• 제목/요약/키워드: Tubes

검색결과 3,108건 처리시간 0.031초

월성 3,4호기 증기발생기 전열관 검사 (Wolsong 3&4 Steam Generator Tube Inspection)

  • 장경식;권동기;최진혁;손태봉
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 추계학술대회논문집B
    • /
    • pp.859-866
    • /
    • 2001
  • During the Pre-service Inspection for Wolsong Unit 3&4 in 1997/1998 respectively, 17 Distorted Roll Transition indications(over expanded beyond tubesheet secondary face) were identified at the Unit 4 (S/G B, D). Six(6) tubes out of these tubes were plugged in 1998. However the first Periodic Inspection identified additional 110 indications in 1999 and 2000. The additionally identified 110 indication call, not reported at the Pre-service Inspection, are; 2 Not-Finally-Expanded-Tubes and 108 Distorted Roll Transition tubes. Design limit of each Steam Generator tube Plugging is 6.4%. Plugging was performed by the Steam Generator manufacturer under the warranty. When Distorted Roll Transition indications were first identified on the Unit 4 in 1998 the degree of Over-expansion was measured using an inner dial-gage to make the disposition of Nonconformance report. 2 Not-Finally-Expanded-Tubes were plugged and 10 tubes out of 108 Distorted Roll Transition Tubes were also plugged as a preventive measure.

  • PDF

A SIMPLIFIED METHOD TO PREDICT FRETTING-WEAR DAMAGE IN DOUBLE $90^{\circ}$ U-BEND TUBES

  • Choi, Seog-Nam;Yoon, Ki-Seok;Choi, Taek-Sang
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.616-621
    • /
    • 2003
  • Fluid-elastic instability is believed to be a cause of the large-amplitude vibration and resulting rapid wear of heat exchanger tubes when the flow velocity exceeds a critical value. For sub-critical flow velocities, the random turbulence excitation is the main mechanism to be considered in predicting the long-term wear of steam generator tubes. Since flow-induced interactions of the tubes with tube supports in the sub-critical flow velocity can cause a localized tube wear, tube movement in the clearance between the tube and tube support as well as the normal contact force on the tubes by fluid should be maintained as low as possible. A simplified method is used for predicting fretting-wear damage of the double $90^{\circ}$U-bend tubes. The approach employed is based on the straight single-span tube analytical model proposed by Connors, the linear structural dynamic theory of Appendix N-1300 to ASME Section III and the Archard's equation for adhesive wear. Results from the presented method show a similar trend compared with the field data. This method can be utilized to predict the fretting-wear of the double $90^{\circ}$U-bend tubes in steam generators.

  • PDF

가정용 보일러의 급탕시설 개선방안에 관한 연구 (A Study on the Improvement of the Water System in Domestic Boiler)

  • 한규일;박종운
    • 수산해양기술연구
    • /
    • 제34권2호
    • /
    • pp.200-211
    • /
    • 1998
  • Heat transfer performance improvement by fin and groovs is studied for condensation of R-11 on integral-fin tubes. Eight tubes with trapczodially shaped integral-fins having fin density from 748 to 1654fpm(fin per meter) and 10, 30 grooves are tested. A plain tube having the same diameter as the finned tubes is also used for comparison. R-11 condensates at saturation state of 32 $^{\circ}C$ on the outside tube surface coded by inside water flow. All of test data are taken at steady state. The heat transfer loop is used for testing singe long tubes and cooling is pumped from a storage tank through filters and folwmeters to the horizontal test section where it is heated by steam condensing on the outside of the tubes. The pressure drop across the test section is measured by menas pressure gauge and manometer. The results obtained in this study is as follows : 1. Based on inside diameter and nominal inside area, overall heat transfer coefficients of finned tube are enhanced up to 1.6 ~ 3.7 times that of a plain tube at a constant Reynolds number. 2. Friction factors are up to 1.6 ~ 2.1 times those of plain tubes. 3. The constant pumping power ratio for the low integral-fin tubes increase directly with the effective area to the nominal area ratio, and with the effective area diameter ratio. 4. A tube having a fin density of 1299fpm and 30 grooves has the best heat transfer performance.

  • PDF

유동층 연소로 내에서 수평전열관의 열전달 특성에 관한 연구 (Heat Transfer Characteristics of a Horizontal Fin Tube in a Fluidized Bed Combustor)

  • 맹민재;정준기;정태용
    • 대한기계학회논문집
    • /
    • 제19권9호
    • /
    • pp.2365-2372
    • /
    • 1995
  • The objective of this study is to get the basic data for the development of fluidized bed combustor. For this purpose, various rake angles(.theta.=20.deg., 25.deg., 30.deg., 35.deg.) of finned tubes and a smooth tube were installed horizontally in the fluidized bed combustor of 410*250mm. The effect of fluidized bed temperature, superficial velocity in bed, size of bed materials, rake angle of finned tubes on the heat transfer coefficient was experimentally investigated. The following results were obtained. (1) Under the fluidized bed temperature(750.deg. C-900.deg. C), and the gas velocity in bed(1.1-2.8m/sec), The highest heat transfer coefficient was measured with the rake angle of finned tubes was .theta.=25.deg. and .theta.=35.deg. for the average fluidized material particle size of 1.22mm and 1.54mm, respectively. Generally, the heat transfer coefficient of finned tubes is 1.4 to 2.4 times larger than that of smooth tubes. (2) The size of bed materials influences the rake angle of finned tubes which can have the highest heat transfer coefficient. As the temperature in bed gets higher, the effect of the rake angle of finned tubes on the heat transfer coefficient becomes greater.

응축용 특수 전열관의 열전달 특성에 관한 연구 (Experimental Study on Condensation Heat Transfer Characteristics of Special Heat Transfer Tubes)

  • 한규일;박종운;권영철;조동현
    • 설비공학논문집
    • /
    • 제13권9호
    • /
    • pp.827-835
    • /
    • 2001
  • In this study, condensation heat transfer characteristics were conducted with special heat transfer tubes of SH-C type. Experiments were carried out the saturated vapor temperature of 334K and the wall subcooling of 1.5-4.5K. The refrigerant was R-113 and the enhanced tubes used in the present study were SH-CDR, SH-CYR and SH-CHR. The experimental results showed that the condensation heat transfer coefficients of SH-C type tubes were about 23-66% higher than those of a low integral-fin tube. It was visualized that the condensed liquid on the outer surface of SH-C type tubes flowed continuously down unlike a low integral-fin tube and a plain tube, due to a 3-D extending fin on the outer surface of SH-C type tubes. As a result, the thermal resistance of the condensed liquid decreased and the heat transfer coefficient increased. Also, the enhancement ratio of SH-CDR tube was the highest, and it was about 9-11 times as compared to that of a plain tube.

  • PDF

축 압궤하중을 받는 Gr/E 복합재 튜브의 에너지 흡수특성 (The Absorbed Energy Characteristics of Gr/E Composite Tubes under Axial Collapse Load)

  • 양현수;김영남;최흥환
    • 대한안전경영과학회지
    • /
    • 제4권2호
    • /
    • pp.189-197
    • /
    • 2002
  • Composites have wide applications in aerospace vehicles and automobiles because of the inherent flexibility in their design lot improved material properties. Composite tubes in particular, are potential candidates for their use as energy absorbing elements in crashworthiness applications due to their high specific energy absorbing capacity and the stroke efficiency. Their failure mechanism however is highly complicated and rather difficult to analyze. This includes fracture in fibers, in the matrix and in the fiber-matrix interface in tension, compression and shear. The purpose of this study is to investigate the energy absorption characteristics of Gr/E(Graphite/Epoxy) tubes on static and impact tests. The collapse characteristics and energy absorption of a variety of tubes have been examined. Changes in the lay-up which increased the modulus increased the energy absorption of the tubes. Based on the test results, the following remarks can be made: Among CA15, CA00 and CA90 curves the CA90 tube exhibits the highest crush load throughout the whole crush process, and max load increases as interlaminar number increase. Among all the tubes type CC90 has the largest specific crushing stress of 52.60 kJ/kg which is much larger than other tubes.

세관 내 응축 열전달 특성에 관한 연구 (Study on the Condensation Heat Transfer Characteristics in Small Diameter Tubes)

  • 박기원;노건상;홍진우;오후규
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제28권1호
    • /
    • pp.29-38
    • /
    • 2004
  • The Condensation heat transfer coefficients of R-22 and R-l34a were measured in smooth horizontal copper tubes with inner diameters of 1.77. 3.36 and 5.35 mm. respectively. The experiments were conducted in a closed loop. which was driven by a magnetic gear pump. They were Performed for the following ranges of variables: mass flux (200 to $500\;kg/\textrm{m}^2{\cdot}s$) saturation temperature $30^{\circ}C$ and quality (0 to 1.0). The main results obtained are as follows Condensation heat transfer coefficients in the small diameter tubes (ID < 7 mm) were observed to be strongly affected by inner diameter change and to differ from those in the large diameter tubes. The heat transfer coefficients in the small diameter tubes were 20 ~ 40 % higher than those in the large diameter tubes as the inner diameter of the tube was reduced. Also. it was very difficult to apply some well-known previous predictions (Cavallini-Zecchin's. Haraguchi's and Dobson's correlation) to small diameter tubes. Based on an analogy between heat and mass transfer the new correlation is Proposed to predict the experimental data more accurately.

화섬용 지관의 강도향상에 관한 연구

  • 이명훈;김재능;김종경
    • 한국펄프종이공학회:학술대회논문집
    • /
    • 한국펄프종이공학회 2004년도 춘계학술발표논문집
    • /
    • pp.40-48
    • /
    • 2004
  • Paper tube industry for synthetic fiber packaging has approximately 200 billion won of market size in Korea, while any significant research has not done yet about physical characteristics of paper tubes. This study was conducted to find out a adequate structure of paper tubes by changing compositions of paperboards, size of tubes, and makers. Parallel compression strength was not only rely on compositions of paperboards, but also largely impacted by structural design of paper tubes.

  • PDF

원자로 노내계측기 안내관의 배열을 위한 간섭검증 (Interference Check for Reactor In-Core Instrumentation Guide Tube Routing)

  • 조덕상
    • 한국산업융합학회 논문집
    • /
    • 제3권3호
    • /
    • pp.201-207
    • /
    • 2000
  • In this study, methodologies for checking the interference between in-core instrumentation (ICI) guide tubes for routing of ICI guide tubes in the reactor coolant system of typical Pressurized Water Reactor under cold and normal operation (NOP) conditions are presented. The closest points of ICI guide tubes under cold condition are calculated by using minimize technique and are used as data for NOP analysis. Movements of ICI guide tubes under NOP condition are performed by the commercial computer code, SUPERPIPE.

  • PDF

Improving brightness of the LCOS system

  • Chen, Hun-Wei;Liu, Mei;Wu, Shih-Min;Mo, Chi-Neng
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2005년도 International Meeting on Information Displayvol.I
    • /
    • pp.737-739
    • /
    • 2005
  • To increase light efficiency, utilizing phosphors transfers ultraviolet ray to visible light and the fluorescent characteristic without change the electrical or optical design. Spreading phosphors on the surface of light bulb mirror can compensate the red and blue light to yield this correct white field after being stimulated by reflected ultraviolet ray.

  • PDF