• 제목/요약/키워드: Tube Bank

검색결과 55건 처리시간 0.022초

수평식 셸-튜브형 잠열축열조의 축열 및 방열특성에 관한 실험적 연구 (An Experimental Study on Heat Storage and Heat Recovery Characteristics of a Latent Heat Storage Tank with Horizontal Shell and Tube Type)

  • 권영만;서해성;모정하
    • 대한기계학회논문집B
    • /
    • 제24권1호
    • /
    • pp.50-59
    • /
    • 2000
  • An experimental study has been carried out in order to investigate the heat storage characteristics for a latent heat storage tank with horizontal shell and tube type. The heat exchanger consisted of horizontal cylindrical capsules with a staggered tube bank layout. Based on the obtained data, the effects of flow rate and inlet fluid temperature on the melting time and heat storage rates were examined. It is found that the melting time decreased with increase of the flow rate and the inlet temperature. Results also show that at the initial stage of heat transfer the heat storage rate represents the maximum value and rapidly decreases.

셀-튜브형 잠열축열조의 축열특성에 관한 연구 (A Study on the Heat Storage Characteristics of a Latent Heat Storage Tank with Shell and Tube Type)

  • 권영만;김경우;모정하
    • 설비공학논문집
    • /
    • 제12권8호
    • /
    • pp.745-754
    • /
    • 2000
  • An experimental study has been carried out in order to investigate the heat storage characteristics for a latent heat storage tank with horizontal shell and tube type. The heat storage tank consists of cylindrical capsules with a staggered tube bank. The effects of flow rates and initial temperature differences on the melting time and heat storage rates are examined. It is found that the melting time decreases with increase of the flow rates and initial temperature differences. Results also show that the time-averaged overall heat transfer coefficients increase in proportion to the increase of flow rates and initial temperature differences.

  • PDF

보일러 튜브군의 음향공진 회피를 위한 음향배플의 위치에 따른 FEM 음향모드해석 (FEM acoustic modal analysis due to location of acoustic baffles to avoid acoustic resonance in the tube bank of boiler for power plant)

  • 안성종;주영호;김철홍
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2012년도 춘계학술대회 논문집
    • /
    • pp.150-154
    • /
    • 2012
  • A flow induced mechanical vibration and acoustic resonance should be considered at design stage because they are mainly occurred in the tube bank of boiler. Acoustic resonance is occurred when the vortex shedding frequency of tube bank coincides with the acoustic natural frequency of the cavity. Effective solution to avoid acoustic resonance is installing acoustic baffles in the tube banks parallelly inside of the flow cavity. Thus, location and number of acoustic baffles should be exactly calculated to eliminate the acoustic resonance. This paper presents case study of acoustic resonance due to inappropriate number and location of acoustic baffles. Measured frequency and mode in the study is verified by FEM acoustic modal analysis. The number and location of acoustic baffles to avoid acoustic resonance are calculated by using FEM acoustic modal analysis.

  • PDF

스크린을 이용한 직교류 열교환기의 열전달 촉진에 관한 연구 (An Experimental Study on Heat Transfer Enhancement of Cross Flow Heat Exchanger Using Screen)

  • 유성연;장광일;권화길
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2007년도 동계학술발표대회 논문집
    • /
    • pp.185-190
    • /
    • 2007
  • For the successful design of heat exchangers, it is very important to understand local heat transfer characteristics on the circular cylinder of the cross flow heat exchangers. In this study, the heat exchanger using screen is developed to enhance heat transfer. The naphthalene sublimation technique is employed to measure the local heat transfer coefficients in the heat exchanger. The experiments are performed for single circular tube, in-line array tube bank with and without heat transfer promoter. Local Nusselt numbers of single circular tube and tube bank with heat transfer promoter are investigated and compared to those of without heat transfer promoter.

  • PDF

안내덕트 내부 난류유동구조에 따른 열전달 특성변화 수치해석 (Numerical Study on Heat Transfer Characteristics of Turbulent Flow in Transition Duct)

  • 유근종;최훈기;최기림
    • 대한기계학회논문집B
    • /
    • 제35권9호
    • /
    • pp.923-932
    • /
    • 2011
  • 본 연구에서는 복합화력발전소 가스터빈 출구가스 안내덕트 내부의 가스유동장이 배열회수보일러 전열기구에 미치는 영향을 CFD기법을 이용하여 분석하였다. 안내덕트 내부 난류흐름의 경우, 유속의 편차가 크고 선회 효과 및 상승류 현상이 심한 특징을 가지고 있음으로 이와 같은 유동의 수치해석을 위해 2개 방정식 난류점성 모델 중 RNG k-${\epsilon}$ 모델을 사용하였으며 유동장의 영향을 가장 많이 받는 배열 회수보일러 최종과열기관의 열전달특성변화를 파악하기 위하여 NTU 방식을 이용한 수치해석결과와, 산업계에서 적용하는 설계기법에 의한 결과를 비교하였다.

순환 유동층 보일러 관군의 음향공진에 의한 이상소음 발생 및 저감 연구 (A study on the reduction of noise and vibration by acoustic resonance in the tube bank of a circulating fluidized bed combustion boiler)

  • 박응규;송근복;김원현;주원호
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2011년도 추계학술대회 논문집
    • /
    • pp.101-106
    • /
    • 2011
  • In the present paper, the phenomena of abnormal noise and vibration due to acoustic resonance of CFBC(Circulating Fluidized Bed Combustion) boiler was presented. The acoustic resonance which occurred in the gas path of CFBC boiler system was caused by coincidence of vortex shedding frequency of tube bank and acoustic natural frequency of duct and hopper. And, the phenomena of beating arose from the interference of two closed resonant waves at 66.4Hz and 70.8Hz. There are two control methods for acoustic resonance in this system. The first method is to change the vortex shedding frequency from the structural alterations on the tube bank. And the second method is to change the acoustic natural frequency of the gas path with the installation of anti-noise baffles. The second one which is relatively easy to apply, was adapted in this study. As a result, the noise and vibration level have been decreased by 41dB and 94% at 66.4Hz, respectively. And the improvement of noise and vibration at 70.8Hz was identified by sensory evaluation.

  • PDF

직렬 관군에서 지열수스케일의 파울링 영향에 관한연구 (A Study on the Fouling Effect of Geothermal Water Scale in In-line tube Bank)

  • 윤석범
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제23권2호
    • /
    • pp.131-139
    • /
    • 1999
  • An experimental study was conducted to investigate the fouling effects of geothermal water scale deposited onto a heating surface upon its forced convection heat transfer characteristics. Scales deposited onto the heating surfaces of heat exchangers seriously reduce the heat transfer perfor-mance and also increase the hydrodynamic drag. Accordingly fouling is an important problem in the design and operation of heat exchangers. The cylinders were settled in tandem with equal dis-tance between neighbouring cylinders and only the test cylinder was heated under the condition of constant heat flux. The Reynolds number was varied from 13000310 through 50003100. It is found that the heat transfer of the in-line tube banks greatly varies with the fouling of geothermal water scale especially its scale height. Further the local and average Nusselt numbers strongly depend upon the cylinder spacing and the Reynolds number.

  • PDF

엇갈림 관군에서 원관 주위의 열전달에 미치는 파울링 영향에 관한 실험적 연구 (An Experimental Study of Fouling Effect on the Heat Transfer Around a Tube in Staggered Tube Banks)

  • 김민수;백병준;박복춘
    • 대한기계학회논문집B
    • /
    • 제24권11호
    • /
    • pp.1478-1485
    • /
    • 2000
  • An experimental study has been performed to investigated the forced convection heat transfer characteristics of 6 circular cylinders in staggered arrangement in a cross flow of air. The water scale deposited on condenser wall of power plant was used to investigate the effect of roughness of scaled surfaces. The relative roughness*average diameter of scale/cylinder diameter) was in a range of k/d=0.0066, 0.0111, 0.0167, 0.0222 and 0.0278. The cylinder spacings(L/d) varies from 1.5 to 4.0 where L denote the cylinder spacings along and normal to the upstream uniform flow direction. The Reynolds number was varied in a range of 10, 000$\leq$ Re $\leq$ 50,000. The local and mean Nusselt numbers were investigated as a function of scale roughness, the cylinder spacing and Reynolds number. The results are compared with those of clean cylinder and inline tube bank, subsequently the mean fouling resistance over the entire circumference was estimated from those results as a function of scale roughness, the cylinder spacing and Reynolds number.

관군 열교환기에서 균일 자기장에 의한 전기 전도성 유체의 열유동 특성에 관한 수치해석 연구 (Numerical Study of Thermo-Fluid Features of Electrically Conducting Fluids in Tube Bank Heat Exchangers Exposed to Uniform Magnetic Fields)

  • 오진호;강남철;박일석
    • 대한기계학회논문집B
    • /
    • 제41권10호
    • /
    • pp.659-665
    • /
    • 2017
  • 본 연구에서는 엇갈림 배열 관군 사이를 전기 전도성 유체가 흐를 때 외부에서 인가한 자기장의 영향으로 변화하는 열유동 특성을 수치해석적으로 연구하였다. Reynolds 수 50과 100의 비정상 층류 관군 유동에서 외부 인가 자기장의 세기를 의미하는 Hartmann 수를 0에서 100까지 점진적으로 변화시킴에 따라 관군 내부의 열유동 특성을 관찰하였다. Hartmann 수가 증가함에 따라 인가 자기장의 영향으로 관표면의 속도 경계층이 얇아지고, 유동 박리를 후류로 지연시키며, 관 후면에 형성되는 재순환 영역의 크기가 줄어드는 것을 관찰하였다. 최종적으로 열유동 변형에 의한 결과적 국소 및 평균 Nusselt 수 변화 특성을 제시하였다.

배열회수장치의 유동특성에 관한 수치적 연구 (NUMERICAL STUDY ON FLOW CHARACTERISTIC IN THE HEAT RECOVERY STEAM GENERATOR)

  • 최훈기;유근종;신병주;김철환
    • 한국전산유체공학회지
    • /
    • 제15권1호
    • /
    • pp.17-23
    • /
    • 2010
  • Performance improvements of the heat recovery steam generator(HRSG) can be achieved by improving the flow distribution of exhaust gases for a various type of different equipments. A number of design parameters are systematically investigated and their effects on an index of velocity deviation established. The parameters include the three shape of the transition duct and the wide range of the guide vane angles. The numerical results clearly reveal feature of the flow pattern in the transition duct, velocity deviation and pressure drop at tube bank part.