• Title/Summary/Keyword: Tube current

Search Result 921, Processing Time 0.022 seconds

Automatic Exposure Control Performance Evaluation of Digital Radiographic Imaging System by Manufacturer Using Coins (동전을 이용한 제조사 별 디지털 방사선 영상 시스템의 자동노출제어 성능 평가)

  • Lim, Se-Hun;Seoung, Youl-Hun
    • Journal of radiological science and technology
    • /
    • v.45 no.1
    • /
    • pp.1-9
    • /
    • 2022
  • In this study, we proposed an image quality control for an automatic exposure control (AEC) of digital radiographic imaging system and tried to analyze the performance of the AEC by various manufacturer. The subjects of the experiment were analyzed for the AEC image quality evaluation using digital radiation generators from four manufacturer such as PHILIPS, GE Healthcare, SAMSUNG Healthcare, DK Medical Solution. We used as materials for the implementation of the image quality evaluation by coins (500 won, KOMSCO, Korea). This study evaluated the performance evaluation of the AEC as image quality and exposure dose (Milliampere-seconds; mAs). The image quality evaluation was tried visual assessment by two radiologic technologists and contrast to noise (CNR) by ImageJ. The exposure dose investigated mAs on digital radiation generators. The radiographic coin images acquired 360 images based on change in the control factors of the AEC, which were kVp, the consistency of field configuration and dominant zone, sensitivity and density. As a result, there was a significant difference in the AEC performance between manufacturer. The CNR by the AEC for each manufacturer showed a difference of up to about 1.9 times. The exposed tube current by the AEC for each manufacturer showed a difference of up to about 5.8 times. It is expected that our proposed evaluation method using coins could be applied as the AEC performance evaluation method in the future.

An Analysis of Beauty-Related Contents in Social Media in China, Thailand, and Indonesia (중국, 태국, 인도네시아의 소셜미디어 뷰티 콘텐츠 분석)

  • Her, Yusun;Chun, Jaehoon
    • Fashion & Textile Research Journal
    • /
    • v.23 no.3
    • /
    • pp.307-322
    • /
    • 2021
  • This study examined the influence of social media on the beauty industry and analyzed beauty-related content on social media in China, Thailand, and Indonesia. The existing literature was reviewed and four social media platforms that display the active sharing of beauty-related content in the three stated countries were selected. Five information sources were then chosen from each social media platform and 115 top posts from these sources analyzed. Beauty-related material was shared on discrete social media platforms in the three countries. Differences were found in the presentation types, themes, and message strategies of the content depending on the type of product and services provided by each social media platform. The content on Xiao Hongshu in China consisted of images showcasing product specifications along with a focus on honest and detailed empirical product review messages from its general users. From Taobao Zibo, Wang Hong conveyed powerful and influential information that communicated instantly with viewers and delivered entertaining and sensory messages. In Thailand earnest reviews of beauty products were offered, along with firsthand testimonials through traditional content uploaded on YouTube. In Indonesia, beauty influencers posted creative and sensational photographs of makeup products on image-centered Instagram. This study expands the current scholarship on social media platforms and extends the scope of the extant research on beauty-related content in Asian countries. The practical implications of this study include useful indications on how beauty brands can use social media to promote their products.

Reconstruction of Pharyngolaryngeal Defects with the Ileocolon Free Flap: A Comprehensive Review and How to Optimize Outcomes

  • Escandon, Joseph M.;Santamaria, Eric;Prieto, Peter A.;Duarte-Bateman, Daniela;Ciudad, Pedro;Pencek, Megan;Langstein, Howard N.;Chen, Hung-Chi;Manrique, Oscar J.
    • Archives of Plastic Surgery
    • /
    • v.49 no.3
    • /
    • pp.378-396
    • /
    • 2022
  • Several reconstructive methods have been reported to restore the continuity of the aerodigestive tract following resection of pharyngeal and hypopharyngeal cancers. However, high complication rates have been reported after voice prosthesis insertion. In this setting, the ileocolon free flap (ICFF) offers a tubularized flap for reconstruction of the hypopharynx while providing a natural phonation tube. Herein, we systematically reviewed the current evidence on the use of the ICFF for reconstruction of the aerodigestive tract. A systematic literature search was conducted across PubMed MEDLINE, Web of Science, ScienceDirect, Scopus, and Ovid MEDLINE(R). Data on the technical considerations and surgical and functional outcomes were extracted. Twenty-one studies were included. The mean age and follow-up were 54.65 years and 24.72 months, respectively. An isoperistaltic or antiperistaltic standard ICFF, patch flap, or chimeric seromuscular-ICFF can be used depending on the patients' needs. The seromuscular chimeric flap is useful to augment the closure of the distal anastomotic site. The maximum phonation time, frequency, and sound pressure level (dB) were higher with ileal segments of 7 to 15 cm. The incidence of postoperative leakage ranged from 0 to 13.3%, and the majority was occurring at the coloesophageal junction. The revision rate of the microanastomosis ranged from 0 to 16.6%. The ICFF provides a reliable and versatile alternative for reconstruction of middle-size defects of the aerodigestive tract. Its three-dimensional configuration and functional anatomy encourage early speech and deglutition without a prosthetic valve and minimal donor-site morbidity.

Recent Advances in 3D/4D Printed Electronics and Biomedical Applications (3D/4D 프린트된 전자기기 및 바이오메디컬 응용기술의 최근 발전)

  • Hyojun Lee;Daehoon Han
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.30 no.4
    • /
    • pp.1-7
    • /
    • 2023
  • The ability of 3D/4D printing technology to create arbitrary 3D structures provides a greater degree of freedom in the design of printed structures. This capability has influenced the field of electronics and biomedical applications by enabling the trends of device miniaturization, customization, and personalization. Here, the current state-of-the-art knowledge of 3D printed electronics and biomedical applications with the unique and unusual properties enabled by 3D/4D printing is reviewed. Specifically, the review encompasses emerging areas involving recyclable and degradable electronics, metamaterial-based pressure sensor, fully printed portable photodetector, biocompatible and high-strength teeth, bioinspired microneedle, and transformable tube array for 3D cell culture and histology.

Exploring Social Media Technologies Awareness and Use among Postgraduate Students of Library and Information Science in Nigeria: An Investigative Study

  • Stella Chinnaya Nduka;Sunday Olanrewaju Popoola
    • International Journal of Knowledge Content Development & Technology
    • /
    • v.14 no.3
    • /
    • pp.59-76
    • /
    • 2024
  • The prominent role accorded to social media in the academic community for research, teaching and learning revolves around its significance among users. Social media offers a platform for individuals to engage with and share perceptions relating to different disciplines. This current research was conducted to investigate the level of awareness and frequency of social media technology use among postgraduate students of Library and Information Science in Nigerian universities. The descriptive survey design was used for the study. Structured questionnaires were used to collect data from 919 library and information science (LIS) postgraduate students in the universities. In all, 742 copies out of the 919 distributed were returned and found usable, thereby making the return rate to be 81%. Data collected were analysed using mean and standard deviation. The study revealed that the LIS postgraduate students frequently use social media such as Wikipedia (x=3.94>3.50), Instagram (x=3.86>3.50), Facebook (x=3.85>3.50), Zoom ($\overline{x}$=3.78>3.50), LinkedIn (x=3.69>3.50), YouTube ($\overline{x}$=3.54>3.50), Twitter (x=3.52>3.50). The study established that students use social media tools for their personal, professional and research activities. The study also found that the level of awareness and use of social media by the students was high. The study recommended that the use of social media should be incorporated into the LIS curriculum including training sessions for the students on how to use the media effectively.

An exploratory study on fashion criticism in social media using text mining - Focusing on panel discussion of fashion show in YouTube - (텍스트 마이닝을 이용한 소셜 미디어의 패션 비평에 관한 탐색적 연구 - 유튜브의 패션쇼 Panel discussion을 중심으로 -)

  • Dawool Jung;Se Jin Kim
    • The Research Journal of the Costume Culture
    • /
    • v.32 no.2
    • /
    • pp.215-231
    • /
    • 2024
  • The changing media landscape has diversified how and what is discussed about fashion. This study aims to examine expert discussions about fashion shows on social media from the perspective of fashion criticism. To achieve this goal objectively, a text mining program, Leximancer, was used. In total, 58 videos were collected from the panel discussion section of Showstudio from S/S 21 to S/S 24, and the results of text mining on 24,080 collected texts after refinement are detailed here. First, the researchers examined the frequency of keywords by season. This revealed that in 2021-2022, digital transformation, diversity, and fashion films are now commonly used to promote fashion collections, often replacing traditional catwalk shows. From 2023, sustainability and virtuality appeared more frequently, and fashion brands focused on storytelling to communicate seasonal concepts. In S/S 2024, the rise of luxury brand keywords and an increased focus on consumption has been evident. This suggests that it is influenced by social and cultural phenomena. Second, the overall keywords were analyzed and categorized into five concepts: formal descriptions and explanations of the collection's outfits, sociocultural evaluations of fashion shows and designers, assessments of the commerciality and sustainability of the current fashion industry, interpretations of fashion presentations, and discussions of the role of fashion shows in the future. The significance of this study lies in its identification of the specificity of contemporary fashion criticism and its objective approach to critical research.

Mechanical Performance Study of Piggy Back Clamp for Submarine Cables (해저케이블용 피기백 클램프의 기계적 성능 연구)

  • Yun Jae Kim;Kyeong Soo Ahn;Jin-wook Choe;Jinseok Lim;Sung Woong Choi
    • Composites Research
    • /
    • v.37 no.2
    • /
    • pp.108-114
    • /
    • 2024
  • Due to the continuously increasing global demand for electricity, the demand for high-voltage submarine cables is also increasing. One of the issues that need to be addressed for submarine cables is the high production cost and expensive laying costs. Submarine cables exposed to the marine environment encounter external forces such as wave and current, leading to issues such as cable damage due to external factors or high maintenance costs in the event of an accident. Therefore, we are preparing for the uncertainty of the submarine environment through many protective materials and protective equipment. In this study, we examined the bending performance of piggyback clamps (PBC) and strap, which are representative protective equipment, in response to the submarine environment through analytical methods. To examine the structural performance of PBC, the bending performance were assessed under the maximum bending moment criterion of 15 kN·m for the flexible protection tube. As a result, it was confirmed that the structural performance regarding the bending moment of both PBC and straps was ensured.

Dosimetric Evaluation of a Small Intraoral X-ray Tube for Dental Imaging (치과용 초소형 X-선 튜브의 선량평가)

  • Ji, Yunseo;Kim, YeonWoo;Lee, Rena
    • Progress in Medical Physics
    • /
    • v.26 no.3
    • /
    • pp.160-167
    • /
    • 2015
  • Radiation exposure from medical diagnostic imaging procedures to patients is one of the most significant interests in diagnostic x-ray system. A miniature x-ray intraoral tube was developed for the first time in the world which can be inserted into the mouth for imaging. Dose evaluation should be carried out in order to utilize such an imaging device for clinical use. In this study, dose evaluation of the new x-ray unit was performed by 1) using a custom made in vivo Pig phantom, 2) determining exposure condition for the clinical use, and 3) measuring patient dose of the new system. On the basis of DRLs (Diagnostic Reference Level) recommended by KDFA (Korea Food & Drug Administration), the ESD (Entrance Skin Dose) and DAP (Dose Area Product) measurements for the new x-ray imaging device were designed and measured. The maximum voltage and current of the x-ray tubes used in this study were 55 kVp, and 300 mA. The active area of the detector was $72{\times}72mm$ with pixel size of $48{\mu}m$. To obtain the operating condition of the new system, pig jaw phantom images showing major tooth-associated tissues, such as clown, pulp cavity were acquired at 1 frame/sec. Changing the beam currents 20 to $80{\mu}A$, x-ray images of 50 frames were obtained for one beam current with optimum x-ray exposure setting. Pig jaw phantom images were acquired from two commercial x-ray imaging units and compared to the new x-ray device: CS 2100, Carestream Dental LLC and EXARO, HIOSSEN, Inc. Their exposure conditions were 60 kV, 7 mA, and 60 kV, 2 mA, respectively. Comparing the new x-ray device and conventional x-ray imaging units, images of the new x-ray device around teeth and their neighboring tissues turn out to be better in spite of its small x-ray field size. ESD of the new x-ray device was measured 1.369 mGy on the beam condition for the best image quality, 0.051 mAs, which is much less than DRLs recommended by IAEA (International Atomic Energy Agency) and KDFA, both. Its dose distribution in the x-ray field size was observed to be uniform with standard deviation of 5~10 %. DAP of the new x-ray device was $82.4mGy*cm^2$ less than DRL established by KDFA even though its x-ray field size was small. This study shows that the new x-ray imaging device offers better in image quality and lower radiation dose compared to the conventional intraoral units. In additions, methods and know-how for studies in x-ray features could be accumulated from this work.

Research of Protocols for Optimization of Exposure Dose in Abdominopelvic CT - (복부-골반 CT검사 시 피폭선량 최적화에 관한 프로토콜 연구)

  • Hong, Dong-Hee
    • Journal of radiological science and technology
    • /
    • v.40 no.2
    • /
    • pp.245-251
    • /
    • 2017
  • This study measured the exposure dose during abdominal-pelvic CT exam which occupies 70% of CT exam and tried to propose a protocol for optimized exposure dose in abdomen and pelvis without affecting the imagery interpretation. The study scanned abdomen-pelvis using the current clinical scan method, the 120 kVp, auto exposure control(AEC), as 1 phase. As for the newly proposed 2 phase scan method, the study divided into 1 phase abdomen exam and 2 phase pelvis exam and each conducted tube voltage 120 kVp, AEC for abdomen exam, and fixed tube current method in 120 kVp, 100, 150, 200, 250, 300, 350, 400 mA for pelvis exam. The exposure dose value was compared using $CTDI_{VOL}$, DLP value measured during scan, and average value of CT attenuation coefficient, noise, SNR from each scan image were obtained to evaluate the image. As for the result, scanning of 2 phase showed significant difference compared to 1 phase. In $CTDI_{VOL}$ value, the 2 phase showed 26% decrease in abdomen, 1.8~59.5% decrease in pelvis for 100~250 mA, 12.7%~30% increase in pelvis for 300~400 mA. Also, DLP value showed 53% decrease in abdomen and 41~81% decrease in pelvis when scanned by 2 phase compared to 1 phase, but it was not statistically significant. As for the SNR, when scanning 2 phase close to heart, scanning 1 phase close to pelvis, scanning and scanning 1 phase at upper and lower abdomen, it was higher when scanning 2 phase for 200~250 mA. Also, the CT number and noise was overall similar, but the noise was high close to pelvis. However, when scanning 2 phase for 250 mA close to pelvis, the noise value came out similar to 1 phase, and did not show statistically significant difference. It seems when separating pelvis to scan in 250 mA rather than 400 mA in 1 phase as before, it is expected to have reduced effect of exposure dose without difference in the quality of image. Thus, for patients who often get abdominal-pelvic CT exam, fertile women or children, this study proposes 2 phase exam for smaller exposure dose with same image quality.

A Study on the Optimum Design for Preventing Propelling Charge to Military Ammunition Vehicle (탄약운반장갑차의 장약 파손 방지를 위한 최적설계에 관한 연구)

  • Noh, Sang Wan;Kim, Sung Hoon;Park, Young Min;Kim, Byung Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.11
    • /
    • pp.494-500
    • /
    • 2019
  • The purpose of this study was to determine a method to prevent damage during the transfer of loading through optimal design of loading transfer software for an ammunition-carrying armored vehicle. Typically, an ammunition carrier armored car is equipped with an automated charge transfer system. The load is intermittently damaged during the loading of the cargo, and this needs to be improved. The following improvements and verification tests were carried out. As impact speed increased, the loading speed was reduced 60%, and a special fixture utilizing a force gauge was developed and tested. If the maximum current of 11A for the servo controller is output when the load of the conveyor is generated by interference inside the loading tube, there is a possibility of charge breakage. If the maximum current is low, the load cannot be loaded. In the loading test for the ammunition carrier armored car with the actual charge, the improved design was found to be valid, as the load was not damaged and occurred nominally.