• 제목/요약/키워드: Tube current

검색결과 926건 처리시간 0.037초

설비공학 분야의 최근 연구 동향 : 2010년 학회지 논문에 대한 종합적 고찰 (Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2010)

  • 한화택;이대영;김서영;최종민;김수민;권영철;백용규
    • 설비공학논문집
    • /
    • 제23권6호
    • /
    • pp.449-469
    • /
    • 2011
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigerating Engineering during 2010. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) Research trends of thermal and fluid engineering have been surveyed as groups of general thermal and fluid flow, fluid machinery, and new and renewable energy. Various topics were presented in the field of general thermal and fluid flow. Research issues mainly focused on the thermal reliability of axial fan and compressor in the field of fluid machinery. Studies on the design of ground source heat pump systems and solar chemical reactors were executed in the field of new and renewable energy. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics and industrial heat exchangers. Researches on heat transfer characteristics included heat transfer in thermoelectric cooling/power generation systems, combined heat and power systems, carbon nano fluid with PVP, channel filled with metal foam and smoke ventilation in a rescue station of a railroad tunnel. Also the studies on flow boiling of R123/oil mixture in a plain tube bundle and R410A charge amount in an air cooled mini-channel condenser were reported. In the area of industrial heat exchangers, researches on plate heat exchanger, shell and tube heat exchanger, enthalpy exchanger, micro channel PCHE were performed. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics and industrial heat exchangers. Researches on heat transfer characteristics included heat transfer in thermoelectric cooling/power generation systems, combined heat and power systems, carbon nano fluid with PVP, channel filled with metal foam and smoke ventilation in a rescue station of a railroad tunnel. Also the studies on flow boiling of R123/oil mixture in a plain tube bundle and R410A charge amount in an air cooled mini-channel condenser were reported. In the area of industrial heat exchangers, researches on plate heat exchanger, shell and tube heat exchanger, enthalpy exchanger, micro channel PCHE were performed. (3) Refrigeration systems with alternative refrigerants such as hydrocarbons, mixed refrigerants, and CO2 were studied. Performance improvement of refrigeration systems are tried applying various ideas of refrigerant subcooling, dual evaporator with hot gas bypass control and feedforward control. The hybrid solar systems combining the solar collection devices with absorption chillers or compression heat pumps are simulated and studied experimentally as well to improve the understanding and the feasibility for actual applications. (4) Research trend in the field of mechanical building facilities has been found to be mainly focused on field applications rather than performance improvements. Various studies on heating and cooling systems, HVAC facilities, indoor air environments and energy resources were carried to improve the maintenance and management of building service equipments. In the field of heating and cooling systems, papers on a transformer cooling system, a combined heat and power, a slab thermal storage and a heat pump were reported. In the field of HVAC facilities, papers on a cooling load, an ondol and a drying were presented. Also, studies on HVAC systems using unutilized indoor air environments and energy resources such as air curtains, bioviolence, cleanrooms, ventilation, district heating, landfill gas were studied. (5) In the field of architectural environment and energy, studies of various purposes were conducted such as indoor environment, building energy, renewable energy and green building. In particular, renewable energy and building energy-related researches have mainly been studied reflecting the global interest. In addition, many researches which related the domestic green building certification of school building were performed to improve the indoor environment of school.

설비공학 분야의 최근 연구 동향 : 2013년 학회지 논문에 대한 종합적 고찰 (Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2013)

  • 이대영;김사량;김현정;김동선;박준석;임병찬
    • 설비공학논문집
    • /
    • 제26권12호
    • /
    • pp.605-619
    • /
    • 2014
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2013. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering have been reviewed as groups of fluid machinery, pipes and relative parts including orifices, dampers and ducts, fuel cells and power plants, cooling and air-conditioning, heat and mass transfer, two phase flow, and the flow around buildings and structures. Research issues dealing with home appliances, flows around buildings, nuclear power plant, and manufacturing processes are newly added in thermal and fluid engineering research area. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the results for general analytical model for desiccant wheels, the effects of water absorption on the thermal conductivity of insulation materials, thermal properties of Octadecane/xGnP shape-stabilized phase change materials and $CO_2$ and $CO_2$-Hydrate mixture, effect of ground source heat pump system, the heat flux meter location for the performance test of a refrigerator vacuum insulation panel, a parallel flow evaporator for a heat pump dryer, the condensation risk assessment of vacuum multi-layer glass and triple glass, optimization of a forced convection type PCM refrigeration module, surface temperature sensor using fluorescent nanoporous thin film. In the area of pool boiling and condensing heat transfer, researches on ammonia inside horizontal smooth small tube, R1234yf on various enhanced surfaces, HFC32/HFC152a on a plain surface, spray cooling up to critical heat flux on a low-fin enhanced surface were actively carried out. In the area of industrial heat exchangers, researches on a fin tube type adsorber, the mass-transfer kinetics of a fin-tube-type adsorption bed, fin-and-tube heat exchangers having sine wave fins and oval tubes, louvered fin heat exchanger were performed. (3) In the field of refrigeration, studies are categorized into three groups namely refrigeration cycle, refrigerant and modeling and control. In the category of refrigeration cycle, studies were focused on the enhancement or optimization of experimental or commercial systems including a R410a VRF(Various Refrigerant Flow) heat pump, a R134a 2-stage screw heat pump and a R134a double-heat source automotive air-conditioner system. In the category of refrigerant, studies were carried out for the application of alternative refrigerants or refrigeration technologies including $CO_2$ water heaters, a R1234yf automotive air-conditioner, a R436b water cooler and a thermoelectric refrigerator. In the category of modeling and control, theoretical and experimental studies were carried out to predict the performance of various thermal and control systems including the long-term energy analysis of a geo-thermal heat pump system coupled to cast-in-place energy piles, the dynamic simulation of a water heater-coupled hybrid heat pump and the numerical simulation of an integral optimum regulating controller for a system heat pump. (4) In building mechanical system research fields, twenty one studies were conducted to achieve effective design of the mechanical systems, and also to maximize the energy efficiency of buildings. The topics of the studies included heating and cooling, HVAC system, ventilation, and renewable energies in the buildings. Proposed designs, performance tests using numerical methods and experiments provide useful information and key data which can improve the energy efficiency of the buildings. (5) The field of architectural environment is mostly focused on indoor environment and building energy. The main researches of indoor environment are related to infiltration, ventilation, leak flow and airtightness performance in residential building. The subjects of building energy are worked on energy saving, operation method and optimum operation of building energy systems. The remained studies are related to the special facility such as cleanroom, internet data center and biosafety laboratory. water supply and drain system, defining standard input variables of BIM (Building Information Modeling) for facility management system, estimating capability and providing operation guidelines of subway station as shelter for refuge and evaluation of pollutant emissions from furniture-like products.

관전압과 관전류량 변화에 대한 가상 그리드 소프트웨어(VGS) 화질평가 (Evaluation of Virtual Grid Software (VGS) Image Quality for Variation of kVp and mAs )

  • 공창기
    • 한국방사선학회논문지
    • /
    • 제17권5호
    • /
    • pp.725-733
    • /
    • 2023
  • 본 연구의 목적은 가상 그리드 소프트웨어(VGS)의 유효성을 평가하기 방법으로 이동형 그리드를 사용하지 않은 상태에서 VGS를 사용할 때와 사용하지 않을 때(Without-VGS)로 구분하여 에너지와 피사체 두께에 변화를 주고 흉부 팬텀과 대퇴부 팬텀을 이용하여 영상을 획득하고, SNR과 CNR을 분석하여 VGS의 유효성을 알아보고자 하였다. 흉부 팬텀과 대퇴부 팬텀에서 관전류는 2.5 mAs로 고정하고, 관전압을 60 ~ 100 kVp에서 10kVp 씩 변화하여 X선 조사한 후 SNR과 CNR을 측정한 결과 흉부 팬텀에서 SNR은 Without-VGS 보다 VGS에서 약 1.09 ~ 8.86% 높게 나타났고, CNR은 Without-VGS 보다 VGS에서 4.18 ~ 14.56% 높게 나타났다. 그리고 대퇴부 팬텀에서는 SNR이 Without-VGS 보다 VGS에서 약 9.78 ~ 18.05% 높게 나타났고, CNR은 Without-VGS 보다 VGS에서 21.07 ~ 44.44% 높게 나타났다. 흉부 팬텀과 대퇴부 팬텀에서 관전압을 70 kVp로 고정하고, 관전류량은 2.5 ~ 16 mAs에서 각각 변화하여 X선 조사한 후 SNR과 CNR을 측정한 결과 흉부 팬텀에서 SNR은 Without-VGS 보다 VGS에서 약 1.49 ~ 11.11% 높게 나타났고, CNR은 Without-VGS 보다 VGS에서 4.76 ~ 13.40% 높게 나타났다. 그리고 대퇴부 팬텀에서는 SNR은 Without-VGS 보다 VGS에서 약 2.22 ~ 17.38% 높게 나타났고, CNR은 Without-VGS 보다 VGS에서 13.85 ~ 40.46% 높게 나타났다. 결론적으로 Without-VGS 보다 VGS를 사용할 때 SNR과 CNR이 높게 나타났다. 그러므로 이동형 X선 촬영장치로 검사를 해야 하는 경우 이동형 그리드를 사용하기 어려운 환경에서 VGS를 사용함으로써 좋은 영상의 화질을 얻을 수 있어 검사에 유용하게 사용될 것으로 판단되고, 이동형 X선 장치의 활용성을 증대시킬 수 있을 것으로 판단된다.

경북 지역 의원급의 X선 발생장치 정도관리 실태 (Medical Clinics' quality Management of X-ray Units in Gyeongbuk Area)

  • 박정규
    • 한국콘텐츠학회논문지
    • /
    • 제10권9호
    • /
    • pp.267-275
    • /
    • 2010
  • X선 발생장치의 정도관리는 의료기관의 설립형태에 따라 가장 큰 차이가 있으며, 장치의 보유율은 1차 의료기관에서 가장 많이 보유한 반면 정도관리에 대한 인식과 관리는 소홀하다 할 수 있다. 본 연구에서는 2010년 1월 4일부터 2010년 9월 3일까지 경북 지역을 4개의 권역으로 나누고, 각 시별로 4곳을 임으로 선정하였다. 전체 16곳에 있는 의원급 의료기관 중 10년 이상 된 X선 발생장치를 보유한 8곳과 10년 이하의 X선 발생장치를 보유한 8곳를 그 대상으로 하였으며, 정도관리의 필수 항목 5가지를 시험하였다. 접지 설비 확인시험에서는 10년 이상 된 X선 장치를 보유한 한 곳이 별도의 접지선을 구비하지 않았으며(6.25%), 외장 누설전류시험에서는 모두 적합 하였다. 조사선량 재현성 시험에서는 10년 이상 된 X선 발생장치를 보유한 4곳(25%)과 10년 이하의 X선 발생장치를 보유한 1(6.25%)곳이 부적합 하였다. 관전압의 정확도 시험에서는 10년 이상 된 X선 발생장치를 보유한 5곳(31.25%)과 10년 이하의 X선 장치를 보유한 2곳(12.5%)이 부적합 하였다. 관전류와 관전류량 시험에서는 10년 이상 된 X선 장치를 보유한 3곳(18.75%)과 10년 이하의 X선 장치를 보유한 1곳(6.25%)이 부적합 하였다. 본 연구 결과 10년 이하의 X선 발생장치를 보유한 의원급 의료기관 보다 10년 이상 된 의원급 의료기관의 X선 발생장치의 정도 관리 실태는 심각한 수준 이였다. 검사 결과를 바탕으로 행정적, 기술적인 조치들이 신속하게 이루어져야 할 것이다. 또한 의원급의 사업주나 장치 담당자들의 의식 전환이 필요 하며 그러기 위해서는 오래된 장비이거나 자주 사용하지 않는 장비일수록 정기검사주기를 1~2년 단위로 개정하여야 하고, 정기적인 정도 관리 교육 프로그램을 실시하여야 할 것으로 사료된다.

관상동맥 조영술(Coronary Angiography)의 씨네(cine) 촬영조건 변화에 따른 입사표면선량(ESD)과 흡수선량(DAP) 및 영상의 SNR·CNR 유용성 분석: 관전류 변화를 중점으로 (Analysis of the ESD and DAP According to the Change of the Cine Imaging Condition of Coronary Angiography and Usefulness of SNR and CNR of the Images: Focusing on the Change of Tube Current)

  • 서영현;송종남
    • 한국방사선학회논문지
    • /
    • 제13권3호
    • /
    • pp.371-379
    • /
    • 2019
  • 관상동맥 조영술(CAG)의 씨네(Cine) 촬영에서 엑스선 촬영 조건의 변화가 입사 표면 선량(ESD)과 흡수선량(DAP)에 미치는 관계를 알아보고자 하였고 image J 프로그램을 통해 촬영된 혈관 조영 영상의 SNR과 CNR을 측정 분석하여 조건 변화가 선량관계 및 영상의 질에 미치는 유용성을 분석하고자 하였다. 2017년 11월부터 2018년 3월까지 본원에서 CAG를 시행한 33명(남24, 여9)의 데이터를 대상으로 하였고, 연령대는 37-76세(평균 $59{\pm}10$세), 몸무게53-104kg (평균 $72{\pm}10kg$), 키150-185cm (평균 $166.82{\pm}9.5kg$), BMI 18.3-33.2(평균 $25.8{\pm}3.2$)이었다. 촬영조건 및 데이터 획득은 관전류(mA)를 높게 한 A그룹(397.2mA)과 mA를 낮게 한 B그룹(370.7mA)의 ESD와 DAP를 후향적으로 획득하여 비교 분석 하였고 Image J를 통한 SNR과 CNR 측정 분석은 획득한 데이터를 공식에 대입하여 결과 값을 도출하였다. 통계프로그램은 SPSS (PASW)를 사용하여 촬영조건 변화에 따른 ESD와 DAP 및 SNR CNR의 상관관계 등을 분석하였다. 촬영조건의 mA에 변화를 주어 촬영한 A그룹과 B그룹의 ESD($A:483.5{\pm}60.1$, $B: 464.4{\pm}39.9$)와 DAP($A:84.3{\pm}10.7$, $B:81.5{\pm}7$)간의 관계는 통계적으로 유의하지 않았다(p>0,05). Image J를 통한 SNR과 CNR의 관계에선 B그룹의 좌심장동맥(LCA)을 촬영해 얻은 영상의 SNR($5.451{\pm}0.529$), CNR($0.411{\pm}0.0432$)이 A그룹 좌심장동맥(LCA)의 SNR($4.976{\pm}0.433$), CNR($0.459{\pm}0.0431$)보다 SNR $0.475{\pm}0.096$, CNR $-0.048{\pm}0.0$로 차이가 있었으나 통계적으로 유의하지는 않았다(p<0.05). 우심장동맥(RCA)을 촬영해 획득한 SNR과 CNR에선 A그룹의 SNR($4.731{\pm}0.773$)과 CNR($0.354{\pm}0.083$)이 B그룹의 SNR($3.24{\pm}0.368$), CNR($0.166{\pm}0.033$)보다 SNR $1.491{\pm}0.405$, CNR $0.188{\pm}0.005$로 증가된 수치를 나타냈으며 그 중 CNR이 통계적으로 유의했다(p<0.05). 상관관계 분석 결과에서는 SNR (LCA) & CNR (LCA), SNR (RCA) & CNR (RCA), ESD & DAP, ESD & sec, DAP & CNR (RCA), DAP & sec간에 통계적으로 유의한 차이를 나타냈다(p<0.05). SNR과 CNR이 높을수록 선명하고 좋은 화질을 나타냄을 의미하는데 화질평가 및 선량변화 유용성에 관한 분석 연구를 진행한 결과 mA를 증가시켜 촬영 한 CAG의 RCA영상에서 SNR과 CNR이 증가된 수치를 보였다. 특히, CNR이 통계적으로 유의한 차이를 나타낸 것을 보았을 때 RCA촬영 시 mA를 향상시켜 촬영 할 경우 영상의 질 중 대조도가 한층 더 향상 될 수 있을 것으로 사료된다.

수직형 순환식 수은 모세관 다발체 전극 전해계의 개발과 그 특성 연구 (A Study on the Development of Electrolysis System with Vertically Circulating Mercury Capillary Bundle Electrode and its Characteristics)

  • 김광욱;이일희;신영준;유재형;박현수
    • 공업화학
    • /
    • 제7권2호
    • /
    • pp.228-236
    • /
    • 1996
  • 본 연구에서는 고밀집 섬유다발체 내에 수은과 금속이온을 함유한 수용액을 동시에 주입시켜 최소 공간에서 최대한의 수은전극 면적을 갖는 수직형 순환식 수은 모세관 다발체 전극 전해반응 장치가 개발되었다. 이 장치의 특성과 안정성을 평가하기 위해 수은과 수용액의 유량 변화에 따른 철(III)과 우라늄(VI)이온의 환원 voltammogram이 측정되었다. 수용액의 유속은 장치 내 전해반응에 큰 영향을 미쳤으며, 잘 발달된 한계전류를 얻기 위해서는 정밀한 유속조절이 필요하였다. 측정된 voltammogram의 한계전류는 수용액 유속에 선형적으로 비례하였으며, 한계전류를 보이는 전위에서 연속적으로 우라늄(VI)과 철(III) 이온을 100% 환원시킬 수 있었다. 고밀집 섬유집합체 내에서 수은이 모세관 연속체를 유지하는데 필요로 하는 수은유속 이상에서는 수은유속의 변화는 장치 내의 전해반응에 큰 영향을 미치지 않았다. 본 연구에서 개발된 수직형 순환식 수은 모세관 다발체 전극 전해계는 정확히 제어되는 수용액 유량조건에서 수용액 내의 금속이온의 산화수 상태 및 농도의 연속적인 분석 및 전해반응 기구 해석에 효과적으로 사용될 수 있음을 알 수 있었다.

  • PDF

적설하중 증가에 대비한 비닐하우스 골조 성능의 개선 연구 (A Study on the Improvement of Greenhouse Frame to Bear the Heavy Snow)

  • 정현진;양상현;이태희
    • 한국산학기술학회논문지
    • /
    • 제16권3호
    • /
    • pp.2242-2248
    • /
    • 2015
  • 본 연구는 폭설로 인하여 비닐하우스가 붕괴되는 사고가 잇따르는 것에 대비하여 효율적인 비닐하우스 골조의 개선방안을 찾고자 진행되었다. 2013년 겨울, 비닐하우스 피해가 가장 컸던 곳은 경북과 강원도로, 이 지역에서 가장 많이 사용되고 있는 비닐하우스 유형(07-단동 3형, 07-단동 18형)에 대하여 최대 적설량 대비 30%까지 하중을 증가시켜 MIDAS GEN 프로그램을 사용하여 구조적 안전성을 검토하였다. 해석의 결과, 경주의 비닐하우스는 적설하중의 중가에 대해 안전하였으나 속초의 경우는 위험요인이 발생하였으며, 강릉의 비닐하우스는 기존 적설하중에서도 붕괴 가능성이 있는 것으로 나타났다. 폭설에 대비, 비닐하우스 구조단면의 성능을 개선하기 위하여 서까래를 이루는 원형파이프 단면의 성능을 개선하는 동시에 서까래의 간격을 증가시켜 적정 비닐하우스 구조를 검토한 결과, 서까래의 관경과 간격을 증가시키는 방안이 서까래의 두께와 간격을 증가시키는 방안보다 구조적으로 효율적인 것으로 해석되었다. 향후 폭설에 대비하여 비닐하우스의 서까래 관경을 증가시킨 적정 규격의 제안이 필요할 것으로 판단된다.

PCITS에 의해 소손된 강이음쇠형 CSST의 특성 해석에 관한 연구 (A Study on the Properties Analysis of an Iron Fittings Type CSST Damaged by the PCITS)

  • 이장우;최충석
    • 한국화재소방학회논문지
    • /
    • 제30권4호
    • /
    • pp.121-127
    • /
    • 2016
  • 본 논문에서는 대전류공급장치(PCITS)에 의해 소손된 강이음쇠형(iron fittings type) 금속플렉시블호스(CSST)의 구조 및 전기적 특성을 해석하였다. CSST는 보호 피막, 튜브, 너트, 클램프 링, 플레어 캡, 소켓, 볼 밸브 등으로 구성되어 있다. CSST의 내전압 평가는 전기 충전부와 비충전부 사이에 교류 전압 220 V를 1분간 인가하여 견뎌야 한다. 직류 500 V에 의한 절연 성능의 평가는 온도 상승 시험 전에 $1M{\Omega}$ 이상, 시험이 끝난 후에는 $0.3M{\Omega}$ 이상을 요구한다. 정상 제품의 평균 저항은 $11.5m{\Omega}$이었으나 PCITS로 130 A를 흘려 소손된 제품의 평균 저항 $11.50m{\Omega}$이었다. 또한 130 A가 약 10 s 흘렀을 때 튜브의 보호 피막이 일부 용융되었고, 검정색의 연기가 발생하였다. 60 s 경과되면 튜브의 대부분이 적색으로 발열되며, 전류가 120 s 흘렀을 때는 적열 범위가 넓어졌다. 95%의 신뢰 구간(CI)의 검증에서 P 값은 0.019로 정규 분포를 갖지 못하였으나 Anderson-Darling (AD) 통계량은 0.896, 표준 편차는 0.5573 등으로 양호한 특성을 나타냈다.

원전 증기발생기 전열관 와전류검사 보빈탐촉자의 특성 시험 (Characteristics Testing of the ECT Bobbin Probe for Steam Generator Tube Inspection of Nuclear Power Plant)

  • 남민우;이희종;조찬희;유현주
    • 비파괴검사학회지
    • /
    • 제30권4호
    • /
    • pp.386-395
    • /
    • 2010
  • 국내 원자력 증기발생기 관리프로그램 통합지침서는 와전류검사 장비 및 기법에 대한 자격인정 절차를 규정하고 있다. 이러한 자격인정 절차에는 두 가지 방법이 있다. 첫 번째는 열교환기에서 인출된 튜브 혹은 인공결함에 의한 결함 발생기구 및 기법을 사용하여 장비 혹은 탐촉자를 인정한다. 두 번째는 이미 인정된 장비 혹은 탐촉자 특성과 동등함을 입증할 경우, 즉 검사기술사양서에 기술된 필수변수 범위가 만족된다면 인정절차 없이 이미 인정된 장비 혹은 탐촉자를 대체하여 사용할 수 있다. 본 논문은 국산화 개발된 보빈탐촉자와 이미 해외에서 인정된 보빈탐촉자의 특성을 비교 수행한 결과를 수록하였다. 탐촉자의 전기적 특성평가를 위해 임피던스 및 공진주파수를 측정하였으며, 자기장 특성평가를 위해 유효주사 자기장 폭 측정, 충전율 계수 측정, 깊이계수 측정, 축방향 길이계수 측정, 횡방향 폭계수 측정, 위상각 대 깊이곡선 측정 및 직류포화세기를 측정하였다. 본 특성시험 결과 두 종류의 탐촉자 특성이 거의 동등한 것으로 평가됨에 따라 향후 현장 적용을 위한 기반을 구축한 것으로 판단된다.

공극(기극(氣隙)) 변화에 따른 방사선촬영 선량평가 (An Assessment of the Radiation Dose from Radiography with the Change in Air Gap)

  • 안병주
    • 한국방사선학회논문지
    • /
    • 제10권6호
    • /
    • pp.381-385
    • /
    • 2016
  • 본 연구에서는 공극 기법의 고관전압 촬영에서 격자를 사용한 것과 같은 화질을 유지하면서 선량을 줄이는 방안을 제안하고자 하였다. 실험은 초점과 수용체와의 거리 180 cm에서 공극을 10 cm, 15 cm, 20 cm, 25 cm, 30 cm으로 하였으며 각각의 공극 거리에서 관전류를 15 mAs로 고정하고 관전압은 80 KvP, 85 kVp, 90 kVp, 95 kVp, 100 kVp로 하여 촬영을 하였다. 전통적인 방법인 격자를 사용하였을 때 촬영은 초점과 수용체와의 거리 180 cm에서 15 mAs, 107 kVp로 하였다. 실험결과 격자를 사용하여 촬영하였을 때 표면선량은 0.130 R로 나타났고 공극을 20 cm로 하였을 때의 표면선량은 0.124 R로 나타났으며 두 영상 간의 PSNR은 10.65 [dB]로 나타났다. 결론적으로 표면선량이 적으면서 산란선을 제거하여 격자를 사용하였을 때와 유사한 화질을 유지할 수 있는 공극의 거리는 20 cm로 나타났다. 연구의 결과는 공극을 이용한 방사선촬영에서 표면선량을 제거할 수 있는 지표로 사용할 수 있을 것으로 사료된다. 결론적으로 표면선량이 적으면서 산란선을 제거하여 격자를 사용하였을 때와 유사한 화질을 유지할 수 있는 공극의 거리는 20 cm로 나타났다. 연구의 결과는 공극을 이용한 방사선촬영에서 표면선량을 절감할 수 있는 지표로 사용할 수 있을 것으로 사료된다.