• Title/Summary/Keyword: Turns ratio

Search Result 225, Processing Time 0.03 seconds

The Derivation of a Model to Estimate Compensation for Damages in Chartered Fisheries by Using CVP Analysis (CVP 분석을 이용한 면허어업 손실보상액 평가 모형의 도출)

  • 정형찬
    • The Journal of Fisheries Business Administration
    • /
    • v.31 no.2
    • /
    • pp.133-153
    • /
    • 2000
  • During the last several decades, Korea has been regarded as one of the fastest growing economies in the world. However, the small size of national land has not met the vigorous demand for land necessary to develop economic infra-structures such as large-scale harbors airports and highways. In order to satisfy the growing demand for land, the Korean government and industry have implemented the national land development programs to reclaim land from the sea fur the several decades. It is certain that these land development programs have resulted in a lot of property disputes between fishermen and public project administrators. This paper is to develop a quantitative model to estimate compensation for damages or restriction of charted fisheries resulting from large-scale public projects. In this paper, the compensation model is derived by using cost-volume-profit analysis framework because the compensation for charted fisheries basically depends on the factors such as the costs, production volume, profit of charted fisheries damaged or restricted by public projects. The model shows that the compensation for damages or restriction of charted fisheries is determined by the average annual profit, damage duration period, and the degree of fishery damages. In addition, the degree of fishery damages measured by the ratio of lost profit to annual average profit turns out to be determined by the following factors: annul profit, unit variable cost, decrease in production volume, the rate of increase in variable cost, and a change in fixed cost. Furthermore, this parer discusses the nam issues related to practices and regulation of the compensation for fishery damages in the current Fishery Act of Korea and suggests some appraisal methods which will be able to lead to theoretically correct and fair compensation for fisheries damages resulting from large-scale public projects.

  • PDF

Experimental Study Of Supersonic Coanda Jet

  • Kim, Heuydong;Chaemin Im;Sunhoon, Woo
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 1999.10a
    • /
    • pp.33-33
    • /
    • 1999
  • The Coanda effect is the tendency for a fluid jet to atach itself to an adjacent surface and follow its contour without causing an appreciable flow separation. The jet is pulled onto the surface by the low pressure region which develops as entrainment pumps fluid from the region between the jet and the surface. Then the jet is held to the wall surface by the resulting radial pressure gradient which balance the inertial resistance of the jet to turning. The jet may attach to the surface and may be deflected through more than 180 dog, when the radius of the Coanda surface is sufficiently large compared to the height of the exhaust nozzle. However, if the radius of curvature is small, the jet turns through a smaller angle, or may not attach to the surface at all. In general, the limitations in size and weight of a device will limit the radius of the deflection surface. Thus much effort has been paid to improve the jet deflection in a variety of engineering fields. The Coanda effect has long been applied to improve aerodynamic characteristics, such as the drag/lift ratio of flight body, the engine exhaust plume thrust vectoring, and the aerofoil/wing circulation control. During the energy crisis of the seventies, the Coanda jet was applied to reduce vehicle drag and led to drag reductions of as much as about 30% for a trailer configuration. Recently a variety of industrial applications are exploiting another characteristics of the Coanda jets, mainly the enhanced turbulence levels and entrainment compared with conventional jet flows. Various industrial burners and combustors are based upon this principle. If the curvature of the Coanda surface is too great or the operating pressure too high, the jet flow will break away completely from the surface. This could have catastrophic consequences for a burner or combustor. Detailed understanding of the Coanda jet flow is essential to refine the design to maximize the enhanced entrainment in these applications.

  • PDF

Design of Broadband Spiral Antenna for a Portable Non-Linear Junction Detector System (휴대형 NLJD용 광대역 스파이럴 안테나의 설계)

  • Kim, Jeong-Won;Min, Kyeong-Sik
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.24 no.1
    • /
    • pp.36-46
    • /
    • 2013
  • This paper proposes the design of broadband spiral antenna for a potable non-linear junction detector (NLJD) system. To realize the broadband antenna design, it was considered optimization of the number of spiral turns by iteration calculation. Ground plane with the Archimedean spiral slit to keep the same current distribution between radiating plane and ground is considered for circular polarization design. In order to realize high directivity and high gain of the proposed antenna, the cavity wall and the metal cap which is located on back of ground plane were also considered in design. Measurement results of return loss were agreed well with VSWR 2:1 at interested frequency band among 2.4 to 2.44 GHz, 4.84 to 4.92 GHz and 7.28 to 7.36 GHz. Measured axial ratio was observed 3 dB below and showed reasonable agreement with simulation results. Characteristics of the RHCP(Right Hand Circular Polarization) with the measured gain of 6.8 dBi above at interested frequency band were also observed.

A Contactless Power Charging System using Half-Bridge Series Resonant Converter (Half-Bridge 직렬 공진컨버터 적용 비접촉 충전시스템)

  • Kim, Joo-Hoon;Song, Hwan-Kook;Kim, Eun-Soo;Park, Sung-Ho;Kim, Yoon-Ho
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.14 no.3
    • /
    • pp.251-259
    • /
    • 2009
  • In this paper, a contactless power supply using half-bridge series resonant converter that achieves ZVS operation of main switches and ZCS operation of secondary side diodes is proposed. Since the proposed contactless power supply using half-bridge series resonant converter operates with lower switching frequency than the resonant frequency, it can achieve ZCS operation of secondary side diodes due to discontinuous resonant current. And it is also possible to control the converter in narrow frequency range and to obtain high voltage gain, which, in turn, offers low turns ratio for the transformer and high efficiency. Based on the theoretical analysis and simulation results, the 3.15W prototype is built and the final experimental results are described.

Characteristics of Hydration Heat Control of Mass Concrete using Pulsating Heat Pipe in the Winter Season (진동형 히트 파이프를 이용한 매스 콘크리트의 겨울철 수화열 제어 특성)

  • Yang, Tae-Jin;Kim, Jeung-Hoon;Youm, Chi-Sun;Kim, Myung-Sik;Kim, Jong-Soo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.2
    • /
    • pp.169-174
    • /
    • 2007
  • In process of reinforced concrete (RC) box structure, the heat of hydration may cause serious thermal cracking. This paper reports results of hydration heat control in mass concrete using the oscillating heat pipe. There were three RC box molds ($1.2m{\times}1.8m{\times}2.4m$) which were different from each other. One was not equipped with pulsating heat pipe. The others were equipped with pulsating heat pipe. All of them were cooled with natural air convection. The pulsating heat pipe was composed of 10 turns of serpentine type copper pipe whose outer and inner diameters were 4 and 2.8 mm respectively. The working fluid was R-22 and charging ratio was 40% by volume. The temperature of the concrete core was approximately $55^{\circ}C$ in the winter without pulsating heat pipe. For a concrete with pulsating heat pipe, however, the temperature difference with the outdoor one reduced up to $12^{\circ}C$. The index figure of crack was varied from 0.75 to 1.38.

Plasma Uniformity Numerical Modeling of Geometrical Structure for 450 mm Wafer Process System (450 mm 웨이퍼 공정용 System의 기하학적 구조에 따른 플라즈마 균일도 모델링 분석)

  • Yang, Won-Kyun;Joo, Jung-Hoon
    • Journal of the Korean Vacuum Society
    • /
    • v.19 no.3
    • /
    • pp.190-198
    • /
    • 2010
  • Asymmetric model for plasma uniformity by Ar and $CF_4$ was modeled by the antenna structure, the diameter of chamber, and the distance between source and substrate for the development of plasma equipment for 450 mm wafer. The aspect ratio of chamber was divided by diameter, distance from substrate, and pumping port area. And we found the condition with the optimized plasma uniformity by changing the antenna structure. The drift diffusion and quasi-neutrality for simplification were used, and the ion energy function was activated for the surface recombination and etching reaction. The uniformity of plasma density on substrate surface was improved by being far of the distance between substrate wall and chamber wall, and substrate and plasma source. And when the antenna of only 2 turns was used, the plasma uniformity can improve from 20~30% to 4.7%.

Analysis on Fault Current Limiting Characteristics of a Flux-Lock Type HTSC Fault Current Limiter with Hysteresis Characteristic (히스테리시스 특성을 고려한 자속구속형 고온초전도 사고전류 제한기의 사고전류 제한특성 분석)

  • Lim, Sung-Hun;Choi, Myoung-Ho
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.2
    • /
    • pp.94-98
    • /
    • 2007
  • The fault current limiting characteristics of a flux-lock type superconducting fault current limiter (SFCL) considering hysteresis characteristics of a flux-lock reactor, which is an essential component of the flux-lock type SFCL, were investigated. In the normal state, the hysteresis loss of iron core in the flux-lock type SFCL does not happen due to its winding's structure. From the equivalent circuit for the flux-lock type SFCL and the fault current limiting experiments, the hysteresis curves could be drawn. Through the hysteresis curves together with the fault current level due to the inductance ratio between the primary and the secondary windings, the increase of the number of turns in the secondary winding of the flux-lock type SFCL made the fault current level increase. On the other hand, the saturation of iron core was prevented.

Natural Convection Heat Transfer of an Inclined Helical Coil in a Duct (기울어진 덕트 내 헬리컬 코일의 자연대류 열전달)

  • Park, Joo-Hyun;Chung, Bum-Jin
    • Journal of Energy Engineering
    • /
    • v.23 no.2
    • /
    • pp.13-20
    • /
    • 2014
  • The natural convection heat transfers of a helical coil in a duct were measured experimentally varying the inclination. To achieve high Rayleigh number, mass transfer experiments instead of heat transfer experiments were performed based upon the analogy. The $Ra_D$ was fixed to $4.55{\times}10^6$. The turn numbers were 1~10. the pitch to diameter ratio were 1.3~5, and the inclination of the helical coil $0^{\circ}{\sim}90^{\circ}$. The measured $Nu_D$ for a single turn of the helical coil was very close to that from McAdams heat transfer correlation for a horizontal cylinder. The heat transfers of the helical coil were varied by the pith, number of turns, and duct height in a complex manner showing the velocity, chimney, and pre-heating effects. The results of the study contributes to the phenomenological analyses of the natural convection heat transfer of a compact heat exchanger.

Analytical method of trace elements in ceramic capacitor materials (세라믹 축전물질들의 미량성분 분석방법)

  • Choi, J.K.;Kim, T.H.;Lim, H.B.
    • Analytical Science and Technology
    • /
    • v.10 no.1
    • /
    • pp.35-42
    • /
    • 1997
  • The sample pretreatment technique using a high pressure acid digestion bomb for the analysis of ceramic capacitor materials, such as barium titanate and PZT, was studied. When the concentrations of hydrochloric acid were varied with the addition of nitric acid or distilled water, quantitative measurements for those samples were carried out using inductively coupled plasma atomic emission spectrometry. From this experiment the results indicate that most of elements, such as Ba, Mn, Zn, Si, etc., aren't affected by the concentration of hydrochloric acid but Nb and Zr are very susceptable to it. It however turns out that the digestion time relatively gave little effects on the analytical result. In case of Nb the ratio of hydrochloric acid to water should be greater than 3:1(v / v) for the best analytical result. For the Pb determination use of diluted hydrochloric acid compared to the mixture of nitric acid and hydrochloric acid showed a better analytical result.

  • PDF

Operational Characteristics in integrated Three-Phase a Flux-Lock type SFCL according to Fault Conditions (3상 일체화된 자속구속형 전류제한기의 동작특성)

  • Lee, Na-Young;Choi, Hyo-Sang;Jeong, Soo-Bok;Lee, Sang-Il;Nam, Gueng-Hyun;Lim, Sung-Hun
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2006.05a
    • /
    • pp.467-470
    • /
    • 2006
  • Superconducting fault current(SFCLs) are expected to improve not only reliability but also stability of real power systems. The analysis on the single line-to-ground fault current of the integrated three phase flux-lock type SFCL, which consists of three flux-lock reactor wound on an iron core in each single phase and three YBCO thin films, was investigated in current limiting operating characteristics. We compared additive polarity winding with the subtractive one in the flux lock reactor. Its turns ratio each phase between the primary and the secondary coils is 63:42. When a single line-to-ground fault occurred in any phase, the peak value of line current in the fault phase of the additive polarity winding increased up to 31.44[A] during first-half cycle. On the other hand, the peak value in the subtractive polarity winding increased up to 81.77[A] under the same conditions. This is because the current flow between the primary and the secondary windings becomes to be additive or subtractive in each winding direction. We confirmed that the current limiting behavior in the additive polarity winding was more effective for a single-line-to ground fault.

  • PDF