• 제목/요약/키워드: Turn-on

검색결과 5,414건 처리시간 0.032초

Output Voltage Control Method of Switched Reluctance Generator using the Turn-off Angle Control

  • Kim Young-Jo;Choi Jung-Soo;Kim Young-Seok
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 Proceedings ICPE 01 2001 International Conference on Power Electronics
    • /
    • pp.414-417
    • /
    • 2001
  • SRG (Switched Reluctance Generator) have many advantages such as high efficiency, low cost, high-speed capability and robustness compared with characteristics of other machines. However, the control methods that have been adopted for SRGs are complicated. This paper proposes a simple control method using PID controller that only controls turn-off angles while keeping turn-on angles of SRG constant. The linear characteristics between the generated current and the turn-off angle can be used to control the turn-off angle for load variations. Since the reference current for generation can be produced from an error between the reference and the real voltage, it can be controlled to keep the output voltage constant. The proposed control method enhances the robustness of this system and simplifies the hardware and software by using only the voltage and speed sensors. The proposed method is verified by experimental results.

  • PDF

프로펠러 턴오버 장치 개발 (Development of a propeller turn-over system)

  • 신상룡;이윤식;이지형;노태양;염두식;전병진
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회A
    • /
    • pp.1081-1086
    • /
    • 2008
  • During the manufacturing process of a propeller for a large scale commercial ships, several times of turn-over process should be required. Propeller turn-over is a indispensible process but not easy because of its heavy weight and complicate shape. Recently, we developed a new type of turn-over system for a large scale propeller. The system consists of turning roller devices, sliding transfer system, clamping devices and so on. In this paper, we described the design process which includes mechanical structure design, dynamic analysis and assembly with a laser tracker.

  • PDF

높은 스위칭 주파수를 가지는 비엔나 정류기의 전류 품질 개선 (Letters Current Quality Improvement for a Vienna Rectifier with High-Switching Frequency)

  • 양송희;박진혁;이교범
    • 전력전자학회논문지
    • /
    • 제22권2호
    • /
    • pp.181-184
    • /
    • 2017
  • This study analyzes the turn-on and turn-off transients of a metal-oxide-semiconductor field-effect transistor (MOSFET) with high-switching frequency systems. In these systems, the voltage distortion becomes serious at the output terminal of a Vienna rectifier by the turn-off delay of the MOSFET. The current has low-order harmonics through this voltage distortion. This paper describes the transient of the turn-off that causes the voltage distortion. The algorithm for reducing the sixth harmonic using a proportional-resonance controller is proposed to improve the current distortion without complex calculation for compensation. The reduction of the current distortion by high-switching frequency is verified by experiment with the 2.5-kW prototype Vienna rectifier.

금이 보상된 실리콘 p-i-n 다이오드 스위치의 광 과도 특성 (Optical Transient Characteristics of Au-Compensated Silicon p-i-n Diode Switches)

  • 민남기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 하계학술대회 논문집 C
    • /
    • pp.1205-1208
    • /
    • 1995
  • The optically-gated p-i-n diode switches have been fabricated with gold-compensated silicon. The turn-on and turn-off delay times and the rise and fall times were measured as a function of optical power level, bias, and pulse width. The turn-on characteristics shows a strong dependence an optical pulse power and a delay time(${\delta}{\iota}$) between two pulses, but a weak dependence on the width of optical pulse. Actually there is no turn-off delay in gold-doped p-i-n switches and the fall time is negligible.

  • PDF

양수발전소 발전-전동기 운전중 감시 시스템의 개발 (Development of On-Line Monitoring System for Pumped Storage Generator/Motor)

  • 김희동;주영호
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제53권3호
    • /
    • pp.168-174
    • /
    • 2004
  • On-line monitoring system(OMS) has been developed for the pumped storage generator/motor The OMS is applied to diagnosis of the PD(partial discharge) activity of stator insulation, the shorted-turn of rotor winding and the variation of the air-gap between stator and rotor. The OMS consists of DAS(data acquisition system), main server system, gateway and display PC. The DAS measures the PD, the shorted-turn and air-gap from three sensors installed on the generator/motor. The gateway controls the data which sent by DAS. The main server system saves the data, analyzes the data and conducts the diagnostic algorithm. The display PC shows the diagnostic results of partial discharge, shorted-turn and air-gap. Field tests were conducted using PDA(partial discharge analyzer). The results of the OMS and PDA measurements can be directly correlated with normalized quantity number(NQN), PD magnitude(Qm) and PD pattern.

Winding Turn-to-Turn Faults Detection of Fault-Tolerant Permanent-Magnet Machines Based on a New Parametric Model

  • Liu, Guohai;Tang, Wei;Zhao, Wenxiang
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • 제2권1호
    • /
    • pp.23-30
    • /
    • 2013
  • This paper proposes a parametric model for inter-turn fault detection in a fault-tolerant permanent-magnet (FTPM) machine, which can predict the effect of the short-circuit fault to various physical quantity of the machine. For different faulty operations, a new effective stator inter-turn fault detection method is proposed. Finally, simulations of vector-controlled FTPM machine drives are given to verify the feasibility of the proposed method, showing that even single-coil short-circuit fault could be exactly detected.

발전기 회전자의 층간단락 센서리스 진단기법 및 특성 해석 (Sensorless Diagnosis Method and Characteristic Analysis of Short-Circuited Turn for Generator Rotor)

  • 김선자;전윤석;이승학;최규하
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2003년도 추계학술대회 논문집
    • /
    • pp.210-213
    • /
    • 2003
  • Short-circuited can have significant effects on a generator and its performance. One of effective method detecting inter-turn short circuits on round rotor winding is a method using sensor detecting. But the method needs duplicate design of sensor for characteristic change according to types and forms of generator. Thus rotor shorted-turn diagnosis method without sensor is needed for detecting short turn when generator is driven. Diagnosis method without sensor depend on change of electric property in generator For the reason, this paper presents characteristic analysis of shorted-turns in generator by detecting the output voltage of generator.

  • PDF

이산 웨이브렛 변환을 이용한 동기발전기 회전자 층간단락 진단에 관한 연구 (A Study of Shorted-Turn Detection in the Cylindrical Synchronous Generator Rotor Windings via Discrete Wavelet Transform)

  • 김영준;김장목
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2005년도 전력전자학술대회 논문집
    • /
    • pp.476-478
    • /
    • 2005
  • This paper describes a method for the detection of shorted-turn in the cylindrical synchronous generator rotor windings based on the discrete wavelet transform. Multi-resolution analysis(MRA) based on discrete wavelet transform provides a set of decomposed signals in independent frequency bands. In the proposed method, shorted-turn detection in rotor windings is based on the decomposition of the rotor currents, where wavelet coefficients of these signals have been extracted. Comparing these extracted coefficients is used for diagnosing the healthy machine from faulty machine. Experimental results show the effectiveness of the proposed method for shorted-turn detection in the cylindrical synchronous generator rotor windings.

  • PDF

발전기 회전자 권선의 층간단락 진단시스템 개발 (Development of Shorted-Turn Diagnosis system for Generator Rotor Winding)

  • 이영준;김희동;주영호
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제48권11호
    • /
    • pp.742-747
    • /
    • 1999
  • On-line diagnosis system has been developed and is now applied the detection of shorted turns in the field winding of large generator. This system consists of data aquisition system and display PC. The data aquisition system detects voltage waveforms from flux probe sensor installed in the stator slot. The display PC shows theshorted-turn situation of generator rotor winding. A shorted-turn diagnosis test wasperformed on five gas turbine generators at the Seoinchon combined cycle power plant. The test was conducted using an new diagnosis system and digital oscilloscope which can identify the pole location, the slot number and the number of shorted turns within each slot. It is confirmed that results of two systems are very same in the field tests.

  • PDF

SCR, MVSCR, LVTSCR의 Turn-on time 및 전기적 특성에 관한 연구 (Analysis of SCR, MVSCR, LVTSCR With I-V Characteristic and Turn-On-Time)

  • 이주영
    • 전기전자학회논문지
    • /
    • 제20권3호
    • /
    • pp.295-298
    • /
    • 2016
  • 본 논문에서는 기존 ESD 보호소자인 SCR과 MVSCR, LVTSCR의 Turn-on-Time 및 전기적 특성을 시놉시스사의 T-Cad 시뮬레이션을 통하여 분석하였다. 분석결과 세 소자 모두 대략 2V 에서 3V 내외의 홀딩전압 특성을 보였으며, SCR은 약 20V의, MVSCR은 약 12V, LVTSCR은 9V로 순차적으로 개선된 트리거 특성을 보였다. 턴-온타임 시뮬레이션 결과는 SCR이 2.8ns, MVSCR과 LVTSCR은 각각 2.2ns, 2.0ns로 LVTSCR이 가장 짧은 턴-온 특성을 보였다. 반면 IT2 는 SCR이 약 7.7A, MVSCR은 5.5A LVTSCR은 4A의 특성을 보였으므로 I/O 및 파워 클램프 단에 적용 시 동작전압에 따른 최적화된 소자를 선택해야 한다.