• Title/Summary/Keyword: Tube Diameter

Search Result 1,273, Processing Time 0.025 seconds

A Study on Heat Transfer Characteristics of a Closed Two-Phase Thermosyphon with a Low Tilt Angle (낮은 경사각을 갖는 밀폐형 2상 열사이폰의 열전달 특성에 관한 연구)

  • 김철주;강환국;김윤철
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.8 no.1
    • /
    • pp.1-12
    • /
    • 1996
  • In lots of application to heat exchanger systems, closed two-phase thermosyphons are tilted from a horizontal. If the tilt angle, especially, is less than 30$^{\circ}$, the operational performances of thermosyphon are highly dependent on tilt angle. The present study was conducted to better understand such operational behaviors as mech-anni는 of phase change, and flow patterns inside a tilted thermosyphon. For experiment, an ethanol thermosyphon with a 35% of fill charge rate was designed and manufactured, using a copper tube with a diameter 19mm and a length 1500mm. Through a series of test, the tilt angle was kept constant at each of 4 different values in the range 10~25deg. and the heat supply to the evaporator was stepwisely increased up to 30㎾/$m^2$. When a steady state was established to the thermosyphon for each step of thermal loads, the wall temperature distribution and vapor temperature at the condenser were measured. The wall temperature distributions demonstrated a formation of dry patch in the top end zone of the evaporator, with a values of temperature 20~4$0^{\circ}C$ higher than the wetted surface for a moderate heat flux q≒20㎾/$m^2$. Inspite of the presence of hot dry patch, however, the mean values of boiling heat transfer coefficient at the evaporator wall were still in a good agreement with those predicted by Rohsenow's formula, which was based on nucleate boiling. For the condenser, the wall temperatures were practically uniform, and the measured values of condensation heat transfer coefficient were 1.7 times higher than the predicted values obtained from Nusselt's film condensation theory on tilted plate. Using those two expressions, a correlation was formulated as a function of heat flux and tilt angle, to determine the total thermal resistance of a tilted thermosyphon. The correlation formula showed a good agreement with the experimental data within 20%.

  • PDF

Fabrication of KSTAR PF CICC (KSTAR PF Coil용 CICC 제작)

  • Lim, B.;Lee, S.;Choi, J.;Jung, W.;Park, H.;Chu, Y.;Park, K.;Baek, S.;Kim, K.
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2003.10a
    • /
    • pp.301-303
    • /
    • 2003
  • The KSTAR(Korea Superconducting Tokamak Advanced Research) superconducting magnet system consist of 16 TF(Toroidal Field) and 14 PF(Poloidal Field) coils. Internally-cooled cabled superconductors will be used for the magnet system. The magnet system adopt a superconducting CICC (Cable-In-Conduit Conductor) type. The KSTAR PF 6, 7 CICCs use NbTi Superconducting cable with stainless steel 316LN conduit while the other PF CICC use Incoloy 908 conduit. For the fabrication of PF CICC, superconducting cables have been fabricated and the cable has the diameter of 22.3mm. A continuous CICC jacketing system is developed for the CICC jacketing and the jacketing system uses the tube-mill process, which consists of forming, welding, sizing and squaring procedures. The cabling and the jacketing process is described. The welding condition and design specification of CICCs are also discussed. The fabrication results including the geometrical specification and the void fraction will be discussed.

  • PDF

A Study on the Fabrication of CsI(T1) Radiation Sensor and its Spectroscopic Characteristics (CsI(T1) 방사선센서의 제작 및 분광특성 연구)

  • 권수일;신동호
    • Progress in Medical Physics
    • /
    • v.13 no.1
    • /
    • pp.44-50
    • /
    • 2002
  • CsI(T1) single crystal was grown in a Bridgman growing apparatus, which has the diameter of 11 mm and the mole ratio of 0.001 mol%. Radiation sensors were made with CsITl)crystal and two photodiodes, and measured spectroscopic characteristics and linearity for gamma-ray and X-ray. The energy resolution of CsI(T1) radiation sensor has been measured with $^{22}$ Na, $^{137}$ Cs and $^{60}$ Co gamma standard sources. Also output linearity of CsITl) sensor was measured for diagnostic radiation region. The energy resolutions of CsI(T1) radiation sensor for 0.511MeV gamma-ray from Na-22 source, 0.662MeV from Cs-137 source, and 1.17MeV and 1.332MeV from Co-60 source were 13.2%, 8.3%, 6.7%, and 5.1% respectively. Also the output linearity up to 80mAs current for 60kVp, 80kvp, 100kVp, 120kVp tube voltages has been studied.

  • PDF

Fabrication of CNT/MgCl2-Supported Ti-based Ziegler-Natta Catalysts for Trans-selective Polymerization of Isoprene

  • Cao, Lan;Zhang, Xiaojie;Wang, Xiaolei;Zong, Chengzhong;Kim, Jin Kuk
    • Elastomers and Composites
    • /
    • v.53 no.3
    • /
    • pp.158-167
    • /
    • 2018
  • In this study, in-situ trans-selective polymerization of isoprene was carried out using titanium-based Ziegler-Natta catalysts. The catalysts were prepared by high-energy ball milling. Individually Large-inner-diameter carbon nanotubes (CNTL), and hydroxylated carbon nanotubes (CNTOH), along with magnesium chloride ($MgCl_2$) were used as the carriers for the catalysts. The optimum ball-milling time for preparing the $CNT/MgCl_2/TiCl_4$ Ziegler-Natta catalysts was 4 h. The $CNTOH/MgCl_2/TiCl_4$ catalyst showed a higher efficiency than that of the $CNTL/MgCl_2/TiCl_4$ catalyst, based on the rate of polymerization. The effects of the CNT-filler type on the isoprene polymerization behaviors and polymer properties were investigated. The morphologies of the trans-1,4-polyisoprene (TPI)/CNT and TPI/CNTOH nanocomposites exhibited a tube-like shape, and the CNTL and CNTOH fillers were well dispersed in the TPI matrix. In addition, the thermal stability of TPI significantly increased upon the introduction of a small amount of both CNTL/CNTOH fillers (0.15 wt%), owing to the satisfactory dispersion of the CNTL/CNTOH in the TPI matrix.

A Case of RUL Bronchopleural Fistula Occluded by Flexible Bronchoscope with Endobronchial Watanabe Spigot (EWS) (기관지내시경을 통한 Endobronchial Watanabe Spigot (EWS) 삽입으로 치료한 기관지흉막루 1례)

  • Choi, Young In;Cho, Jin Hui;Shim, Jin Young;Sheen, Seung Soo;Oh, Yoon Jung;Park, Joo Hun;Hwang, Sung Chul;Lee, Sung Soo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.58 no.4
    • /
    • pp.404-409
    • /
    • 2005
  • An 86 year old woman was admitted complaining of dyspnea and right pleuritic pain with a 5 week durations. A physical examination, chest X-ray, and diagnostic thoracentesis upon admission revealed findings consistent with severe pneumonia and empyema on the right lung. Despite the insertion of a chest tube and negative suction via Emersion pump, the continuous air leakage was sustained, and a bronchopleural fistula (BPF) was found on the chest-CT. A flexible bronchoscopic occlusion with an Endobronchial Watanabe Spigot (EWS) was performed after 56 days of admission. An 5 mm diameter EWS was successfully inserted into the anterior segmental bronchus of the right upper lobe by flexible bronchoscope. There was no aAir leakage detected after this procedure. The patient was discharged 30 days after the EWS occlusion.

Characteristics of Turbulent Flows and Suspended Sediment Transport in Open-channel with Submerged Vegetation (침수식생 개수로에서 난류 및 부유사 이동 특성)

  • Yang, Won-Jun;Jang, Ji-Yeon;Choi, Sung-Uk
    • Journal of Korea Water Resources Association
    • /
    • v.44 no.5
    • /
    • pp.417-427
    • /
    • 2011
  • The open-channel flow with submerged vegetation shows distinct features in two separate regions, namely upper and vegetation layers. In the upper layer, the flow is akin to the open-channel flow, while the flow in the vegetation layer is relatively uniform with suppressed turbulence due to vegetation stems. This paper presents laboratory experiments to investigate the characteristics of turbulent flows and suspended sediment transport in open-channel flows with submerged vegetation. An open-channel facility, 0.5 m wide and 12 m long, was used for laboratory experiments. Various discharges were employed with depth ratios of 2~3, and wooden cylinders were used for vegetation. To make equilibrium suspension, sediment particles of median diameter of 75 ${\mu}M$ were fed until capacity condition. Laser Doppler velocimeter was used to measure instantaneous velocity, and direct sampling with vinyl tube was used to measure the concentration of suspended sediment. Using the sampled data, the mean flow and turbulence structures were provided and characteristics of suspended sediment concentration with Rouse number were presented.

Zeolite Membrane for High Temperature Gas Separation

  • Li, G.;Kikuchi, E.;Matsukata, M.
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 2004.05a
    • /
    • pp.86-89
    • /
    • 2004
  • The present study reports the preparation of a compact ZSM-5 membrane showing high thermal stability and high separation factors, especially n-/i-butane isomers at high temperatures. ZSM-5 membrane was prepared on a porous $\alpha$-Al$_2$O$_3$ tube (an average pore diameter, ca. 100 nm) at 18$0^{\circ}C$ by the seed-assisted crystallization method. The XRD and SEM results showed that a thin zeolite layer (ca. 1 ${\mu}{\textrm}{m}$) was formed on the support surface. The single gas permeances of $N_2$, H$_2$, SF$_{6}$, n-butane, and i-butane were taken at 27$0^{\circ}C$. i-Butane permeance hardly changed after repeated thermal treatments up to 40$0^{\circ}C$, indicating the membrane is thermally stable. On the other hand, other single gas permeances increased when the membrane was further dried at 40$0^{\circ}C$, indicating thermal pretreatment at 27$0^{\circ}C$ could not remove all the adsorbed species in the membrane. i-Butane and SF$_{6}$ permeances were significantly lower than the permeances of smaller molecules, indicating that the membrane has a low concentration of defects. The ideal selectivities at 27$0^{\circ}C$ were 61 for $H_2$/i-butane and 47 for $H_2$/SF$_{6}$. The temperature dependency of n/i-butane ideal selectivities and separation factors for an equimolar n/i-butane mixture was studied. The ideal selectivity showed a maximum of 36 at 30$0^{\circ}C$. The separation factors increased with temperature and reached around 12 at 300-40$0^{\circ}C$, which were much higher than those reported in the literature.ature.

  • PDF

Efficacy of Fluoroscopy-Guided Cutting Needle Lung Biopsy in Patients with Diffuse Infiltrative Lung Disease (미만성 침윤성 폐질환을 보이는 환자에서 방사선투시유도 절단침 폐생검의 유효성)

  • Choi, Soo-Jeon;Shin, Eun-Ah;Kim, Joung-Sook
    • Tuberculosis and Respiratory Diseases
    • /
    • v.70 no.1
    • /
    • pp.43-50
    • /
    • 2011
  • Background: Open lung biopsy is used for diagnosis of diffuse infiltrative lung diseases (DILD), but it is invasive and relatively expensive procedure. Fluoroscopy-guided cutting needle lung biopsy (FCNLB) has merits of avoidance of admission and rapid diagnosis. But diagnostic accuracy and safety were not well known in the diagnosis of DILD. Methods: We included 52 patients (37 men, 15 women) having DILD on HRCT with dyspnea, except the patients who could be confidently diagnosed with clinical and HRCT findings. FCNLB was performed using 16G Ace cut needle (length 1.5 cm, diameter 2 mm) at the area of most active lesion on HRCT. Final diagnoses were made by the consensus. Results: The mean interval between the HRCT and FCNLB was 4.5 days. Most cases were performed one biopsy during 5~10 minutes. Specific diagnosis was obtained in 43 of 52 biopsies (83%). The most common diagnosis was nonspecific interstitial pneumonia (11 cases) and followed by cryptogenic organizing pneumonia (7 cases), diffuse alveolar hemorrhage and usual interstitial pneumonia (5 cases in each), hypersensitivity pneumonitis (3 cases), tuberculosis and drug induced interstitial pneumonitis (2 cases in each), the others are in one respectively. Mild complication was developed in 9 patients (8 pneumothorax, 1 hemoptysis). Most of complications were regressed without treatment except one case with chest tube insertion for pneumothorax. Conclusion: Fluoroscopy-guided 16 G cutting needle lung biopsy was an useful method for the diagnosis of DILD.

Material Design and Analysis of Coronary Artery Stents (관상동맥혈관용 스텐트의 구조해석과 재료설계)

  • Park, Joong-Gwun;Kang, Tae-Won;Lee, Kee-Sung;Kim, Tae-Woo
    • Journal of the Korean Ceramic Society
    • /
    • v.44 no.7
    • /
    • pp.362-367
    • /
    • 2007
  • Stent is a tiny structure made with either ceramic coating and/or bare metal. Being approximately $1{\sim}2 mm$ in diameter, it consists of holes, slots, or void space and is designed to cover entire medical lesions. Stent implantation into patients' arteries has been practiced for a little more than a decade in order to widen the blocked artery. The adoption of the stent has significantly improved the efficacy when compared with the previous medical practice by balloon angioplasty alone. Yet better biomedical performance of the stent is being demanded in order to eliminate the still existing problem of artery restenosis, which means the artery becomes narrowed again. Recent literature survey shows researches on ceramic coatings onto the stent surface, or material design to improve the mechanical response of the stent. This study focuses more on the material design and mechanical analysis. The results showed that the void configuration within the stent affects the mechanical response significantly. The rectangular shape was found to yield expansion at a relatively lower pressure than the elliptical slot for a slotted tube stent. The present results, when combined with research on coating at the stent surface, may provide stents with improved bio-medical performance.

Study on critical buckling load calculation method of piles considering passive and active earth pressure

  • Chen, Yong-Hui;Chen, Long;Xu, Kai;Liu, Lin;Ng, Charles W.W.
    • Structural Engineering and Mechanics
    • /
    • v.48 no.3
    • /
    • pp.367-382
    • /
    • 2013
  • Different types of long slender pile shall buckle with weak soil and liquefied stratum surrounded. Different from considering single side earth pressure, it was suggested that the lateral earth pressure can be divided into two categories while buckling: the earth pressure that prevent and promotes the lateral movement. Active and passive earth pressure calculation model was proposed supposing earth pressure changed linearly with displacement considering overlying load, shaft resistance, earth pressure at both sides of the pile. Critical buckling load calculation method was proposed based on the principle of minimum potential energy quoting the earth pressure calculation model. The calculation result was contrasted with the field test result of small diameter TC pile (Plastic Tube Cast-in-place pile). The fix form could be fixed-hinged in the actual calculation assuring the accuracy and certain safety factor. The contributions of pile fix form depend on the pile length for the same geological conditions. There exists critical friction value in specific geological conditions that the side friction has larger impact on the critical buckling load while it is less than the value and has less impact with larger value. The buckling load was not simply changed linearly with friction. The buckling load decreases with increased limit active displacement and the load tend to be constant with larger active displacement value; the critical buckling load will be the same for different fix form for the small values.