• 제목/요약/키워드: Tube current

검색결과 921건 처리시간 0.025초

DETECTION OF ODSCC IN SG TUBES DEPENDING ON THE SIZE OF THE CRACK AND ON THE PRESENCE OF SLUDGE DEPOSITS

  • Chung, Hansub;Kim, Hong-Deok;Kang, Yong-Seok;Lee, Jae-Gon;Nam, Minwoo
    • Nuclear Engineering and Technology
    • /
    • 제46권6호
    • /
    • pp.869-874
    • /
    • 2014
  • It was discovered in a Korean PWR that an extensive number of very short and shallow cracks in the SG tubes were undetectable by eddy current in-service-inspection because of the masking effect of sludge deposits. Axial stress corrosion cracks at the outside diameter of the steam generator tubes near the line contacts with the tube support plates are the major concern among the six identical Korean nuclear power plants having CE-type steam generators with Alloy 600 high temperature mill annealed tubes, HU3&4 and HB3~6. The tubes in HB3&4 have a less susceptible microstructure so that the onset of ODSCC was substantially delayed compared to HU3&4 whose tubes are most susceptible to ODSCC among the six units. The numbers of cracks detected by the eddy current inspection jumped drastically after the steam generators of HB4 were chemically cleaned. The purpose of the chemical cleaning was to mitigate stress corrosion cracking by removing the heavy sludge deposit, since a corrosive environment is formed in the occluded region under the sludge deposit. SGCC also enhances the detection capability of the eddy current inspection at the same time. Measurement of the size of each crack using the motorized rotating pancake coil probe indicated that the cracks in HB4 were shorter and substantially shallower than the cracks in HU3&4. It is believed that the cracks were shorter and shallower because the microstructure of the tubes in HB4 is less susceptible to ODSCC. It was readily understood from the size distribution of the cracks and the quantitative information available on the probability of detection that most cracks in HB4 had been undetected until the steam generators were chemically cleaned.

Experimental studies and numerical analysis of the shear behavior of fin plates to tubular columns at ambient and elevated temperatures

  • Jones, M.H.;Wang, Y.C.
    • Steel and Composite Structures
    • /
    • 제8권3호
    • /
    • pp.179-200
    • /
    • 2008
  • This paper reports the results of a recent experimental study into the behavior of welded fin-plate connections to both hollow and concrete filled tubular (CFT) columns under shear. Experiments have been performed at both ambient and elevated temperatures with the aid of an electric kiln. The observed failure modes include fracture of the fin plate and tearing out of the tube around the welds. By considering the results of previously published research, the current design method for similar connections under purely tensile load, in CIDECT Guide 9, based on a deformation limit of 3% of the tube width is shown to be inadequate when evaluating the ultimate strength of such connections. By comparing the results from the current test program which failed in the fin-plate with Eurocode guidance for failure of a fin-plate alone under shear and bending load it is shown that the column face influences the overall connection strength regardless of failure mode. Concrete in-fill is observed to significantly increase the strength of connections over empty specimens, and circular column specimens were observed to exhibit greater strength than similarly proportioned square columns. A finite element (F.E.) model, developed using ABAQUS, is presented and validated against the experimental results in order that extensive parametric tests may be subsequently performed. When validating the model against elevated temperature tests it was found that using reduction factors suggested in published research for the specific steel grades improved results over applying the generic Eurocode elevated temperature steel strength reduction factors.

Performance test of 100 W linear compressor

  • Ko, J.;Koh, D.Y.;Park, S.J.;Kim, H.B.;Hong, Y.J.;Yeom, H.K.
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제15권3호
    • /
    • pp.35-39
    • /
    • 2013
  • In this paper, we present test results of developed 100 W class linear compressor for Stirling-type pulse tube refrigerator. The fabricated linear compressor has dual-opposed configuration, free piston and moving magnet type linear motor. Power transfer, efficiency and required pressure waveform are predicted with designed and measured specifications. In experiments, room temperature test with flow impedance is conducted to evaluate performance of developed linear compressor. Flow impedance is loaded to compressor with metering valve for flow resistance, inertance tube for flow inertance and buffer volumes for flow compliance. Several operating parameters such as input voltage, current, piston displacement and pressure wave are measured for various operating frequency and fixed input current level. Behaviors of dynamics and performance of linear compressor as varying flow impedance are discussed with measured experimental results. The developed linear compressor shows 124 W of input power, 86 % of motor efficiency and 60 % of compressor efficiency at its resonant operating condition.

냉각 조건에 의한 Bi-Pb-Sr-Ca-Cu-O 초전도 선재의 특성 연구 (A study on the superconducting properties of Bi-Pb-Sr-Ca-Cu-O superconducting wire with cooling conditions.)

  • 김민기;최효상;최성환;박성진;한병성
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1993년도 정기총회 및 추계학술대회 논문집 학회본부
    • /
    • pp.213-215
    • /
    • 1993
  • Silver-sheathed Bi-Pb-Sr-Ca-Cu-O wires by the powder-in-tube method were preparated to study on the superconducting properties with cooling conditions. Superconducting wires were cooled down in the furnace, air and liquid $N_2$ after sintering at $840^{\circ}C$. Critical current density of sample cooled in the furnace is $5.1{\times}10^3\;A/cm^2$ at 77K, zero magnetic field and Jc of sample cooled in the air is very low. 2223 high-Tc superconducting phase of sample cooled in the air was distroyed. Therefore, we knew that superconducting wire need to cool slowly to get the high critical current density.

  • PDF

The fabrication of $MgB_2$/SUS Tapes by PIT Process

  • 송규정;이남진;장현만;하홍수;하동우
    • Progress in Superconductivity
    • /
    • 제3권2호
    • /
    • pp.213-217
    • /
    • 2002
  • We have fabricated successfully single-filament composite $MgB_2$/SUS tapes, as an ultrarobust conductor type. The fabrication of the $MgB_2$/SUS tapes was performed by power-in-tube (PIT) process such as swaging and cold rolling. The critical transition temperatures $T_{c}$~38.5 K and ~36 K were observed for the sintered and the nonsintered $MgB_2$/SUS tapes, respectively In addition, the isothermal magnetization M(H) of the sintered $MgB_2$/SUS tapes was measured at temperatures T (between 5 and 50 K) in fields up to 6 T, employing a PPMS-9 (Quantum Design). The persistent current density (J$T_{P}$) values were obtained from the M(H) data, using Bean model, fur the sintered $MgB_2$/SUS tapes. The estimated values were higher than ~ 6$\times$ $10^{5}$ $A/\textrm{cm}^2$ at T = 5 K, with H : 0 G. We also investigated the cross section of the sintered tapes, by using SEM and EDX. An evidence of weak reaction on boundary between $MgB_2$ and SUS tube is found in the SEM and EDX.X.X.X.

  • PDF

탄소섬유쉬트로 구속된 콘크리트충전 각형강관기둥의 단조압축실험 (The Experimental Study on Axial Loaded Concrete Filled Steel Tube Confined by Carbon Fiber Sheet)

  • 박재우;홍영균;홍기섭;이성희;최성모
    • 한국강구조학회 논문집
    • /
    • 제21권3호
    • /
    • pp.311-320
    • /
    • 2009
  • 본 연구에서는 기존 각형 CFT기둥 실험체와 탄소섬유쉬트로 추가구속된 각형 CFT기둥 실험체의 단조압축거동 및 압축내력평가에 관한 실험을 수행하였다. 실험변수는 탄소섬유쉬트 보강겹수와 폭-두께비이며, 실험변수에 따라 총 9개의 실험체를 제작하여 단조압축실험을 수행하였다. 실험을 통하여 기존 CFT 실험체와 탄소섬유쉬트로 구속된 CFT 실험체의 파괴거동, 하중-축변위 곡선, 최대내력, 변형성능을 비교한다. 끝으로 탄소섬유쉬트의 추가구속은 기둥의 국부좌굴을 지연시켰으며 이로 인해 실험체의 최대내력이 상승한 것으로 나타났다.

원전 증기발생기 전열관 와전류검사 보빈탐촉자 설계 (Eddy Current Bobbin Probe Design for Steam Generator Tubes in NPPs)

  • 남민우;이희종;지동현;정지홍;김철기
    • 비파괴검사학회지
    • /
    • 제27권2호
    • /
    • pp.89-96
    • /
    • 2007
  • 원자력발전소 증기발생기 전열관의 건전성을 평가하기 위해서 계획예방정비 기간에 수행되는 와전류검사의 여러 가지 기법중에서 보빈 탐촉자 검사는 가장 기본적인 중요한 검사이다. 와전류 탐촉자는 검사 계통의 핵심적인 부분으로서 특정 절차서에 따라 평가가 이루어질 때 대상 시험체의 합부를 결정하는 자료를 제공하게 된다. 또한, 수집된 와전류신호의 품질은 사용되는 탐촉자의 설계특성, 기하학적 형태, 운전주파수에 따라 결정되고, 검사결과에 미치는 영향이 크기 때문에 와전류검사 탐촉자의 선정은 특히 중요하다. 본 연구에서는 국내 원전 증기발생기 전열관 검사를 위한 최적의 차동형 보빈탐촉자를 설계하였다. 또한 보빈탐촉자 시작품의 전기적 특성과 와전류신호 특성 평가를 수행하여 만족한 결과를 도출하였다.

신경회로망을 이용한 원전SG 세관 결함크기 예측 (Prediction of Defect Size of Steam Generator Tube in Nuclear Power Plant Using Neural Network)

  • 한기원;조남훈;이향범
    • 비파괴검사학회지
    • /
    • 제27권5호
    • /
    • pp.383-392
    • /
    • 2007
  • 본 논문에서는 신경회로망을 이용하여 원자력 발전소 증기발생기 세관의 결함 깊이와 폭을 예측하는 연구를 수행한다. 결함 크기 추정을 위하여 우선, I-In 형태, I-Out 형태, V-In 형태, V-Out 형태의 4가지 결함형상에 대한 와전류탐상시험(ECT) 신호를 생성한다. 특히, 유한요소법에 기반한 수치해석 기법을 이용하여 여러 가지 폭과 깊이를 갖는 결함 400개의 ECT 신호를 생성한다. 이와 같이 생성된 ECT 신호로부터, 결함 크기와 폭을 예측하기 위한 새로운 특징벡터를 추출하는데, 이 특징벡터에는 최대 임피던스 값을 갖는 점과 최대 임피던스값의 1/2의 값을 갖는 점 사이의 위상각이 포함된다. 추출된 특징벡터를 이용하여 결함의 크기를 예측하기 위해서 하나의 은닉층을 갖는 다층퍼셉트론을 이용하였다. 컴퓨터 모의실험 연구를 통하여 제안된 방법이 우수한 예측성능을 갖는다는 것을 보였다.

진단용 X선 기기의 고전압 발생장치 개발 (Development of High Voltage Generator for Diagnostic X-ray Equipment)

  • 김영표;김태곤;천민우;박용필
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2010년도 추계학술대회
    • /
    • pp.764-765
    • /
    • 2010
  • 인체의 진단에 사용되는 의료용 X선 기기는 비 침습적인 방법으로 인체 내부의 진단이 가능하여 의료기관에서 진단에 매우 큰 비중을 차지하고 있다. X선의 발생에 가장 중요한 고전압 발생장치는 기존 변압기 식이 주로 사용되었으나 크고 무거우며 직류 고전압의 리플이 커서 발생효율이 낮다. 이러한 단점을 보완하기 위해 인버터를 사용하여 입력전원의 주파수를 고주파하는 인버터 방식의 고전압 발생장치가 주로 사용되고 있다. 본 연구에서는 펄스폭 변조 방식을 적용하여 관전압과 관전류의 동작을 제어 하였으며, 오실로 스코프를 이용하여 동작 결과를 확인하였다.

  • PDF

전기화학적 방법에 의한 내열강의 열화도측정 제2보 : 열화도측정치에 미치는 측정조건들의 영향과 기계적성질 변화에 대해서 (Degradation Degree Evaluation of Heat Resisting Steel by Electrochemical Technique Part 2 : Effect of Testing Conditions on Evaluation Value of Degradation Degree and Changes of Mechaical Properties)

  • 정희돈;권영각;장래웅
    • 대한기계학회논문집
    • /
    • 제17권2호
    • /
    • pp.300-312
    • /
    • 1993
  • The material deterioration of service-exposed boiler tube steels in fossil power plant was evaluated by using the electrochemical technique namely, modified electrochemical potentiokinetic reactivation(EPR). It was focused that the passivation of Mo$_{6}$C carbide which governs the mechanical properties of Mo alloyed steels did not occur even in the passivity region of steel in sodium molybdate solution and the reactivation peak current (Ip) observed as the result of non-passivation indicating the precipitation of Mo$_{6}$C carbides. To obtain the optimal test conditions for the field test by using the specially designed electrochemical cell, the effects of scan rate, the surface roughness and the pH of electrolyte on Ip value were also investigated. Furthermore, the change of mechanical properties occurred during the long time exposure at high temperature was evlauated quantitatively by small punch(SP) tests and micro hardness test taking account of the metallurgical changes. It is known that reactivation peak current (Ip) has a good relationship with Larson-Miller Parameter(LMP) which represents the information about material deterioration occurred at high temperature environment. In addition it was possible to estimate the ductile-brittle transition temperature (DBTT) by means of the SP test. The Sp test could be, therefore, suggested as a reliable test method for evaluating the material degradation of boiler tube steels. From the good correaltion between the SP DBTT and Ip values shown in this study, it was knows that the change of mechanical properties could be evaluated non-destructively by measurring only Ip values.ues.