• Title/Summary/Keyword: Tube Line

Search Result 366, Processing Time 0.025 seconds

A Study on the Safely of Vibration Characteristics on the Various Configuration of Tube (튜브 형상에 따른 진동 특성의 안전성 연구)

  • 신귀수
    • Journal of the Korean Society of Safety
    • /
    • v.15 no.3
    • /
    • pp.45-51
    • /
    • 2000
  • This paper studies the effect of vibrational characteristics of the various tubes analyzed though experiment. By an experiment analysis we found out that the factor of system vibration is fluid-structure interaction of tube line. In fluid-filled tube system we study on the influence that the natural frequency of system and the frequency of wave motion produce upon through three experiments. Three experiments are modal test on each tube, FRF in continuous system, and vibrating tests when the system is driving on. From the results of the experimental studies, we obtained that the natural frequencies of system are very important than wave induced vibrations. and according to the variation of configuration, the frequencies are different each other. And we found that though fluid passed away through the tube, the tendency of system vibration level was similar with the mode shape at the simple system.

  • PDF

Development of Temperature Control Technology of Root Zone using Multi-line Heating Methods in the Strawberry Hydroponics (다선식 가온방식을 이용한 딸기 수경재배의 배지 온도조절 기술 개발)

  • Kim, Ki-Dong;Ha, Yu-Shin;Lee, Ki-Myung;Park, Dae-Heum;Kwon, Soon-Hong;Choi, Won-Sik;Chung, Sung-Won
    • Journal of Bio-Environment Control
    • /
    • v.19 no.4
    • /
    • pp.189-194
    • /
    • 2010
  • A multi line electric tube consisted of XL pipes contained with 2~4 hot wires and water in it. The specification of one meter length multi-line electric tube was investigated and the proper number in the multi-line electric tube was determined. A multi line electric tube with three hot wires were found to be the most efficient for the media heating control system. Temperature rise of medium in the rice hulls media was faster than that in the perlite media, showed better insulation effect of rice hulls media. Temperature rise of medium with mulching on the top of the bed was faster than without mulching, resulted in the beneficial effect of temperature rise with mulching. The regression model for the rice hulls media with mulching air temperature of $5^{\circ}C$ were a = -0.1458 and b = -0.1088. Using the model, the temperature rise of medium during low temperature season can be predicted for the various media according to the different depths.

Vacuum / Plasma Lab Cart Design (진공 / 플라즈마 실험 카트 설계)

  • Gang, Chung-Hyeon;Gang, Dae-Hyeon;Ju, Jeong-Hun
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2016.11a
    • /
    • pp.187-187
    • /
    • 2016
  • 진공 압력에 따른 플라즈마 발생의 관계, 전압에 따른 방전 밝기, gas와 방전 전극에 따른 플라즈마 색의 변화 등 실험을 통하여 학부생들에게 진공 시스템과 플라즈마의 이해도를 높이기 위해 Geissler tube cart를 제작하였다. Pump는 TMP station (PFEIFFER Vacuum Hi Cube ECO 80)을 사용하였으며 reducer를 이용하여 CF-4.5"에서 CF-2.75" adaptor를 설치, gate valve를 연결하여 진공도를 조절 할 수 있게 하였으며, 5-way를 이용하여 왼쪽은 gas line, 정면 view port, 상단 geissler tube, 후면 compact full range gauge를 설치하였고, cart 제작 결과를 Fig. 1에 나타내었다. Geissler tube의 수치모델은 Fig. 2에 나타내었다. 저진공(<10-3 Torr) 영역부터 고진공(<10-4 Torr) 영역까지 진공도에 따른 방전을 관찰 할 수 있으며, 표면과 플라즈마 사이의 전위 변화에 따른 쉬스(sheath) 관찰, trans 와 slidacs를 이용하여 전압 조정이 가능하기 때문에 전압에 따른 방전 관찰과 gas line을 통한 gas 주입에 따른 색의 변화를 관찰이 가능하도록 설계하였다.

  • PDF

Simulation of the small Refrigeration Cycle as shape change of the Non-Adiabatic Capillary Tube (비단열 모세관의 형상 변경에 따른 소형 냉동 사이클 성능 해석)

  • Nam, Ki-Won;Yi, Dae-Yong;Park, Sang-Goo;Jeong, Ji-Hawn;Kim, Lyun-Su
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.550-555
    • /
    • 2009
  • The present simulation focuses on the effect of the shape of capillary tube-suction line heat exchangers(SLHX), The results in the three cases of the SLHX types show that both of the location and length of heat exchange section influence the coefficient of performance(COP) and cooling capacity. Simulation shows the COP may be improved by 4.6% and the cooling capacity may be improved by 13.6% in the Lateral type.

  • PDF

A Study on the Fouling Effect of Geothermal Water Scale in In-line tube Bank (직렬 관군에서 지열수스케일의 파울링 영향에 관한연구)

  • 윤석범
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.23 no.2
    • /
    • pp.131-139
    • /
    • 1999
  • An experimental study was conducted to investigate the fouling effects of geothermal water scale deposited onto a heating surface upon its forced convection heat transfer characteristics. Scales deposited onto the heating surfaces of heat exchangers seriously reduce the heat transfer perfor-mance and also increase the hydrodynamic drag. Accordingly fouling is an important problem in the design and operation of heat exchangers. The cylinders were settled in tandem with equal dis-tance between neighbouring cylinders and only the test cylinder was heated under the condition of constant heat flux. The Reynolds number was varied from 13000310 through 50003100. It is found that the heat transfer of the in-line tube banks greatly varies with the fouling of geothermal water scale especially its scale height. Further the local and average Nusselt numbers strongly depend upon the cylinder spacing and the Reynolds number.

  • PDF

MERGING AND FRAGMENTATION IN THE SOLAR ACTIVE REGION 10930 CAUSED BY AN EMERGING MAGNETIC FLUX TUBE WITH ASYMMETRIC FIELD-LINE TWIST DISTRIBUTION ALONG ITS AXIS

  • Magara, Tetsuya
    • Journal of The Korean Astronomical Society
    • /
    • v.52 no.4
    • /
    • pp.89-97
    • /
    • 2019
  • We demonstrate the subsurface origin of the observed evolution of the solar active region 10930 (AR10930) associated with merging and breakup of magnetic polarity regions at the solar surface. We performed a magnetohydrodynamic simulation of an emerging magnetic flux tube whose field-line twist is asymmetrically distributed along its axis, which is a key to merging and fragmentation in this active region. While emerging into the surface, the flux tube is subjected to partial splitting of its weakly twisted portion, forming separate polarity regions at the solar surface. As emergence proceeds, these separate polarity regions start to merge and then break up, while in the corona sigmoidal structures form and a solar eruption occurs. We discuss what physical processes could be involved in the characteristic evolution of an active region magnetic field that leads to the formation of a sunspot surrounded by satellite polarity regions.

A Study on the Weld Line Position for Hydroforming (Weld line위치에 따른 Hydroforming특성에 관한 연구)

  • 강대철;윤석만;전병희;오수익;전한수
    • Transactions of Materials Processing
    • /
    • v.9 no.5
    • /
    • pp.504-511
    • /
    • 2000
  • Hydroforming is a forming process enabling circular metal tubes to be produced in complex cross sections along curved axial paths. This forming process is widely used to manufacture parts in automotive industry. This paper presents bending and forming results to following angle of weld line positions. These compare to good bending, bad bending and without weld line model case. And then this result of after forming compare to each forming cases. The purpose of this paper is found that adaptive weld line position for bended final shape.

  • PDF

Fluid flow and heat transfer around tubes arranged in line (일행관군에서의 유동특성과 열전달현상에 관한 연구)

  • 부정숙;조석호;정규하
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.14 no.6
    • /
    • pp.1603-1612
    • /
    • 1990
  • An experimental study is conducted to investigate the fluid flow and heat transfer around tubes arranged in line. All measurements are performed at Reynolds number 1.58*10$^{4}$ with varing tube spacings from the small pitch ratio(L/D=1.25) to the large pitch ratio(L/D=3.0). Mean static pressures and mean temperatures of the surface of tubes and mean velocities and turbulent intensities in tube banks are measured. The flow patterns and the characteristics of heat transfer are strongly influenced by the tube spacings. Especially, in the case of very small spacings(L/D=1.25), the flow between neighboring tubes becomes very stagnant and the heat transfer decreases. In the case of each tube spacing, the characteristics of heat transfer around the 3rd, the 4th and the 5th tubes are nearly similar to one another, because the flow around tubes becomes stable at the 3rd tubes. The local heat transfer has the peak value near the reattachment point which has the peak value of pressure, but the local heat transfer for the 2nd tube of L/D=1.25 without reattaching has the peak value at .theta.=75.deg.. For each pitch ratio, the mean heat transfer increases gradually toward the downstream tubes, because the oncoming flow through neighboring tubes comes closer to the forward and rear surfaces of the tube and the turbulent intensity becomes larger in the downstream direction.

Analysis on System Effects of SUS Tube in Optical Fiber Composite Power Cable Systems Using EMTP (EMTP를 이용한 광 복합 지중송전케이블 광 유니트 금속관의 시스템 영향분석)

  • Jung, Chae-Kyun;Jang, Tai-In;Kang, Ji-Won
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.9
    • /
    • pp.1180-1185
    • /
    • 2014
  • This paper describes the effects on SUS tube of power optical fiber composite cable on underground transmission lines. The effects on grounding, air gap between SUS tube and metal sheath, contact resistance between outer semi-conducting layer and metal sheath and grounding of SUS tube application or not are variously analysed using EMTP in normal operating condition as well as single line to ground fault. From these results, in this paper, the scheme for protecting the electrically abnormal phenomena will be established on power-optical fiber composite cable of underground transmission lines. This paper can contribute to specification of grounding reference of SUS tube of optical fiber composite power cable system.