• 제목/요약/키워드: Turbine Load

검색결과 719건 처리시간 0.039초

터보 과급 디젤 기관의 동특성에 관한 연구 (A Study on the Dynamic Characteristics of a Turbocharged Diesel Engine)

  • 최낙정;이창식
    • 한국자동차공학회논문집
    • /
    • 제3권1호
    • /
    • pp.143-154
    • /
    • 1995
  • This study investigates the response characteristics of a four-cylinder four-stroke turbocharged diesel engine by using computer simulation and experiments when a rapid acceleration is applied to the fuelpump rack. In the theoretical analysis, linearization method is used to avoid the difficulty on the complex nonlinear functions. Comppressor exit pressure, pressure and temperature of turbine inlet, and turbocharger speed are chosen as the independent variables of transfer functions which represent the dynamic characteristics of the turbocharger system, and expressed as the functions with respect to the time. Experiments on the same eigine system are also carried out to prove the validity of theoretical study. Further, this study carried an experiment for improving transient response performance by injecting air into the inlet manifold under the rapid accelerating conditions. The effects of air injection on the response performances are also represented at varying conditions such as injection pressure, injection period, accelerating rate, accelerating time, engine speed and load.

  • PDF

독립형 태양광 풍력 복합발전 시스템에서 안정적인 전력공급을 위한 축전지 용량의 최적 산정에 관한 연구 (The Study on Optimize the Battery of Stand Alone PV/Wind Hybrid System for Supplying Stably Power)

  • 최병수;김재철
    • 조명전기설비학회논문지
    • /
    • 제25권9호
    • /
    • pp.26-32
    • /
    • 2011
  • The object of this paper is to optimize the battery system for supplying stably power in separate house in which a PV-wind hybrid power generation system is applied. In a power system to be used in a stand alone, it is very important to build optimize the electrical storage system and to utilize it for supplying stably output voltage when there is a shortage of the power generation capacity or there is no sunshine, or when power is to be supplied with a load. This paper provides an optimized method to evaluate capacity of battery by analyzing advantages and disadvantages of the existing battery evaluating method being used in each company for supplying stably power in separate house utilizing the new renewable energy such as a light of the sun.

소형 풍력용 슬롯리스 영구자석형 발전기에 관한 연구 (A Study of Slotless Permanent Magnet Generator for Small Wind Turbine)

  • 김형길;공정식;오진훈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.981-982
    • /
    • 2011
  • This paper discusses design aspects of slotless permanent magnet generator for high performance and low speed applications. The airgap flux density in was obtained from finite element analysis and the design of a PM generator. The relatively large diameter stator laminations of such machines tend, therefore, to have a very thin back of core and narrow teeth, which make them expensive and difficult to manufacture. this thesis proposes an alternative PM generator topology featuring a slotless stator whose laminations are manufactured from a split core. The test results with a resistive load confirm the satisfactory operation of generator.

  • PDF

구동 속도를 고려한 고속 영구자석형 동기발전기의 특성 해석 (Characteristic Analysis of a High Speed Permanent Magnet Synchronous Generator considering the Operating Speed)

  • 장석명;고경진;조한욱;정연호;오원규
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.116-118
    • /
    • 2006
  • Recently more attention is paid to the development of high-speed permanent magnet (PM) synchronous generators driven by gas-turbine, since they are conductive to high efficiency, high power density, small size, low weight, simple mechanical construction, easy maintenance and good reliability. In this paper, the performance analysis of a high-speed PM synchronous generator for military power application considering the min-max operating speed is presented. The output current and power versus DC-link voltage loci can obtained by solving the PM machine's steady-state equations for variable resistive load.

  • PDF

작동 수명을 고려한 NREL 1.5MW 급 수평축 풍력터빈 블레이드의 최적설계 (Design Optimization of NREL 1.5MW HAWT considering the operating life)

  • 정지훈;박경현;전상욱;조준호;최선;이동호
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2011년도 춘계학술대회 초록집
    • /
    • pp.60.1-60.1
    • /
    • 2011
  • 본 연구에서는 풍력 터빈 블레이드의 다분야 통합 최적 설계를 위하여, 진동하는 비정상 공력하중에 의한 작동 수명을 고려한 최적화 과정을 수행하였다. 최적화 대상으로는 NREL의 1.5MW 급 풍력터빈을 baseline 으로 하였고, NREL의 FAST 프로그램을 이용하여 발전기의 정격 출력 및 블레이드에 작용하는 비정상 공력 하중 특성을 분석하였다. 최적화 수행 시 블레이드 형상의 효율적인 구현을 위해 형상모델링 함수를 이용하여 코드 길이와 트위스트 분포를 모델링하였다. 그리고 상용 MDO Framework 인 Piano를 이용하여 블레이드 루트부의 비정상 공력하중 조건을 완화시키는 최적화 설계를 수행하였다. 정격출력을 유지하면서도 Out of Plain 방향의 하중 조건을 개선하여 보다 긴 작동 수명을 기대할 수 있는 블레이드 형상을 설계하였다.

  • PDF

Fluid-structure interaction simulation of a floating wave energy convertor with water-turbine driven power generation

  • Zullah, Mohammed Asid;Lee, Young-Ho
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제40권8호
    • /
    • pp.710-720
    • /
    • 2016
  • The Floating Wave Energy Convertor (FWEC) mooring design has an important requirement associated with the fact that, for a wave energy converter, the mooring connections may interact with their oscillations, possibly modifying its energy absorption significantly. It is therefore important to investigate what might be the most suitable mooring design according to the converter specifications and take into account the demands placed on the moorings in order to assure their survivability. The objective of this study is to identify a computational fluid dynamics method for investigating the effects of coupling a wave energy device with a mooring system. Using the commercial software ANSYS AQWA and ANSYS FLUENT, a configuration was studied for different displacements from the equilibrium position, load demands on the moorings, and internal fluid motion. These results and findings form a basis for future efforts in computational model development, design refinement, and investigation of station keeping for FWEC units.

2MW 너셀 커버 및 지지 구조물 설계 (Design of 2MW Nacelle Cover and Support Structure)

  • 홍혁수;방조혁;박진일;류지윤;김두훈
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2007년도 추계학술대회 논문집
    • /
    • pp.331-334
    • /
    • 2007
  • Wind turbine is composed by 3 major parts, rotor ass'y, nacelle ass'y and tower. There are two major point in nacelle cover analysis one is nacelle cover itself the other is cover support structure. Both of them are required strength proof with light weight. For the design of structure, the loads are calculated according to GL wind guideline Ed. 2003 and by the commercial F.E. codes,

  • PDF

Modeling and Control of Three-Phase Self-Excited Induction Generator Connected to Grid

  • Chandrasekaran, Natarajan;Karthikeyan, A
    • Transactions on Electrical and Electronic Materials
    • /
    • 제18권5호
    • /
    • pp.265-272
    • /
    • 2017
  • This paper presents the dynamic modeling, analysis, and control of an AC/DC/AC-assisted, self-excited induction generator connected to the grid. The dynamic model includes wind turbine models with pitch control, gear boxes, self-excited induction generators, excitation capacitance, inductive load models, controlled six-pulse rectifiers, and novel state-space models of a grid-connected inverter. The system has been simulated to verify its capabilities of buildup voltage, stator flux response, stator phase current, electromagnetic torque, and magnetizing inductance variation during both the dynamic and steady states with a variable-speed prime mover. The complete setup of the above dynamic models was simulated using MATLAB/SIMULINK.

발전기/제어계 특성시험을 통한 제주한림 S/T 모델정수 결정과 전압제어특성 평가 (Cheju Hanlim S/T Model Parameter Determination and Assessment of Voltage Control Loop on the Characteristic Tests of Generator/Excitation System)

  • 김동준;문영환;이금진;윤용범
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 추계학술대회 논문집 학회본부 A
    • /
    • pp.147-149
    • /
    • 1999
  • This paper deals with the determination of generator/exciter model parameters for a Cheju Hanlim steam turbine unit. Using the recorded data from the generator characteristic tests, the model parameters have been derived and verified by comparing the simulation results and recorded data. In addition to it, the closed-loop performance of voltage control on no-load condition has been assessed in the frequency domain by taking advantage of derived generator/exciter model parameters.

  • PDF

Annual Energy Production Maximization for Tidal Power Plants with Evolutionary Algorithms

  • Kontoleontos, Evgenia;Weissenberger, Simon
    • International Journal of Fluid Machinery and Systems
    • /
    • 제10권3호
    • /
    • pp.264-273
    • /
    • 2017
  • In order to be able to predict the maximum Annual Energy Production (AEP) for tidal power plants, an AEP optimization tool based on Evolutionary Algorithms was developed by ANDRITZ HYDRO. This tool can simulate all operating modes of the units (bi-directional turbine, pump and sluicing mode) and provide the optimal plant operation that maximizes the AEP to the control system. For the Swansea Bay Tidal Power Plant, the AEP optimization evaluated all different hydraulic and operating concepts and defined the optimal concept that led to a significant AEP increase. A comparison between the optimal plant operation provided by the AEP optimization and the full load operating strategy is presented in the paper, highlighting the advantage of the method in providing the maximum AEP.