• Title/Summary/Keyword: Tunnel Noise

Search Result 424, Processing Time 0.027 seconds

Impact of Soundproofing Wall of Tunnel on Particulate Matter and Noise (서울시 터널 내 방음벽 설치가 입자상 물질 농도 및 소음 수준에 미치는 영향)

  • Cho, Hyun-Woo;Lee, Ji-Yeon;Liu, Xiaoshan;Lee, Ki-Young
    • Journal of Environmental Health Sciences
    • /
    • v.36 no.5
    • /
    • pp.411-417
    • /
    • 2010
  • The Seoul metropolitan government has installed soundproofing walls in road tunnels to improve the tunnel environment for pedestrians. To evaluate the efficiency of these soundproofing walls, we measured noise levels and concentrations of $PM_{2.5}$ and ultrafine particles (UFP) in tunnels with or without these walls. Although noise and UFP levels were significantly lower in the tunnels with soundproofing walls, $PM_{2.5}$ levels were significantly higher: but were significantly lowered by use of a ventilation system. When $PM_{2.5}$ and noise levels were simultaneously measured in a tunnel with soundproofing wall, noise level was significantly reduced but $PM_{2.5}$ level was significantly higher. It is concluded that the soundproofing wall can protect pedestrians from noise, but not PM. Installation of a ventilation system is recommended for protection of pedestrians in tunnels with soundproofing walls.

Overview of Environmental Impact Assessment and Environmental Protection Technology in Tunnel Construction (터널 건설에 따른 환경영향 평가 및 대응기술 개발 방향)

  • Bae Gyu-Jin
    • 한국터널공학회:학술대회논문집
    • /
    • 2005.04a
    • /
    • pp.63-74
    • /
    • 2005
  • The environmental influence in tunnel construction is the drying of the ground water, the drop of the ground water level, and noise and vibration by tunnel excavation. The environmental influence can cause the change of natural ecosystem and the source of popular complaints. In case of popular complaints, the tunnel construction can be stopped or the construction period can be extended. Also, the financial loss may be reached to hundreds of billions won. The technology development to minimize the environmental influence in the tunnel construction is very important in order to control popular complaints and to preserve ecosystem. It should be required the investigation, the evaluation, and the assessment of environmental impact to reduce environmental influence in the tunnel construction. The objective of this research is to review the environmental impact assessment in Korea and to introduce the environmental protection technology which minimizes the environmental influence generated in the tunnel construction.

  • PDF

Experiments for the Acoustic Source Localization in 2D Cavity Flow (2차원 공동 유동에서의 소음원 위치 판별을 위한 실험적 연구)

  • Lee, Jaehyung;Park, Kyu-Chol;Choi, Jong-Soo
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.14 no.12
    • /
    • pp.1241-1248
    • /
    • 2004
  • This paper presents an acoustic source localization technique on 2D cavity model in flow using a phased microphone array. Investigation was performed on cavity flows of open and closed types. The source distributions on 2D cavity flow were investigated in an anechoic open-jet wind tunnel. The array of microphones was placed outside the flow to measure the far field acoustic signals. The optimum sensor placement was decided by varying the relative location of the microphones to improve the spatial resolution. Pressure transducers were flush-mounted on the cavity surface to measure the near-filed pressures. It is shown that the propagated far field acoustic pressures are closely correlated to the near-field pressures and their spectral contents are affected by the cavity parameter L/D.

Source Localization of Induced Noise from a Rolling Wheel of Ground Vehicle (회전하는 바퀴 주위의 유동소음원)

  • Kwon Oh-Sub;Jang Keun-Jeoung;Lee Seungbae
    • Proceedings of the KSME Conference
    • /
    • 2002.08a
    • /
    • pp.759-762
    • /
    • 2002
  • Automobile aeroacoustics Is a developing area of technology where experimental and theoretical tools are being continuously refined to understand, analyze and modify the noise-generating mechanisms in the vehicle flow. Main sources of ground vehicle exterior noise are the tires (tire/road interaction) and the unsteady flow field around the vehicle. In this study, the sound source localization of a rolling tire was applied to the measurement of radiated sound by using an acoustic mirror system. A possible flow pattern that develops is suggested based on detailed wind tunnel investigations with a rotating wheel in contact with a moving belt.

  • PDF

Acoustic Source Localization in 2D Cavity Flow using a Phased Microphone Array (마이크로폰 어레이를 이용한 2차원 공동 유동에 대한 소음원 규명)

  • 이재형;최종수;박규철
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.05a
    • /
    • pp.701-708
    • /
    • 2003
  • This paper presents an acoustic source localization technique on 2D cavity model in flow using a phased microphone way. Investigation was performed on cavity flows of open and closed types. The source distributions on 2D cavity flow were investigated in anechoic open-jet wind tunnel. The array of microphones was placed outside the flow to measure the far field acoustic signals. The optimum sensor placement was decided by varying the relative location of the microphones to improve the spatial resolution. Pressure transducers were flush-mounted on the cavity surface to measure the near-filed pressures. It is shown that the propagated far field acoustic pressures are closely correlated to the near-field pressures. It is also shown that their spectral contents are affected by the cavity parameter L/D.

  • PDF

Aeolian Noise from High Voltage Insulators (초고압 송전용 애자의 풍소음 특성)

  • Chu, Jang-Hee;Kim, Sang-Beom;Shin, Koo-Yong;Lee, Seong-Doo;Lee, Dong-Il
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.06a
    • /
    • pp.1842-1847
    • /
    • 2000
  • In this paper, a review is attempted for understanding of aeolian noise from high voltage insulators and their aerodynamic noise characteristics were investigated using the low noise wind tunnel. The noise from the insulators was dependent upon the wind speed and their orientation relative to the wind direction. The noise spectrum revealed sharp peak which was found the cavity resonance frequency.

  • PDF

Tunnel Safety Diagnosis in Near-excavation by In-depth Inspection of Tunnel (기존터널 안전진단 결과를 통한 근접시공 시 터널 안정성 평가)

  • Kim, Seok-Jae;Kim, Min-Seok;Kim, Jun-Chul;Yoo, Young-Il;Oh, Joung-Bae;Oh, Sae-Joon
    • Tunnel and Underground Space
    • /
    • v.16 no.4 s.63
    • /
    • pp.347-356
    • /
    • 2006
  • We analyzed case studies doing in-depth inspection of tunnel to maintain safety of existing tunnel in constructing new tunnel near to a existing tunnel with single track. Futhermore, We accomplished in-depth inspection of existing tunnel and numerical analysis. We suggested remedies to security safety of existing tunnel. We applied line drilling and pre-large hole boring method not to have an effect on existing tunnel and convinced the safety of existing tunnel from blast-vibration and blast-noise of numerical analysis. We planed to install basset system to measure displacement of existing tunnel according to excavating new tunnel.

The Development of Soundproof System for the Blasting Noise Reduction in Tunnels (터널 발파소음 감쇠를 위한 방음시스템 개발)

  • 노상림;김욱영;조영천;이상필;유지영
    • Explosives and Blasting
    • /
    • v.22 no.1
    • /
    • pp.67-74
    • /
    • 2004
  • Blasting in urban area has become a serious issue in our living because it causes inconvenience to the resident living by construction area. Therefore, the practical solution and the better method for reducing blasting noise are highly required. However, finding practical solutions for the blasting noise is very difficult due to the lack of basic data and insufficient existing research. In order to overcome the limitation of existing sound barrier, we applied a new material to multi-layer soundproof system in the construction site, Kuksabong Tunnel in Yang Nyung-Ro. The statistical method was used to analyze blasting noise data. Through all these processes, it was verified that the soundproof system in this study was very effective method to decrease blasting noise.

Experimental study on reduction of impulsive noise generating at exit of high-speed railway tunnel (고속철도 터널출구에서 발생하는 충격성 소음의 저감을 위한 실험적 연구)

  • Kim, Hui-Dong;Setoguchi, Toshiaki
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.20 no.7
    • /
    • pp.2375-2385
    • /
    • 1996
  • As a compression wave is emitted from a duct, an impulsive wave generates and causes an impulsive noise that is at present a serious environmental noise pollution. In order to clarify the acoustic characteristics of the noise and to reduce their pressure levels, a series of model experiments were conducted on the impulsive waves emitted from an open end of a shock tube. The impulsive waves with various intensities were obtained by controlling the operation pressure ratio of the shock tube. Various kinds of silencers such as the exit boxes with baffle plates, were applied to the duct exit to reduce the impulsive noises. The effects of geometry of silencers and shock Mach number on the noise reduction were clarified. From the measurements of sound pressure level, it was found that installing the baffle plate into the exit box is effective in lowering the noise level at far fields, and that the recommendable geometries of silencer are L/D=1, H/D=1 and H/D=0.75.

Measuring performance and SPL of refrigerator fan using anechoic fan tester (무향팬테스터를 이용한 냉장고용 팬 성능/소음 측정)

  • Jeoung, Jeoung-Kyo;Lee, Jun-Hwa;Joo, Jae-Man;Kang, Jung-Hun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.253-256
    • /
    • 2004
  • Acoustical noise at low frequency range (below 500Hz) of refrigerator result from fans which are inside of the refrigerator. In generally to evaluate and apply to refrigerator it is recommended that acoustical noise and fluidic performance of the fan were measured simultaneously. To do that twin-room type anechoic wind tunnel was needed. But constructing twin room type anechoic wind tunnel was very expensive and estimation of small refrigerator fan performance was not easy. So in this paper we composed anechoic fan tester. A successful noise and performance measurement was performed using the anechoic fan tester. Existing 22 kinds of refrigerator fan were investigated and mapped into one database. Refrigerator duct pressure resistance were measured and reflected into the fan database to find out appropriate fan. Through the application of fan database, the refrigerator became less noise compared to current one and these data shows what is the best way to reduce fan noise.

  • PDF