• Title/Summary/Keyword: Tubular membrane

Search Result 189, Processing Time 0.028 seconds

A feasibility study of a pilot scale two-phase anaerobic digestion with ultra filtration for the treatment of garbage leachate (음식물 탈리액 처리를 위한 파일럿 규모의 막결합형 2상 혐기성 소화 공정 가능성 평가)

  • Lee, Eun-young;Heo, Ahn-hee;Kim, Hyung-kuk;Kim, Hee-jun;Bae, Jae-ho
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.23 no.5
    • /
    • pp.539-545
    • /
    • 2009
  • A feasibility of a pilot scale two-phase anaerobic digestion with ultra filtration system treating garbage leachate were evaluated. The treatment system consisted of a thermophilic acidogenic reactor, a mesophilic methanogenic reactor, and an UF membrane. The average COD removal efficiency of the treatment system was 95% up to the OLR of 3.1 g COD/L/d. The higher COD removal efficiency with membrane unit resulted from the removal of some portion of soluble organics by membrane as well as particulate materials. When the membrane unit was in operation, bulk liquid in acidogenic and methanogenic reactors was partially interchanged, which maintained the acidogenic reactor pH over 5.0 without external chemical addition. Also, with the production of methane in the acidogenic reactor, the organic loading rate of the methanogenic reactor reduced. The initial flux of the membrane unit was $50{\sim}60L/m^2/hr$, but decreased to $5 L/m^2/hr$ after 95 days of operation due to clogging caused by particulate materials such as fibrous materials in garbage leachate. To prevent clogging caused by particulate materials, a pretreatment system such as screening is required. With the improvement with membrane unit operation, the two-phase anaerobic digestion with ultra filtration system is expected to have the possibility of treating garbage leachate.

Application in Ultrafiltration and Reverse Osmosis Module Set with Acrylic Wastewater Pretreated by Coagulation-Filtration-Neutralization Process (응집-여과-중화 공정에 의해 전처리된 아크릴 폐수의 한외여과와 역삼투 모듈 조합 공정에의 적용)

  • Lee, Kwang-Hyun;Kang, Byung-Chul;Lee, Jong-Baek
    • Membrane Journal
    • /
    • v.18 no.1
    • /
    • pp.1-6
    • /
    • 2008
  • After membrane fouling factors in acrylic wastewater were minimized by pretreatment process accompanied with coagulation-filtration-neutralization, it was utilized in UF/RO process. After composing of ultrafiltration and reverse osmosis module set according to types and kinds of membrane, the separation characteristics were examined with the variation temperature and pressure using pretreated acrylic wastewater by membrane module sets. It was found that permeate flux of UF module in module set 4 was about two${\sim}$three times larger than that of UF module in module set 1. Final quantity of permeate from the module set 2 and module set 3 combined with tubular module was shown very good result. It was shown that the removal efficiency of TDS, T-N and COD was very low and was not dependent on the variation of temperature and pressure in all UF modules. The removal efficiency of TDS, T-N and COD was very excellent in RO module. Final water quality of acrylic wastewater was satisfied with effluent allowances limit and membrane module sets were ascertained to reuse wastewater.

Advanced Water Treatment of High Turbidity Source by Hybrid Process of Ceramic Microfiltration and Activated Carbon Adsorption: Effect of Organic Materials in $N_2$-back-flushing (세라믹 정밀여과 및 활성탄 흡착 혼성공정에 의한 고탁도 원수의 고도정수처리: 질소 역세척 시 유기물의 영향)

  • Park, Jin-Yong;Park, Gil-Yong
    • Membrane Journal
    • /
    • v.19 no.3
    • /
    • pp.203-211
    • /
    • 2009
  • In this study, we used the hybrid module that was composed of granular activated carbons (GAC) packing between module inside and outside of tubular ceramic microfiltration membrane for advanced drinking water treatment. Instead of natural organic matters (NOM) and fine inorganic particles in natural water source, modified solution was prepared with humic acid and kaolin. $N_2$-back-flushing of 10 sec was performed per every period of 10 min to minimize membrane fouling and to improve permeate flux (J). As a result, resistance of membrane fouling ($R_f$) decreased and J increased as concentration of humic acid changed from 10 mg/L to 2 mg/L step by step, and finally the highest total permeate volume ($V_T$) could be obtained at 2 mg/L. Then, treatment efficiencies of turbidity and $UV_{254}$ absorbance were excellent above 99.36% and 97.19%, respectively, but that of $UV_{254}$ absorbance for only microfiltration without GAC at 10 mg/L of humic acid was decreased a little as 90.84%.

Feasibility study for blind-bolted connections to concrete-filled circular steel tubular columns

  • Goldsworthy, H.M.;Gardner, A.P.
    • Structural Engineering and Mechanics
    • /
    • v.24 no.4
    • /
    • pp.463-478
    • /
    • 2006
  • The design of structural frameworks for buildings is constantly evolving and is dependent on regional issues such as loading and constructability. One of the most promising recent developments for low to medium rise construction in terms of efficiency of construction, robustness and aesthetic appearance utilises concrete-filled steel tubular sections as the columns in a moment-resisting frame. These are coupled to rigid or semi-rigid connections to composite steel-concrete beams. This paper includes the results of a pilot experimental programme leading towards the development of economical, reliable connections that are easily constructed for this type of frame. The connections must provide the requisite strength, stiffness and ductility to suit gravity loading conditions as well as gravity combined with the governing lateral wind or earthquake loading. The aim is to develop connections that are stiffer, less expensive and easier to construct than those in current use. A proposed fabricated T-stub connection is to be used to connect the beam flanges and the column. These T-stubs are connected to the column using "blind bolts" with extensions, allowing installation from the outside of the tube. In general, the use of the extensions results in a dramatic increase in the strength and stiffness of the T-stub to column connection in tension, since the load is shared between membrane action in the tube wall and the anchorage of the bolts through the extensions into the concrete.

Concentration of Fresh Gel from Aloe vera L. by Using Ultrafiltration Process (한외여과 공정에 의한 알로에 베라 겔 농축)

  • Baek, Jin-Hong;Kim, Sung-A;Lee, Shin-Young
    • KSBB Journal
    • /
    • v.23 no.2
    • /
    • pp.169-176
    • /
    • 2008
  • The concentration of fresh gel from Aloe vera L. by using ulfrafiltration (UF) process was investigated and analyzed. The two membranes (organic and ceramic) with different molecular weight cut-off (MWCO) and modules (flat sheet and tubular) was used. Under optimum operation conditions, ceramic (zirconium dioxide) tubular membrane with MWCO of 50 kDa resulted in higher flux, less fouling, more turbid, higher total solid, higher polysaccharide and less aloin content. Optimum operation conditions were transmembrane pressure of 1.0 bar, feed velocity of 240 L/hr and temperature of $23^{\circ}C$. Volume concentration factor of aloe gel was 3.13 at permeate flux of $51.1\;L/m^2{\cdot}hr$ after processing time of 1.66 hr. Aloin in fresh aloe gel by UF process was effectively removed as permeate and bioactive polysaccharide content was 2.1 times higher than that of fresh aloe gel. These results allowed a very good level of concentration degree and polysaccharide content. Thus, ultrafiltration process of this study was suitable for the concentration of fresh aloe gel though the aloe concentrate showed both the viscosity decrease and partially separation of liquid layer during storage at $4^{\circ}C$.

Bronchoalveolar Lavage of Pneumocystis carinii Pneumonia: Cytological and Ultrastructural Features (Pneumocystis carinii 폐렴의 기관지 폐포세정액: 세포학적 및 전자현미경적 소견)

  • Kwon, Kun-Young;Yun, Cheol-Hee;Kim, Sang-Pyo;Park, Kwan-Kyu;Chang, Eun-Sook
    • The Korean Journal of Cytopathology
    • /
    • v.5 no.1
    • /
    • pp.1-9
    • /
    • 1994
  • The cytological and ultrastructural findings of Pneumocystis carinii(PC) obtained from rats by bronchoalveolar lavage (BAL) are described. All developmental forms of the PC organisms were obtained in the lavage fluid. Papanicolaou stain revealed conglomeration of PC as a foamy cast. The cystic walls of PC were well identified on Gomori's methenamine silver stain. Trophozoites and intracystic bodies were stained by Giemsa and Diff-Quik techniques. Some PC organisms were seen within the alveolar macrophages. Ultrastructurally, the cysts were almost circular in shape, and were nearly devoid of surface tubular extensions. The wall of the cyst was composed of an unit membrane, an intermediate electron lucent layer and an external electron dense layer The cysts frequently contained intracystic bodies, so called sporozoites. Occasionally empty or collapsed cysts with no intracystic bodies, and precysts were found. Trophozoites were variable in size and shape with abundant tubular extensions along the single electron dense pellicle. BAL is a useful method for concentrating the various morphologic forms of PC organisms, and is a rapid diagnostic method for PC pneumonia.

  • PDF

Effects of herbicide butachlor on Rhodospirillum rubrum KS-301 (Rhodospirillum rubrum KS-301에 미치는 제초제 butachlor의 영향)

  • 이경미;이현순
    • Korean Journal of Microbiology
    • /
    • v.27 no.3
    • /
    • pp.285-290
    • /
    • 1989
  • The biololgical effect of the preemergence rice field herbicide, butachlor(commercial name, Machete) on purple nonsulfur photosynthetic bacterium Rhodospirillum rubrum KS-301 has been studied under cultural conditions. Bacterial growth showed a tendency to decline according to the degree of the concentration of butachlor until $10^{-3}$ M and slmost stopped at $10^{-2}$M. The growth inhibitory action at $10^{-3}$M of butachlor was evident (4.2-18.7% inhibition of growth rate) but had little effect in nitrogen fixation. Conversely, there was a little enhancement effect(1%) in pyruvate, dinitrogen gas growing cultures. At concentration of $10^{-3}$ M, instead of spiral form, rod shapes were observed through phase contrast microscope and instead of vesicular intracytoplasmic membrane, irregular tubular forms were observed through electron microscope. Alkaline pH value slightly reversed tha inhibitory action of butachlor.

  • PDF

Tubular Type Direct Methanol Fuel Cell for in situ NMR Diagnosis (In Situ NMR 진단용 원통형 직접 메탄올 연료전지)

  • Joh, Han-Ik;Um, Myung-Sup;Han, Kee-Sung;Han, Oc-Hee;Ha, Heung-Yong;Kim, Soo-Kil
    • Journal of the Korean Electrochemical Society
    • /
    • v.12 no.4
    • /
    • pp.329-334
    • /
    • 2009
  • This study is to develop a fuel cell system applicable to an in situ NMR (Nuclear magnetic resonance) diagnosis. The in situ NMR can be used in real time monitoring of various reactions occurring in the fuel cell, such as oxidation of fuel, reduction of oxygen, transport phenomena, and component degradation. The fuel cell for this purpose is, however, to be operated in a specifically designed tubular shape toroid cavity detector (TCD), which constrains the fuel cell to have a tubular shape. This may cause difficulties in effective mass transport of reactants/products and uniform distribution of assembly pressure. Therefore, a new flow field designed in a particular way is necessary to enhance the mass transport in the tubular fuel cell. In this study, a tubular-shaped close-type flow field made of non-magnetic material is developed. With this flow field, oxygen is effectively delivered to the cathode surface and the produced water is readily removed from the membrane-electrode assembly to prevent flooding. The resulting DMFC (direct methanol fuel cell) outperforms the open-type flow field and exhibits $36\;mW/cm^2$ even at room temperature.

Hybrid Water Treatment of Tubular Ceramic MF and Photocatalyst Loaded Polyethersulfone Beads : Effect of Organic Matters, Adsorption and Photo-oxidation at Nitrogen Back-flushing (관형 세라믹 정밀여과와 광촉매 첨가 PES 구의 혼성 수처리 : 질소 역세척 시 유기물 및 흡착, 광산화의 영향)

  • Hong, Sung Taek;Park, Jin Yong
    • Membrane Journal
    • /
    • v.23 no.1
    • /
    • pp.61-69
    • /
    • 2013
  • The effect of humic acid (HA), and the roles of microfiltration (MF), PES (polyethersulfone) beads adsorption, and photo-oxidation were investigated in hybrid process of ceramic MF and PES beads loaded with titanium dioxide ($TiO_2$) photocatalyst for advanced drinking water treatment. Those were compared and studied in viewpoints of membrane fouling resistance ($R_f$), permeate flux (J), and total permeate volume ($V_T$). Because membrane fouling increased dramatically as decreasing HA, $R_f$ increased and J decreased, and finally $V_T$ was the highest at 2 mg/L HA. In the experiment to investigate the roles of photo-oxidation and adsorption at humic acid 4 mg/L and 6 mg/L. In both conditions, $R_f$ was the lowest and $V_T$ was the highest in MF + $TiO_2$ + UV process. The average treatment efficiencies of turbidity and dissolved organic matters were the highest in MF + $TiO_2$ + UV process, too.

Improvement of Fouling in Membrane Separation Process for Leachate Treatment using Ultrasound(I) : Analysis of Ultrasonic Parameters (초음파를 이용한 침출수 처리를 위한 막분리 공정의 막힘현상 개선(I) : 초음파의 영향인자 평가)

  • Kim, Seok-Wan;Lim, Jae-Lim;Lee, Jun-Geol
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.28 no.2
    • /
    • pp.197-206
    • /
    • 2006
  • This study evaluated the effect of ultrasonic irradiation on improving the flux and cleaning efficiency in membrane process which is widely applied for the treatment of landfill leachate. The experiments on improvement of membrane flux according to the types of membranes(hallowfiber microfiltration, MF and tubular ultrafiltration, UF) were performed with changing frequency($40{\sim}120$ kHz), intensity ($200{\sim}500$ W) and irradiation time of ultrasound as well us operation pressure($0.1{\sim}2.3kg/cm^2$). Membrane was fouled for the first 50 min with primary treated leachate and then the change in flux according to ultrasonic irradiation period was observed for 70 min. Parameters influenced to the recovery ratio corresponding the net flux on pure water and to the enhancement ratio applied after ultrasonic irradiation on the flux were analyzed. In same condition, the flux was improved in proportion to ultrasonic intensity while the improvement of flux was inversely proportional to ultrasonic frequency. The cleaning effect of membrane was delayed and reduced when operation pressure of membrane was high. The recovery ratio and enhancement ratio for $0.1{\mu}m$ MF membrane were 10% and 500%, respectively while those were maximized at $75{\sim}98%\;and\;40{\sim}50%$ for UF membrane for 10,000 and 100,000 MWCO, respectively. In conclusion, it was confirmed that ultrasonic cleaning using mechanical vibration is alternative to water or chemical cleaning for improving membrane flux.