• Title/Summary/Keyword: Tube Type

Search Result 1,617, Processing Time 0.03 seconds

A Study for Performance Improvements in the Coaxial Type Stirling Pulse Tube Cryocooler (동축형 스털링 맥동관 냉동기의 성능개선에 관한 연구)

  • Park, S.J.;Hong, Y.J.;Kim, H.B.;Kim, Y.H.
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.1329-1334
    • /
    • 2004
  • The most compact and convenient pulse tube cryocooler for practical applications is the coaxial type. It can replace Stirling cryocooler without any change to the Dewar or the connection to the cooled devices. The experimental results of the coaxial inertance tube pulse tube cryocooler for cooling superconductor RF filter are presented in this paper. To find optimal conditions of inertance tube pulse tube cryocooler, no load temperature according to the variations of inertance tube volume, reservoir volume are measured, and the cool down characteristics at the particular conditions are presented. In case of the coaxial type inertance tube pulse tube refrigerator, cool down time is the lowest in the inertance tube diameter of 1.3 mm and inertance tube length of 1900 mm and lowest temperature is 112K. This results are not satisfactory for practical applications. So, We propose vacuum insulation between regenerator and pulse tube in the Stirling type coaxial pulse tube cryocooler. Stirling type coaxial pulse tube cryocooler with the vacuum insulation between regenerator and pulse tube was designed and manufactured by KIMM(Korea Institute of Machinery and Materials). The optimal conditions will be tested for Stirling type coaxial pulse tube cryocooler with the vacuum insulation between regenerator and pulse tube.

  • PDF

Flow and Heat Transfer Characteristics of Tube-and-Plate Condenser with Different Plate Shapes and Inlet Geometries using Numerical Analysis (수치해석에 의한 TUBE-AND-PLATE형 응축기의 판 형태 및 입구 형상변화에 따른 유동 및 열전달 특성)

  • Choi, W.J.;Kwon, O.B.;Lim, H.C.;Kim, M.K.;Lee, Y.S.
    • Journal of Power System Engineering
    • /
    • v.13 no.2
    • /
    • pp.49-55
    • /
    • 2009
  • Recently, a study on condensers for refrigerators has focused on new model which will cost less and will be more efficient. Some widely used condensers for domestic refrigerators are wire-and-tube type condenser, hot-wall type condenser, and spiral type condenser. Some companies which use the spiral type condenser at the moment try to develop a new tube-and-plate type condenser which will cost less and will be as efficient as the spiral type. As a standard condenser type, tube-and-plate type condenser is used in this study. A two-dimensional numerical model for the tube-and-plate type condenser is proposed, and the flow and heat transfer characteristics for several types of condensers are investigated.

  • PDF

Heat Transfer Performance of Evaporator Used in a Domestic Refrigerator/Freezer Under Frosting Condition (착상을 고려한 가정용 냉동/냉장고 증발기의 열전달 성능)

  • Lee Jang-Seok;Lee Kwan-Soo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.1
    • /
    • pp.62-70
    • /
    • 2005
  • In this study, the air-side heat transfer coefficients of several types of evaporators in the household freezer/refrigerators are investigated. The types considered in this work are: discrete flat plate fin-and-tube type(in-lined tube array), continuous flat plate fin-and-tube type(staggered tube array), and spine fin-and-tube type(in-lined tube array). The heat transfer correlations obtained from this study for each heat exchangers could expect heat transfer coefficients less than $5\%$ of errors. The result indicates that the air-side heat transfer performance of spine fin-and-tube type evaporator shows the highest value under dry conditions, but discrete flat plate fin-and-tube type evaporator shows the highest value among these three evaporators under frosting conditions.

An Experimental Study on the 1st Harmonic Characteristic for open-tube-type and close-tube-type Thermoacoustic Refrigerators (개방관형과 밀폐관형 열음향 냉동기의 1차 하모닉에 관한 특성 연구)

  • 송규조;박종호;고득용;박성제;김효봉;정철진
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2002.02a
    • /
    • pp.189-192
    • /
    • 2002
  • In this study, The experimental open-tube-type and close-tube-type thermoacoustic refrigerator were constructed. The resonant characteristics of a thermoacoustic refrigerator were investigated. In order to determine the optimum resonant tube length and frequency, We changed the length of resonant tube from 400mm to 850mm and the frequency from 100Hz to 1000Hz. In case of first harmonic, the temperature difference of open-tube-type (1/4 wave) refrigerator was $41^{\circ}C$(resonator length :500mm). The temperature difference of close-tube-type (1/2 wave) refrigerator was $43^{\circ}C$(resonator length :850mm). In this experiments, the experimental 1/2 wave refrigerator is slightly cooler than the experimental l/4 wave refrigerator.

  • PDF

Experimental study on the characteristics of heat transfer for new type aluminum tube (신형 알루미늄관의 열전달 특성에 관한 실험적 연구)

  • 문춘근;윤정인;김재돌
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.24 no.2
    • /
    • pp.31-37
    • /
    • 2000
  • This study investigated heat transfer characteristics of refrigeration system using new type aluminium heat transfer tube for evaporator of refrigeration and air-conditioning comparing with bare tube. From the result of heat transfer experiment form one phase flow using cooled and hot water, about 20% heat transfer performance is superior in case of same quantity of flow and about 4% heat transfer performance if superior in case of same velocity comparing with bare tube. Casing of two phase flow, heat transfer performance of new type aluminum heat transfer tube shows about 50% superior heat transfer performance comparing with bare tube in the same evaporating pressure when using heat transfer tube as evaporator and shows about 47% increase when expressing performance coefficient as the rate of refrigerating capacity and compressing work. However, it can be known that pressure drop in the heat transfer tube is taken higher value of about 18% in case of new type aluminum heat transfer tube. From the above result, new type aluminum heat transfer tube is excellent comparing with bare heat transfer tube using the existing heat exchanger for refrigerator.

  • PDF

Cooling Heat Transfer Characteristics of CO2 in a Brazing Type Small Diameter Copper Tube (브레이징식 동세관내 CO2의 냉각 열전달 특성)

  • Oh, Hoo-Kyu;Son, Chang-Hyo
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.33 no.6
    • /
    • pp.827-834
    • /
    • 2009
  • The cooling heat transfer coefficient of $CO_2$ in a brazing type small diameter tube was investigated experimentally. The main components of the refrigerant loop are a receiver, a $CO_2$ compressor, a mass flow meter, an evaporator and a brazing type small diameter tube as a test section. The mass flux of $CO_2$ is $400{\sim}1600$ [kg/$m^2s$], the mass flowrate of coolant were varied from 0.15 to 0.3 [kg/s], and the cooling pressure of gas cooler were from 8 to 10 [MPa]. The cooling heat transfer coefficients of the brazing type small diameter copper tube is about $4{\sim}11.7%$ higher than that of the conventional type small diameter copper tube. In comparison with test results and existing correlations, correlations failed to predict the cooling heat transfer coefficient of $CO_2$ in a brazing type small diameter copper tube. therefore, it is necessary to develope reliable and accurate predictions determining the cooling heat transfer coefficient of $CO_2$ in a brazing type small diameter copper tube.

A Study on the Fluid Flow of Vortex Nozzle for Generating Micro-bubble (미세버블 발생용 보텍스 노즐의 유체유동에 대한 연구)

  • Yu, Seong-Hun;Park, Sang-Hee;Kang, Woo-Jin;Han, Seung-Wook
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.25 no.4_2
    • /
    • pp.637-644
    • /
    • 2022
  • In this study, the flow characteristics according to the shape of the vortex nozzle was studied by numerical analysis and the amount of microbubble generation was measured experimentally. The shape of the vortex nozzle is cylindrical, diffuser, and conical type. The axial fluid velocity in the induced tube gradually increased from the inlet to the outlet. In particular, the fluid velocity in the nozzle part increased rapidly. The velocity distribution of the fluid at the inlet of the induced tube showed that the flow rotates counterclockwise in the outer region and the inner center of the induced tube. At the outlet of the induced tube, the cylindrical and conical type showed rotational flow, and the diffuser type showed irregular turbulent flow. The dimensionless pressure ratio 𝜂 of the inner region of the induced tube was lower than that of the outer region. Also, 𝜂 near the outlet of the induced tube in cylindrical and conical type showed a similar tendency to the inlet area. At the outer region of inlet of induced tube, intense vorticity was observed on the wall and in lower region. At the inner region of inlet of induced tube, intense vorticity was observed on the inner wall of the induced tube and in the central region of the inlet of the induced tube. At the outlet of induced tube, in the case of the cylindrical and conical type, intense vorticity was observed near the inner wall, the diffuser type showed irregular strong vorticity inside the tube. The total number of bubbles measured was the most in the cylindrical type, and the microbubbles less than 50mm occurred the most in the conical type.

An Analytical Study on the Improvement of the Performance of Swivel Valve Tube Couplers (스위벨 밸브 튜브 커플러 개발을 위한 해석 연구)

  • Lee, Jun-Ho;Sung, Jae-Kyeong
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.10 no.3
    • /
    • pp.1-6
    • /
    • 2011
  • This study focused on the localization of swivel type tube couplers, which all depend on imports. In this study, a computer application analysis was performed using a finite element method as a preliminary study. In the major developments related to the objective of this study, the air brake system produced by car makers represents a different in the installation point of an air tank according to the type of cars or in the length and direction of its hoses and that leads to cause lots of problems. For solving such problems, the design of the major elements in a swivel type tube coupler was analyzed using a finite element method, and its validity was also verified. In the process that verifies the validity of this study, it was necessary to investigate how much external force affects the desorption of the tube support, which is the most important element in swivel type tube couplers. For achieving the investigation, a pressure test was implemented for the tube support according to the Federal Motor Vehicle Safety Standards(FMVSS). In the results of the pressure test, all samples satisfied the FMVSS. In addition, several tests were implemented by installing the sample of the developed swivel type tube coupler to an actual vehicle. In particular, rotation tests with various angles were applied by welding the swivel type coupler to an air tank through an argon welding process. In the results of the installing test for an actual vehicle, it was verified that the designed structure was determined as a structure that is able to endure the eccentric torque and deformation pressure applied to several directions that are the major problems in such fixed type tube couplers. Therefore, in the comparison of the performance of the developed product with the product of PARKER, it was possible to verify that the localized swivel type tube coupler developed in this study shows more excellent than that of the existing products by PARKER.

A study on the in-line type inertance tube pulse tube cryocooler for cooling Superconductor filter

  • Park, Seong-Je;Hong, Yong-Ju;Kim, Hyo-Bong;Kim, Seon-Young;Jung, Woo-Seok
    • Progress in Superconductivity and Cryogenics
    • /
    • v.6 no.4
    • /
    • pp.46-50
    • /
    • 2004
  • The Experimental results of the in-line type inertance tube pulse tube cryocooler for cooling superconductor RF filter are presented in this paper. The pulse tube refrigerator, which has no moving parts at its cold section, is attractive in obtaining higher reliability, simpler construction, and lower vibration than any other small refrigerators. The purpose of this study is to analyze the characteristics of in-line type inertance tube pulse tube refrigerator (IPTR), and to get main factor to improve the performance of the in-line type IPTR. Firstly, design parameters of the in-line IPTR are discussed by ARCOPTR program, and then to find optimal conditions of in-line type IPTR, cool down characteristics according to the variations of the charging pressure, inertance tube volume, regenerator volume and pulse tube volume are measured by the experiment. The lowest temperature of the cold end was about 50 K. Cooling capacity was the highest in the charging pressure of 32 atm. and 5W at 72K. On the other hand, COP of the in-line type IPTR was the highest in the charging pressure of 21 atm. and 0.018 at 77K.

Oil Cooler Design Automation on the Cooling of Machine Tool Cutting Oil (공작기계 절삭유 냉각용 오일쿨러 설계 자동화)

  • 권혁홍
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.8 no.1
    • /
    • pp.89-99
    • /
    • 1999
  • The automatic design of shell & tube type oil cooler can be used in real industrial environments. Since the automatic design system is intended to be used in small companies, it is designed to be operated well under environments of CAD package in the personal computer. It has adopted GUI in design system, and has employed DCl language. Design parameters to be considered in the design stage of shell and tube type oil cooler are type of oil cooler, outer diameter, thickness, length of tube, tube arrangement, tube pitch, flow rate, inlet and outlet temperature, physical properties, premissive pressure loss on both sides, type of baffle plate, baffle plate cutting ratio, clearance between baffle plate outer diameter and shell inner diameter and clearance between baffle plate holes. As a result, the automatic design system of shell & tube type oil cooler is constructed by the environment of CAD software using LISP. We have built database of design data for various kinds of shell & tube type oil coolers. The automatic design system have been assessed and compared with existing specification of design. Good agreement with Handbook of heat exchanger and design dta of real industrial environments has been found.

  • PDF