• 제목/요약/키워드: Tube Plate

검색결과 498건 처리시간 0.027초

가정용 냉장고의 응축기 비용저감을 위한 판형 핀-관 열교환기의 열전달 특성 (Heat Transfer Characteristics of Cost Effective Plate Fin-tube Condenser for Household Refrigerator)

  • 손영우;이장호
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.323-327
    • /
    • 2008
  • 본 연구는 판형 핀-관 열교환기의 열전달 특성을 상용 CFD 코드인 SC/Tetra를 사용하여 해석한 내용에 관한 것이다. 해석조건은 입구속도 0.63 m/s, 튜브온도 $44.5^{\circ}C$이다. 해석 열교환기는 총6가지로 검토하였으며 각각의 온도분포와 유동패턴을 해석하고 판형 핀-관 열교환기의 열전달 특성을 비교 검토하였다.

  • PDF

Quasi-monochromatic Parallel Radiography Achieved with a Polycapillary Plate

  • Sato, Eiichi;Komatsu, Makoto;Hayasi, Yasuomi;Tanaka, Etsuro;Mori, Hidezo;Kawai, Toshiaki;Ichimaru, Toshio;Takayama, Kazuyoshi;Ido, Hideaki
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.418-421
    • /
    • 2002
  • Fundamental study on quasi-monochromatic parallel radiography using a polycapillary plate and a plane-focus x-ray tube is described. The x-ray generator consists of a negative high-voltage power supply, a filament (hot cathode) power supply, and an x-ray tube. The negative high-voltage is applied to the cathode electrode, and the transmission type target (anode) is connected to the ground potential. The maximum voltage and current of the power supply were -100 kV (peak value) and 3.0 mA, respectively. In this experiment, the tube voltage was regulated from 20 to 25 kV, and the tube current was regulated by the filament temperature and ranged from 1.0 to 3.0 mA. The exposure time is controlled in order to obtain optimum film density, and the focal spot diameter was about 10 mm. The polycapillary plate is J5022-21 made by Hamamatsu Photonics Inc., and the outside and effective diameters are 87 and 77 mm, respectively. The thickness and the hole diameter of the polycapillary are 1.0 mm and 25 ${\mu}$m, respectively. The x-rays from the tube are formed into parallel beam by the polycapillary, and the radiogram is taken using an industrial x-ray film of Fuji IX 100 without using a screen. In the measurement of image resolution, we employed three brass spacers of 2, 30, and 60 mm in height. By the test chart, the resolution fell according to increases in the spacer height without using a polycapillary. In contrast, the resolution slightly fell with corresponding increases in the height by the polycapillary. In angiography, fine blood vessels of about 100 ${\mu}$m are clearly visible.

  • PDF

튜브 지지판 재배치에 따른 유체유발진동 특성 해석 (FIV Analysis of SG Tubes for Various TSP Locations)

  • 김형진;박치용;박명호;유기완
    • 한국소음진동공학회논문집
    • /
    • 제15권9호
    • /
    • pp.1009-1015
    • /
    • 2005
  • Fluid-elastic instability and turbulence excitation for an under developing steam generator are investigated numerically. The stability ratio and the amplitude of turbulence excitation are obtained by using the $PIAT^{(R)}$ (program for integrity assessment of steam generator tube) code from the information on the thermal-hydraulic data of the steam generator. The aspect ratio, the ratio between the height of U-tube from the upper most tube support Plate (h) and the width of two vertical portion of U-tube (w), is defined for geometric parameter study. Several aspect ratios with relocation of tube support plates are adopted to study the effects on the mode shapes and characteristics of flow-induced vibration. When the aspect ratio exceeds value of 1, most of the mode shapes at low frequency are generated at the top of U-tube. It makes very high value of the stability ratio and the amplitude of turbulent excitation as well. We can consider that the local mode shape at the upper side of U-tube will develop the wear phenomena between the tube and the anti-nitration bars such as vortical, horizontal, and diagonal strips. It turns out that the aspect ratio reveals very important parameter for the design stage of the steam generator. The appropriate value of the aspect ratio should be specified and applied.

원통형 임피던스 튜브 내 미세천공 탄성 판의 흡음 (Sound absorption of micro-perforated elastic plates in a cylindrical impedance tube)

  • 김현실;김봉기;김상렬;이성현;마평식
    • 한국음향학회지
    • /
    • 제37권4호
    • /
    • pp.181-187
    • /
    • 2018
  • 본 논문은 원형 단면 임피던스 튜브내에 고정된 미세천공 탄성판의 흡음을 해석적으로 구하는 방법을 다루었다. 판의 진동과 덕트 내부 음장을 모드 함수의 무한 급수의 합으로 전개하였는데 반경방향으로는 Bessel 함수를 포함한다. 평면파 가정하에서 저주파수 대역의 근사식을 판의 처음 몇 개의 모드만 고려하여 흡음율을 유도하였으며 등가 임피던스를 갖는 단일 표면의 형태로 제시하였다. 본 논문에서 제안한 공식과 FEM(Finite Element Method)을 이용한 결과는 잘 일치 하였는데 탄성의 효과는 판의 고유진동수에 해당하는 골 또는 피크의 형태로 나타난다. 천공율이 매우 작으면 진동의 영향이 지배적이나 천공율이 어느 한계이상 되면 박판의 탄성거동은 매우 작게 나타나고 강체 MPP(Micro-Perforated Plate)의 흡음 특성이 지배적이 된다.

약한 충격파의 반사와 방출에 관한 개구단 보정 (Open End Correction for the Reflection and Discharge of Weak Shock Wave)

  • 이동희;김희동;뢰호구후명
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집E
    • /
    • pp.349-354
    • /
    • 2001
  • The present study addresses the open end correction associated with the reflection and discharge phenomena of a weak shock wave from an open end of a duct. The open end correction of the weak shock wave is investigated experimentally and by numerical computation. An experiment is made using a simple shock tube with an open end, and computation is performed to simulate the experimental flow field using the unsteady, axisymmetric, compressible, flow governing equations. The results obtained show that an open end correction should be involved for shock wave discharge and reflection problems generated from the exit of the duct with an open end baffle plate. With a baffle plate less than three times the duct diameter, it is found that the open end correction is a function of both the diameter of the baffle plate and normal shock wave magnitude. However, for a baffle plate larger than three times the duct diameter, it is independent of the baffle plate diameter. The present computations predict the results of shock tube experiment with good accuracy. A new empirical equation for prediction of the open end correction is found for the weak shock reflection and discharge phenomena occurring at the open end of the duct with and without a baffle plate.

  • PDF

관출구로부터 방출하는 펄스파의 개구단 보정에 관한 연구 (Study of the Open End Correction of the Impulsive Wave Discharging from a Duct Exit)

  • 이동훈;김희동
    • 한국소음진동공학회논문집
    • /
    • 제11권7호
    • /
    • pp.239-246
    • /
    • 2001
  • The present study addresses the open correction associated with the reflection and discharge phenomena of a weak shock wave from an open end of a duct. The open correction of the weak shock wave is investigated experimentally and by numerical computation. An experiment is made using a simple shock tube with an open end. and computaion is performed to simulate the experimental flow field using the unsteady, axisymmetric compressible. flow governing equations. The results obtained show the an open correction should be involved for shock wave discharge and reflection problems generated from the exit of the duct with an open baffle plate. With a baffle plate less than three times the duct diameter, it is found that the open end correction is a function of both the diameter of the baffle plate and normal shock wave magnitude However, for a baffle plate larger than three the duct diameter it is independent of the baffle plate diametre, The present computations predict the results of shock tube experiment with good accuracy. A new empirical equation for prediction of the open correction is found for the weak shock reflection and discharge phenomena occurring at the open of the duct with and without a baffle plate.

  • PDF

Analytical solution for buckling analysis of micro sandwich hollow circular plate

  • Mousavi, Mohammad;Mohammadimehr, Mehdi;Rostami, Rasoul
    • Computers and Concrete
    • /
    • 제24권3호
    • /
    • pp.185-192
    • /
    • 2019
  • In this paper, the buckling of micro sandwich hollow circular plate is investigated with the consideration of the porous core and piezoelectric layer reinforced by functionally graded (FG)carbon nano-tube. For modeling the displacement field of sandwich hollow circular plate, the high-order shear deformation theory (HSDT) of plate and modified couple stress theory (MCST) are used. The governing differential equations of the system can be derived using the principle of minimum potential energy and Maxwell's equation that for solving these equations, the Ritz method is employed. The results of this research indicate the influence of various parameters such as porous coefficients, small length scale parameter, distribution of carbon nano-tube in piezoelectric layers and temperature on critical buckling load. The purpose of this research is to show the effect of physical parameters on the critical buckling load of micro sandwich plate and then optimize these parameters to design structures with the best efficiency. The results of this research can be used for optimization of micro-structures and manufacturing different structure in aircraft and aerospace.

Tube Dilution Technique과 Ager Plate Smear Method에 의한 키토산의 MPSA 항미생물성 (A Study on the Antimicrobial Activity of Chitosan on the MRSA by Tube Dilution Technique and Agar Plate Smear Method)

  • 최정임;전동원
    • 한국의류산업학회지
    • /
    • 제5권1호
    • /
    • pp.71-76
    • /
    • 2003
  • Three different types of chitosan were prepared from red crab shells to study anti-microbial activity of chitosan on pathogenic bacteria, MRSA(Methicillin-resistant. Staphylococcus aureus), Water-insoluble chitosan, whose degree of deacetylation is kept over 90% and molecular weights are 20,000, 500,000, 150,000, 80,000, and 40,000, respectively. Water-soluble chitosan, whose degree of deacetylation is about 48% and molecular weights are 200,000 and 80,000. Water-soluble chitosan, whose degree of deacetylation is 82% and molecular weight is 3,900. The anti-microbial activities of three types of chitosan were investigated by Tube Dilution Technique(TDT) and Agar Plate Smear Method(APSM). And the following conclusions are made ; Chitosan having 5 different types of M.W chitosan (over 90% deacetylation) showed similar anti-microbial activities at over 0.05% concentration. Especially, chitosan having M.W 40,000 150,000 showed the excellent anti-microbial activity. The anti-microbial activity of chitosan was enhanced when the chitosan/acetic add solution was aged for 7days. The anti-microbial activity of chitosan was only shown at chitosan/acetic acid solution. The anti-microbial activity was not detected in chitosan solution dissolved in neutral pH water. Therefore, it can be concluded that the anti-microbial activity was due to NH3+ cationic ion of chitosan in acidic aqueous solution.

수평하중을 받는 튜브 구조물의 플랜지에 작용하는 부가 응력 (Additional Stresses in Flange Frame of Tube Structures under Lateral Loading)

  • 이강건;이리형
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2001년도 봄 학술발표회 논문집
    • /
    • pp.317-322
    • /
    • 2001
  • A mathematical modelling technique is proposed for estimating the additional bending stresses of tube(s)-in-tube structures due to tube-tube interaction, which has a significant effects on the shear-lag phenomenon. The proposed method simulates the framed-tube structures with multiple internal tubes as equivalent multiple tubes, each composed of four equivalent orthotropic plate panels. Hence, the tube(s)-in-tube structure can be analysed by using an analogy approach where each tube is individually modelled by a continuous beam that can account for the flexural and shear deformations as well as the shear-lag effects. The numerical analysis is applicable for the structural analysis of framed-tube structures with single and multiple internal tubes, as well as those without internal tubes. The shear-lag phenomenon of such structures is studied with additiona] bending stresses and shear-lag reversal points.

  • PDF