• Title/Summary/Keyword: Tube Specimen

Search Result 261, Processing Time 0.033 seconds

Monotonic Loading Test for CFT Square Column-to-Beam Partially Restrained Composite Connection (CFT 각형 기둥-보 합성 반강접 접합부의 단조가력 실험)

  • Choi, Sung Mo;Park, Su Hee;Park, Young Wook;Kim, Jin Ho
    • Journal of Korean Society of Steel Construction
    • /
    • v.17 no.3 s.76
    • /
    • pp.325-335
    • /
    • 2005
  • This study tackles the development of an improved detail of partially restrained CFT square column-to-beam connection and the evaluation of its mechanical behavior under monotonic loading. The connection is designed to strengthen shearing capacity at the bottom of the connection due to the ultimate behavior of PR-CC by its detail of the bottom connection and simplify the fabrication process. The suggested connection is the welded bottom beam flange connection(M-2) and is compared with the existing PR-CC of bolted seat angle connection(M-1). Two specimens were fabricated in actual size and tested under monotonic loading. Based on the test results, the welded bottom beam flange connection exhibited about 85% of the stiffness of steel beam. It was similar to the bolted seat angle connection and behaved as PR-CC. The specimen of the supposed connection type failed at the shear connection of web but was similar to the bolted seat angle connection until the failure. It obtained sufficient stiffness and capacity through the reinforcingsteel and the capacity and deformational ability equivalent to the full-plastic moment through the anchor inside the steel tube at the web connection. So, it can be said that the suggested connection exhibits sufficient ductile behavior.

Influence factor analysis on the measurement of smoke density from floor materials in rolling stock (철도차량 바닥재 연기밀도 측정의 영향인자분석)

  • Kwon, Tae-Soon;Lee, Duck-Hee;Park, Won-Hee
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.11
    • /
    • pp.629-634
    • /
    • 2016
  • In this study, we investigated the effect of factors that influence the measurement of smoke density using synthetic rubber flooring. The characteristics of rolling stock in an enclosed environment can cause enormous loss of life by smoke inhalation during fires inside passenger cars. The amount of smoke generation from interior materials for rolling stock is strictly restricted domestically and in other countries. Precise measurement of smoke density is therefore required to assess the fire performance of interior materials. Major factors that influence the measurement of smoke density include the uniformity of the specimen, the variations in conditions and instruments, and the operational and maintenance environment of the instruments. The contribution of factors was analyzed by estimating the uncertainty to investigate the contribution ratios of the major factors. The results show a contribution ratio of about 86% for the variation from the measurement of light transmission using a photomultiplier tube. Thus, this factor was the most representative for the measurement of smoke density. The contribution ratio of the other factors was low at about 11%, including irradiant flux conditions (${\pm}0.5 kW/m^2$) and the influence of the operational and maintenance environment of the instrument. These results were obtained using specimens with high uniformity.

Effect of morphology and diameter of implant fixture-abutment connection on mechanical failure of implants (임플랜트 고정체-지대주 연결부의 형태와 직경이 임플랜트의 기계적 실패에 미치는 영향)

  • Yun, Bo-Hyeok;Shin, Hyon-Mo;Yun, Mi-Jung;Huh, Jung-Bo;Jeong, Chang-Mo;Kang, Eun-Sook
    • The Journal of the Korean dental association
    • /
    • v.53 no.9
    • /
    • pp.644-655
    • /
    • 2015
  • Purpose: This study was conducted to evaluate the effect of the fixture abutment connection type and diameter on the screw joint stability in external butt joint for 2nd surgery and internal cone connected type implant system for 1st and 2nd surgery using ultimate fracture strength. Materials and Methods: USII system, SSII system and GSII system of Osstem Implant were used. Each system used the fixture with two different diameters and cement-retained abutments, and tungsten carbide / carbon coated abutment screws were used. Disc shaped stainless steel metal tube was attached using resin-based temporary cement. The experimental group was divided into seven subgroups, including the platform switching shaped specimen that uses a regular abutment in the fixture with a wide diameter in USII system. A static load was increased to the metal tube at 5mm deviated point from the implant central axis until it reached the compression bending strength at a rate of 1mm/min. Then the deformations and patterns of fracture in threaded connection were compared. Results and Conclusion: 1. In the comparison between the Regular diameter, compression bending strength of SSII system was higher than USII system and GSII system. There was no significant difference between USII system and GSII system. 2. In the comparison between wide diameter, compression bending strength was increased in the order of GSII system, USII system, and SSII system. 3. In comparison between the implant diameter, compression bending strength of the wide diameter was greater than the regular diameter in any system(P<0.05). 4. There was no significant difference between the platform switching (III group) and the regular diameter (I group) in USII system. 5. In USII system, fracture of abutment screw and deformation of both fixture and abutment were observed in I, II and III subgroups. 6. Failure pattern of SSII system, which was the fracture of abutment screw and deformation of the abutment and fixture, was observed in both IV and V subgroups. Fracture of some fixtures was observed in subgroup V. 7. Failure pattern of GSII system, which was the fracture of the abutment screw and deformation of the fixture and the abutment, was observed in both VI and VII subgroups. Apart from other subgroups, subgroup VII demonstrated no bending neither the fracture at the top of the fixture. The compressive deformation of internal slope in the fixture was the only thing observed in subgroup VII.

Long-Term Behavior of Square CFT Columns with Diaphragm (격막이 설치된 각형 CFT 기둥의 장기거동에 관한 연구)

  • Kwon Seung-Hee;Kim Tae-Hwan;Kim Yun-Yong;Kim Jin-keun
    • Journal of the Korea Concrete Institute
    • /
    • v.17 no.6 s.90
    • /
    • pp.1025-1032
    • /
    • 2005
  • This paper presents experimental and analytical studies on long-term behavior of square CFT columns with diaphragm. In order to investigate the effect of the diaphragm on the long~term behavior, experiments for six specimens with two diaphragms and three different column length, and three-dimensional finite element analysis for each specimen have been performed. The finite element models considering the interface behavior between the steel tube and the inner concrete were verified from comparison of the test results with the analysis results. From the test and the analysis results, the following conclusions were obtained. The confinement effect created by the diaphragm does not depends on column length and influences only a part of the whole column that is from the end to the depth which is the same to the width of the column. The shortening of the column with diaphragm which covers more than a half of the cross sectional area of the inner concrete is the same as that of the column under a load applied on the steel tube and the entire section of the inner concrete.

MICROSHEAR BOND STRENGTH OF ADHESIVES ACCORDING TO THE DIRECTION OF ENAMEL RODS (법랑소주 방향에 따른 접착제의 미세전단 결합강도)

  • Cho, Young-Gon;Kim, Jong-Jin
    • Restorative Dentistry and Endodontics
    • /
    • v.30 no.4
    • /
    • pp.344-351
    • /
    • 2005
  • This study compared the microshear bond strength $({\mu}SBS)$ to end and side of enamel rod bonded by four adhesives including two total etch adhesives and two self-etch adhesives. Crown segments of extracted human molars were cut mesiodistally. The outer buccal or lingual surface was used as specimens cutting the ends of enamel rods, and inner slabs used as specimens cutting the sides of enamel rods. They were assigned to four groups by used adhesives: Group 1 (All-Bond 2), Group 2 (Single Bond), Group 3 (Tyrian SPE/One-Step Plus), Group 4 (Adper Prompt L-Pop). After each adhesive was applied to enamel surface, three composite cylinders were adhered to it of each specimen using Tygon tube. After storage in distilled water for 24 hours, the bonded specimens were subjected to ${\mu}SBS$ testing with a crosshead speed of 1 mm/minute. The results of this study were as follows: 1. The $({\mu}SBS)$ of Group 2 $(16.50\pm2.31 MPa)$ and Group 4 $(15.83\pm2.33 MPa)$ to the end of enamel prism was significantly higher than that of Group 1 $(11.93\pm2.25 MPa)$ and Group 3 $(11.97\pm2.05 MPa)$ (p<0.05). 2. The $({\mu}SBS)$ of Group 2 $(13.43\pm2.93 MPa)$ to the side of enamel prism was significantly higher than that of Group 1 $(8.64\pm1.53 MPa)$, Group 3 $(9.69\pm1.80 MPa)$, and Group 4 $(10.56 \pm1.75 MPa)$ (p<0.05), 3. The mean $({\mu}SBS)$ to the end of enamel rod was significantly higher than that to the side of enamel rod in all group (p<0.05).

Cyclic Loading Test for Beam-to-Column Connections of Concrete Encased CFT Column (콘크리트피복충전 각형강관 기둥-보 접합부의 주기하중 실험)

  • Park, Hong Gun;Lee, Ho Jun;Park, Sung Soon;Kim, Sung Bae
    • Journal of Korean Society of Steel Construction
    • /
    • v.26 no.1
    • /
    • pp.55-68
    • /
    • 2014
  • In this study, the beam-to column connections of concrete-encased-and-filled steel tube columns were tested under cyclic loading. Two specimens using steel beams and two specimens using precast concrete beams were tested. The dimension of the column cross section was $670mm{\pm}670mm$. The beam depths were 488mm and 588mm for the steel beams and 700mm for the precast concrete beams. The longitudinal bar ratios of the precast concrete beams were 1.1% and 1.5%. For the connections to the steel beams, continuity plates were used in the tube columns. For the connections to the PC beams, couplers were used for beam re-bar connections. The test results showed that except for a specimen, deformation capacities of the specimens were greater than 4% rotation angle, which is the requirement for the Special Moment Frame. Particularly, specimens using precast concrete beam showed excellent performances in the strength, deformation, and energy dissipation.

In Vitro imaging of MRI and Ultrasound for Colorectal Carcinoma (직결장암 조직의 자기공명영상과 초음파 소견에 대한 비교 연구)

  • Lee, Hwang Kyu;Jee, Keum Nahn;Hong, Sujin;Koh, Jae Hyang
    • Investigative Magnetic Resonance Imaging
    • /
    • v.17 no.2
    • /
    • pp.133-143
    • /
    • 2013
  • Purpose : To evaluate and compare the accuracy of magnetic resonance imaging (MRI) and ultrasound (US) for detection and estimation of invasion depth of colorectal carcinoma (CRC) by correlation with histopathologic findings in vitro, and to find out the best MR pulse sequence for accurate delineation of tumor from surrounding normal tissue. Materials and Methods: Resected specimens of CRC from 45 patients were examined about tumor detectability and invasion depth of US using high frequency (5-17 MHz) linear transducer in a tube filled with normal saline and MRI in a 8-channel quadrate head coil. The institutional review board approved this study and informed consent was waived. MRI with seven pulse sequences of in- and out-of-phases gradient echo T1 weighted images, fast spin echo T2 weighted image and its fat suppression image, fast imaging employing steady-state acquisition (FIESTA) and its fat suppression image, and diffusion weighted image (DWI) were performed. In each case, both imaging findings of MRI and US were evaluated independently for detection and estimation of invasion depth of tumor by consensus of two radiologists and were compared about diagnostic accuracy according to the histopathologic findings as reference standard. Seven MR pulse sequences were evaluated on the point of accurate delineation of tumor from surrounding normal tissue in each specimen. Results: In specimens of CRC, both imaging modalities of MRI (91.1%) and US (86.7%) showed relatively high diagnostic accuracy to detect tumor and evaluate invasion depth of tumor. In early CRC, diagnostic accuracy of US was 87.5% and that of MRI was 75.0%. There was no statistically significant difference between two imaging modalities (p > 0.05). The best pulse sequence among seven MR sequences for accurate delineation of tumor from surrounding normal tissue in each specimen of CRC was fast spin echo T2 weighted image. Conclusion: MRI and US show relatively high diagnostic accuracy to detect tumor and evaluate invasion depth of resected specimen of CRC. The most excellent pulse sequence of MRI for accurate delineation of tumor from surrounding normal tissue in CRC is fast spin echo T2 weighted image.

Report on the improvement of the in vitro and specimen reception environment system (핵의학과 검체 접수 환경시스템의 개선사례 보고)

  • Kim, Jung In;Kang, Mi Ji;Kim, Na Kyung;Park, Ji Sol;Kwon, Won Hyun;Lee, Kyung Jae
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.25 no.2
    • /
    • pp.29-34
    • /
    • 2021
  • Purpose Sample reception environment system in nuclear medicine has not changed much compared to 20 years ago. When preparing sample for in vitro test, there was no significant change because the test was carried out by generating an own specimen from the parent specimen. In this study, We would like to introduce a method that automatically removes the sample cap using the automated decapper equipment and enables automatic reception at the same time. In addition, including a provisional reception system. Materials and Methods In 2019, it was intended to get a device that automatically removes the cap of a patient's blood sample. This equipment is the same as the equipment used in the Department of Laboratory Medicine (Vacuette Ⓡ Unicap Belt Decapper, Greiner bio-one, Austria). However, the purchase was delayed due to differences in tube size, budget, and space. In January 2020, we borrowed domestic automatic decapper equipment and modified it to suit our laboratory environment. After 9 months, we were able to introduce a system that automatically removes the lid of a patient's blood sample and at the same time automatically accepts the test. And, through the provisional reception system, it was possible to know the arrival of the specimen in a short time. Results With the use of an automatic decapper device, the sample cap was automatically removed, and the reception proceeded at the same time. So, it was very efficient at work because it shortened the sample preparation time by about 20 minutes. In addition, it was possible to prevent the examiner's musculoskeletal disorders caused by repeated wrist use. After using the provisional reception system, patients were able to be discharged quickly, and the number of phone calls to confirm the arrival of samples was reduced. Conclusion Most hospitals have about four employees in the nuclear medicine in vitro laboratory. It is effective to use automatic decapper equipment and a provisional reception system for organizations that perform work with the minimum number of personnel.

Evaluation of Biocompatibility of Extracorporeal Circuit - Development of a Quantification Technique using in-vivo Injection of Tc99m Radioactive Platelets - (체외순환도관의 혈액적합성 평가 - 방사선 동위원소(Tc99m) 활성화 혈소판의 생체 내 주입을 이용한 정량분석법의 개발 -)

  • Lee, Sung-Ho;Sun, Kyung;Choi, Jai-Geol;Son, Ho-Sung;Jung, Jae-Seung;Ahn, Sang-Soo;Oh, Hye-Jung;Lee, Whan-Sung;Lee, Hye-Won;Kim, Kwang-Taik;Jeong, Yoon-Seop;Kim, Young-Ha;Kim, Hyoung-Mook
    • Journal of Chest Surgery
    • /
    • v.35 no.3
    • /
    • pp.171-176
    • /
    • 2002
  • Background: Blood-foreign interaction cause activation of coagulation and inflammatory process that may lead to multiorgan dysfunction and determine the surgical outcomes. Of the methods for assessing the biocompatibility, the platelet adhesion study is considered as the most valuable evaluation step in blood-foreign interaction. As the most studies have used in-vitro or ex-vivo conditions, we have developed a technique of quantification for platelet adhesion on the blood contact surface by using in-vivo injection of radioactive platelets. Material and Method: A coupled bypass circuit was designed to connect the proximal and descending thoracic aorta in 6 piglets(20∼25 Kg). One side of the circuit tube was consisted of a heparin coated PVC tube(10mm in ID, n=6, Experimental group), and the other, a non-heparin coated PVC tube(10mm in ID, n=6, Control group). After cannulation, the blood was circulated through the circuit for 2 hours. Platelet concentrate was prepared from homologous pig blood 24 hours before the experiment. The platelet concentrate was incubated with Tc-99m-HMPAO for 30 min and then centrifuged for 10 min. The supernatant was discarded and the radio-labeling efficacy was measured. The radio-labeled platelet concentrate was mixed with the autologous plasma to make the volume 5 ml, and the mixture was injected intravenously into the experimental animal. After 2 hour circulation, 5 pieces of the specimen(10mm in length each) were obtained from each PVC tube. The radioisotopes were counted with a gamma counter(Cobra ll, Packard, USA), and the ratio of radioisotope count was compared between the control and experimental group. Result: The radioisotope count number was 537.3221.1 Ci/min in the control group and 311.1 184.5 Ci/min in the experimental group(p=0.0104). The ratio between the groups was 1 to 0.58 (p=0.004). Conclusion: In vivo quantification using technetium-99m-HMPAO labeled platelets is simple and reproducible in evaluating platelet adhesion on a foreign surface. We suggest this technique to be a useful tool for blood compatibility test.

Effect of Magnetic Force on Rheological and Compressive Properties of Magneto-Rheological Rubber Composites with Iron Particle and Carbon Nanotubes (자기력이 철 분말 및 탄소나노튜브 강화 자기유동 고무 복합재료의 유동 및 압축 특성에 미치는 영향)

  • Ryu, Sang Ryeoul;Lee, Dong Joo
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.37 no.2
    • /
    • pp.153-160
    • /
    • 2013
  • An orthotropic magneto-rheological rubber composite (MRRC) based on a general-purpose rubber can be manufactured by using an electromagnetic device during the curing processes of rubber mixtures. The magnetic transmissivity of MRRCs increases with the iron particle (IP) content, and that of aligned MRRCs with a 2-T magnetic field is 1.8 to 2 times higher as compared to that of randomly dispersed MRRCs. The effect of a 2-T magnetic field on carbon nanotube (CNT) reinforced MRRC has been identified clearly, and the magnetic transmissivity is found to be 3.7%. The compressive stress of MRRC (IP 90 + CNT 5, 2 T alignment) under a magnetic field of 0.49 T is 2.1 times higher as compared to that of the matrix. The MR effect of MRRC increases with the IP content, and that of aligned MRRC with the IP 90 and 2 T magnetic field is 20.4%. It is confirmed that the magnetic field when making the specimen and when performing the compression test greatly impacts the compression characteristics.