• Title/Summary/Keyword: Tube Line

검색결과 366건 처리시간 0.029초

Vortex-induced vibration characteristics of multi-mode and spanwise waveform about flexible pipe subject to shear flow

  • Bao, Jian;Chen, Zheng-Shou
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • 제13권1호
    • /
    • pp.163-177
    • /
    • 2021
  • Numerical simulations of the Vortex-Induced Vibration (VIV) about a large-scale flexible pipe subject to shear flow were carried out in this paper. Efficiency verification was performed firstly, validating that the proposed fluid-structure interaction solution strategy is competent in predicting the VIV response. Then, the VIV characteristics related to multi-mode and spanwise hybrid waveform about the flexible pipe attributed to shear flow were investigated. When inflow velocity rises, higher vibration modes are apt to be excited, and the spanwise waveform easily convertes from a standing-wave-dominated status to a hybrid standing-traveling wave status. The multi-mode or even multiple-dominant-mode is prone to occur, that is, the dominant mode is often followed by several apparent subordinate modes with considerable vibration energy. Hence, the shedding frequencies no longer obey Strouhal law, and vibration trajectories become intricate. According to the motion analysis concerning the coupled cross-flow and in-line vibrations, as well as the corresponding wake patterns, a tight coupling interaction exists between the structural deformation and the wake flow behind the flexible pipe. In addition, the evolution of the vortex tube along the pipe span and a strong 3D effect are observed due to the slenderness of the flexible pipe and the variability of the vortex shedding attributed to the shear flow.

판형쉘열교환기 기본설계를 위한 경향성 분석 (Trend Analysis for Basic Design of a Plate and Shell Heat Exchanger)

  • 최동현;장윤석;강선예
    • 한국압력기기공학회 논문집
    • /
    • 제18권2호
    • /
    • pp.69-76
    • /
    • 2022
  • In order to prepare for a future nuclear market, research for developing floating small modular reactor has been initiated with the aim of differentiating it from large nuclear power plants such as distributed power, heat supply to remote communities and sea water desalination. Depending on the characteristics of the small modular reactor, it is necessary to design a plate and shell heat exchanger that can be manufactured smaller than the U-tube recirculation method. In this study, 12 cases are selected by changing the diameter of the heat plate, the thickness of the device body and the size of the stiffener. Finite element analysis is performed by setting the stress classification lines for the point at which deformation is expected under external pressure conditions for these analysis cases. For the basic design of the plate and shell heat exchanger, the optimal conditions are derived by analyzing the tendency of stress change in the device body and stiffener.

동작 모니터링 스마트 의류를 위한 직물 센서의 성능 평가: 더미 실험을 중심으로 (Performance Evaluation of Fabric Sensors for Movement-monitoring Smart Clothing: Based on the Experiment on a Dummy)

  • 조현승;박선형;강다혜;이강휘;강승진;한보람;오정훈;이해동;이주현;이정환
    • 감성과학
    • /
    • 제18권4호
    • /
    • pp.25-34
    • /
    • 2015
  • 본 연구에서는 전도성 직물을 기반으로 동작 센서로 구현하여 팔의 굽힘, 폄 동작에 따른 센서의 전기저항의 변화를 측정, 분석함으로써 관절 동작을 효과적으로 측정 할 수 있는 직물 센서의 요건을 탐색하였다. 이를 위해 두 가지 편직물인 'L'직물과 'W'직물 양면에 Single Wall Carbon Nano-Tube(SWCNT) 코팅을 한 후 이를 다양한 형태로 후가공하여 직물 센서를 개발하고 암 밴드에 부착하였다. 직물 센서는 코팅용 바탕 직물의 종류(2가지), 센서의 부착 방법(2가지), 센서의 layer 수(2가지), 센서의 길이(3가지), 센서의 너비(2가지)의 총 48개로 구성되었다. Con-Trex MJ에 48개의 암 밴드를 입힌 인체 모형 팔을 대상으로 직물 동작 센서의 성능을 평가하였다. 인체 모형 팔에 입혀진 총 48개의 암 밴드 각각에 대해서 frequency: 0.5Hz, ROM: $20^{\circ}{\sim}120^{\circ}$ 에서 굽힘과 폄 동작을 반복하도록 조정하였고, 48개 각 사례 당 세 세트(set)씩 반복 측정한 전압값을 기록하였다. 전압값을 peak-to-peak voltage(Vp-p)의 base line의 균일성, 동일 세트 내 Vp-p의 균일성, 세 세트 간의 Vp-p의 균일성을 기준으로 평가하고 분석한 결과, SWCNT 코팅된 'L' 직물을 두 겹으로 구성하여 열고정 방식으로 부착한 $50{\times}5mm$, $50{\times}10mm$, $100{\times}10mm$ 크기의 직물 센서와, SWCNT 코팅된 'W' 직물을 두 겹으로 구성하고 열고정 방식으로 부착한 $50{\times}10mm$ 크기의 직물 센서가 전체 변화율 5%이내의 가장 균일하고 안정적인 신호값을 나타내었다. 이상의 연구 결과를 통해 SWCNT 코팅 소재를 다양한 형태로 가공해 직물 센서로 구현했을 때 인체의 사지 동작을 측정할 수 있는 센서로서 적합함을 확인하였고, 최적의 센서 형태를 규명하였다.

덴탈유니트의 핸드피스 및 초음파 치석 제거기의 미생물 오염에 관한 연구 (A STUDY ON THE MICROBIAL CONTAMINATION OF DENTAL UNIT AND ULTRASONIC SCALER)

  • 이병문;김창회;김영수
    • 대한치과보철학회지
    • /
    • 제36권1호
    • /
    • pp.64-80
    • /
    • 1998
  • The risk of cross-contamination in dental clinic is very high. Those who are engaged in dental clinic are exposed to various microorganisms in saliva and blood of patient. Potential possibility of cross-contamination of patient to patient, patient to dentist, dentist to laboratory technician always exist, which is important in the view of public health. It is well known that microorganisms may cause cross-contamination by suck-back of microorganisms into the water supply line or air supply line of dental unit and sprayed back into the next patient's oral cavity. The majority of microorganisms coming from dental unit are water microorganisms from the main water supply which have colonized the tube within the units and multiplied in the relatively warm and stagnant conditions. The purpose of this study is to measure the extent of microbial contamination of dental unit and ultrasonic scaler, to evaluate that dental unit water supply is suitable for drinking water, and to assess the effect of flushing on reduction of microbial contamination of dental unit and ultrasonic scaler. In the first experiment, water samples(50ml) from 20 dental units and 10 ultrasonic scalers in Seoul National Univ. Hosp. were tested for the presence of coliform. The samples were filtered by membrane filtration technique.(Microfil system, Millipore Co. U. S. A.) The filter was then placed onto MacConkey agar plate and the plates with filter on it were incubated aerobically at $37^{\circ}C$ for 5 days. The colors and shapes of colonies were examined if those were coliform. To verify the presence of coliform, the colonies were inoculated into phenol red lactose broth and incubated aerobically at $37^{\circ}C$ for 2 days. The fomation of gas was observed. In the second experiment, water samples from 20 handpieces, 10 ultrasonic scalers and 30 A/W syringes after 0, 2, 4, 6 min. flushing respectively were taken. $200{\mu}l$ water samples were spreaded on Brain Heart Infusion agar plate and the plates were incubated aerobically at $37^{\circ}C$ for 5 days. The number of colony was counted. The results obtained were summarized as follows 1. The water from dental unit and ultrasonic scaler was not suitable for drinking water. 2. No coliform was founded in dental unit and ultrasonic scaler water supply. 3. The number of colony of dental unit and ultrasonic scaler was highest in the group of o min. flushing(p<0.05). 4. There was no statistically significant difference in the extent of microbial contamination among handpiece, ultrasonic scaler and A/W syringe (p>0.05). 5. The number of colony was lowest in the group of 4 min. flushing, but there was no statistically significant difference among 2, 4, 6 min. flushing groups.(p>0.05) 6. It is recommended to flush dental unit water line for 4 min. after use on each patient.

  • PDF

외상 환자에 대한 바늘감압술에서 흉벽 두께와 바늘 길이의 관계 (Needle Decompression for Trauma Patients: Chest Wall Thickness and Size of the Needle)

  • 김지완;정진우;조석주;염석란;한상균;박성욱
    • Journal of Trauma and Injury
    • /
    • 제23권2호
    • /
    • pp.63-67
    • /
    • 2010
  • Purpose: A tension pneumothorax is a fatal condition that requires immediate intervention. Although a definitive treatment for a tension pneumothorax is a tube thoracostomy, needle decompression can provide temporary relief, that is lifesaving. The traditional procedure for needle decompression involves inserting a needle or catheter at the second intercostal space, the midclavicular line. Recent evidence suggests that the commonly used catheters do not have sufficiently penetrate the chest wall. There are also claims that a lateral approach to needle decompression is easier and safer than the traditional anterior approach. The purpose of this study is to evaluate the optimal approach for needle decompression for the Korean population by measuring chest wall thicknesses at the points used for both the anterior and the lateral approaches. Methods: The chest wall thickness (CWT) of trauma victims who visited the Emergency Center of Pusan National University Hospital was measured by computed tomography (CT) images. The CWT was measured at the points used for the anterior and the lateral methods and was compared with the length of commonly used catheters, which is 45 mm. Results: The mean CWT at the second intercostal space, the midclavicular line, was shorter than the CWT at the 5th intercostal space, the anterior axillary line. However, the percentage of patients whose CWT was greater than 45 mm was larger when measured anteriorly (8.2%) that when measure laterally (5.7%). Female patients and those older than 60 were more likely to have an anterior CWT greater than 45 mm (28.2% for females and 15.5% for those older than 60). Conclusion: The percentage of trauma victims in Korea whose CWT is greater than 45 mm is lower than the values previously reported by other countries. However, females and older patients tend to have thicker chest walls, so the lateral approach would be suggested when performing needle decompression for such patients with suspected tension pneumothoraces.

급성실혈시의 식도운동 (The Motility of Esophagus in Acute Hemorrhage)

  • 박순일;신동훈
    • The Korean Journal of Physiology
    • /
    • 제6권2호
    • /
    • pp.39-48
    • /
    • 1972
  • Two polyethylene tubes were inserted into the esophagus of anesthetized rabbit in order to record the fluctuation of the intraluminal pressure through the orifices located near the tips of the tubes. The orifice of the first tube was 10 cm apart from the incisor of the rabbit and the orifice of the second tube was 5 cm below that of the first one. The tubes were filled with saline solution running at various rates ranging from 1.5 ml/min. to 4.2 ml/min. The tubes were connected to the pressure transducers and the electrical signals were recorded by the physiograph. When the peristaltic wave approached to the orifice a rise in the pressure was recorded, returning to the base line when the portion of the orifice was quiescent. The frequency of the peristaltic motion and the velocity of the wave were studied in connection with the flow rate of saline solution through the tubes and in the case of massive acute hemorrhage. The results obtained were as follows: 1. There was reflux of fluid induced during the procedure of the experiment. This outwrad flow through the pharynx seemed to elicite swallowing reflexes. Accordingly, the frequency of peristalsis of the esophagus was largely dependent on the flow rate of the fluid through the inserted tubes. By the flow rate of 1.5 ml/min., 2.5 ml/min., or 4.2 ml/min., the frequencies of the peristalsis were revealed to be $8.6{\pm}3.6/10min.,\;14.5{\pm}4.8/10min.\;or\;21.1{\pm}6.3/10min.,$ respectively. The velocity of peristalsis also coincided with the enhanced motility of the esophagus, showing $6.6{\pm}1.5\;cm/sec.,\;8.9{\pm}3.9\;cm/sec.,\;or\;12.4{\pm}4.6\;cm/sec.,$ respectively. 2. By acute hemorrhage, amounting to 2% of the body weight, the frequency of the peristalsis increased to twofold of the control and the propagation velocity also increased by 52 percent. 3. Retransfusion of the shed blood resulted in divergent responses. In some cases there were noticable ameliorations of the effects brought by acute hemorrhage, and in the others there were still increasing tendenies of the motility after the transfusion. 4. Some speculation was made about the possibility of a kind of relationship between the irreversibility of the hemorrhagic shock and the absence of responses by transfusion. 5. The peristalsis persisted even after complete disconnection at the midportion of the esophagus, reaffirming the view of a central regulation of the spatiotemporally coordinated motility, peristalsis.

  • PDF

말의 정소상체 정자의 동결 후 해동 온도 및 Incubation의 효과 (Effects of Incubation and Thawing Temperature on Frozen-thawed Stallion Epididymal Spermatozoa)

  • 김근중;이경본;이지혜;김은영;한길우;박강선;김민규
    • 한국수정란이식학회지
    • /
    • 제28권3호
    • /
    • pp.297-302
    • /
    • 2013
  • Cryopreservation of epididymal spermatozoa offers a potential tool for rescuing genetic material from males of genetically elite populations. Castration, catastrophic injury, sudden death or any other event that makes semen collection or mating impossible may prematurely terminate a stallion reproduction. Stallion epididymal spermatozoa vary widely in the loss of progressive motility, acrosomal integrity, and viability during freezing and thawing. The objective of this work was to investigate the effect of (1) freezing package types on cryopreservation efficiency, (2) thawing temperatures (37, 56 or $70^{\circ}C$) on Computer Assisted Sperm Analysis (CASA) parameters and (3) post-thawing incubation time (0, 1, 2 or 4h) on castrated stallion epididymis. Post-thawed sperm motility ranged between 59.69% and 64.28% ($56^{\circ}C$ and $37^{\circ}C$) in various thawing temperatures. When stallion epididymis sperm was frozen, straw was better than freezing tube on VCL (Velocity of Curvilinear Line) and VAP (Velocity of Average Path) parameter. Higher percentage of motility was observed at $37^{\circ}C$ thawing temperature even though no significant difference was observed among various temperatures. The motility, VCL, ALH (Amplitude of Lateral Head displacement), VAP, BCF (Beat-Cross Frequency) and STR (Straightness index) parameter of post-thawed sperm were significantly decreased by increasing the incubation time for all thawing temperatures. The present study showed that type of freezing package (Straw vs. Freezing tube) was not significantly different on cryopreservation efficiency. Furthermore, stallion epididymal spermatozoa frozen-thawed at $37^{\circ}C$ for 1 min resulted the highest proportion of motility and velocity movement. In addition, motility and viability of frozen-thawed stallion epididymal spermatozoa were also decreased by incubation.

레버 증폭 구조의 플렉서를 이용한 공초점 현미경의 개발 (The Development of Confocal Microscopy Using the Amplified Double-compound Flexure Guide)

  • 이상원;김위한;정영대;박민규;김지현;이상인;이호
    • 한국광학회지
    • /
    • 제22권1호
    • /
    • pp.46-52
    • /
    • 2011
  • 본 연구에서는 레버 증폭 구조를 이용한 플렉서 기반의 나노 스테이지를 설계, 제작하였다. 제작된 나노 스테이지를 샘플 스테이지로 채용한 공초점현미경을 개발하였다. 2차원 이미징의 구현을 위해서, 기존의 공초점현미경은 레이저를 이미징 평면상에 스캐닝하는 방식으로 구현된다. 본 연구에서는 백 나노미터의 구동정밀도를 가지는 나노 스테이지 위에 놓인 샘플을 2차원으로 스캐닝하면서 2차원 이미지를 구현할 수 있는 공초점현미경을 개발하였다. 플렉서 기반의 나노 스테이지는 이중 판스프링, 변위증폭 레버, PZT 엑추에이터 그리고 변위 센서로 구성 되어 있다. 스테이지의 구동 성능 해석을 위해 상용 유한요소 해석 프로그램을 이용하였다. 현미경에 사용되는 광원은 적색광 레이저이며, 레이저는 여러 광학요소를 거쳐 샘플스테이지의 샘플에 입사되고, 반사된 빛은 광센서인 PMT(Photo Multiplying Tube)로 계측되게 된다. 계측된 빛의 크기를 이용하여서 2차원 이미징을 구현하였다. 개발된 공초점 현미경으로 생쥐 귀의 피부조직을 관찰하여 현미경의 이미징 성능을 검증하였다. 설계된 샘플 스테이지는 기존의 공초점 현미경의 기계적인 Beam 스캐너를 대신함으로써 현미경의 광경로 및 전체시스템을 간소화 하였다.

고정식 초점형 SPECT에 있어, 선예도와 감도의 공간 균일성에 대한 평가 (Evaluation of Spatial Uniformity about Resolution and Sensitivity of a 'fixed focusing type SPECT')

  • 김재일;임정진;조성욱;노경운
    • 핵의학기술
    • /
    • 제23권1호
    • /
    • pp.54-58
    • /
    • 2019
  • Capillary tube 10개를 $^{99m}Tc$로 채워서 고정식-초점형 SPECT와 회전식-평형 SPECT 장비를 이용하여 선예도와 감도를 평가하였다. 그리고 이 데이터를 이용하여 검출-조사야 내에서의 평균값과 표준편차를 이용하여 균일도를 나타내는 변동계수를 평가하였다. 고정식-초점형 SPECT의 선예도 균일도와 감도 균일도는 회전식-평형 SPECT 에 비해 각각 68%, 110% 높게 평가되었다.

확산텐서영상 팬텀 제작을 위한 식물섬유 재료의 특성에 관한 연구 (A Study on the Characteristics of Plant Fiber Materials for Diffusion Tensor Imaging Phantom)

  • 이정훈
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제43권6호
    • /
    • pp.475-480
    • /
    • 2020
  • The purpose of this study was to reconstruct diffusion tensor tractography (DTT) using stem of garlic and asparagus for in vitro phantom of diffusion tensor imaging (DTI), and to compare and evaluate the fractional anisotropy (FA) value and the apparent diffusion coefficient (ADC) value to determine whether it can be used as materials for in vitro phantoms. Among various plant fibers such as stem of garlic, palmae, cotton, asparagus, etc., stem of garlic and asparagus, which are considered to be the most suitable for making phantoms, and whose shape is considered to be the most suitable for making phantoms, were selected and tests were conducted. Holes were made in a plastic bucket at an angle of 0°, 30°, 60°, 90°, and 120°, then tubes were inserted. In the tube, asparagus and stem of garlic were inserted as far in as possible, and the inserted tube was inserted into the center of the heat bathed gelatin to harden. We were able to reproduce DTT images in asparagus and stem of garlic. Fiber tissues of asparagus and stem of garlic did not show complete connectivity, but the reconstructed images of DTT showed good connectivity. The FA values of asparagus in the tubes were 0.198 at 0° (straight), 0.207 at 30°, 0.187 at 60°, 0.231 at 90°, and 0.204 at 120°. In addition, the FA values of stem of garlic in the tubes were 0.235 at 0°, 0.236 at 30°, 0.216 at 60°, 0.218 at 90°, and 0.257 at 120°. The ADC values of asparagus in the tubes were 1.545 at 0°, 1.677 at 30°, 1.629 at 60°, 1.535 at 90°, and 1.725 at 120°. In addition, the ADC values of stem of garlic in the tubes were 1.252 at 0°, 1.396 at 30°, 1.698 at 60°, 1.756 at 90°, and 1.466 at 120°. For the best expressed DTT reconstruction image, it showed the longest connectivity in the straight line as we hypothesized. In addition, when comparing the FA values and ADC values of fiber tissues of stem of garlic and asparagus, FA value was generally higher in stem of garlic and ADC value was slightly higher in asparagus.