• Title/Summary/Keyword: True

Search Result 5,107, Processing Time 0.035 seconds

The Computation of True Thrust Using only the Measured Thrust (측정된 추력 데이터만을 이용한 실제 추력의 계산)

  • Kim Jun-Yeop
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.8 no.4
    • /
    • pp.9-15
    • /
    • 2004
  • The measured thrust could be distorted because of the transient response of thrust stand during combustion of rocket motor. As a result of the distorted thrust, it is not easy for us to know the values of thrust peak and thrust duration time. Therefore, it is of great importance to compute the true thrust from the measured thrust. In this study the method to eliminate the transient response from the measured thrust using only the measured thrust was Proposed, and also experimental data were used to approve the proposed method. The result showed that the proposed method would be available to compute the true thrust.

Bi-linear Stress-Strain Curves for Considering Cyclic Hardening Behavior of Materials in the Nonlinear FE Analysis under Seismic Loading Conditions (지진하중 조건의 비선형 유한요소해석에서 반복경화 거동 고려를 위한 Bi-linear 응력-변형률 곡선)

  • Jeong, Hyun Joon;Kim, Jin Weon;Kim, Jong Sung;Koo, Gyeong Hoi
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.14 no.2
    • /
    • pp.59-68
    • /
    • 2018
  • This study compares true stress-true strain curves obtained by tensile tests of various piping materials with bi-linear stress-strain approximation suggested in the JSME Code Case(CC) Draft, a guideline for piping seismic inelastic response analysis. Based on the comparisons, the reliability of the bi-linear approximation is evaluated. It is found that bi-linear stress-strain curve of TP316 stainless steel is in good agreement with its true stress-true strain curve. However, Bi-linear stress-strain curves of TP304 stainless steel and carbon steels determined by the approximation cannot appropriately estimate their stress-strain behavior. Accordingly new bi-linear approximations for carbon steels and low-alloy steels are proposed. The proposed bi-linear approximations for carbon and low-alloy steels, which include the temperature effect on strength and hardening of material, estimate their stress-strain behavior reasonably well.

A Study on the Deduction of the Concept of Mingmen(命門) as the Monarch of the Body (『의관(醫貫)』에서 명문진군(命門眞君) 개념의 도출(導出)에 대한 고찰)

  • Eun, Seok-min
    • Journal of Korean Medical classics
    • /
    • v.34 no.4
    • /
    • pp.79-93
    • /
    • 2021
  • Objectives : This study analyzes the theoretical and clinical reasoning process of Zhao Xian-Ke that argued that the Mingmen is the true monarch of the body. Methods :The analysis focuses on how the arguments of Li Dong-yuan and Zhu Danxi was succeeded and supplemented by Zhao Xian-Ke into a new theoretical system in the Yiguan(醫貫). Results & Conclusions : Zhao's argument that the Mingmen is the true monarch of the body is a result of emphasis on the meaning of innate Qi that is separate from the Water and Fire of the Heart and Kidney, which is derived from the innate Qi concept of Li Dong-yuan's Spleen-Stomach Theory. Zhu Danxi's Ministerial Fire Theory was also accepted through the innate Qi concept of Ministerial Fire and True Yin, which contributed to the establishment of a systematical theory on Mingmen, Miniterial Fire, and True Yin as constituents of innate Qi. In conclusion, the Neijing's explanation that the Heart radiates Shenming as the monarch organ has been modified into innate Qi from the Mingmen reaching the Heart to radiate Shenming.

A case of true thymic hyperplasia in the mediastinum with ectopic thymus in the neck (종격동 진성 흉선 증식증에 동반된 경부 이소 흉선 1례)

  • Kim, Hyun-Jung;Jang, Sun-Hwa;Park, Ji-Sook;Park, Eun-Sil;Seo, Ji-Hyun;Lim, Jae-Young;Park, Chan-Hoo;Woo, Hyang-Ok;Youn, Hee-Shang
    • Clinical and Experimental Pediatrics
    • /
    • v.49 no.9
    • /
    • pp.996-999
    • /
    • 2006
  • True thymic hyperplasia and ectopic thymus are very rare in children. In embryologic aspect, thymus is distributed around cervical area and ends up in mediastinum. This case is simultaneous thymic hyperplasia of neck and mediastinum. Ectopic thymus in the neck and thymic hyperplasia in the mediastinum in children were reported 2 and 7 cases respectively in Korea. In Clinical aspects, these thymic hyperplasia were presented by mass. So we should suspect these benign condition to avoid unnecessary operation or biopsy. We report a case of true thymic hyperplasia in the mediastinum with ectopic thymus in the neck in a 4-month-old male infant and review the relevant literature. We believe this is the first reported case in the world of true thymus hyperplasia in the mediastinum with cervical ectopic thymus in the neck.

Preparation and Oxygen Permeability of True-IPN's based on Silicone Rubber and Polystyrene (실리콘 고무와 폴리스틸렌을 이용한 True-IPNs의 제조 및 산소투과 특성)

  • Kim, Jun-Hyun;Byun, Hong-Sik
    • Membrane Journal
    • /
    • v.10 no.4
    • /
    • pp.205-212
    • /
    • 2000
  • The true-lPN's based on silicone rubber(SR)rrubbery polymer) and polystyrenc(PS)(glass polymer) were prepared by using the sequential IP!\' method_ The characteristic of permeability of oxygen/nitrogen was investigated with the control of the amount of PSOO-70 wt%) in the true-lPN, As a results of fTlR and N1Vm. the SRIPS membrane was synthesised successfully with the IPN synthetic method, Thermal analysis resulls indicated that the degree of mixing of IPN increased with increase of the amount of PS in the IPN. Regarding the characteristic of gas permeability, the membrane showed a trend of decrease in oxygen permeability as the PS content increased, The oxygen permeability of membrane having 50 wt% of PS. however, increased momentarily, Selectivity, meanwhile, increased slightly as the contents of I'S increased. However, the maximum value of oxygen selectivity, which is 20.6% enhanced Value, was obtained with the membrane containing 50 wt% of PS. This can be explained that the behavior of lPN, i.e. mutual assistance, is pronounced in the membrane having 50 wt% of PS.

  • PDF

Study on Estimating the Optimal Number-right Score in Two Equivalent Mathematics-test by Linear Score Equating (수학교과의 동형고사 문항에서 양호도 향상에 유효한 최적정답율 산정에 관한 연구)

  • 홍석강
    • The Mathematical Education
    • /
    • v.37 no.1
    • /
    • pp.1-13
    • /
    • 1998
  • In this paper, we have represented the efficient way how to enumerate the optimal number-right scores to adjust the item difficulty and to improve item discrimination. To estimate the optimal number-right scores in two equivalent math-tests by linear score equating a measurement error model was applied to the true scores observed from a pair of equivalent math-tests assumed to measure same trait. The model specification for true scores which is represented by the bivariate model is a simple regression model to inference the optimal number-right scores and we assume again that the two simple regression lines of raw scores and true scores are independent each other in their error models. We enumerated the difference between mean value of $\chi$* and ${\mu}$$\_$$\chi$/ and the difference between the mean value of y*and a+b${\mu}$$\_$$\chi$/ by making an inference the estimates from 2 error variable regression model. Furthermore, so as to distinguish from the original score points, the estimated number-right scores y’$\^$*/ as the estimated regression values of true scores with the same coordinate were moved to center points that were composed of such difference values with result of such parallel score moving procedure as above mentioned. We got the asymptotically normal distribution in Figure 5 that was represented as the optimal distribution of the optimal number-right scores so that we could decide the optimal proportion of number-right score in each item. Also by assumption that equivalence of two tests is closely connected to unidimensionality of a student’s ability. we introduce new definition of trait score to evaluate such ability in each item. In this study there are much limitations in getting the real true scores and in analyzing data of the bivariate error model. However, even with these limitations we believe that this study indicates that the estimation of optimal number right scores by using this enumeration procedure could be easily achieved.

  • PDF

Endovascular Stent Placement in a Patient with a Posttraumatic Isolated Superior Mesenteric Artery Dissection with Focally Progressing Dissecting Aneurysms and a Severely Compressed True Lumen (외상 후 단독 상장간막동맥박리 후에 국소적으로 진행된 박리성 동맥류와 심한 진강의 압박이 있는 환자에서 혈관내 스텐트설치술 1례)

  • Kim, Young-Kyu;Her, Kyu Hee;Kim, Seung Hyoung;Kim, Kwangsik
    • Journal of Trauma and Injury
    • /
    • v.28 no.4
    • /
    • pp.266-271
    • /
    • 2015
  • Reports on a posttraumatic isolated superior mesenteric artery (SMA) dissection are rare. Recently, endovascular stent placement via percutaneous access, instead of vascular surgery, has been widely accepted as the initial treatment for a patient with an isolated SMA dissection or its complications. A 60-year-old female patient was transferred to our hospital due to an isolated SMA dissection after a car accident. The SMA dissection was 8.5 cm in length, and it involved the true lumen, which was severely compressed by the thrombosed false lumen. The patient was closely observed because she did not complain of any specific visceral pain. On the seventh hospital day, she underwent computed tomography (CT) to decide on a further treatment plan, irrespective of the presence of the abdominal symptom. The findings of the follow-up CT showed no difference compared to those of the previous CT. She was discharged with anti-coagulants. One month later, the follow-up CT revealed focally progressing dissecting aneurysms in the false lumen of the dissected SMA and a more severely compressed true lumen. Two self-expandable metallic stents were successfully placed in the true lumen of the dissected SMA, covering two aneurysmal lesions. Herein, we report a successful endovascular treatment with stent placement for treating focally progressing dissecting aneurysms and a severely compressed true lumen in a patient with a posttraumatic isolated SMA dissection.

  • PDF

An Analysis of Factors that Affect Spinal Scoliosis of College Students (일부 대학생의 척추 측만에 영향을 미치는 요인 분석)

  • Hwang, Hyun-Sook
    • PNF and Movement
    • /
    • v.7 no.2
    • /
    • pp.1-10
    • /
    • 2009
  • This research measures the conditions of spinal scoliosis of college students and analyses the factors that affect spinal scoliosis. From September 15, 2008 to October 30, 2008, the study was conducted with 142 C College students and measured the degrees of spinal scoliosis. The analysis was evaluated according to the Pneumex Analysis program. The collected data was compiled into statistics using the SPSS PC+ 12.0 program. The results were as follows: 1. It appeared that in the cases of C curve, reverse C curve, S curve, and the normal, there was a statistical significance(p=.010) between the conditions of spinal scoliosis of the two genders. 2. It appeared that the comparison among the three groups according to the characteristics of the subjects showed a statistical significance in spinal length(p=.000) in the C curve group, age(p=.019) and spinal length(p=.004) in the reverse C curve group, and spinal length (p=.035), difference in apparent leg length(p=.019), and difference in true leg length(p=.012) in the S curve group. 3. It appeared that in the normal group without spinal scoliosis, the results of comparing the differences in apparent true leg length and spinal length according to the characteristics of the subjects showed a statistical significance in spinal length and gender(p=.000), age (p=.008), height(p=.000), and whether or not there was a regular exercise over once per week(p=.001). 4. On the correlations between C curve, reverse C curve, and S curve and differences in apparent true leg length and spinal length, it appeared that: (a) As the difference in apparent leg length gets bigger the difference in true leg length gets big in C curve(r=.551, p=.000). (b) As the difference in apparent leg length gets bigger the difference in true leg length gets big in reverse C curve(r=.511, p=.006). (c) There is no correlation in S curve.

  • PDF

The maxillary incisor labial face tangent: clinical evaluation of maxillary incisor inclination in profile smiling view and idealized aesthetics

  • Naini, Farhad B.;Manouchehri, Shaadi;Al-Bitar, Zaid B.;Gill, Daljit S.;Garagiola, Umberto;Wertheim, David
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.41
    • /
    • pp.31.1-31.7
    • /
    • 2019
  • Background: To test the hypothesis that in profile smiling view, for ideal aesthetics, a tangent to the labial face of the maxillary central incisor crowns should be approximately parallel to the true vertical line and thereby perpendicular to the true horizontal line. Methods: An idealized female image was created with computer software and manipulated using the same software to construct an "ideal" female profile image with proportions, and linear and angular soft tissue measurements, based on currently accepted criteria for idealized Caucasian profiles. The maxillary incisor labial face tangent was altered in 5° increments from 70 to 120°, creating a range of images, shown in random order to 70 observers (56 lay people and 14 clinicians), who ranked the images from the most to the least attractive. The main outcome was the preference ranks of image attractiveness given by the observers. Results: The most attractive inclination of a tangent to the labial face of the maxillary incisor crowns in profile view in relation to the true horizontal line was 85°, i.e. 5° retroclined from a perpendicular 90° inclination. The most attractive range appears to be between 80 and 90°. Excessive proclination appeared to be less desirable than retroclination. Beyond 105° most observers recommend treatment. Conclusion: In natural head position, the ideal inclination of the maxillary incisor crown labial face tangent in profile view will be approximately parallel to the true vertical line and thereby approximately perpendicular to the true horizontal line.

Variation of Elastic Stiffness of Polydimethylsiloxane (PDMS) Stretchable Substrates for Wearable Packaging Applications (웨어러블 패키징용 Polydimethylsiloxane (PDMS) 신축성 기판의 강성도 변화거동)

  • Choi, Jung-Yeol;Park, Dae-Woong;Oh, Tae Sung
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.21 no.4
    • /
    • pp.125-131
    • /
    • 2014
  • In order to develop stretchable substrates for wearable packaging applications, the variation behavior of elastic modulus was evaluated for transparent PDMS Sylgard 184 and black PDMS Sylgard 170 as a function of the base/curing agent mixing ratio. Both for Sylgard 184 and Sylgard 170, the true elastic modulus evaluated on a true stress-true strain curve was higher more than two times compared to the engineering elastic modulus obtained from an engineering stres-sengineering strain curve, and their difference became larger with increasing the stiffness of the PDMS. Sylgard 184 exhibited a maximum engineering elastic modulus of 1.74 MPa and a maximum true elastic modulus of 3.57 MPa at the base/curing agent mixing ratio of 10. A maximum engineering elastic modulus of 1.51 MPa and a maximum true elastic modulus of 3.64 MPa were obtained for Sylgard 170 at the base/curing agent mixing ratio of 2.