• Title/Summary/Keyword: Tunnel particles

Search Result 85, Processing Time 0.025 seconds

Experimental and computational study on fluid flow-solid particles interaction associated with entrainment behavior of the particles in the industrial furnaces (산업용 로 내 고체 미립자의 거동 예측을 위한 유동-고체입자 간 비산에 관한 실험과 해석)

  • Lee, Hookyung;Eum, Minje;Choi, Sangmin
    • 한국연소학회:학술대회논문집
    • /
    • 2012.04a
    • /
    • pp.93-96
    • /
    • 2012
  • In the industrial furnaces or reactors, entrainment of the material particles is one of the important issues from the point of view of efficient material-use. The particles of solid phase which has submicron unit are easily entrained with gas phase as a reacting agent or product, and it causes a loss of the material. In this study, wind-tunnel experiment is carried out to interpret the distribution of the particles entrained along the tunnel length. Through CFD-based computational analysis of the experiment, availability of result from the CFD analysis associated with particle size distribution and gaseous velocity to practical system is evaluated.

  • PDF

Characterization of Summertime Aerosol Particles Collected at Subway Stations in Seoul, Korea Using Low-Z Particle Electron Probe X-ray Microanalysis

  • Kim, Bo-Wha;Jung, Hae-Jin;Song, Young-Chul;Lee, Mi-Jung;Kim, Hye-Kyeong;Kim, Jo-Chun;Sohn, Jong-Ryeul;Ro, Chul-Un
    • Asian Journal of Atmospheric Environment
    • /
    • v.4 no.2
    • /
    • pp.97-105
    • /
    • 2010
  • A quantitative single particle analytical technique, denoted low-Z particle electron probe X-ray microanalysis (low-Z particle EPMA), was applied to characterize particulate matters collected at two underground subway stations, Jegidong and Yangje stations, in Seoul, Korea. To clearly identify the source of the indoor aerosols in the subway stations, four sets of samples were collected at four different locations within the subway stations: in the tunnel; at the platform; near the ticket office; nearby outdoors. Aerosol samples collected on stages 2 and 3 ($D_p$: $10-2.5\;{\mu}m$ and $2.5-1.0\;{\mu}m$, respectively) in a 3-stage Dekati $PM_{10}$ impactor were investigated. Samples were collected during summertime in 2009. The major chemical species observed in the subway particle samples were Fe-containing, carbonaceous, and soil-derived particles, and secondary aerosols such as nitrates and sulfates. Among them, Fe-containing particles were the most popular. The tunnel samples contained 85-88% of Fe-containing particles, with the abundance of Fe-containing particles decreasing as the distances of sampling locations from the tunnel increased. The Fe-containing subway particles were generated mainly from mechanical wear and friction processes at rail-wheel-brake interfaces. Carbonaceous, soil-derived, and secondary nitrate and/or sulfate particles observed in the underground subway particles likely flowed in from the outdoor environment by human activities and the air-exchange between the subway system and the outdoors. In addition, since the platform screen doors (PSDs) limit air-mixing between the tunnel and the platform, samples collected at the platform at the Yangjae station (with PSDs) showed a marked decrease in the relative abundances of Fe-containing particles compared to the Jegidong station (without PSDs).

Chemical Composition of the Size-resolved Particles in Buk-Ak Tunnel

  • Ma, Chang-Jin;Hwang, Kyung-Chul;Kang, Gong-Unn;Tohno, Susumu
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.20 no.E2
    • /
    • pp.53-59
    • /
    • 2004
  • The roadway tunnels in urban areas give rise to problems such as a localized air pollution. Here, we report the results of a case study of an urban roadway tunnel measurement. The size-resolved particle sampling was carried out with a two 2-stage filter pack samplers and an Andersen impactor sampler at the center of Buk-Ak tunnel in November 2001. Particle Induced X-ray Emission (PIXE) was applied to determine the elemental composition of size-resolved particles divided into soluble and insoluble fractions. The Thermal/Optical Reflectance (TOR$^{(R)}$) method was also employed in analyzing of elemental carbon (EC) and organic carbon (OC). Mass concentrations of fine (< 1.2 ${\mu}{\textrm}{m}$) and coarse (> 1.2 ${\mu}{\textrm}{m}$) particles are 165 and 48 $\mu\textrm{g}$ m$^{-3}$ , respectively. Total elemental mass concentration (the sum of insoluble coarse, soluble coarse, insoluble fine, and soluble fine) is found to be 24$\mu\textrm{g}$ m$^{-3}$ and comprises only 11 % of total particle mass concentration. The concentrations of EC, OC, and mass show the clear dependency on particle size with the maximum between 0.1 and 0.43 ${\mu}{\textrm}{m}$ aerodynamic diameters. Total carbon (sum of EC and OC) accounts for approximately 70% of mass concentration.n.

Spatial Distribution of Air Pollution Level inside Roadway Tunnels in Urban Area (도시 자동차도로 터널 내부의 대기오염도 공간분포 특징)

  • Park, Bo-Eun;Lee, Seung-Bok;Lee, Dong-Hun;Lee, Seung Jae;Woo, Dae-Kwang;Choi, Jae-Hyun;Jin, Hyoun-Cher;Bae, Gwi-Nam;Yun, Seong-Taek
    • Particle and aerosol research
    • /
    • v.8 no.1
    • /
    • pp.17-28
    • /
    • 2012
  • Air pollution levels of gases and aerosol particles inside the Jeongneung and Hongjimun tunnels of the Naebu express way in Seoul were investigated through on-road measurement using a mobile emission laboratory (MEL) on February 8, 2011. The concentrations of $NO_x$, $CO_2$, number concentration of particles ranging 21-560 nm, and surface area of particles deposited on a human lung almost linearly increased with increasing distance from the tunnel entrance, and decreased rapidly before the tunnel exit. This trend was observed regardless of tunnel length and driving directions, which thought to be caused by semi-transverse ventilation facilities of the tunnels. The concentration increments per 1-m distance for $NO_x$, $CO_2$, deposited particle surface area, and number of particles ranging 21-560 nm were 0.61~0.80 ppb, 0.16~0.21 ppm, $0.20{\sim}0.29{\mu}m^2/cm^3$, and 117~192 particles/$cm^3$, respectively. Average pollution levels inside the two tunnels for $CO_2$, deposited particle surface area, and number of particles >5.6 nm ranged 681~748 ppm, $246{\sim}381{\mu}m^2/cm^3$, and $2.4{\sim}6.7{\times}10^5$ particles/$cm^3$, respectively. In case of $NO_x$, the maximum concentration exceeded 1 ppm. These pollution levels inside the tunnels are much higher than those at urban background sites. This result can be utilized as basic data to evaluate the effectiveness of present ventilation system for reducing the pollution level caused by vehicles inside the tunnels.

Experiment on Collection Characteristics of Sub micron Particles in Two-Stage Parallel-Plate Electrostatic Precipitators (2단 평행판 전기집진기의 서브마이크론 입자 포집특성 실험)

  • Oh, M.D.;Yoo, K.H.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.6 no.3
    • /
    • pp.237-246
    • /
    • 1994
  • Experimental data are reported for charging and collection of NaCl aerosols in the 0.03- to $0.2{\mu}m$-geometric-mean-diameter range in 2-stage parallel-plate electrostatic precipitators. The NaCl aerosols are generated with geometric standard deviation of about 1.74 and particle generation rate of about 10^9 particles/see by the constant output atomizer and injected into the air flow in the clean wind-tunnel. The 2-stage parallel-plate electrostatic precipitator installed in the test section of the wind-tunnel is operated with a positive corona discharge. The NaCl aerosols in the channel flow are sampled and transported to the aerosol particle number concentration measurement system by using the isoaxial sampling and transport system constructed based on the Okazaki and Willeke design. The aerosol particle number concentration measurement system measures the size distribution of submicrometer aerosols by an electrical mobility detection technique. It is confirmed from comparing the measured collection efficiencies in this study and the predicted ones by our previous theoretical analysis that the predicted collection efficiencies agree well with the experimental ones. It is also found from the comparison that below about $0.02{\mu}m$ all particles are not charged and the uncharged particles are not collected, and consequently 2-stage parallel-plate electrostatic precipitators are not suitable for that particle size range.

  • PDF

Evaluation of Dust Removal Efficiency on Roadway Structures Using Ultrafine Bubble Water Jet (초미세기포 water jet을 이용한 도로 시설물 분진 제거 효율 평가)

  • Kim, Hyun-Jin;Park, Il-gun
    • Clean Technology
    • /
    • v.27 no.1
    • /
    • pp.39-46
    • /
    • 2021
  • A road structure washing vehicle equipped with a 4 HP, 80 LPM ultrafine bubble generator was used to clean a tunnel wall and the surface of the surrounding structure, consisting of concrete and tiles, in a heavy traffic area around an apartment complex in the city. Ultrafine bubbles were generated by supplying air at 2 to 3 LPM and using a specially designed nozzle, whereas fine bubbles made by an impeller in a gas-liquid mixing self-priming pump were produced with an average diameter of 165.4 nm and 6.81 × 107 particles mL-1. Using a high pressure washer gun that can perform high-pressure cleaning at 150 bar and 30 LPM, ultrafine bubbles were used to wash dust adsorbed on the surface of the road structures. The experimental analysis was divided into before and after washing. The samples were analyzed by applying ISO 8502-3 to measure surface contamination of dust adsorbed on the surface. Using the transparent tape attached to the surface, the removal rate was calculated by measuring the weight of the dust, and the number of particles was calculated using the gravimetric method and the software, ImageJ. The results of the experiment showed that the number of dust particles adsorbed on the tile wall surface before and after washing were 3,063 ± 218 particles mL-1 and 20 ± 5 particles mL-1, respectively, with weights of 580 ± 82 mg and 13 ± 4 mg. Particles on the surface of the concrete structure before and after washing were 8,105 ± 1,738 particles mL-1 and 39 ± 6 particles mL-1, respectively, with weights of 1,448 ± 190 mg and 118 ± 32 mg.

Prediction of Trajectories of Particles Generated Underneath a Subway Train Running in An Underground Tunnel (지하터널에서 주행하는 전동차의 하부에서 발생한 입자의 이동경로 예측)

  • Lee, Kyung-Ran;Kim, Won-Geun;Yook, Se-Jin;Woo, Sang-Hee;Kim, Jong Bum;Bae, Gwi-Nam;Park, Hyung-Koo;Yoon, HwaHyeon
    • Particle and aerosol research
    • /
    • v.11 no.1
    • /
    • pp.21-28
    • /
    • 2015
  • In this study, the flow around a subway train running in an underground tunnel was numerically estimated. For the validation of the numerical results, the airflow velocity at a point underneath a subway train was measured using an ultrasonic anemometer. Then, the trajectories of particles generated at the contact points between the wheels and rails were numerically predicted. By considering the airflow velocity and particle trajectories, the space underneath the T-Car (trailer car) was expected to be appropriate for the room for the installation of a dust-removal system.

Submicrometer Particle Size Distribution of Emissions from Diesel Engines (디젤엔진에서 배출되는 미세 입자의 크기 분포)

  • 김민철;권순박;이규원;김종춘;류정훈;엄명도
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.15 no.5
    • /
    • pp.657-665
    • /
    • 1999
  • Particulate matter produced by diesel engines is of concern to cngine manufactures because of its environmental impact. The majority of diesel particles are in the range of smaller than 1 ${\mu}{\textrm}{m}$. Because of their tiny volume, ultrafine diesel particles contribute very little to the total mass concentration which is currently regulated for automobile emissions. Ultrafinc particles are known to have deleterious effects upon human health cspecially because they penetrate deeply human respiratory tract and have negative effects on the health. In this study, the engine exhaust gas was diluted in a dilution tunnel and the particle size distribution was measured using the scanning mobility particel sizer system. Measurements of the number and the mass concentrations of the diesel exhaust were made under different engine ooperating conditions. The dilution sampling system provided a common basis for collection of the exhaust by cooling and diluting the source emission prior to the measurement. The measurement results showed that the particle size distributions of the exhaust from the diesel vehicles equipment with either heavy-duty or lignt-duty diesel engines, were similar in the particle size range of 0.08~0.2${\mu}{\textrm}{m}$.

  • PDF

Spatial Distributions of On-road Ultrafine Particle Number Concentration on Naebu Express Way in Seoul during Winter Season (겨울철 서울 내부순환로 도로상 초미세입자 오염의 공간분포 특징)

  • Woo, Daekwang;Lee, Seung-Bok;Lee, Seung Jae;Kim, Jin Young;Jin, Hyun Chul;Kim, Taesung;Bae, Gwi-Nam
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.29 no.1
    • /
    • pp.10-26
    • /
    • 2013
  • To understand the traffic emissions with high temporal and spatial resolutions on road, a mobile laboratory was developed. The objective of this study is to characterize on-road air pollution on Naebu express way surrounding the northern area of Seoul, Korea. We measured the number concentration of ultrafine particles larger than 5 nm and particle size distribution using a condensation particle counter and a fast mobility particle sizer, respectively on 3, 7, and 8 December 2009. The average ultrafine particle number concentration on the Naebu express way excluding tunnels was 126,000 particles/$cm^3$ and 4.2 times higher than that on internal road at Korea Institute of Science and Technology in Seoul, and more than twice higher than that measured on and at the arterial roads of Seoul in previous studies. The maximum ultrafine particle number concentration was observed at the tunnel sections. It was 232,000 particles/$cm^3$ and 1.8 times higher than average ultrafine particle number concentration for the other sections on Naebu express way. The ultrafine particle number concentration on the wider roads with higher traffic volume along the Han River was similar to that in the residential section, probably because of enhanced dilution effect in widely open environment. The size distribution of particles on the Naebu express way was highly fluctuated for a short duration. Ultrafine particles measured at the tunnel showed a bimodal size distribution with mode diameters of ~10 nm and ~50 nm. At the Han riverside section, ~10 nm particles appeared significantly compared with size distribution at the tunnel. This on-road measurement approach can be utilized to manage vehicle-related air pollution in urban area.

Experimental study on release of plastic particles from coastal sediments to fluid body (해안 유사에서 수체로의 플라스틱 입자 방출에 관한 실험적 연구)

  • Hwang, Dongwook;Park, Yong Sung
    • Journal of Korea Water Resources Association
    • /
    • v.56 no.2
    • /
    • pp.125-137
    • /
    • 2023
  • In marine environments, plastics have become more abundant due to increasing plastic use. Especially, in coastal regions, particles may remain for a long time, and they interact with flows, wind, sand and human activities. This study aimed thus to observe how plastic debris interacts with and escape from sediments. A series of experiments were conducted in order to gain a better understanding of particle release from coastal sediments into water body. An oscillating water tunnel was built for the experiments, and used to generate oscillatory flows of relatively high Reynolds number and induce sediment transport. Spherical plastic particles of three different sizes was used in lieu of plastic debris in environments. It was observed that release of the particles was directly related to change of bedform, which is in turn determined by the flow condition. Also smaller particles tend to escape the sediment more readily. Critical values for dimensionless parameters are proposed.