• Title/Summary/Keyword: Tube array

Search Result 142, Processing Time 0.037 seconds

Design and Array Signal Suggestion of Array Type Pulsed Eddy Current Probe for Health Monitoring of Metal Tubes (금속배관 건전성 감시를 위한 배열형 펄스와전류 탐촉자의 설계 및 배열신호 제안)

  • Shin, Young Kil
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.35 no.5
    • /
    • pp.291-298
    • /
    • 2015
  • An array type probe for monitoring metal tubes is proposed in this paper which utilizes peak value and peak time of a pulsed eddy current(PEC) signal. The probe consists of an array of encircling coils along a tube and the outside of coils is shielded by ferrite to prevent source magnetic fields from directly affecting sensor signals since it is the magnetic fields produced by eddy currents that reflect the condition of metal tubes. The positions of both exciter and sensor coils are consecutively moved automatically so that manual scanning is not necessary. At one position of send-receive coils, peak value and peak time are extracted from a sensor PEC signal and these data are accumulated for all positions to form an array type peak value signal and an array type peak time signal. Numerical simulation was performed using the backward difference method in time and the finite element method for spatial analysis. Simulation results showed that peak value increases and the peak appears earlier as the defect depth or length increases. The proposed array signals are shown to be excellent in reflecting the defect location as well as variations of defect depth and length within the array probe.

High Efficient Structure of Plasma Tubes

  • Ishimoto, Manabu;Tokai, Akira;Shinohe, Koji;Awamoto, Kenji;Shinoda, Tsutae
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.103-108
    • /
    • 2004
  • The plasma tube array display is expected to realize the wall size display with very high luminous efficacy. The cell design for high luminous efficacy was investigated. Also discharging in plasma tube was observed to investigate the structure for high luminous efficacy. As the result, high luminous efficacy of 5.4 lm/W was achieved.

  • PDF

Optimization of Nd:YAG laser welding parameters for sealing the small Ti tube ends (소형 티타늄 튜브 끝의 밀봉용접을 위한 Nd:YAG 레이저 용접조건의 최적화)

  • Lee Hyeong Geun;Han Hyeon Su;Son Gwang Jae;Hong Sun Bok
    • Proceedings of the KWS Conference
    • /
    • v.43
    • /
    • pp.73-75
    • /
    • 2004
  • The purpose of this study is to optimize Nd:YAG laser welding parameters to seaz a Rf source into a Ti micro capsule. Ti tube ends can be sealed as some length of ぉbe end is melted and coalesced. The exact control of the melted length is the most important to get sound sealing. The Nozzle type, tube rotating speed, tilt angle, focal position, pumping voltage, pulse frequency and pulse width were selected as the Nd:YAG laser welding Parameters. These Parameters were optimized by the Taguchi experimental method using 115 orthogonal array. Appearance and cross section of the seated tube ends were examined by SEM.

  • PDF

A Study on Performance Characteristics of Heat Exchanger for Heat Pump with R410A Refrigerant (R410A 냉매를 사용한 열펌프용 열교환기의 형상에 따른 성능특성 연구)

  • 정규하;박윤철;오상경
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.4
    • /
    • pp.340-348
    • /
    • 2004
  • The air and refrigerant side heat transfer performances are key parameters to improve heat transfer efficiency of the heat exchanger including the fan performance. Design of the fins, treatment of the tube inside, tube diameter and tube array effect heat transfer performance of the heat exchanger. The heat exchanger is used as a condenser at cooling mode and used as an evaporator at heating mode in the heat pump system. The heat pump system uses R410A as the refrigerant. The heat exchangers are consisted with 7 mm diameter tubes with slit-type fins. The study was conducted with variation of arrangement of the refrigerant path and air flow rate and refrigerant pressure drop and heat transfer rate were measured with a code tester. The capacity of the 3 path heat exchanger is more efficient than 2 or 4 path heat exchangers in heating or cooling modes.

Numerical Analysis of Hydrodynamic mass for various Tube Arrays in a circular cylindrical shell (원통 내부의 전열관 배열에 따른 유체부가질량특성 수치해석)

  • Yang, Keum-Hee;Ryu, Ki-Wahn;Park, Chi-Yong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2011.04a
    • /
    • pp.693-699
    • /
    • 2011
  • The outermost SG tubes have more structural problems than inside tubes. Many studies have used a uniform added mass coefficient for all of the SG tubes during the FIV analysis. The purpose of this study is to find out the added mass coefficients for each tube in a cylindrical shell. When a number of tubes are increased, added mass coefficients are also increased. And added mass coefficients at outermost tubes are less than those of inside tubes. According to gap changes between outermost tube and cylindrical shell, added mass coefficients are decreased with increasing the gap. When the gap has very large value, it shows that the added mass coefficient is asymptotically converged to the value of the tube array in a free fluid field.

  • PDF

An Experimental Study on Heat Transfer Enhancement of Cross Flow Heat Exchanger Using Screen (스크린을 이용한 직교류 열교환기의 열전달 촉진에 관한 연구)

  • Yoo, Seong-Yeon;Jang, Kwang-Il;Kwon, Hwa-Kil
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.185-190
    • /
    • 2007
  • For the successful design of heat exchangers, it is very important to understand local heat transfer characteristics on the circular cylinder of the cross flow heat exchangers. In this study, the heat exchanger using screen is developed to enhance heat transfer. The naphthalene sublimation technique is employed to measure the local heat transfer coefficients in the heat exchanger. The experiments are performed for single circular tube, in-line array tube bank with and without heat transfer promoter. Local Nusselt numbers of single circular tube and tube bank with heat transfer promoter are investigated and compared to those of without heat transfer promoter.

  • PDF

Development of a position sensitive CsI(Tl) crystal array

  • Shi, Guo-Zhu;Chen, Ruo-Fu;Chen, Kun;Shen, Ai-Hua;Zhang, Xiu-Ling;Chen, Jin-Da;Du, Cheng-Ming;Hu, Zheng-Guo;Fan, Guang-Wei
    • Nuclear Engineering and Technology
    • /
    • v.52 no.4
    • /
    • pp.835-840
    • /
    • 2020
  • A position-sensitive CsI(Tl) crystal array coupled with the multi-anode position sensitive photomultiplier tube (PS-PMT), Hamamatsu H8500C, has been developed at the Institute of Modern Physics. An effective, fast, and economical readout circuit based on discretized positioning circuit (DPC) bridge was designed for the 64-channel multi-anode flat panel PSPMT. The horizontal and vertical position resolutions are 0.58 mm and 0.63 mm respectively for the 1.0 × 1.0 × 5.0 ㎣ CsI(Tl) array, and the horizontal and vertical position resolutions are 0.86 mm and 0.80 mm respectively for the 2.0 × 2.0 × 10.0 ㎣ CsI(Tl) array. These results show that the CsI(Tl) crystal array with low cost could be applied in the fields of medical imaging and high-resolution gamma camera.

A Study on the Acoustic Baffle to Reduce Ghost Target According to Structure behind Cylindrical Array Sensor (원통형 배열센서 후면 구조물에 의해 발생하는 허위 표적 감소를 위한 음향 배플 연구)

  • Seo, Young Soo;Kim, Dong Hyun;Kim, Jin Tae
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.25 no.6
    • /
    • pp.440-446
    • /
    • 2015
  • Acoustic signal is emitted from a vessel and received by a cylindrical array sensor at some distance from the vessel. Acoustic signal is the source for a cylindrical array sensor which is designed to detect the acoustic signal. Cylindrical array sensors seldom have an ideal hydrodynamic shape and are not sufficiently robust to survive without some protection and they are normally housed in a sonar dome. Reflected signals by some structure inside a sonar dome make unwanted signals. Therefore, an acoustic baffle is used to minimize unwanted signals. The performance of the acoustic baffles can be determined from the acoustic numerical analysis at the design stage. In this study, finite element method was used to analyze the acoustic field around the cylindrical array sensor and baffle effects. The baffle performance can be defined the echo reduction. To show the baffle performance, the specimens were made for pulse tube test and echo reductions were measured during the test. In this paper, the effect of echo reduction of the acoustic baffle was discussed.

Development of a Small Animal CT using a Linear Detector Array and Small-Scale Slip Rings

  • An Ung Hwan;Chun In Kon;Lee Sang Chul;Cho Min Hyoung;Lee Soo Yeol
    • Journal of Biomedical Engineering Research
    • /
    • v.26 no.1
    • /
    • pp.43-47
    • /
    • 2005
  • We have developed a small bore x-ray CT for small animal imaging with a linear x-ray detector array and small-scale slip rings. The linear x-ray detector array consists of 1024 elements of 400□m×400□m with a gadolinium oxysulfide (GOS) scintillator on top of them. To avoid use of expensive large diameter slip rings for projection data transmission from the X­ray detector to the image reconstruction system, we used the wireless LAN technology. The projection data are temporally stored in the data acquisition system residing on the rotating gantry during the scan and they are transmitted to the image reconstruction system after the scan. With the wireless LAN technology, we only needed to use small-scale slip rings to deliver the AC electric power to the X-ray generator and the power supply on the rotating gantry. The performances of the small animal CT system, such as SNR, contrast, and spatial resolution, have been evaluated through experiments using various phantoms. It has been experimentally found that the SNR is almost linearly proportional to the tube current and tube voltage, and the minimum resolvable contrast is less than 30 CT numbers at 40kVp/3.0㎃. The spatial resolution of the small animal CT system has been found to be about 0.9Ip/㎜. Postmortem images of a piglet is also presented.

A Study on Manufacturing Process Control and Monitoring System for Heat-Shrink-Tube Cutting Machine (열 수축 튜브 자동 절단 장치를 위한 공정제어 및 감시 시스템에 관한 연구)

  • Kim, Hyoung-Seok;Lee, Byung-Ryong;Yun, Ho-Young
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.32 no.12
    • /
    • pp.1140-1145
    • /
    • 2008
  • In conventional cutting system of Heat-Shrink-Tube, workers operate cutting system after considering about length and quantity of heat-shrink-tube. So, not only work time and production cost is increased but also material is wasted because the data that workers have to consider is so much. In this paper, an effective cutting system of heat-shrink-tube was developed to reduce production cost, work time and waste of material. The cutting system consists of a supervisory computer installed inside a control room, a on-site computer installed on the work area, and a PLC system. In the developed system, a supervisory computer send work order to the on-site computer using LAN and the on-site computer operates the cutting system of the heatshrink-tube after it makes an array production order. Also, the on-site computer reports information to the supervisory computer when an accident happened.