A Study on the High Speed Breaking of Parallel Arcing (병렬아크의 고속 차단에 관한 연구)

  • Kim, Il-Kwon;Ji, Hong-Keun;Kim, Sung-Uk;Park, Dae-Won;Kil, Gyung-Suk
    • Proceedings of the KSR Conference
    • /
    • 2008.06a
    • /
    • pp.327-331
    • /
    • 2008
  • This paper dealt with high speed breaking method to parallel arcing in low-voltage systems. The proposed high speed breaking circuit consists of a Rogowski coil and an integrator, and operates with an earth leakage circuit breaker (ELCB). A parallel arcing state was simulated by a short circuit using stripped wires. In this test, we analyzed tripping characteristics of the circuit breaker by the length of wires from 5m to 30m. From the experimental results, we confirmed that the proposed method can break the parallel arcing within a few millisecond.

  • PDF

Control Strategy against Undesirable Zone 3 Relay Operation in Voltage Instability

  • Lee Byong-Jun;Song Hwa-Chang
    • KIEE International Transactions on Power Engineering
    • /
    • v.5A no.2
    • /
    • pp.144-151
    • /
    • 2005
  • This paper presents a framework for determining control strategies against unwanted tripping actions during relay operation that plays a very important role in cascading events leading to voltage collapse. The framework includes an algorithm for quick identification of possible zone 3 relay operation during voltage instability. Furthermore, it comes up with the control strategy of load shedding at the selected location with active power and relay margin criteria. In addition, Quasi Steady-State (QSS) simulation is employed to obtain time-related information that is valuable in the determination of control strategy. As a case study, an example applying the framework is shown with the modified New England 39-bus system.

A Study on the Modification of Frequency Detection Methode for Cheju-Heanam HVDC System (제주-해남 HVDC 시스템의 주파수 검출방식 변경에 관한 연구)

  • Park, Jong-Kwang;Kim, Chan-Ki;Yang, Byoung-Mo
    • Proceedings of the KIPE Conference
    • /
    • 2005.07a
    • /
    • pp.176-178
    • /
    • 2005
  • In this paper deals with the frequency control of the HVDC scheme linking Haenam to Cheju Island. The primary aim of the study is to develop and evaluate a new frequency control that can be employed without having to utilize the existing Synchronous Compensators(Gas Turbines). Study cases are completed involving synchronous compensators trip and load tripping events and study plots presented. It is demonstrated that the existing frequency measurement can be replaced by one derived from the AC network alone, incorporated into a new frequency control algorithm and gives good frequency control and dynamic performance.

  • PDF

The Transient Analysis of Instant Short-Circuit Test Equipment For Earth Leakage Circuit Breaker (IEC60947-2에 따른 누전차단기의 순시단락시험 과도현상에 대한 연구)

  • Ryu, Haeng-Soo;Kim, Myeong-Seok;Han, Gyu-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 2003.07a
    • /
    • pp.357-359
    • /
    • 2003
  • This paper is for the transient analysis of instant short-circuit test equipment according to the test of tripping limits and characteristics under IEC 60947-2. The in-rush current is harmful to almost equipments and the exact testing is not made because of it. LGIS has a instant short-circuit test equipment, but it is not suitable for carrying out instant short-circuit test on ELB(Earth Leakage Circuit breaker) by reason of that. Now, I am going to show a solution for that problem. After applying this method, manufacturer is going to acquire the exact testing result according to the IEC standard. Moreover, Testing laboratory will be trusted by clients.

  • PDF

Case Study of Power Factor Correction Capacitors On Upseting Elevator (고압 커패시터 투입시 수용가측 엘리베이터 정지사례 분석)

  • Cho, Nam-Hun;Jun, Young-Jae;Park, Hea-Chul
    • Proceedings of the KIEE Conference
    • /
    • 2003.07a
    • /
    • pp.33-35
    • /
    • 2003
  • Capacitor switching is essential for the economic operation, and proper voltage control of KOREA electric utility distribution system. Voltage transients produced by capacitor switching (around 2.0 per unit at substation and 2.5 or less per unit at customer site, and lasting less then 1ms) do not have the magnitude or duration to interfere with the operation of computers, but they do disrupt the operation of adjustable speed drivers. The result of our research, ASD manufacturers should team from the computer industry and design products that will operate satisfactory in the electrical envelopment in which they will be placed. In this case history, the inductors on the input to ADSs in order to prevent nuisance tripping from capacitor switching(and other causes within the apartment) proved to be an effective, low-cost solution.

  • PDF

Influence of Flow Conditions on a Boundary Layer to the Near-Wake of a Flat Plat (평판 경계층 유동조건이 근접후류에 미치는 영향)

  • Kim, D.H.;Chang, J.W.
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.1625-1630
    • /
    • 2004
  • An experimental study was carried out to investigate influence of flow conditions on a boundary layer to the near-wake of a flat plate. The flow condition in the vicinity of trailing edge that is influenced by upstream condition history is an essential factor that determines the physical characteristics of a near-wake. Various tripping wires were used to change boundary layer flow condition of upstream at the freestream velocity of 6.0 m/sec. Measurements of the boundary layer and near-wake according to the change of upstream conditions were conducted by using both I-probe(55P14 for boundary layer) and X-probe(55P61 for wake). Normalized velocity profiles of the boundary layer were shown the flow types such as laminar boundary layer, transition, and turbulent boundary layer at 0.95C from the leading edge. The velocity and turbulence intensity profiles of the near-wake for the case of laminar boundary layer at the flat plate surface exhibited a defect and a double peak showing perfect symmetry, respectively.

  • PDF

Application of Low Voltage High Resistance Grounding in Nuclear Power Plants

  • Chang, Choong-Koo;Hassan, Mostafa Ahmed Fouad
    • Nuclear Engineering and Technology
    • /
    • v.48 no.1
    • /
    • pp.211-217
    • /
    • 2016
  • Most nuclear power plants now utilize solid grounded low voltage systems. For safety and reliability reasons, the low voltage (LV) high resistance grounding (HRG) system is also increasingly used in the pulp and paper, petroleum and chemical, and semiconductor industries. Fault detection is easiest and fastest with a solidly grounded system. However, a solidly grounded system has many limitations such as severe fault damage, poor reliability on essential circuits, and electrical noise caused by the high magnitude of ground fault currents. This paper will briefly address the strengths and weaknesses of LV grounding systems. An example of a low voltage HRG system in the LV system of a nuclear power plant will be presented. The HRG system is highly recommended for LV systems of nuclear power plants if sufficient considerations are provided to prevent nuisance tripping of ground fault relays and to avoid the deterioration of system reliability.

A Study on Implementation of Out-of-Step Detection Algorithm using VHDL (VHDL을 이용한 동기탈조 검출 알고리즘 구현에 관한 연구)

  • Kim, Chul-Hwan;Kwon, O-Sang
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.55 no.5
    • /
    • pp.179-184
    • /
    • 2006
  • In a power system, an out-of-step condition causes a variety of risk such as serious damage to system elements, tripping of loads and generators, mal-operation of relays, etc. Therefore, it is very important to detect the out-of- step condition and take a proper measure. This paper presents a study on implementation of out-of-step detection algorithm using VHDL(Very high speed Hardware Description Language). The structure of out-of-step detection algorithm is analyzed for development of out-of-step detection relay on the FPGA(Field Programmable Gate Array). The out-of-step algorithm is separated to 4 parts: DFT IP, complex power calculation IP, out-of-step detection IP, control unit. Each parts are developed and simulated by using VHDL.

Islanding Detection for Distributed Generation

  • Ding, X.;Crossley, P.A.;Morrow, D.J.
    • Journal of Electrical Engineering and Technology
    • /
    • v.2 no.1
    • /
    • pp.19-28
    • /
    • 2007
  • The paper discussed various techniques for islanding detection and described in detail the working principles of ROCOF and vector shift relays. A simulator was used to investigate why the stability of both types of relays maybe affected by network and load switching, short-circuit faults and in the case of a ROCOF relay the loss of bulk generation or the tripping of a transmission feeder. Finally, to enhance the reliability of Loss of Mains protection, a new islanding detection technique based on a GPS synchronized phasor measurement system was proposed.

An Enhanced Zone 3 Algorithm of a Distance Relay using Transient Components and State Diagram (과도성분과 상태도를 이용한 거리 계전기의 향상된 Zone 3 알고리즘)

  • Heo, J.Y.;Kim, C.H.;Park, N.O.
    • Proceedings of the KIEE Conference
    • /
    • 2003.11a
    • /
    • pp.245-247
    • /
    • 2003
  • Zone 3 of the distance relay is used to provide the remote back-up protection in case of the failure of the primary protection. However, the risk for mal-operations under stressed conditions such as heavy loading, voltage and transient instability is usually high. Zone 3 is used in combination with the derivatives of the voltage, and current, etc to prevent mal-operations. Sometimes, the impedance characteristics that restrict the tripping area of relay are used to avoid the mal-operations due to load encroachment. This paper presents a novel zone 3 scheme based on combining the steady-state components(i.e. 60Hz) and the transient components(TCs) using a state diagram that visualizes the sequence of studies that emanate from the sequence of events. The simulation results show that the novel zone 3 distance relay elements using the proposed method operates correctly for the various events.

  • PDF