• Title/Summary/Keyword: Tube Length

Search Result 1,025, Processing Time 0.038 seconds

Effect of tube area on the behavior of concrete filled tubular columns

  • Gupta, P.K.;Verma, V.K.;Khaudhair, Ziyad A.;Singh, Heaven
    • Computers and Concrete
    • /
    • v.15 no.2
    • /
    • pp.141-166
    • /
    • 2015
  • In the present study, a Finite Element Model has been developed and used to study the effect of diameter to wall thickness ratio (D/t) of steel tube filled with concrete under axial loading on its behavior and load carrying capacity. The model is verified by comparing its findings with available experimental results. Influence of thickness and area of steel tube on strength, ductility, confinement and failure mode shapes has been studied. Strength enhancement factors, load factor, confinement contribution, percentage of steel and ductility index are defined and introduced for the assessment. A parametric study by varying length and thickness of tube has been carried out. Diameter of tube kept constant and equals to 140 mm while thickness has been varied between 1 mm and 6 mm. Equations were developed to find out the ultimate load and confined concrete strength of concrete. Variation of lateral confining pressure along the length of concrete cylinder was obtained and found that it varies along the length. The increase in length of tubes has a minimal effect on strength of tube but it affects the failure mode shapes. The findings indicate that optimum use of materials can be achieved by deciding the thickness of steel tube. A better ductility index can be obtained with the use of higher thickness of tube.

A Study on the Aerodynamic Noise of a Supersonic Exhaust Nozzle of Slotted Tube (슬롯관형 초음속 배기노즐의 공력소음에 관한 연구)

  • Lee, Dong-Hoon;Seto, Kunisato
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.24 no.1
    • /
    • pp.132-142
    • /
    • 2000
  • The objective of this study is to experimentally investigate the noise propagating characteristics, the noise reduction mechanism and the performance of a slotted tube attached at the exit plane of a circular convergent nozzle. The experiment is performed through the systematic change of the jet pressure ratio and the slot length under the condition of two kinds of open area ratios, 25% and 51%. The open area ratio calculated by the tube length equivalent for the slot length is defined as the ratio of the total slot area to the surface area of a slotted tube. The experimental results for the near and far field sound, the visualization of jet structures and the static pressure distributions in the jet passing through a slotted tube are presented and explained in comparison with those for a simple tube. The propagating characteristics of supersonic jet noises from the slotted tube is closely connected with the slot length rather than the open area ratio, and its propagating pattern is similar to the simple tube. It is shown that the slotted tube has a good performance to suppress the shock-associated noise as well as the turbulent mixing noise in the range of a limited jet pressure and slot dimension. The considerable suppression of the shock‘associated noise is mainly due to the pressure relief caused by the high-speed jets passing through the slots on the tube. Both the strength of shock waves and the interval between them in a jet plume are decreased by the pressure relief. Moreover, the pressure relief is divided into the gradual and the sudden relief depending upon the open area ratio of the slotted tube. Consequently, the shock waves in a jet plume are also changed by the type of pressure relief. The gradual pressure relief caused by the slotted tube with the open area ratio 25% generates the weak oblique shock waves. On the contrary, the weak normal shock waves appear due to the sudden pressure relief caused by the slotted tube with the open area ratio 51%.

A Study on Critical Heat Elux Characteristics in a Two-Phase Concentric-Tube Thermosyphon (2중관형 2상 열사이폰의 한계열유속 특성에 관한 연구)

  • Kim, Wook
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.26 no.10
    • /
    • pp.1419-1426
    • /
    • 2002
  • An experimental study was made to elucidate critical heat flux(CHF) characteristics in a two-phase concentric-tube thermosyphon. The experiment was performed by using saturated water, over the experimental range of configuration: inner diameter of heated outer tube D=12mm, outer diameter of unheated inner tube do=3 to 10mm and heated tube length L=100 to 1000mm. The experiment shows that the CHF is enhanced with increase in the inner tube diameter, and that the CHF decreases beyond a certain diameter of the inner tube. There is an optimum diameter for inner tube that maximizes the CHF, for each tube length and test liquid. The CHF maximum is about two to eight times as large as that without an inner tube. For a large inner tube, the CHF characteristics is similar to that for natural convective boiling in a vertical annular tube.

Buckling Analysis of Guide Tube in the Spent Fuel Skeleton (핵연료 집합 구조체의 가이드튜브에 대한 죄굴응력 해석)

  • 김영환;윤지섭;정재후;홍동희;송상호
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.413-416
    • /
    • 2000
  • The spent fuel skeleton is processed in the cutting processing after compacting. If the cutting length is processed in the same interval length. The spent fuel skeleton is stayed on the connection of bottom nozzle and guide tube. In the case, because the compressive stress is loaded along the length, the guide tube is generated the buckling stress and the deforming. But the deformed guide tube interrupted the guide tube inserted through compressive room. therefore, it is experimented for the optimum buckling stress and the preventing of guide deformed. This paper is predicted the all over buckling stress of the spent fuel skeleton by using experiment. The guide of Spent fuel skeleton have buckling characteristics of the medium column. The experiment and analysis is conducted by the comparing among the equation of Euler, Johnson and Engresser. The fittest one of method is Engresser equation.

  • PDF

Gas Diffusion Tube Dimension in Sensor-Controlled Fresh Produce Container System to Maintain the Desired Modified Atmosphere

  • Jo, Yun Hee;An, Duck Soon;Lee, Dong Sun
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.19 no.2
    • /
    • pp.61-65
    • /
    • 2013
  • Modified atmosphere (MA) of reduced $O_2$ and elevated $CO_2$ concentrations has been used for keeping the quality of fresh produce and extending the shelf life. As a way to attain the beneficial MA package around the produce, a gas diffusion tube or perforation can be attached onto the container and controlled on real time in its opening/closing responding to $O_2$ and $CO_2$ concentrations measured by gas sensors. The timely-controlled opening of the gas diffusion tube can work in harmony with the produce respiration and help to create the desired MA. By use of the mathematical modeling, the effect of tube dimension on the controlled container atmosphere was figured out in this study. Spinach and king oyster mushroom were used as typical commodities for designing the model container system (0.35 and 0.9 kg in 13 L, respectively) because of their respiration characteristics and the optimal MA condition ($O_2$ 7~10%/$CO_2$ 5~10% for spinach; $O_2$ 2~5%/$CO_2$ 10~15% for mushroom). With a control logic for the gas composition to stay as close as possible to optimum MA window without invading injurious low $O_2$ and/or high $CO_2$ concentrations, the atmosphere of the sensor-controlled container could stay at its lower $O_2$ boundary or upper $CO_2$ limit under certain tube dimensional conditions. There were found to be the ranges of the tube diameter and length allowing the beneficial MA. The desired range of the tube dimension for spinach consisted of combinations of larger diameter and shorter length in the window of 0.3~2 cm diameter and 0.2~10 cm length. Similarly, that for king oyster mushroom was combinations of larger diameter and shorter length in the window of 0.9~2 cm diameter and 0.2~3 cm in length. Clear picture on generally affordable tube dimension range may be formulated by further study on a wide variety of commodity and pack conditions.

  • PDF

An Experimental Study on the Performance of Inverter Heat Pump with a Variation of Frequency and Capillary Size

  • Choi, Jong-Min;Kim, Yong-Chan;Kim, Jong-Yup
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.6
    • /
    • pp.27-35
    • /
    • 1998
  • An experimental study was performed to investigate the optimum cycle of an inverter heat pump as a function of frequency. The performance of the inverter heat pump with the rated cooling capacity of 4,141 W(3,550kcal/h) was measured with a variation of frequency, indoor and outdoor temperature, and length of capillary tube in the psychrometric test room. As a base case, the inverter heat pump with the standard capillary length of l,000mm(optimum size for the frequency of 60Hz) and ASHRAE Test condition "A" was tested by varying frequency from 30Hz to 80Hz. Then, the optimum cycles were investigated by varying the length of capillary tube at each frequency level of 30, 60 and 80Hz. Based on the experimental data, the change of system characteristics between the optimum and the base case were analyzed for each selected frequency level. Generally, for low frequency level(30Hz), the longer length of the capillary tube compared with the standard size showed the higher energy efficiency ratio(EER), while for high frequency level(80Hz) the shorter length of the capillary tube showed the higher EER.

  • PDF

An experimental study on the performance of inverter heat pump with a variation of frequency and capillary size (인버터 열펌프의 주파수 및 모세관 길이 변화에 따른 시스템 성능특성의 실험적 연구)

  • Choi, J.M.;Kim, Y.C.;Kim, J.Y.;Bae, Y.D.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.9 no.1
    • /
    • pp.64-72
    • /
    • 1997
  • An experiment study was performed to investigate the optimum cycle of an inverter heat pump as a function of frequency. The performance of the inverter heat pump with the rated cooling capacity of 4141W(3550kcal/h) was measured with a variation of frequency, indoor and outdoor temperature, and length of capillary tube in the psychrometric test room. As a base case, the inverter heat pump with the standard capillary length of 1000mm which was optimum size for the frequency of 60Hz and ARHRAE Test condition A was tested by varying frequency from 30Hz to 80Hz. Then, the optimum cycle was invesigated by varying the length of capillary tube at each frequency levels of 30, 60 and 80Hz. Based on the experimental data, the change of system characteristics between the optimum and the base case were analyzed for each selected frequency levels. Generally, for low frequency level(30Hz), the longer length of the capillary tube compared with the standard size showed the higher EER, while for high frequency level(80Hz) the shorter length of the capillary tube showed the higher EER.

  • PDF

Parametric Study on Performance of Inertance Pulse Tube Cryocooler

  • Lee, K.H.;Rhee, J.;Kim, J.S.
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.15 no.2
    • /
    • pp.205-211
    • /
    • 2014
  • The design parameters to affect the cooling capacity of a cryocooler were examined with the application of numerical modeling to optimize an inertance pulse tube cryocooler. This modeling includes the regenerator, pulse tube, inertance tube, gas reservoir, and heat exchangers. One-dimensional modeling on strings of acoustic and thermoacoustic elements was applied to compare the design parameters. The diameter and length of the pulse tube can significantly affect the cooling capacity and efficiency. The aftercooler was optimized by maintaining a certain size. The efficiency also improved as the length of inertance tube and volume of gas reservoir are increased. It was confirmed that effective design parameters are critical to the performance of an inertance pulse tube cryocooler considering the comparison of the dimensions of each part to optimize its cooling power and efficiency.

Optimization Design of an Aluminum Tube for an OPC Drum using Taguchi's Experimental Method (다구찌 실험법을 이용한 OPC 드럼용 튜브의 최적설계 연구)

  • Kim, Chung-Kyun;Oh, Kyoung-Seok
    • Tribology and Lubricants
    • /
    • v.23 no.3
    • /
    • pp.103-108
    • /
    • 2007
  • In this paper, the optimized design and strength analysis have been presented based on the finite element and Taguchi's experimental methods. The stress, strain and displacement characteristics of OPC drum tubes are affected by rolling contact pressures between an OPC drum tube and a paper, design parameters of an aluminum tube and material properties. The OPC drum tubes with nine different geometrical models are analyzed for design parameters that are related to the outer diameter, the thickness, and the length of an aluminum tube for a toner cartridge. The optimized design parameters for an aluminum tube may be selected as the outer diameter of 28 mm, the thickness of 0.8 mm, and the length of 220 mm. But the currently used aluminum tube for a laser printer is fairly optimized based on the Taguchi's design analysis. The calculated FEM results showed that the affection ratio of the design parameter t, which may control the strength of an aluminum tube, is the most influential parameter among the length and an outer diameter of a tube.

An Experimental Study on the 2nd,3rd Harmonic Characteristic for open-tube-type and close-tube-type Thermoacoustic Refrigerators (밀폐관형과 개방관형 열음향 냉동기의 2차, 3차 하모닉에 관한 특성 연구)

  • 송규조;박종호;고득용;박성제;김효봉;박영선
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2002.02a
    • /
    • pp.193-196
    • /
    • 2002
  • The thermoacoustic refrigerator has not only considerable possibility but also commercial usability, because it has high reliability, lower vibration, no moving part, and can easily be constructed. In order to determine the optimum resonant tube length and the frequency, the open-tube-type(3$\lambda$/4) and close- tube - type (2$\lambda$/2) thermoacoustic refrigerator were constructed. In third harmonic, the temperature difference of 3$\lambda$/4 refrigerator was $53^{\circ}C$(resonator length :400mm). In second harmonic, the temperature difference of 2$\lambda$/2 refrigerator was $51^{\circ}C$(resonator length :400mm).

  • PDF