• 제목/요약/키워드: Tube Plate

검색결과 498건 처리시간 0.027초

다층 다단 다공성 플레이트 시스템의 집진 특성 (Collection Characteristics of Multi-layer Multi-stage Porous Plate System)

  • 김일규;여석준
    • 동력기계공학회지
    • /
    • 제14권5호
    • /
    • pp.10-16
    • /
    • 2010
  • The main object of this study is to investigate the collection characteristics of multi-layer multi-stage porous plate system experimentally. The experiment is carried out to analyze the characteristics of pressure drop and collection efficiency for the present system with the experimental parameters such as inlet velocity, tube diameter, inlet concentration, and stage number, etc. In results, the pressure drop becomes 22 to $115mmH_2O$ with increment of stage number (1 to 5) of porous plate system at tube velocity 15 m/s and tube diameter ${\Phi}8$. In case of fly ash and 5 stage, the collection efficiency becomes 90.5 to 95.7% increasing the tube velocity 12 to 15 m/s at inlet concentration $3g/m^3$ and tube diameter ${\Phi}8$. Additionally, it is estimated that the collection efficiencies of 5 stage are 94.3, 95.6 and 99.1% for fly ash, steel dust and based power, respectively (${\Phi}8$ tube, $V_t$ = 12m/s, inlet concentration $3g/m^3$).

고속 Tube Expander의 동적 모델링 및 해석 (Analysis and Dynamic Modeling of a High-speed Tube Expander)

  • 김재량;정원지;김수태;최욱환
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2003년도 추계학술대회
    • /
    • pp.401-411
    • /
    • 2003
  • Tube expanding process is for combining a heat-sink plate with hair-pins (Cu-tube) through plastic deformation. The two parts, i. e. , heat-sink plate and hair-pins are they components of a heat-exchanger for an air conditioner. This paper presents the analysis and dynamic modeling of a high-speed tube expander which integrates transfer of parts, fixing of parts, and tube expanding into one process. The 3-dimensional modeling of all the parts for the tube-expander was constructed using CATIA$\circledR$. then the CATIA$\circledR$ models are transferred into visuaINastran$\circledR$ to execute the 3-dimensional animation for checking prescribed cycle-time. The technique presented in this paper has been shown to be effective as a priori tool for verifying the design of a high-speed tube expander.

  • PDF

Comparison of Absolute and Differential ECT Signals around Tube Support Plate in Steam Generator

  • Shin, Young-Kil;Lee, Yun-Tai;Song, Myung-Ho
    • 비파괴검사학회지
    • /
    • 제25권3호
    • /
    • pp.201-208
    • /
    • 2005
  • In this paper, absolute and differential eddy current signals from various defects in the steam generator tube are numerically predicted and their signal slope characteristics are investigated. The signal changes due to frequency increase are also observed. After studying signal patterns from various defects and frequencies, the analysis of mixed defect signals affected by the presence of a ferromagnetic support plate is attempted. For the signal prediction, axisymmetric finite element modeling is used and this leads us to the slope angle analysis of the signal. Results show that differential signals are useful for locating the position of a defect under the support plate, while absolute signals are easy to presume and interpret even though the effect of support plate is mixed. Combined use of these two types of signals will help us accomplish a more reliable inspection.

공동주택의 태양열 집열기 효율에 대한 실험적 연구 (An Experimental Study on the Solar Collector Efficiency for Apartment Building)

  • 최병도;김미연
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2011년도 추계학술대회 초록집
    • /
    • pp.130.2-130.2
    • /
    • 2011
  • The application of solar energy in residential building is general and natural in today. And application methods of solar thermal energy is divided in two kind of form, single evacuated tube and flat-plate form. Then in this study, the efficiency of single evacuated tube and flat-plate system is compared by total and effective area considering the time receiving the solar radiation between 24 hours and the specific time(10:00~15:00). As a result of the experiment, single evacuated tube and flat-plate collector's efficiency is varied by the quantity of solar radiation. And especially, the flat-plate system is more affected by outdoor temperature. Therefore the application of solar thermal system should be considered the solar radiation and outdoor temperature.

  • PDF

Lateral performance of CRCS connections with tube plate

  • Jafari, Rahman;Attari, Nader K.A.;Nikkhoo, Ali;Alizadeh, Saeid
    • Steel and Composite Structures
    • /
    • 제32권1호
    • /
    • pp.37-57
    • /
    • 2019
  • This paper presents experimental and analytical studies to evaluate the cyclic behaviour of Circular Reinforced Concrete column Steel beam (CRCS) connections. Two 3/4-scale CRCS specimens are tested under quasi-static reversed cyclic loading. Specimens were strengthened with a tube plate (TP) and a steel doubler plate (SDP). Furthermore; nine interior beam-through type RCS connections are simulated using nonlinear three-dimensional finite element method using ABAQUS software and are verified with experimental results. The results revealed that using the TP improves the performance of the panel zone by providing better confinement to the concrete. Utilizing the TP at the panel zone may absorb and distribute stress in this region. Results demonstrate that TP can be used instead of SDP. Test records indicate that specimens with TP, with and without SDP maintained their maximum strength up to 4% drift angle, satisfying the recommendation given by AISC341-2016 for composite special moment-resisting frames.

나선형 핀-튜브 증발기를 적용한 냉장고의 성능 특성에 관한 연구 (Study on Performance Characteristics of Spiral Fin-Tube Evaporator Applied to Domestic Refrigerator-Freezers)

  • 이상헌;윤원재;김용찬;이무연;윤성중
    • 대한기계학회논문집B
    • /
    • 제37권3호
    • /
    • pp.205-212
    • /
    • 2013
  • 본 연구는 평판 핀-튜브 증발기와 나선형 핀-튜브 증발기를 적용한 가정용 냉장고의 성능특성 비교를 통하여 기존에 사용하고 있는 핀-튜브 증발기를 나선형 핀-튜브 증발기로 대체할 수 있는 가능성을 고찰하는데 그 목적이 있다. 실험은 2단 15열의 평판 핀-튜브 증발기와 2단 15열에서 2단 11열까지 열 수를 단계적으로 감소시킨 3종류의 나선형 핀-튜브 증발기를 실제 냉장고에 적용하여 수행하였다. 핀-튜브 증발기의 열 수가 감소할수록 냉동시스템의 최적 냉매 충전량은 감소하였으며, 2단 13열과 2단 11열의 나선형 핀-튜브 증발기를 장착한 냉장고의 소비전력은 기존 2단 15열의 평판 핀-튜브 증발기를 적용한 냉장고 대비 각각 1.5%와 2.8% 감소하였다. 또한 내착상 실험결과 나선형 핀-튜브 증발기가 기존 평판 핀-튜브 증발기와 비교하여 같은 착상조건에서 3~7% 향상된 냉각능력을 보였다. 냉각속도 실험에서는 모든 증발기는 동등수준의 성능을 나타내었다.

OPR 1000 증기발생기 전열관의 ODSCC 고찰 (A Study on ODSCC of OPR 1000 Steam Generator Tube)

  • 석동화;오창하;이재욱
    • 한국압력기기공학회 논문집
    • /
    • 제6권2호
    • /
    • pp.16-19
    • /
    • 2010
  • In this study, the axial ODSCC occurrence of domestic OPR 1000 steam generator tube was caused by the tube weakness and the sludge accumulation in the secondary side of steam generator. Inconel 600 HTMA used as tube material is related to most of tube leakage accidents in the world and also these ODSCCs were detected mainly at the 5th TSP(Tube Support Plate) to the 8th TSP of hot leg side. These elevations(5th TSP to 8th TSP) pave the way for the sludge accumulation. As a result of EC(Eddy Current) Bobbin and RPC data analysis, ODSCCs were occurred at contact points of tube and tube support plate. The more accumulated sludge, the higher occurrence frequency of ODSCC.

  • PDF

SERO-EPIDEMIOLOGICAL STUDY OF BRUCELLOSIS AMONG GOATS AND SHEEP AT PESHAWAR DISTRICT

  • Ghani, M.;Siraj, M.;Zeb, A.;Naeem, M.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제8권5호
    • /
    • pp.489-494
    • /
    • 1995
  • Sero-epidemiological study was carried out to observe the prevalence of brucellosis in 500 slaughtered as well as in 500 healthy animals in Peshawar district of N.W.F.P. All serum samples were subjected to four serological tests i.e. Standard Plate Test (SPT), Standard Tube Test (STT), Rivanol Test (RV) and 2, Mercapto-Ethanol Test (2, ME). The incidence of disease in 500 healthy animals tested by standard plate test, standard tube test, rivanol test and 2, Mercapto-ethanol test, was 2.8%, 1.8%, 1.6% and 1.2% respectively. While the incidence of brucellosis in 500 slaughter animals from Peshawar abattoir was 3.0%, 2.2%, 2.00% and 1.2% by standard plate test, standard tube test, rivanol test and 2, Mercapto-ethanol test The disease prevalence was higher in slaughtered animals as compared to healthy animals. The disease was more common in goats than sheep, also more prevalence in aged female than younger stocks. The efficacy of SPT was found more effective as compared to STT, RV, and 2, ME tests both in slaughtered as well as apparently healthy animals at Peshawar district. Standard Plate test detected 2.9%, Standard Tube test 2.0%, Rivanol test 1.8% and 2, Mercapto-ethanol test detected 1.2% positive cases in slaughtered as well as in healthy animals. So the Standard Plate Test was found to be more reliable, sensitive, and easy to performed.

Delta Wing Vortex Generator가 부착된 Plate Fin-Oval Tube 열교환기에서 휜 주위의 유동에 대한 수치적 해석 (The Numerical Analysis of the Flow Fields near Fin Surface of a Plate Fin-Oval Tube Heat Exchanger with Delta Wing Vortex Generators)

  • 신석원;정인기;김수연;이영우
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회B
    • /
    • pp.2023-2028
    • /
    • 2008
  • In present study, the flow field near the fin surface of plate fin - oval tube heat exchanger with delta wing vortex generator was numerically analyzed. As results, the well developed vortex behind delta wing was observed. These vortex can improve heat transfer fin surface behind delta wing vortex generators.

  • PDF