• 제목/요약/키워드: Tunnel particles

검색결과 81건 처리시간 0.023초

산업용 로 내 고체 미립자의 거동 예측을 위한 유동-고체입자 간 비산에 관한 실험과 해석 (Experimental and computational study on fluid flow-solid particles interaction associated with entrainment behavior of the particles in the industrial furnaces)

  • 이후경;엄민제;최상민
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2012년도 제44회 KOSCO SYMPOSIUM 초록집
    • /
    • pp.93-96
    • /
    • 2012
  • In the industrial furnaces or reactors, entrainment of the material particles is one of the important issues from the point of view of efficient material-use. The particles of solid phase which has submicron unit are easily entrained with gas phase as a reacting agent or product, and it causes a loss of the material. In this study, wind-tunnel experiment is carried out to interpret the distribution of the particles entrained along the tunnel length. Through CFD-based computational analysis of the experiment, availability of result from the CFD analysis associated with particle size distribution and gaseous velocity to practical system is evaluated.

  • PDF

Characterization of Summertime Aerosol Particles Collected at Subway Stations in Seoul, Korea Using Low-Z Particle Electron Probe X-ray Microanalysis

  • Kim, Bo-Wha;Jung, Hae-Jin;Song, Young-Chul;Lee, Mi-Jung;Kim, Hye-Kyeong;Kim, Jo-Chun;Sohn, Jong-Ryeul;Ro, Chul-Un
    • Asian Journal of Atmospheric Environment
    • /
    • 제4권2호
    • /
    • pp.97-105
    • /
    • 2010
  • A quantitative single particle analytical technique, denoted low-Z particle electron probe X-ray microanalysis (low-Z particle EPMA), was applied to characterize particulate matters collected at two underground subway stations, Jegidong and Yangje stations, in Seoul, Korea. To clearly identify the source of the indoor aerosols in the subway stations, four sets of samples were collected at four different locations within the subway stations: in the tunnel; at the platform; near the ticket office; nearby outdoors. Aerosol samples collected on stages 2 and 3 ($D_p$: $10-2.5\;{\mu}m$ and $2.5-1.0\;{\mu}m$, respectively) in a 3-stage Dekati $PM_{10}$ impactor were investigated. Samples were collected during summertime in 2009. The major chemical species observed in the subway particle samples were Fe-containing, carbonaceous, and soil-derived particles, and secondary aerosols such as nitrates and sulfates. Among them, Fe-containing particles were the most popular. The tunnel samples contained 85-88% of Fe-containing particles, with the abundance of Fe-containing particles decreasing as the distances of sampling locations from the tunnel increased. The Fe-containing subway particles were generated mainly from mechanical wear and friction processes at rail-wheel-brake interfaces. Carbonaceous, soil-derived, and secondary nitrate and/or sulfate particles observed in the underground subway particles likely flowed in from the outdoor environment by human activities and the air-exchange between the subway system and the outdoors. In addition, since the platform screen doors (PSDs) limit air-mixing between the tunnel and the platform, samples collected at the platform at the Yangjae station (with PSDs) showed a marked decrease in the relative abundances of Fe-containing particles compared to the Jegidong station (without PSDs).

Chemical Composition of the Size-resolved Particles in Buk-Ak Tunnel

  • Ma, Chang-Jin;Hwang, Kyung-Chul;Kang, Gong-Unn;Tohno, Susumu
    • Journal of Korean Society for Atmospheric Environment
    • /
    • 제20권E2호
    • /
    • pp.53-59
    • /
    • 2004
  • The roadway tunnels in urban areas give rise to problems such as a localized air pollution. Here, we report the results of a case study of an urban roadway tunnel measurement. The size-resolved particle sampling was carried out with a two 2-stage filter pack samplers and an Andersen impactor sampler at the center of Buk-Ak tunnel in November 2001. Particle Induced X-ray Emission (PIXE) was applied to determine the elemental composition of size-resolved particles divided into soluble and insoluble fractions. The Thermal/Optical Reflectance (TOR$^{(R)}$) method was also employed in analyzing of elemental carbon (EC) and organic carbon (OC). Mass concentrations of fine (< 1.2 ${\mu}{\textrm}{m}$) and coarse (> 1.2 ${\mu}{\textrm}{m}$) particles are 165 and 48 $\mu\textrm{g}$ m$^{-3}$ , respectively. Total elemental mass concentration (the sum of insoluble coarse, soluble coarse, insoluble fine, and soluble fine) is found to be 24$\mu\textrm{g}$ m$^{-3}$ and comprises only 11 % of total particle mass concentration. The concentrations of EC, OC, and mass show the clear dependency on particle size with the maximum between 0.1 and 0.43 ${\mu}{\textrm}{m}$ aerodynamic diameters. Total carbon (sum of EC and OC) accounts for approximately 70% of mass concentration.n.

도시 자동차도로 터널 내부의 대기오염도 공간분포 특징 (Spatial Distribution of Air Pollution Level inside Roadway Tunnels in Urban Area)

  • 박보은;이승복;이동훈;이승재;우대광;최재현;진현철;배귀남;윤성택
    • 한국입자에어로졸학회지
    • /
    • 제8권1호
    • /
    • pp.17-28
    • /
    • 2012
  • Air pollution levels of gases and aerosol particles inside the Jeongneung and Hongjimun tunnels of the Naebu express way in Seoul were investigated through on-road measurement using a mobile emission laboratory (MEL) on February 8, 2011. The concentrations of $NO_x$, $CO_2$, number concentration of particles ranging 21-560 nm, and surface area of particles deposited on a human lung almost linearly increased with increasing distance from the tunnel entrance, and decreased rapidly before the tunnel exit. This trend was observed regardless of tunnel length and driving directions, which thought to be caused by semi-transverse ventilation facilities of the tunnels. The concentration increments per 1-m distance for $NO_x$, $CO_2$, deposited particle surface area, and number of particles ranging 21-560 nm were 0.61~0.80 ppb, 0.16~0.21 ppm, $0.20{\sim}0.29{\mu}m^2/cm^3$, and 117~192 particles/$cm^3$, respectively. Average pollution levels inside the two tunnels for $CO_2$, deposited particle surface area, and number of particles >5.6 nm ranged 681~748 ppm, $246{\sim}381{\mu}m^2/cm^3$, and $2.4{\sim}6.7{\times}10^5$ particles/$cm^3$, respectively. In case of $NO_x$, the maximum concentration exceeded 1 ppm. These pollution levels inside the tunnels are much higher than those at urban background sites. This result can be utilized as basic data to evaluate the effectiveness of present ventilation system for reducing the pollution level caused by vehicles inside the tunnels.

2단 평행판 전기집진기의 서브마이크론 입자 포집특성 실험 (Experiment on Collection Characteristics of Sub micron Particles in Two-Stage Parallel-Plate Electrostatic Precipitators)

  • 오명도;유경훈
    • 설비공학논문집
    • /
    • 제6권3호
    • /
    • pp.237-246
    • /
    • 1994
  • Experimental data are reported for charging and collection of NaCl aerosols in the 0.03- to $0.2{\mu}m$-geometric-mean-diameter range in 2-stage parallel-plate electrostatic precipitators. The NaCl aerosols are generated with geometric standard deviation of about 1.74 and particle generation rate of about 10^9 particles/see by the constant output atomizer and injected into the air flow in the clean wind-tunnel. The 2-stage parallel-plate electrostatic precipitator installed in the test section of the wind-tunnel is operated with a positive corona discharge. The NaCl aerosols in the channel flow are sampled and transported to the aerosol particle number concentration measurement system by using the isoaxial sampling and transport system constructed based on the Okazaki and Willeke design. The aerosol particle number concentration measurement system measures the size distribution of submicrometer aerosols by an electrical mobility detection technique. It is confirmed from comparing the measured collection efficiencies in this study and the predicted ones by our previous theoretical analysis that the predicted collection efficiencies agree well with the experimental ones. It is also found from the comparison that below about $0.02{\mu}m$ all particles are not charged and the uncharged particles are not collected, and consequently 2-stage parallel-plate electrostatic precipitators are not suitable for that particle size range.

  • PDF

초미세기포 water jet을 이용한 도로 시설물 분진 제거 효율 평가 (Evaluation of Dust Removal Efficiency on Roadway Structures Using Ultrafine Bubble Water Jet)

  • 김현진;박일건
    • 청정기술
    • /
    • 제27권1호
    • /
    • pp.39-46
    • /
    • 2021
  • 4 HP, 80 LPM 급 초미세기포수 발생장치를 탑재한 도로 구조물 세척차량을 이용하여 도시 내 아파트 단지 주변 차량 통행이 많은 터널 내 콘크리트 표면과 타일 벽면을 세척하였다. 초미세기포 생성은 대기 중 공기를 2 ~ 3 LPM 으로 기액혼합 자흡펌프로 가압된 공기를 임펠러 회전력을 이용하여 마이크로 크기의 미세기포(fine-bubble)를 생성한다. 생성된 기포를 다단충돌판과 회전 노즐을 통과하면서 평균 직경 크기는 164.5 nm, 6.81 × 107 particles mL-1의 초미세기포(ultrafine bubble)를 생산하였다. 생산된 초미세기포를 함유한 세척수는 압력 150 bar, 토출량 30 LPM 으로 도로 구조물 표면에 흡착된 분진을 고압세척 분사하여 제거하였다. 분석실험은 세척 전과 후로 구분하여 표면에 흡착한 분진을 ISO 8502-3의 표면 오염 측정방법을 적용하였으며, 테이프 흡착으로 분진 입자를 채취하였다. 수집된 테이프는 중량법과 소프트웨어 ImageJ를 적용하여 분진의 무게와 입자 개수에 대한 제거율을 산정하였다. 실험 결과, 타일 벽면 표면에 흡착된 분진 입자 개수는 세척 전과 후로 각각 3,063 ± 218 particles mL-1, 20 ± 5 particles mL-1, 중량은 580 ± 82 mg, 13 ± 4 mg 으로 나타났다. 콘크리트 구조물 표면에서의 입자개수는 세척 전과 후로 각각 8,105 ± 1,738 particles mL-1, 39 ± 6 particles mL-1이었으며, 중량은 1,448 ± 190 mg, 118 ± 32 mg으로 나타났다.

지하터널에서 주행하는 전동차의 하부에서 발생한 입자의 이동경로 예측 (Prediction of Trajectories of Particles Generated Underneath a Subway Train Running in An Underground Tunnel)

  • 이경란;김원근;육세진;우상희;김종범;배귀남;박형구;윤화현
    • 한국입자에어로졸학회지
    • /
    • 제11권1호
    • /
    • pp.21-28
    • /
    • 2015
  • In this study, the flow around a subway train running in an underground tunnel was numerically estimated. For the validation of the numerical results, the airflow velocity at a point underneath a subway train was measured using an ultrasonic anemometer. Then, the trajectories of particles generated at the contact points between the wheels and rails were numerically predicted. By considering the airflow velocity and particle trajectories, the space underneath the T-Car (trailer car) was expected to be appropriate for the room for the installation of a dust-removal system.

디젤엔진에서 배출되는 미세 입자의 크기 분포 (Submicrometer Particle Size Distribution of Emissions from Diesel Engines)

  • 김민철;권순박;이규원;김종춘;류정훈;엄명도
    • 한국대기환경학회지
    • /
    • 제15권5호
    • /
    • pp.657-665
    • /
    • 1999
  • Particulate matter produced by diesel engines is of concern to cngine manufactures because of its environmental impact. The majority of diesel particles are in the range of smaller than 1 ${\mu}{\textrm}{m}$. Because of their tiny volume, ultrafine diesel particles contribute very little to the total mass concentration which is currently regulated for automobile emissions. Ultrafinc particles are known to have deleterious effects upon human health cspecially because they penetrate deeply human respiratory tract and have negative effects on the health. In this study, the engine exhaust gas was diluted in a dilution tunnel and the particle size distribution was measured using the scanning mobility particel sizer system. Measurements of the number and the mass concentrations of the diesel exhaust were made under different engine ooperating conditions. The dilution sampling system provided a common basis for collection of the exhaust by cooling and diluting the source emission prior to the measurement. The measurement results showed that the particle size distributions of the exhaust from the diesel vehicles equipment with either heavy-duty or lignt-duty diesel engines, were similar in the particle size range of 0.08~0.2${\mu}{\textrm}{m}$.

  • PDF

겨울철 서울 내부순환로 도로상 초미세입자 오염의 공간분포 특징 (Spatial Distributions of On-road Ultrafine Particle Number Concentration on Naebu Express Way in Seoul during Winter Season)

  • 우대광;이승복;이승재;김진영;진현철;김태성;배귀남
    • 한국대기환경학회지
    • /
    • 제29권1호
    • /
    • pp.10-26
    • /
    • 2013
  • To understand the traffic emissions with high temporal and spatial resolutions on road, a mobile laboratory was developed. The objective of this study is to characterize on-road air pollution on Naebu express way surrounding the northern area of Seoul, Korea. We measured the number concentration of ultrafine particles larger than 5 nm and particle size distribution using a condensation particle counter and a fast mobility particle sizer, respectively on 3, 7, and 8 December 2009. The average ultrafine particle number concentration on the Naebu express way excluding tunnels was 126,000 particles/$cm^3$ and 4.2 times higher than that on internal road at Korea Institute of Science and Technology in Seoul, and more than twice higher than that measured on and at the arterial roads of Seoul in previous studies. The maximum ultrafine particle number concentration was observed at the tunnel sections. It was 232,000 particles/$cm^3$ and 1.8 times higher than average ultrafine particle number concentration for the other sections on Naebu express way. The ultrafine particle number concentration on the wider roads with higher traffic volume along the Han River was similar to that in the residential section, probably because of enhanced dilution effect in widely open environment. The size distribution of particles on the Naebu express way was highly fluctuated for a short duration. Ultrafine particles measured at the tunnel showed a bimodal size distribution with mode diameters of ~10 nm and ~50 nm. At the Han riverside section, ~10 nm particles appeared significantly compared with size distribution at the tunnel. This on-road measurement approach can be utilized to manage vehicle-related air pollution in urban area.

해안 유사에서 수체로의 플라스틱 입자 방출에 관한 실험적 연구 (Experimental study on release of plastic particles from coastal sediments to fluid body)

  • 황동욱;박용성
    • 한국수자원학회논문집
    • /
    • 제56권2호
    • /
    • pp.125-137
    • /
    • 2023
  • 지속적으로 증가하는 플라스틱의 사용으로 인하여 현재 해안·해양 환경에서 플라스틱을 찾기란 어렵지 않은 일이 되었다. 하천을 통해 해양으로 유출된 플라스틱 폐기물은 해안 지역에서 장기간 머물며, 파랑, 바람, 유사, 인간 활동 등과 같은 다양한 요인들과 상호작용하며 물리적·화학적 변화를 겪게 된다. 이에, 실험적 연구를 통하여 해안 유사에서 수체로의 플라스틱 입자 방출 과정을 고찰하고자 하였다. 본 연구는 고 레이놀즈 수를 가지는 왕복 흐름과 유사 이동을 구현하기 위한 왕복흐름발생장치를 제작하여 진행되었고, 세 가지의 크기를 가지는 매끈한 구형의 플라스틱 입자를 사용하였다. 실험 결과, 유사 내 플라스틱 입자의 방출은 유사 이동에 가장 큰 영향을 받았으며, 이는 흐름의 세기에 비례한다. 더불어, 입자가 작을수록 더 많은 입자가 방출되었다. 결과를 종합하여 입자의 방출을 결정하는 무차원 매개변수들의 임계값을 제시하였다.