• Title/Summary/Keyword: Tuning parameter

Search Result 515, Processing Time 0.039 seconds

Resonance Frequency and Quality Factor Tuning in Electrostatic Actuation of Nanoelectromechanical Systems

  • Kim, Dong-Hwan
    • Journal of Mechanical Science and Technology
    • /
    • v.19 no.9
    • /
    • pp.1711-1719
    • /
    • 2005
  • In an electro statically actuated nanoelectromechanical system (NEMS) resonator, it is shown that both the resonance frequency and the resonance quality (Q) factor can be manipulated. How much the frequency and quality factor can be tuned by excitation voltage and resistance on a doubly-clamped beam resonator is addressed. A mathematical model for investigating the tuning effects is presented. All results are shown based on the feasible dimension of the nanoresonator and appropriate external driving voltage, yielding up to 20 MHz resonance frequency. Such parameter tuning could prove to be a very convenient scheme to actively control the response of NEMS for a variety of applications.

A GA based on-line tuning of robust minimax I-PD controller with penalty on manipulated variable

  • Kawabe, Tohru;Tagami, Takanori;Katayama, Tohru
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1995.10a
    • /
    • pp.428-431
    • /
    • 1995
  • In this paper we propose an on-line tuning method by using genetic algorithm for robust minimax I-PD controller based on new criterion. The new criterion is the Integral of Squared Error (ISE) with a penalty of the derivative of manipulated variable. The work focuses on robust tuning of I-PD controller's parameters in the presence of plant parameter uncertainty. The result of several simulation studies are provided to illustrate the performance of this robust tunig method.

  • PDF

Overload control mechanism by parameter tuning in FDDI networks (FDDI 네트워크의 파라미터 튜닝에 의한 과부하 제어 메카니즘)

  • 이준호;김경신;강문식;송명렬;이상배
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.32A no.4
    • /
    • pp.32-39
    • /
    • 1995
  • In this paper, a timer thresholds tuning algorithm is proposed, satisfying the required response time for traffic with time-critical applications and asynchronous traffic in FDDI network. Under light and medium load, priorities and timer thresholds play a minor role for medium access control. In these cases all quenes are served exhaustively with a ver high service probability and the packet loss probability approaches almost zero. Under overload condition, however, the performance of the FDDI Network is completely determined by the selection of the timer thresholds. The timer thresholds tuned by mathematical results is confirmed by simulation results using SIMAN/UNIX package. The allocation of guaranteed bandwidth can be controlled easily by tuning the timer thresholds according to the proposed rules.

  • PDF

A Practical Power System Stabilizer Tuning Method and its Verification in Field Test

  • Shin, Jeong-Hoon;Nam, Su-Chul;Lee, Jae-Gul;Baek, Seung-Mook;Choy, Young-Do;Kim, Tae-Kyun
    • Journal of Electrical Engineering and Technology
    • /
    • v.5 no.3
    • /
    • pp.400-406
    • /
    • 2010
  • This paper deals with parameter tuning of the Power System Stabilizer (PSS) for 612 MVA thermal power plants in the KEPCO system and its validation in a field test. In this paper, the selection of parameters, such as lead-lag time constants for phase compensation and system gain, is optimized using linear and eigenvalue analyses. This is then verified through the time-domain transient stability analysis. In the next step, the performance of PSS is finally verified by the generator's on-line field test. After the field test, measured and simulated data are also compared to prove the effectiveness of the models used in the simulations.

Flutter Analysis Model Tuning of KC-100 Aircraft with the Ground Vibration Test Results (지상진동시험결과를 이용한 KC-100 항공기의 플러터 해석모델 보정)

  • Paek, Seung-Kil;Choi, Yong-Joon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2011.10a
    • /
    • pp.191-195
    • /
    • 2011
  • The airframe ground vibration tests were conducted on the KC-100 aircraft according to the regulation requirement, KAS 23.629(a)(2) and the modal characteristics for the target modes were measured. To make FE model tuning, a design sensitivity approach with engineering judgment was implemented using MSC/Nastran and Attune, a genetic algorithm based parameter optimization software. Based on the comparison between initial prediction and test results, design variables such as beam cross-sectional properties and spring stiffnesses were devised. As the results, the correlation of the FE model to the GVT results was made appropriately, meeting the goal of matching the target frequencies within 5%.

  • PDF

Self-Tuning Control of Multivariable System (다변수 시스템의 자기동조제어)

  • Bae, Jong-Il;Lee, Dong-Cheol
    • Proceedings of the KIEE Conference
    • /
    • 1998.07b
    • /
    • pp.592-594
    • /
    • 1998
  • In the single-input and single-output system, the parameter of plant is scalar polynomial, but in the multiple input and multiple output, it accompanies, being matrix polynomial, the consideration of observable conrolability index or problems of non-commutation in matrix polynomial as well as degree, and it is more complex to deal with. Therefore, it is thought that a full reserach on the single-input and single-output system is not made. This reserach propose that problems of minimum variance self-tuning regulator of multivariable system and pole placement self-tuning regulator.

  • PDF

Field test Results for PSS Parameter Tuning in Seo-Incheon Power Plant (서인천 복합화력 발전소의 PSS 파라메터 Tuning)

  • Shin, Jeong-Hoon;Kim, Tae-Kyun
    • Proceedings of the KIEE Conference
    • /
    • 1998.07c
    • /
    • pp.1143-1146
    • /
    • 1998
  • Static excitation systems with high gain and fast response times greatly aid transient stability. but at the same time tend to reduce small signal stability. The objective of the power system stabilizer(PSS) control is to provide a positive contribution to damping of the generator rotor angle swings, which are in a broad range of frequencies in the power system. Therefore, this paper shows the field test results for the GE's EX2000 PSS tuning on units at Seo-Incheon power plant. The test is to verify that the PSS response meets GE's design, criteria. The responses of generator terminal voltage, active power, field voltage and current were analyzed and PSS gain was tuned by 10 finally.

  • PDF

Auto-tuning of boiler drum level controller in Thermal Power Plant (화력 발전소 보일러 드럼수위 제어기의 자동 동조)

  • Lee, J.H.;Joo, H.Y.;Byun, H.S.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07d
    • /
    • pp.2584-2586
    • /
    • 2000
  • A drum level control is one of the most important control systems in thermal power plant. The control objective of drum level of boiler in thermal power plant is to maintain drum level at constant set-point regardless of disturbance such as main steam flow. The implemented drum level controller is the cascade PI controller. The important factor in drum level controller is the parameters of two PI controllers. The tuning of PI controller parameter is tedious and time-consuming job. In this paper, the relay feedback Ziegler - Nichols tuning method extended to auto-tune cascade PI drum level controller. Finally, the simulation result using boiler model in Power Plant shows the validity of auto-tuned cascade PI controller.

  • PDF

A Study on the Parameters Tuning Method of the Fuzzy Power System Stabilizer Using Genetic Algorithm and Simulated Annealing (혼합형 유전 알고리즘을 이용한 퍼지 안정화 제어기의 계수동조 기법에 관한 연구)

  • Lee, Heung-Jae;Im, Chan-Ho
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.49 no.12
    • /
    • pp.589-594
    • /
    • 2000
  • The fuzzy controllers have been applied to the power system stabilizer due to its excellent properties on the nonlinear systems. But the design process of fuzzy controller requires empirical and heuristic knowledge of human experts as well as many trial-and-errors in general. This process is time consuming task. This paper presents an parameters tuning method of the fuzzy power system stabilizer using the genetic algorithm and simulated annealing(SA). The proposed method searches the local minimum point using the simulated annealing algorithm. The proposed method is applied to the one-machine infinite-bus of a power system. Through the comparative simulation with conventional stabilizer and fuzzy stabilizer tuned by genetic algorithm under various operating conditions and system parameters, the robustness of fuzzy stabilizer tuned by proposed method with respect to the nonlinear power system is verified.

  • PDF

A Analysis on the Effect of the Controller Design due to Performance Index (평가지표에 따른 제어기 설계 영향 분석)

  • Yoo, Hang-Youal;Lee, Jung-Kuk;Lee, Keum-Won;Lee, Jun-Mo
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.05a
    • /
    • pp.90-94
    • /
    • 2004
  • Among various modern control theories, PID control has been well used for several decades. PID algorithms needs son tuning methods are used for selecting PID parameters. But in some cases various kinds of performance indices are used instead of well-known tuning rules, and so variable type of performance index must be tested so that controllers, output characteristics and disturbance rejection property meets some specifications. In this paper, linear conbinational type of performance using error signal, time, control input and robustness is used to the PID control of air conditioning system. By the 2 DOF PID parmeters minimizing perfromacne index, controllers, output characteristics and robustness properties are analyzed. Simulations are done with MATLAB m file and mdl files.

  • PDF