• Title/Summary/Keyword: Tube Line

Search Result 366, Processing Time 0.023 seconds

Development of Portable Preconcentration-Gas Chromatography System for Fast Analysis of Trace Benzene, Toluene and Xylene in Air (대기 중 극미량의 벤젠, 톨루엔 및 자일렌의 신속한 분석을 위한 휴대용 농축-기체 크로마토크래피 시스템 개발)

  • Jung, Young-Rim;Kim, Man-Goo
    • Analytical Science and Technology
    • /
    • v.14 no.5
    • /
    • pp.432-441
    • /
    • 2001
  • An automated on-line portable preconcentration-short column gas chromatograph was developed, which used preconcentrator using adsorption tube with Tenax-GR and Curie-point heating. The developed system operated with 3 steps of processing, preconcentration, thermal desorption, and analysis and cleaning, and could continued operating within 1~2 min cycle. The recoveries of preconcentrator for toluene was ranged between $94.7{\pm}6.6%$ and $103.8{\pm}3.1%$ with less than 7% of RSD. For benzene, toluene and xylene(BTX) standard gas test, IDL was 41, 49, $472ng/m^3$ benzene, toluene and o-xylene, respectively. The BTX mixture was analyzed within 30 sec with baseline separation by the system equipped with 4 m long capillary column. The deficiency of separation power caused by short column was solved by the control of sample injection volume and inlet/outlet pressure ratio. The automated portable preconcentration-short column gas chromatograph system was found to be useful for the continuous air monitoring of BTX at ppb levels in ambient air.

  • PDF

Comparison of Parallel and Fan-Beam Monochromatic X-Ray CT Using Synchrotron Radiation

  • Toyofuku, Fukai;Tokumori, Kenji;Kanda, Shigenobu;Ohki, Masafumi;Higashida, Yoshiharu;Hyodo, Kazuyuki;Ando, Masami;Uyama, Chikao
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.407-410
    • /
    • 2002
  • Monochromatic x-ray CT has several advantages over conventional CT, which utilizes bremsstrahlung white x-rays from an x-ray tube. There are several methods to produce such monochromatic x-rays. The most popular one is crystal diffraction monochromatization, which has been commonly used because of the fact that the energy spread is very narrow and the energy can be changed continuously. The alternative method is the use of fluorescent x-ray, which has several advantages such as large beam size and fast energy change. We have developed a parallel-beam and a fan-beam monochromatic x-ray CT, and compared some characteristics such as accuracy of CT numbers between those systems. The fan beam monochromatic x-rays were generated by irradiating target materials by incident white x-rays from a bending magnet beam line NE5 in 6.5 GeV Accumulation Ring at Tukuba. The parallel beam monochromatic x-rays were generated by using a silicon double crystal monochromator at the bending magnet beam line BL-20BM in Spring-8. A Cadmium telluride (CdTe) 256 channel array detector with 512mm sensitive width capable of operating at room temperature was used in the photon counting mode. A cylindrical phantom containing eight concentrations of gadolinium was used for the fan beam monochromatic x-ray CT system, while a phantom containing acetone, ethanol, acrylic and water was used for the parallel monochromatic x-ray CT system. The linear attenuation coefficients obtained from CT numbers of those monochromatic x-ray CT images were compared with theoretical values. They showed a good agreement within 3%. It was found that the quantitative measurement can be possible by using the fan beam monochromatic x-ray CT system as well as a parallel beam monochromatic X-ray CT system.

  • PDF

Measurement of Electron Temperature and Number Density and Their Effects on Reactive Species Formation in a DC Underwater Capillary Discharge

  • Ahmed, Muhammad Waqar;Rahman, Md. Shahinur;Choi, Sooseok;Shaislamov, Ulugbek;Yang, Jong-Keun;Suresh, Rai;Lee, Heon-Ju
    • Applied Science and Convergence Technology
    • /
    • v.26 no.5
    • /
    • pp.118-128
    • /
    • 2017
  • The scope of this work is to determine and compare the effect of electron temperature ($T_e$) and number density ($N_e$) on the yield rate and concentration of reactive chemical species ($^{\bullet}OH$, $H_2O_2$ and $O_3$) in an argon, air and oxygen injected negative DC (0-4 kV) capillary discharge with water flow(0.1 L/min). The discharge was created between tungsten pin-to pin electrodes (${\Phi}=0.5mm$) separated by a variable distance (1-2 mm) in a quartz capillary tube (2 mm inner diameter, 4 mm outer diameter), with various gas injection rates (100-800 sccm). Optical emission spectroscopy (OES) of the hydrogen Balmer lines was carried out to investigate the line shapes and intensities as functions of the discharge parameters such as the type of gas, gas injection rate and inter electrode gap distances. The intensity ratio method was used to calculate $T_e$ and Stark broadening of Balmer ${\beta}$ lines was adopted to determine $N_e$. The effects of $T_e$ and $N_e$ on the reactive chemical species formation were evaluated and presented. The enhancement in yield rate of reactive chemical species was revealed at the higher electron temperature, higher gas injection rates, higher discharge power and larger inter-electrode gap. The discharge with oxygen injection was the most effective one for increasing the reactive chemical species concentration. The formation of reactive chemical species was shown more directly related to $T_e$ than $N_e$ in a flowing water gas injected negative DC capillary discharge.

Development of Servo Type Angle-of-Attack Sensor for UAV (무인항공기용 서보형 받음각센서 개발)

  • Park, Mi-Hyun;Kim, Sung-Su;Ryoo, Chang-Kyung;Choi, Kee-Young;Park, Choon-Bae
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.37 no.5
    • /
    • pp.511-517
    • /
    • 2009
  • A servo type angle of attack sensor using the null-seeking method is designed and its characteristics are analyzed in this study. Angle-of-attack in the null-seeking method is given by the probe rotation angle with respect to the body reference line when pressure difference measured in two holes on the probe becomes zero. This method provides highly accurate and uniform angle-of-attack measurements over all range. Hence, this kind of angle-of-attack sensor is adequate for unmanned aerial vehicles(UAVs). In this paper, we first analyze the requirements for developing angle-of-attack sensors. And the servo type angle-of-attack sensor is then designed and fabricated. The on-board angle-of-attack calculation algorithm is also developed. Finally, the characteristics of the developed angle-of-attack sensor are identified through MATLAB Simulink and wind tunnel tests.

Development of Eddy Current Testing System using Magnetic Saturation in ferromagnetic Materials (자기포화를 이용한 강자성체의 와전류검사장비 개발)

  • Sung, Je-Joong;Shin, Young-Hoon;Um, Tae-Gun;Kang, Seok-Chul;Kweon, Young-Ho;Suh, Dong-Man
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.23 no.4
    • /
    • pp.356-363
    • /
    • 2003
  • An eddy current testing system was developed for detection of flaws in the ferromagnetic steel tubes. Because the eddy current signals from the ferromagnetic steel tubes could be distorted easily due to an irregularity of magnetic permeability, magnetic saturation is required to suppress this variation of magnetic fields. A magnetic saturation probe with the Hemholtz coil was designed for the inspection of the steel tubes. The bandwidth pass filters were adapted to minimize the noise from the DC magnetization. When using the designed test probe, the flaw signals could be discriminated from the noise. The system was tested at the production line and showed a capability of detecting flaws, like a drilled hole of the diameter of 2.0mm at the moving speed of 1m/sec.

K-band Predistortive Linearizer of Reflective Diode Structure for Satellite TWTA Using Carrier Complex Power Series (Carrier Complex Power Series를 이용한 K-대역 위성 TWTA용 반사형 다이오드 구조의 전치왜곡 선형화기)

  • Jeong Hee-Young;Jeong Yong-Chae;Yom In-Bok
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.16 no.6 s.97
    • /
    • pp.644-651
    • /
    • 2005
  • In this paper, a new predistortion method to reduce nonlinearity or a traveling wave tube amplifiers(IWTAs) is proposed. Nonlinear transfer characteristics of TWTA are analyzed using carrier complex power series. Inverse carrier complex power series or a predistortion linearizer to linearizer TWTA are also proposed. The inverse nonlinear distortion characteristics of predistorter can be realized with reflective structure that is composed of Schottky diode and resistive-terminated transmission line. The AM-to-AM and the AM-to-PM characteristics for TWTA by proposed predistortive linearizer on K-band were improved from -5.825 dB and -37.321^{\circ} to 0.786 dB and 6.742^{\circ}, respectively.

The Characteristic Modes and Structures of Bluff-Body Stabilized Flames in Supersonic Coflow Air

  • Kim, Ji-Ho;Yoon, Young-Bin;Park, Chul-Woung;Hahn, Jae-Won
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.13 no.3
    • /
    • pp.386-397
    • /
    • 2012
  • The stability and structure of bluff-body stabilized hydrogen flames were investigated numerically and experimentally. The velocity of coflowing air was varied from subsonic velocity to a supersonic velocity of Mach 1.8. OH PLIF images and Schlieren images were used for analysis. Flame regimes were used to classify the characteristic flame modes according to the variation of the fuel-air velocity ratio, into jet-like flame, central-jet-dominated flame, and recirculation zone flame. Stability curves were drawn to find the blowout regimes and to show the improvement in flame stability with increasing lip thickness of the fuel tube, which acts as a bluff-body. These curves collapse to a single line when the blowout curves are normalized by the size of the bluff-body. The variation of flame length with the increase in air flow rate was also investigated. In the subsonic coflow condition, the flame length decreased significantly, but in the supersonic coflow condition, the flame length increased slowly and finally reached a near-constant value. This phenomenon is attributed to the air-entrainment of subsonic flow and the compressibility effect of supersonic flow. The closed-tip recirculation zone flames in supersonic coflow had a reacting core in the partially premixed zone, where the fuel jet lost its momentum due to the high-pressure zone and followed the recirculation zone; this behavior resulted in the long characteristic time for the fuel-air mixing.

Electronic Ballast Design for Power Factor Improvement and Harmonic Reduction (역률개선 및 고조파 저감을 위한 전자식 안정기 설계)

  • Lee, Chung-Sik;Cho, Moon-Taek;Na, Seung-Kwon
    • Journal of Advanced Navigation Technology
    • /
    • v.18 no.5
    • /
    • pp.483-489
    • /
    • 2014
  • Proposed electronic ballast circuit for harmonic reduction includes adding lossless snubber circuit to DC-DC converter. To get inverter for changing DC-AC, a lamp has been changed to equivalence resistance in the standard lamp voltage and current data, also inverter circuit has been interpreted by being changed to R, L, C equivalence circuit. Using converted equivalent circuit, the most suitable circuit constant which can satisfy the characteristics of fluorescent lamps has been decided on and finally designed. It could not only eliminate distortion waveform from pulsation frequency in inverter direct side current but also reduce considerably pulsation rate and switching loss by making input current of inverter discontinuous. The validity for the results of this study has been verified through the experiment to measure harmonic occurrence after applying a newly-manufactured product of electronic ballast to 40 W line tube style fluorescent lamps.

Performance of membrane filtration in the removal of iron and manganese from Malaysia's groundwater

  • Kasim, Norherdawati;Mohammad, Abdul Wahab;Abdullah, Siti Rozaimah Sheikh
    • Membrane and Water Treatment
    • /
    • v.7 no.4
    • /
    • pp.277-296
    • /
    • 2016
  • The aim of this research was to investigate the ability of nanofiltration (NF) and ultrafiltration (UF) membranes as a filtration unit for groundwater treatment for drinking water resources. Commercial membranes denoted as TS40, TFC-SR3 and GHSP were used to study the performance based on rejections and fluxes. The investigation has been conducted using natural groundwater obtained from a deep tube well with initial concentration of iron (Fe) and manganese (Mn) at 7.15 mg/L and 0.87 mg/L, respectively. Experimental results showed that NF membranes exhibited higher fluxes than UF membrane with pure water permeability at 4.68, 3.99 and $3.15L.m^{-2}.h^{-1}.bar^{-1}$, respectively. For metal rejection, these membranes have performed higher removal on Fe with TS40, TFC-SR3 and GHSP membranes having more than 82%, 92% and 86% respectively. Whereas, removal on Mn only achieved up to 60%, 80% and 30%, for TS40, TFC-SR3 and GHSP membranes respectively. In order to achieve drinking water standard, the membranes were efficient in removing Fe ion at 1 and 2 bar in contrast with Mn ion at 4 and 5 bar. Higher rejection of Fe and Mn were achieved when pH of feed solution was increased to more than 7 as TFC-SR3 membrane was negatively charged in basic solution. This effect could be attributed to the electrostatic effect interaction between membrane material and rejected ions. In conclusion, this study proved that NF membrane especially the TFC-SR3 membrane successfully treated local groundwater sources for public drinking water supply in line with the WHO standard.

Optimal Supply Scheme of Solar Hot Water Heating Systems for the Apartment Complexes (공동주택용 태양열 급탕시스템 최적공급 방안 해석연구)

  • Lee, Chul-Sung;Park, Ja-Son;Park, Jae-Wan;Shin, U-Cheul;Yoon, Jong-Ho
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2008.11a
    • /
    • pp.245-250
    • /
    • 2008
  • This study is on the availability of solar thermal energy in Korean high-rise apartment complex depending on the installation type of solar collectors to roof or facade of building. Firstly, solar access evaluation on the roof and the facade of apartment buildings was carried out. The total thermal load of each apartment unit and building was investigated and matched with the energy which was produced by solar thermal systems on the facade. The considered layout patterns of apartment buildings were '一type', 'alternative 一type', 'ㄱtype' and 'ㅁtype' and that was analyzed in prior studies. Extensive dynamic hourly energy simulations with the solar thermal system were Performed with the TRNSYS of SEL. We assumed that the apartment complex is composed of 9 buildings and located in Daejeon. The collectors are the heat-pip evacuated tube collectors and the number of collectors are 45 tubes We assumed that the collectors are installed on the balcony of each unit and the angle of incilnation is $90^{\circ}$. As a result, the supply amount of solar thermal systems is about 4,850,086kJ/hr and the solar fraction is about 66%. The solar fraction according to each azimuth is about 66% on the south, 62% on the south-east $30^{\circ}$ and 56% on the south-east $60^{\circ}$. So, we quantitatively got a line on the optimal azimuth for installing the solar thermal systems. The solar fraction has differences from 5% to 15% of each floor, 6th, 12th and 20th and those tendencies are same in analyzed each 4 types of the apartment complexes.

  • PDF