• Title/Summary/Keyword: Turn to Turn Defect

Search Result 46, Processing Time 0.026 seconds

Characteristics of Ultra High Frequency Partial Discharge Signals of Turn to Turn Defect in Transformer Oil (절연유 내 변압기 Turn간 결함에 의한 부분방전의 극초단파 전자기파 신호 특성)

  • Yoon, Jin-Yul;Ju, Hyung-Jun;Goo, Sun-Geun;Park, Ki-Jun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.10
    • /
    • pp.2000-2004
    • /
    • 2009
  • In general, for the condition monitoring of a power transformer using the UHF PD measuring technique, detection of any partial discharge, identifying the defect in the transformer and locating the insulation defect are necessary. In this paper one of the most frequent detects which can result in turn to turn fault in power transformer was examined for identifying the defect. In order to model the defect, as a discharge source, a partial discharge cell was used for experimental activity. Magnitude of electromagnetic wave signals and corresponding amount of apparent discharge were measured simultaneously against phase of applied voltage to the discharge cell. Frequency range and phase resolved partial discharge signals were measured and analyzed. The results will be contributed to build the defect database of power transformer and to decrease the occurrence of transformer faults.

The effect of deep level defects in SiC on the electrical characteristics of Schottky barrier diode structures (깊은 준위 결함에 의한 SiC SBD 전기적 특성에 대한 영향 분석)

  • Lee, Geon-Hee;Byun, Dong-Wook;Shin, Myeong-Cheol;Koo, Sang-Mo
    • Journal of IKEEE
    • /
    • v.26 no.1
    • /
    • pp.50-55
    • /
    • 2022
  • SiC is a power semiconductor with a wide bandgap, high insulation failure strength, and thermal conductivity, but many deep-level defects. Defects that appear in SiC can be divided into two categories, defects that appear in physical properties and interface traps that appear at interfaces. In this paper, Z1/2 trap concentration 0 ~ 9×1014 cm-3 reported at room temperature (300 K) is applied to SiC substrates and epi layer to investigate turn-on characteristics. As the trap concentration increased, the current density, Shockley-read-Hall (SRH), and Auger recombination decreased, and Ron increased by about 550% from 0.004 to 0.022 mohm.

Analysis of Insulation Condition in Traction Motor Stator Windings (견인전동기 고정자 권선의 절연상태 분석)

  • Kim, Hee-Dong;Park, Young
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.20 no.7
    • /
    • pp.631-635
    • /
    • 2007
  • Diagnostic, surge and ac breakdown tests are widely used to evaluate the insulation condition of stator winding in traction motor. Diagnostic test included ac current, tan delta and maximum partial discharge. The result of diagnostic test indicates that five kinds of stator windings are good condition. Surge test was peformed to confirm the healthy of turn insulation in stator windings. This test is very easy to detect the turn insulation failure between normal and defect stator windings. After completing the diagnostic test, ac breakdown test has conducted gradually increasing ac voltage, until the stator winding punctured. No. 5 stator windings failed near rated voltage of 18.9 kV The breakdown voltage of No. 1 stator windings was 13.0 kV The ac breakdown voltage of normal winding is about 1.45 times higher than that of defect windings. The failure was located in a line-end coil at the exit from the core slot.

Adipofacial Turn-Over Flap for Reconstruction of the Foot and Ankle (지방근막 역전 피판을 이용한 발과 발목의 재건)

  • Lee, Won Jai;Yang, Eun Jung;Tark, Kwan Chul;Chung, Yun Kyu
    • Archives of Plastic Surgery
    • /
    • v.34 no.4
    • /
    • pp.441-447
    • /
    • 2007
  • Purpose: Various kinds of local flap or free flap have been used for coverage for soft tissue defects with bone exposure over the ankle and dorsum of foot. Adipofascial flaps, nourished by vascular plexuses of the subcutaneous tissue and deep fascia originating from the local perforators of the major vessels, appear particularly to be indicated for the reconstruction of these areas. Our experience with this flap on the dorsum of foot and ankle has also been quite encouraging. Methods: The design of the flap is determined by the size and the location of the defect. The base of the flap is chosen depending on the availability of the soft tissue around the defect. The ratio of the area of the flap to the area of the base wound be more reliable to predict the survival of the turnover flap by the conventional length-to-width ratio. Nineteen patients with defect over the dorsum of the foot and ankle were resurfaced with adipofascial turn-over flaps and skin graft. Results: The average age of the patients was 38.2 years(3 - 81 years). The flap size was from $2{\times}3cm$ to $8{\times}5cm$. The average follow-up time was 6 months. All flaps survived completely except one case who suffered distal necrosis of the flap. The additional skin graft was required for partial skin loss in the five cases. Other functional impairment was not noted. Conclusion: Dissection of the local adipofascial turnover flap is quite easy, quick, requires less time and sacrifice of surrounding muscle itself, and maintains major arteries. In most cases, donor-site morbidity is minimal with an acceptable scar, and both functional and esthetical results were satisfactory. Therefore, Adipofascial flap could be an option for the difficult wounds around the foot and ankle.

CMM(Compact Camera Module) Defect Inspection (CMM(Compact Camera Module) 불량 검사)

  • 고국원;이유진;최병욱;고경철
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.585-589
    • /
    • 2004
  • This paper deals with the algorithm development that inspects defects such as Lens Focus, Black Defect, Dim Defect, Color Defect, White Balance, and Line Defect caused by the process of Compact Camera Module (CCM). These days the demand of CCM goes on increasing in various types like PDA, a cellular phone and PC camera every year. However, owing to the defect inspection of CCM by the semiskilled work the average inspection time of CCM takes about 40 to 50 seconds. As time goes by the efficiency takes a sudden turn for the worse because workers must inspect with seeing a monitor directly. In this paper, to solve these problems, we developed the imaging processing algorithm to inspect the defects in captured image of assembled CCM. The performances of the developed inspection system and its algorithm are tested on many samples. Experimental results reveal that the proposed system can focus the lens of CCM within 5s and we can recognize various types of defect of CCM modules with good accuracy and high speed.

  • PDF

Turn signal lamp jacket to prevent accident of bicycles

  • Saxena, Tarika
    • Korean Journal of Artificial Intelligence
    • /
    • v.4 no.1
    • /
    • pp.4-7
    • /
    • 2016
  • These days, citizens have made change of food life to take Western style food and to suffer from diabetes because of excessive nutrition taking, less exercise, stress and other environmental factors. They may suffer from diabetes because of genetic defect, surgery of pancreas, disinfection and medicine and others. One of ten Koreans may have symptom of diabetes to be popular. The diabetes that is a kind of metabolic disease has high blood sugar at disorder of hyper insulinism and/or defect of insulin action. Long time high blood sugar may produce chronic disease of kidney, eyes, nerve, heart and blood vessel and others. The purpose of health care of diabetes patient was to reach target blood sugar by diet, physical exercise and medicine and to prevent and delay complication. Diabetes patient shall control blood sugar to keep healthy. The blood sugar control requires time and effort, and all of the patients are difficult to make effort and to spend time. You can control blood sugar by the application. The application allows patients to control blood sugar and to save time and efforts and to make small sized input and automation of remaining area. The service was limited to blood sugar graph, and user carries smart phone to conduct test and to have difficulty. Further study needs to solve the problems and to investigate blood sugar testing not carrying smart phone and to make application of easy control of blood sugar.

A Study on the Relative Importance of Quality Management Items through the Defect Analysis in the Landscape Construction Process (조경시설공사의 시공품질 분석을 통한 품질관리항목의 중요도 연구)

  • 이상석;최기수
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.25 no.3
    • /
    • pp.1-11
    • /
    • 1997
  • This study aims to estimate the relative importance of quality management items through the defect analysis in the landscape construction process. The RIQMI are decided by the defect coefficient and it's cause weight. The defect items in the landscape construction process were classified by 56 items based on the classification form of '96 landscape architectural construction standard and the cause pattern were categorized 4 types as design, material, construction, and environment factors. To analyze the defect coefficient and the aucse weight by defect, the researcher surveyed the questionnaires on the 103 engineers and the 31 experts on the landscape architectural construction. The result of this study are as follows. The relative importance by facilities pattern turn out to be much higher construction, material fator than design. environment factor in wood facilities, paving facilities, and steel facilities, the RIQMI is very high in timber crack, timber vending, faulty of timber against decay, welding faulty of steel facilities in material factor, and timber crack, faulty of timber against decay, finish faulty of steel facilities, welding faulty of steel facilities in construction factor.

  • PDF

Osteocutaneous Turn-Up Fillet Flaps: A Spare-Parts Orthoplastic Surgery Option for a Functional Posttraumatic Below-Knee Amputation

  • Harry Burton;Alexios Dimitrios Iliadis;Neil Jones;Aaron Saini;Nicola Bystrzonowski;Alexandros Vris;Georgios Pafitanis
    • Archives of Plastic Surgery
    • /
    • v.50 no.5
    • /
    • pp.501-506
    • /
    • 2023
  • This article portrays the authors' experience with a complex lower limb bone and soft tissue defect, following chronic osteomyelitis and pathological fracture, which was managed by the multidisciplinary orthoplastic team. The decision for functional amputation versus limb salvage was deemed necessary, enhanced by the principles of "spare parts" in reconstructive microsurgery. This case describes the successful use of the osteocutaneous distal tibia turn-up fillet flap that allowed "lowering the level of the amputation" from a through knee to a below-knee amputation (BKA) to preserve the knee joint function. We comprehensibly review reports of turn-up flaps which effectively lower the level of amputation, also applying "spare-parts" surgery principles and explore how these concepts refine complex orthoplastic approaches when limb salvage is not possible to enhance function. The osteocutaneous distal tibia turn-up fillet flap is a robust technique for modified BKA reconstructions that provides sufficient bone length to achieve a tough, sensate stump and functional knee joint.

Superior Gluteal Artery Perforator Turn-Over Flap Coverage for Lumboscaral Soft Tissue Defect in Ambulatory Patient (보행 환자에서의 위볼기동맥천공지뒤집기피판을 이용한 허리엉치 부위 연부조직 결손의 치료)

  • Moon, Suk-Ho;Kim, Dong-Seok;Oh, Deuk-Young;Lee, Jung-Ho;Rhie, Jong-Won;Seo, Je-Won;Ahn, Sang-Tae
    • Archives of Plastic Surgery
    • /
    • v.37 no.5
    • /
    • pp.712-716
    • /
    • 2010
  • Purpose: Extensive lumbosacral defects after removal of spinal tumors have a high risk of wound healing problems. Therefore it is an effective reconstructive strategy to provide preemptive soft tissue coverage at the time of initial spinal surgery, especially when there is an instrument exposure. For soft tissue reconstruction of a lumbosacral defect, a variation of the gluteal flap is the first-line choice. However, the musculocutaneous flap or muscle flap that is conventionally used, has many disadvantages. It damages gluteus muscle and causes functional disturbance in ambulation, has a short pedicle which limits areas of coverage, and can damage perforators, limiting further surgery that is usually necessary in spinal tumor patients. In this article, we present the superior gluteal artery perforator turn-over flap that reconstructs complex lumbosacral defects successfully, especially one that has instrument exposure, without damaging the ambulatory function of the patient. Methods: A 67 year old man presented with sacral sarcoma. Sacralectomy with L5 corpectomy was performed and resulted in a $15{\times}8\;cm$ sized complex soft tissue defect in the lumbosacral area. There was no defect in the skin. Sacral stabilization with alloplastic fibular bone graft and reconstruction plate was done and the instruments were exposed through the wound. A $18{\times}8\;cm$ sized superior gluteal artery perforator flap was designed based on the superior gluteal artery perforator and deepithelized. It was turned over 180 degrees into the lumbosacral dead space. Soft tissue from both sides of the wound was approximated over the flap and this provided in double padding over the instrument. Results: No complications such as hematoma, flap necrosis, or infection occurred. Until three months after the resection, functional disturbances in walking were not observed. The postoperative magnetic resonance imaging scan shows the flap volume was well maintained over the instrument. Conclusion: This superior gluteal artery perforator turn-over flap, a modification of the conventional superior gluteal artery perforator flap, is a simple method that enabled the successful reconstruction of a lumbosacral defect with instrument exposure without affecting ambulatory function.

Study on Wear of Journal Bearings during Start-up and Coast-down Cycles of a Motoring Engine - II. Analysis Results (모터링 엔진의 시동 사이클 및 시동 정지 사이클에서 저어널베어링의 마모 연구 - II. 해석 결과)

  • Chun, Sang Myung
    • Tribology and Lubricants
    • /
    • v.31 no.3
    • /
    • pp.125-140
    • /
    • 2015
  • In this paper, we present the results of the wear analysis of journal bearings on a stripped-down single-cylinder engine during start-up and coast-down by motoring. We calculate journal bearing wear by using a modified specific wear rate considering the fractional film defect coefficient and load-sharing ratio for the asperity portion of a mixed elastohydrodynamic lubrication (EHL) regime coupled with previously presented graphical data of experimental lifetime linear wear in radial journal bearings. Based on the calculated wear depth, we obtain a new oil film thickness for every crank angle. By examination of the oil film thickness, we determine whether the oil film thickness at the wear scar region is in a mixed lubrication regime by comparing dimensionless oil film thickness, h/σ, to 3.0 at every crank angle. We present the lift-off speed and the crank angles involved with the wear calculation for bearings #1 and #2. The dimensionless oil film thickness, h/σ, illustrates whether the lubrication region between the two surfaces is still within the bounds of the mixed lubrication regime after scarring of the surface by wear. In addition, we present in tables the asperity contact pressure, the real minimum film thickness at the wear scar region, the modified specific wear rate, and the wear angle, α, for bearings #1 & #2. To show the real shape of the oil film at wear scar region, we depict the actual oil film thickness in graphs. We also tabulated the ranges of bearing angles related with wear scar. We present the wear volume for bearings #1 and #2 after one turn-on and turn-off of the engine ignition switch for five kinds of equivalent surface roughness. We show that the accumulated wear volume after a single turn-on and turn-off of an ignition switch normally increases with increasing surface roughness, with a few exceptions.