A Study on the Performance of Rotary Heat Exchanger using Aluminum Finned Copper Tube Heat Pipe (동관-알루미늄 휜 회전형 히트파이프 열교환기의 성능에 관한 연구)

  • Park, K.H.;Lee, K.W.;Lee, K.J.;Chun, W.P.
    • Proceedings of the KSME Conference
    • /
    • 2000.04b
    • /
    • pp.7-12
    • /
    • 2000
  • The purpose of this study is to develop heat transfer analysis program of heat pipe elements and design a revolving heat pipe exchanger by the performance experiment of hot air production by means of middle-temperature waste heat. Experimental variables are the revolution per minute, normal velocity of inlet air and the temperature of waste heat. The revolving heat exchanger has designed as $2^{\circ}$ in inclination angle of heat pipe bundle and as 20% in working fluid quantity and as water in working fluid. Experimental value of the total heat transfer coefficient was $20w/m^2-^{\circ}C$

  • PDF

A Study on the Boiling Heat Transfer of Heat Surface with Fin Array to R-113 (흰열이 있는 전열면의 R-113에서의 비등열전달에 관한 연구)

  • 조시기
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.6
    • /
    • pp.440-447
    • /
    • 2001
  • This study investigate experimentally the effect of in height, thickness, and clearance on the boiling heat transfer. The heat surfaces having copper fin array is tested for pool boiling. The gas-liquid exchange interference is investigated based on fin array clearance. These test results can be applied to the design of tube bundle system. The fin height of 2 mm is found to be effective. Effects of heat transfer promotion reaches the highest level when the fin clearance is 0.5mm. Also, heat flux is increased when the fin thickness is smaller. But0.2 mm fin thickness is highly recommended.

  • PDF

Conceptual Design and Wind Load Analysis of Tall Building

  • Lee, S.L.;Swaddiwudhipong, S.
    • Computational Structural Engineering : An International Journal
    • /
    • v.1 no.1
    • /
    • pp.11-20
    • /
    • 2001
  • The paper describes the conceptual design, structural modelling and wind load analysis of tall buildings. The lateral stiffness of the building can be obtained economically through the interaction of core walls with peripheral frame tube and/or bundle of frame tubes and integrated design of the basement. The main structural components should be properly distributed such that the building will deflect mainly in the direction of the applied force without inducing significant response in other directions and twist. The cost effectiveness can be further enhanced through close consultation between architects and engineers at an early stage of conceptual design. Simplified structural modelling of the building and its response in three principal directions due to wind load are included. Effects of the two main structural components on the performances of a 70-story reinforced concrete building in terms of peak drift and maximum acceleration under wind load are discussed.

  • PDF

Pressure Distribution over Tube Surfaces of Tube Bundle Subjected to Two-Phase Cross-Flow (이상 유동에 놓인 관군의 표면에 작용하는 압력 분포)

  • Sim, Woo Gun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.1
    • /
    • pp.9-18
    • /
    • 2013
  • Two-phase vapor-liquid flows exist in many shell and tube heat exchangers such as condensers, evaporators, and nuclear steam generators. To understand the fluid dynamic forces acting on a structure subjected to a two-phase flow, it is essential to obtain detailed information about the characteristics of a two-phase flow. The characteristics of a two-phase flow and the flow parameters were introduced, and then, an experiment was performed to evaluate the pressure loss in the tube bundles and the fluid-dynamic force acting on the cylinder owing to the pressure distribution. A two-phase flow was pre-mixed at the entrance of the test section, and the experiments were undertaken using a normal triangular array of cylinders subjected to a two-phase cross-flow. The pressure loss along the flow direction in the tube bundles was measured to calculate the two-phase friction multiplier, and the multiplier was compared with the analytical value. Furthermore, the circular distributions of the pressure on the cylinders were measured. Based on the distribution and the fundamental theory of two-phase flow, the effects of the void fraction and mass flux per unit area on the pressure coefficient and the drag coefficient were evaluated. The drag coefficient was calculated by integrating the measured pressure on the tube by a numerical method. It was found that for low mass fluxes, the measured two-phase friction multipliers agree well with the analytical results, and good agreement for the effect of the void fraction on the drag coefficients, as calculated by the measured pressure distributions, is shown qualitatively, as compared to the existing experimental results.

Acrosome Morphogenesis in Gerris paludum (Heteroptera) (소금쟁이의 尖體形成)

  • Lee, Young-Hwan;Lee, Chang-Eon
    • The Korean Journal of Zoology
    • /
    • v.24 no.2
    • /
    • pp.65-75
    • /
    • 1981
  • The formation of the acrosome during spermatogenesis in Gerris paludum was studied. The Golgi bodies are dispersed randomly in the cytoplasm at the early stage of the spermatocyte and get together to form several group of many bodies, and then they are equally divided into the spermatids by the meiotic divisions. The acroblast first appears in the form of a vesicle and soon an acrosomal granule is differentiated within it. The acroblast is separated from the acrosomal granule at the posterior of the nucleus and is finally sloughed off along the tail filament. The acrosome, after moving to the side of the nucleus opposite the mitochondrial derivatives, differentiates into two zones. The two basal bodies and the differentiated tip originate from the sheath. The basal bodies appear at the proximal part of the sheath simply in contact with the core on one side. During elongation and and narrowing of the acrosomes of the spermatids, they surround the one side at the base of the acrosome and finally all the other are immediately adjacent to the nucleus. The differentiated tip continues to the sheath at the anterior of the cores and is elongated prior to the two basal bodies. They appear to be contiguous twin-tubes, not a single granule in the later stage of the spermatids, and a group of the basal bodies in the sperm bundle.

  • PDF

Stress Day Index to Predict Soybean Yield Response by Subsurface Drainage in Poorly Drained Sloping Paddy Fields (배수불량 경사지 논에서 배수개선에 따른 콩의 수분스트레스 반응해석)

  • Jung, Ki-Yuol;Yun, Eul-Soo;Park, Chang-Young;Hwang, Jae-Bok;Choi, Young-Dae;Park, Ki-Do
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.44 no.5
    • /
    • pp.702-708
    • /
    • 2011
  • There are considerable areas of wet paddy fields in Korea that requires improvement of its drainage system. In poorly drained sloping paddy fields, upland crops can be damaged by either rainfall or capillary rise of the water table caused by percolating water beneath the upper fields during summertime rainy season. The purpose of this study is to evaluate excess water stress of soybean yield by drainage systems. Four drainage methods namely open ditch, vinyl barrier, pipe drainage and tube bundle were installed within 1-m position at the lower edge of the upper paddy fields. Stress Day Index (SDI) approach was developed to quantify the the cumulative effect of stress imposed on a soybean yield throughout the growing season. SDI was determined from a stress day factor (SD) and a crop susceptibility factor (CS). The stress day factor is a measure degree and duration of stress of the ($SEW_{30}$). The crop susceptibility factor (CS) depends of a given excess water on crop stage. The results showed that SDI used to represent the moisture stress index was most low on the pipe drainage 64.75 compared with the open ditch 355.4, vinyl barrier 271.55 and tube bundle 171.55. Soybean grain yield increased continuously with the rate of 3% in Vinyl Barrier, 32% in Pipe Drainage and 16% in Tube Bundle.

Effect of Transverse Convex Curvature on Turbulent Fluid Flow in Fuel Channel (핵연료 수로내 난류 유동에 대한 횡방향 볼록구배의 영향)

  • Lee, Yung;Ahn, Seung-Hoon;Kim, Hyong-Chol
    • Nuclear Engineering and Technology
    • /
    • v.26 no.3
    • /
    • pp.440-452
    • /
    • 1994
  • Nuclear fuel bundles are designed such that the heat flux at a-fuel pin surface should not exceed the critical heat flux (CHF) during normal operation and anticipated transient. Therefore, evaluation of the CHF for fuel bundle is demanded in an exact and reliable manner. One of the major concerns with the current application of CHF correlations is that the CHF based on circular tubes is applied to the fuel bundle subchannel analysis, mainly in terms of the hydraulic diameter with correction factors which may result in a source of possibly large uncertainties in CHF prediction. The hydraulic diameter does not recognize the local properties of fluid nor such effect as the surface curvature; the turbulence action on the convex surface is much more pronounced than that on the concave surface. Even for the tube having concave curvature, the effect of tube diameter on CHF becomes important with decreasing diameter. These facts imply that the convex curvature effect is significant and crucial to the reliable CHF prediction. This paper reviews and discusses analytical and experimental aspects of effect of transverse convex curvature in incompressible turbulent flow and heat transfer, and on CHF. Flow models to quantify this effect are briefly mentioned and future works are recommended.

  • PDF

Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2010 (설비공학 분야의 최근 연구 동향 : 2010년 학회지 논문에 대한 종합적 고찰)

  • Han, Hwa-Taik;Lee, Dae-Young;Kim, Seo-Young;Choi, Jong-Min;Kim, Su-Min;Kwon, Young-Chul;Baik, Yong-Kyu
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.6
    • /
    • pp.449-469
    • /
    • 2011
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigerating Engineering during 2010. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) Research trends of thermal and fluid engineering have been surveyed as groups of general thermal and fluid flow, fluid machinery, and new and renewable energy. Various topics were presented in the field of general thermal and fluid flow. Research issues mainly focused on the thermal reliability of axial fan and compressor in the field of fluid machinery. Studies on the design of ground source heat pump systems and solar chemical reactors were executed in the field of new and renewable energy. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics and industrial heat exchangers. Researches on heat transfer characteristics included heat transfer in thermoelectric cooling/power generation systems, combined heat and power systems, carbon nano fluid with PVP, channel filled with metal foam and smoke ventilation in a rescue station of a railroad tunnel. Also the studies on flow boiling of R123/oil mixture in a plain tube bundle and R410A charge amount in an air cooled mini-channel condenser were reported. In the area of industrial heat exchangers, researches on plate heat exchanger, shell and tube heat exchanger, enthalpy exchanger, micro channel PCHE were performed. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics and industrial heat exchangers. Researches on heat transfer characteristics included heat transfer in thermoelectric cooling/power generation systems, combined heat and power systems, carbon nano fluid with PVP, channel filled with metal foam and smoke ventilation in a rescue station of a railroad tunnel. Also the studies on flow boiling of R123/oil mixture in a plain tube bundle and R410A charge amount in an air cooled mini-channel condenser were reported. In the area of industrial heat exchangers, researches on plate heat exchanger, shell and tube heat exchanger, enthalpy exchanger, micro channel PCHE were performed. (3) Refrigeration systems with alternative refrigerants such as hydrocarbons, mixed refrigerants, and CO2 were studied. Performance improvement of refrigeration systems are tried applying various ideas of refrigerant subcooling, dual evaporator with hot gas bypass control and feedforward control. The hybrid solar systems combining the solar collection devices with absorption chillers or compression heat pumps are simulated and studied experimentally as well to improve the understanding and the feasibility for actual applications. (4) Research trend in the field of mechanical building facilities has been found to be mainly focused on field applications rather than performance improvements. Various studies on heating and cooling systems, HVAC facilities, indoor air environments and energy resources were carried to improve the maintenance and management of building service equipments. In the field of heating and cooling systems, papers on a transformer cooling system, a combined heat and power, a slab thermal storage and a heat pump were reported. In the field of HVAC facilities, papers on a cooling load, an ondol and a drying were presented. Also, studies on HVAC systems using unutilized indoor air environments and energy resources such as air curtains, bioviolence, cleanrooms, ventilation, district heating, landfill gas were studied. (5) In the field of architectural environment and energy, studies of various purposes were conducted such as indoor environment, building energy, renewable energy and green building. In particular, renewable energy and building energy-related researches have mainly been studied reflecting the global interest. In addition, many researches which related the domestic green building certification of school building were performed to improve the indoor environment of school.

Experimental Study on Heat Transfer Performance of Plate Type Absorber with Variation of Solution Flow Rate (용액유량에 따른 플레이트 흡수기의 흡수 열전달 특성 실험)

  • Moon, C.G.;Bang, G.S.;Kim, J.D.;Yoon, J.I.
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.1548-1553
    • /
    • 2003
  • An experimental study of the absorption process of water vapor into a lithium bromide solution was performed. For the purpose of development of high performance absorption chiller/hater utilizing lithium bromide solution as working fluid, it is the most effective to improve the performance of absorber with the largest heat transfer area of the four heat exchangers. The experimental apparatus was composed of a plate type absorber which can increase the heat exchange area per unit volume to investigate more detail characteristics instead of the conventional type, horizontal tube bundle type. The size of plate absorbers were made for $0.4m{\times}0.6m$ and the design object of a refrigeration capacity was lRT. In this experiment, three kind plate absorbers which were flat plate, dimple plate and groove plate were used. The results were less than the design object values, that is, the refrigeration capacity was about $0.3{\sim}0.4RT$ and the overall heat transfer coefficient was $500{\sim}600kcal/m^2h^{\circ}C$ at the standard conditions.

  • PDF

Simulation of Water/steam into Sodium Leak Behavior for an Acoustic Noise Generation Mechanism Study

  • Kim, Tae-Joon;Hwang, Sung-Tai;Jeong, Kyung-Chai;Park, Jong-Hyeun;Valery S. Yughay
    • Nuclear Engineering and Technology
    • /
    • v.33 no.2
    • /
    • pp.145-155
    • /
    • 2001
  • This simulation first allows us to define a transition zone from a bubble to jet mode of the argon out-flow and hereinafter to define a similar area for water-steam leak in the KALIMER SG (Korea Advanced Liquid Metal Reactor Steam Generator) using a water mock-up system, taking into account the KALIMER leak classification and tube bundle design, as a simulation of a real water-steam into sodium leak. in accordance with leak conditions in the KALIMER SG, the transition from bubbling to jetting is studied by means of turbulence regime simulation for argon out-flow through a very small orifice, which has the equivalent diameter of about 0.253 mm. finally the noise generation mechanism is explained from the existing experimental data. We also confirmed the possibility of micro-leak detection from the information of the bubbling mode through simulations and the experiment in this study.

  • PDF