• Title/Summary/Keyword: Tube Size

Search Result 813, Processing Time 0.029 seconds

Effect of High Tube Voltage and Scatter Ray Post-processing Software on Image Quality and Radiation Dose During Chest Anteroposterior Radiography (흉부 전·후방향 검사 시 고관전압 및 산란선 후처리 소프트웨어 적용이 화질과 선량에 미치는 영향)

  • Kim, Jong-Seok;Joo, Young-Cheol;Lee, Seung-Keun
    • Journal of radiological science and technology
    • /
    • v.44 no.4
    • /
    • pp.295-300
    • /
    • 2021
  • This study aims to present new chest AP examination exposure conditions through a study on the effect on image quality and patient dose by applying high tube voltage and scatter ray post-processing software during chest AP examination in digital radiography equipment. This study was used a human body phantom and in the chest AP position, the dosimeter was placed horizontally at the thoracic spine 6. The experiment was conducted by dividing into a low tube voltage (70 kVp, 400 mA, 3.2 mAs) group and a high tube voltage (100 kVp, 400 mA, 1.2 mAs) group. The collimation size (14″× 17″) and the source to image receptor distance(110 cm) were same applied to both groups. Radiation dose was presented to dose area product and entrance surface dose. Image quality was compared and analyzed by comparing the difference between the signal-to-noise ratio and the contrast-to-noise ratio of the image according to the application of the scatter ray post-processing software under each condition. The average value of the entrance surface dose in the low and high tube voltage conditions was 93.04±0.45 µGy and 94.25±1.51 µGy, which was slightly higher in the high tube voltage condition, but the dose area product was 0.97±0.04 µGy and 0.93±0.01 µGy. There was a statistically significant difference in the group mean value(p<0.01). In terms of image quality, the values of the signal-to-noise ratio and the contrast noise ratio were higher in the high tube voltage than in the low tube voltage, and decreased when the scattering line post-processing function was used, but the contrast resolution was improved. If there is a scatter ray post-processing function during chest AP examination, it is helpful to actively utilize it to improve the image quality. However, when this function is not available, I thought that applying a higher tube voltage state than a low tube voltage state will help to realize images with a large amount of information without changing the dose.

Visual Inspection of Tube Internal

  • Choi, Young-Soo;Cho, Jai-Wan;Kim, Chang-Hoi;Seo, Yong-Chil;Kim, Seung-Ho
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.789-792
    • /
    • 2003
  • Pipe inspection has a great importance to ensure safety for the nuclear power plant. In this paper, we designed visual inspection module for the tube internal, which diameter is 15${\sim}$20mm. And we made inspection module which consisted of CCD camera and light. And the relation between image and real world coordinate is established. Image processing is performed to calculate mapping parameter and analyze the size of defect. For the calculation of mapping parameter, experiment is performed using grid type test pattern. Acquired image is processed to extract image coordinate. Edge detection, thresholding, median filtering and morphology filtering is applied to extract grid pattern. Extracted image coordinate is used to calculate image to real world mapping. Lens distortion was considered and corrected to get exact data. Coordinate transformation data is provided for the users to recognize easily. Experiment was performed using grid type test pattern, we extracted lens distortion parameter and real coordinate of defect point. Radial distortion of lens was corrected but tangential distortion was not considered. As continuum to this study, the tangential distortion of lens is considered and improvement of analy zing technique for the tube internal be explored continuously.

  • PDF

Effects of GTAW Pulse Condition on Penetration, Discoloration and Bending Property for Titanium Tube (GTAW 펄스 용접 조건에 따른 타이타늄 정밀관의 용입, 변색 및 굽힘특성)

  • Min, Seonghwan;An, Sungyong;Park, Jitae;Park, Youngdo;Kang, Namhyun
    • Journal of Welding and Joining
    • /
    • v.32 no.6
    • /
    • pp.47-55
    • /
    • 2014
  • The purpose of the study is to produce a mechanically improved weld and minimum variation of color through comparing unpulsed and pulsed GTAW (Gas Tungsten Arc Welding) for pure titanium (CP grade7) tube. Pulsed GTAW using 60 A peak current and 20 A background current (1:9) achieved the wider window of welding conditions having part and full penetration without burn-through than the case of unpulsed GTAW. Moreover, the pulsed welding reduced a discoloration on the back bead of the weld and the size of microstructures (basket weave and serrated ${\alpha}$). That is because the pulsed welding has it's a low heat input and severe weld flow induced from electric current variation. Furthermore, the pulsed welding improved the bending property of the welded Ti tube. The enhanced bending property for the pulsed GTAW was due to the insignificant discoloration on the weld surface with maintaining the metal polish.

Design of High Frequency Resonant Inverter Type X-Ray Generator (고주파 공진형 인버터식 X선 발생장치의 설계)

  • Lee, Seong-Gil;Park, Su-Gang;Baek, Hyeong-Rae;Jeong, Su-Bok
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.51 no.1
    • /
    • pp.34-39
    • /
    • 2002
  • Most X-ray generator had been used do rectifier type transformer high tension generator which is supplied in a clinical diagnosis. But it is difficult to miniaturize and become light weight. Also, because the ripple rate of tube voltage is high, X-ray generating efficiency is very low. Therefore, it is supplied gradually from abroad being developed high tension generator for inverter type X-ray generator which use semi-conductor switching element for electric power that have high speed switching ability to solved these problem. But, semi-conductor element of big capacity are used by X-ray tube's big consumption power and diffusion is difficult in the small size hospital because production cost is ascending by doing digital control through DSP and product price becomes expensive. Therefore, in this paper, design and manufactured CR type voltage divider for feedback control of tube voltage of high frequency resonance type inverter and high tension transformer for high frequency to apply economical diffusion type X-ray generator which have wide output voltage and load extent. It is Proved do X-ray generator and stability of X-ray tube's output characteristics through an experiment.

STEAM DRUM DESIGN FOR A HRSG BASED ON CFD (수치해석을 이용한 HRSG(Heat Recovery Steam Generator) 증기 드럼 설계)

  • Ahn, J.;Lee, Y.S.;Kim, J.J.
    • Journal of computational fluids engineering
    • /
    • v.16 no.1
    • /
    • pp.67-72
    • /
    • 2011
  • HRSG (Heat Recovery Steam Generator) is a boiler to recover heat from the exhaust gas of an engine and to generate steam for more power generation or process. For the HRSG, water-tube type boiler is commonly adopted to accommodate the working pressure or capacity requirement of the system. The water-tube type boiler has a steam drum to separate steam from the water-steam mixture supplied from the evaporator tube (riser). The drum should be sized properly to separate the steam by the gravity and auxiliary internals, such as a demister, which are installed to filter the steam. To size the steam drum and to estimate the filter efficiency of drum internals, the velocity distribution inside the drum needs to be identified. In the present study, a series of CFD has been conducted to find the velocity distributions inside steam drums for conventional HRSGs and water-tube type industrial boilers. The velocity distributions obtained from the simulation have been normalized and a correlation to predict them has been found. The correlation is applied to the steam drum design by determining a proper position of a demister to show proper separation performance.

Process Analysis and Die Design for Al3003 Condenser Tube Extrusion with 12 Cell (Al3003 12셀 컨덴서 튜브의 압출을 위한 공정해석 및 금형설계)

  • Lee, Sang-Ho;Lee, Jung-Min;Jo, Hyung-Ho;Jo, Hoon;Kim, Mun-Bae;Kim, Byung-Min
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.24 no.11
    • /
    • pp.44-51
    • /
    • 2007
  • Condenser tubes are mainly produced by precision extrusion with a porthole die and are used in the flow pass of refrigerant cooling systems in automobiles. The recent technical trend of condenser tube requires the tube to be of more multi cellizing, high strength and small size, and to increase the heat transfer area and heat efficiency. Hence, this paper is shown that the results of FE-simulation are in good agreement with the experimental ones. Finally, the extrusion die shape is proposed through analysis of FE-simulation and performance of trial extrusion. Chamber shape dimension and initial temperatures of die is adjusted analysis results. And the possibility of extrusion is estimated that forming load, welding pressure and stress analysis of die in this paper. The validity of simulated results was verified into extrusion experiments on the condenser tubes.

Capacity of Concrete Filled Carbon Tube Columns Based on the Comparison of Ductility and Energy Dissipation Capacity (연성도 및 에너지 소산능력 비교에 따른 콘크리트충전 탄소섬유튜브 기둥의 성능)

  • Lee, Kyoung-Hun;Hong, Won-Kee;Lee, Young-Hak;Kim, Hee-Cheul
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.11 no.1 s.53
    • /
    • pp.29-35
    • /
    • 2007
  • Flexural capacity estimation test of concrete filled carbon tube (CFCT) column under the cyclic lateral load was carried out in this study. Thickness of carbon tube and winding angles of carbon fiber were chosen as test parameters and two types of column with square and circular sections were manufactured. To act axial and lateral load, three dynamic actuators were used and all specimens were made with actual size. Flexural stiffness, ability of deformation, energy dissipation capacity and ductility behavior. of CFCT column were analyzed with test data.

Finite Element Method Analysis of Eddy Current Array Probe According to Defects Variation of Steam Generator (배열와전류프로브를 이용한 증기발생기 세관의 결함 변화에 따른 유한요소해석)

  • Kim, Ji-Ho;Lee, Hyang-Beom
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2009.08a
    • /
    • pp.54-58
    • /
    • 2009
  • In this paper, the ECT(eddy current testing) signal analysis of eddy current array probe for inspection of SG(steam generator) tube in NPP(nuclear power plant) using electromagnetic FEM(finite element method) was performed. To obtain the electromagnetic characteristics of probes, the governing equation was derived from Maxwell's equation, and the problem was solved by using the 3-dimensional FEM. The types of defects were FBH(flat bottomed hole) and OD groove, Spiral groove, natural defects(pitting, SCC, multiple SCC, wear). The depth of FBH defects were 20%, 40%, 60%, 80%, 100 of SG tube thickness, and it was assumed that the defects were located on the tube outside. And the operation frequency of 100kHz, 300kHz and 400kHz were used. Material of specimen was Inconel 600 which is usually used for SG tubes in NPP. The signal difference could be observed according to the variation of size and depth on FBH defects and operation frequencies. The results in this paper can be helpful when the ECT signals from EC array probe are evaluated and analyzed.

  • PDF

A Study on the Improvement of ripple factor tube voltage waveforms in inverter type X-ray generator (인버터식 X선장치의 관전압 맥동율 개선에 관한 연구)

  • 이성길;임홍우;조금배;정수복;백형래
    • Proceedings of the KIPE Conference
    • /
    • 1999.07a
    • /
    • pp.234-238
    • /
    • 1999
  • In order to radiate X-ray, the low ripple stabilized high voltage DC over the range of 40KV to 150KV is directly inflicted to X-ray tube. The energy characteristics of the radiated X-ray depend on the pulsating waveforms of the DC voltage supplied X-ray tube. In general, the low ripple voltage waveforms with fast rising times are required to increase with the dosage per unit time lest the exposure time should be longer in orde that the motion artifacts of an object may be eliminated in actual. The conventional types of X-ray generators were bulky in physical size and heavy in weight, and the control accuracies of the output voltages were not always satisfactory. The high frequency switching inverter and converter technology on power conversion and control systems have been greatly closed up introducing new power semiconductor devices. To decreasing the volume and the weight of high voltage transformer, and to stabilize ripple, a high frequency PWM inverter is connected between DC source and high voltage transformer. This paper describes the output characteristics according to stabilize ripple of X-ray tube voltage and compared the reproducibility, direcibility and doesage.

  • PDF

A Comparative Study on the Clamping Protocols of a Biliary External Drainage Tube in Adult Living-donor Liver Transplant Recipients (성인 생체 간이식 수혜자에서 담도 외-배액관 잠그기 훈련 방법 비교)

  • Chung, Jin Ah;Choi, Hye Ran
    • Journal of Korean Critical Care Nursing
    • /
    • v.7 no.1
    • /
    • pp.33-39
    • /
    • 2014
  • Purpose: The propose of this study was to introduce the clamping protocols for a biliary external drainage tube and trace the results of using clamping protocols to prevent some possible biliary complications or enable their early detection in living-donor liver transplantation. Method: This study was a retrospective study to analyze the cases of 97 subjects who had undergone liver transplantation in a hospital in Seoul, Korea. Clamping protocol 1 was applied to 47 patients, and clamping protocol 2 was applied to 50 patients. Results: In the case of protocol 1, the success rate of the clamping protocol was 74.5%, while that of protocol 2 was 84.0%. However, there was no significant difference in the compiled statistics from authentic sources (p = .246). Conclusions: The difference in the success rate between the two protocols was not significant for the clamping protocols of the biliary external drainage tube. However protocol 2 is suggested for the clamping method due to the simplicity of application. Further study with a large sample size is suggested.

  • PDF