Cases

  • Cheng, Cheng;Li, Rong;Gao, Haihao;Tao, Benzhang;Wang, Hui;Sun, Mengchun;Gao, Gan;Wang, Jianzhen;Shang, Aijia
    • Journal of Korean Neurosurgical Society
    • /
    • v.65 no.3
    • /
    • pp.430-438
    • /
    • 2022
  • Objective : Dermoid cysts are uncommon in spinal cord tumors, and the phenomenon of their spontaneous rupture into the syrinx cavity is quite rare. We aimed to analyze the imaging characteristics and etiologies, and propose some surgical strategies, for this uncommon phenomenon. Methods : We retrospectively reviewed 14 cases with spinal dermoid cysts that ruptured into the cervical and thoracic syrinx cavity. There were six male and eight female cases, aged 21 to 46 years, who had lipid droplets in the syrinx cavity from C1 to L3. The dermoid cysts were always located at the conus. Based on patients' complaints, clinical manifestations, and imaging results, we adopted tumor excision and/or syrinx cavity aspiration in one stage or multiple stages. Results : Three patients had only a syrinx cavity aspiration surgery due to a history of dermoid cyst excision. Eight patients had dermoid cyst resection and syrinx cavity aspiration in one stage. One patient was operated upon in two stages due to the development of new symptoms at nine months follow-up. Two patients underwent only tumor resection since they did not show similar symptoms or signs caused by the cervicothoracic syrinx. The axial magnetic resonance imaging indicated that the lipid droplets were always not at the center but were eccentric. The clinical effect was satisfactory during the follow-up period in this group. Conclusion : The lipid droplets filled the spinal syrinx cavity, not entirely confined to the central canal. Based on the chief complaints and associated signs, we adopted different surgical strategies and had satisfactory clinical results.

Two-Side Holography System for the Measurements of Spray Characteristics (양 방향 홀로그래피를 이용한 분무 특성 해석 시스템)

  • Choo, Yeon-Jun;Kang, Bo-Seon
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.1755-1760
    • /
    • 2004
  • The holographic velocimetry system has a significant potential for the measurements of three dimensional velocities of particles. In this study, orthogonal two-side holography system was developed to obtain three dimensional velocities and sizes of spray droplets. To get high quality of reconstructed images, singe-exposure holography at two time moments and two orthogonal sides was adopted instead of multi-exposure, single-side holography. From three dimensional positions of droplets determined by reconstruction and image processing system, the three dimensional velocities and sizes of each droplet was extracted using the PTV algorithm. To determine the position of particles in the optical axis, a new focusing parameter was introduced based on the correlation between two droplet images at the same distance. The measured results by holography system were compared with those by the PDPA.

  • PDF

Microexplosive Vaporization of Miscible Binary Fuel Droplets (미세폭발을 가진 혼화 이성분 연료 액적의 증발 현상)

  • Ghassemi, Hojat;Baek, Seung-Wook;Khan, Qasim Sarwar
    • 한국연소학회:학술대회논문집
    • /
    • 2005.10a
    • /
    • pp.120-131
    • /
    • 2005
  • The evaporation characteristics of single and multicomponent droplets hanging at the tip of a quartz fiber are studied experimentally at the different environmental conditions under normal gravity. Heptane and Hexadecane are selected as two fuels with different evaporation rates and boiling temperatures. At the first step, the evaporation of single component droplet of both fuels has been examined separately. At the next step the evaporation of several blends of these two fuels, as a binary component droplet, has been studied. The temperature and pressure range is selected between 400 and 700 $^{\circ}C$, and 0.1 and 2.5 MPa, respectively. High temperature environment has been provided by a falling electrical furnace. The initial diameter of droplet was in range of 1.1 and 1.3 mm. The evaporation process was recorded by a high speed CCD camera. The results of binary droplet evaporation show the three staged evaporation. In the the first stage the more volatile component evaporates. The droplet temperature rises after an almost non evaporating period and in the third stage a quasi linear evaporation takes place. The evaporation of the binary droplet at low pressure is accompanied with bubble formation and droplet fragmentation and leads to incomplete microexplosion. The component concentration affects the evaporation behavior of the first two stages. The bubble formation and droplet distortion does not appear at high environment pressure. Nomenclature

  • PDF

Vaporizing Characteristics of Spray from Two Different GDI Injectors (분무각이 다른 GDI인젝터에 대한 증발특성)

  • Choe, Dong-Seok;Kim, Deok-Jul
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.5
    • /
    • pp.688-696
    • /
    • 2001
  • Vaporizing characteristics of two GDI injectors with different spray angles were investigated using exciplex fluorescence method. Injector I has narrower spray angle, while injector II has wider one. The exciplex system of fluorobenzene and DEMA in a non-fluorescing base fuel of hexane was employed. In quantifying concentration of fuel vapor, quenching of concentration and temperature was corrected. Droplet size and velocity were also measured by PDPA under non-vaporizing condition. From obtaining the images of liquid and vapor phases, vaporizing GDI sprays could be divided as two regions: cone and mixing regions. For injector I, vortex region was not developed. High concentration of fuel vapor due to vaporization of many fine droplets was distributed near the spray axis. For injector II, droplets with the diameter of about 10 $\mu$m were distributed in the vortex region. The vortex region had high concentration of fuel vapor due to vaporization of these droplets. Particularly, higher and lower concentrations of fuel vapor were balanced at 2ms after the start of injection for injector II.

Numerical Study on the Interaction of Liquid Fuel Droplets in the Reacting Flow Field (연소 유동장 내 액체 연료 액적간의 상호작용에 대한 수치적 연구)

  • Cho, Chong-Pyo;Kim, Ho-Young;Park, Sim-Soo
    • 한국연소학회:학술대회논문집
    • /
    • 2001.11a
    • /
    • pp.63-71
    • /
    • 2001
  • The objective of this work is to elucidate the details of two key factors dominating the droplet buring behavior in sprays : droplet-droplet interaction and convective flow. The combustion of a one-dimensional linear droplet array with a convective flow has been studied. A one-step, second order model was employed to simulate the chemical reaction in the combustion process. Results for droplet arrays burning at two Reynolds numbers, 50 and 100, two horizontal droplet spacings, 5 and 11 radii, and two vertical droplet spacing, 2 and 4 radii, were obtained. The results indicate the droplet burning behavior is affected by Reynolds number, droplet-droplet spacing, and the relative location of droplets in the array. Droplet-droplet interaction was found to be strong for arrays with smaller droplet spacing.

  • PDF

NUMERICAL SIMULATION OF A TRANSONIC AIRFOIL IN THE CLOUD WITH THE DROPLET-LADEN INVISCID AIR FLOW MODEL (액적이 있는 비점성 공기유동 모델을 이용한 구름속의 천음속 에어포일 수치해석)

  • Yeom, G.S.;Chang, K.S.;Baek, S.W.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.291-293
    • /
    • 2011
  • In this paper, the problem of transonic aerodynamic characteristics of a NACA0012 airfoil is numerically investigated in the inviscid gas-droplet two-phase flow with the compressible two-fluid model. In the present study, the airfoil flight in the cloud is simulated by taking account of the viscous drag of the droplets, the heat transfer, the phase change, and the droplet fragmentation The two-fluid equation system is solved by the fractional-step method and the WAF-HIL scheme. The effects of size and volume fraction of the droplets on the flow characteristics of the airfoil in the cloud are elaborated and discussed.

  • PDF

An Experimental Study on Characteristics of Droplet Generation by Electrospraying for Highly Viscous Liquids (정전분무에 의한 고점성 액체의 액적 생성 특성에 관한 실험적 연구)

  • Kim, Sang-Su;Gu, Bon-Gi
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.26 no.4
    • /
    • pp.604-613
    • /
    • 2002
  • Generation characteristics of electrospray droplets for highly viscous liquid have been investigated by measuring size distributions of droplets emitted from the Taylor cone using glycerol solutions with various conductivities. Because of very small volatility of glycerol, droplet sizes can be measured by an aerodynamic size spectrometer (TSI Aerosizer DSP) with negligible evaporation of droplets. For highly conducting and viscous liquid, the sizes of the droplets electrosprayed from the Taylor cone are found to be relatively insensitive to applied voltages and the electrosprays assisted by the corona discharge call produce monodisperse droplets as long as the corona intensity is not too high. Near the minimum flow rate where a liquid cone is stable, the spray tends to consist of a one -peak monodisperse distribution of drop lets. However, at high flow rates, the spray bifurcates into bimodal distributions, which are consistent with the result of the previous study for less viscous liquids than our liquids. For liquid flow rates (Q) below 1 nl/s, the measured droplet diameters by the aerosizer are in the range of 0.30 to 1.2 ${\mu}{\textrm}{m}$ for the glycerol solutions. The diameters of monodisperse droplets scale approximately with $r^*=Q_$\tau$(Q$\tau$){^1/3}$ where $r^*$ is a characteristic length and $\tau$is the electrical relaxation time of the fluid. However, when compared with several represe ntative scaling laws, the droplet diameters are two to six factors greater than those predicted by the scaling laws. This may be closely related to the combined effect of the much higher viscosity and the electrical charge on the jet breakup of glycerol so solution.

Atomization of Liquid Via a Combined System of Air Pressure and Electric Field (공기 압력과 전기장이 접목된 액적 분무에 관한 연구)

  • Hwang, Sangyeon;Seong, Baekhoon;Byun, Doyoung
    • Journal of the Korean Society of Visualization
    • /
    • v.12 no.2
    • /
    • pp.9-12
    • /
    • 2014
  • Conventional electrospray and air spray methods have the vulnerabilities of limited flow rate (throughput) and droplet size, respectively. Since high throughput with uniform size of droplet is required for various applications, an improved technique should be adopted. Here, we report a combined system of an air pressure and an electric field and evaluate the atomization performance of it. The air flow allowed applying high flow rate range and the electric field reinforced the atomization process to generate fine droplets. A correlation between two forces was investigated by comparing the droplet produced by each method. The atomized droplets were measured and visualized by image processing and a particle image velocimetry (PIV). The quantitative results were achieved from the parametric space and the effect of both forces was analyzed. The motion of charged droplets followed the outer electric field rather than the complex vortex in the shear layer so that the droplets accelerated directly toward the grounded collector.

Coverage Distribution of Blasted Droplets by an Orchard Sprayer (과수방제기 살포입자의 도포율 분포특성)

  • 구영모;김상헌;신범수
    • Journal of Biosystems Engineering
    • /
    • v.26 no.4
    • /
    • pp.355-362
    • /
    • 2001
  • Uniform application of agri-chemicals will improve orchard pest management. An air-blast(orchard) sprayer designed for vineyards has been used: however, few research on the uniformity and coverage of the sprays has been reported. Distributions of spray coverage were measured with artificial targets and analyzed to enhance the efficiency of spray application. A structure was built to place water sensitive papers, sampling spray droplets blasted from the orchard sprayer. The sampling cards were collected from five directions at three distances (2.5, 3.0 and 3.5m) for two fan speeds (2,075 and 3,031 rpm), and analyzed using an image analysis system. The distribution of the coverage percent area did not follow the wind velocity pattern. The coverage by the low fan speed was more uniform and higher than that by the higher fan speed. The coverage percent area decreased with an increase of distance. The distribution of droplet density was similar to that of coverage. However, the coverage contribution by smaller droplets became more significant as the distance increased. The upward blasting distance was limited within 3m, but the limit to the ground level was expanded the distance more than 3.5m because of the concentrated droplets.

  • PDF