• Title/Summary/Keyword: Triple difference

Search Result 149, Processing Time 0.037 seconds

Epidemiologic investigation of gastrointestinal pathogens for Korean cats with digestive sign

  • Lee, Mi-Jin;An, Fujin;Lee, Gijong;Park, Jin-ho
    • Korean Journal of Veterinary Service
    • /
    • v.45 no.2
    • /
    • pp.101-110
    • /
    • 2022
  • This study was performed to investigate infectious gastrointestinal diseases in 115 Korean cats (83 indoors and 32 outdoors) with digestive signs such as diarrhea, anorexia or abdominal distention. Detection of infectious pathogens was analyzed using real-time PCR. As a result, 85 of 115 Korean cats were detected with feline corona virus (FCoV), feline parvo virus, Group A rotavirus, Clostridium perfringens (C. perfringens), Campylobacter coli (C. coli), Campylobacter jejuni, enterotoxigenic Escherichia coli, enteropathogenic Escherichia coli, Salmonella spp., Tritrichomonas foetus, Cyclospora cayetanensis, and Giardia lamblia. The most frequently detected pathogen was C. perfringens (52 cats, 61.2%), followed by FCoV (43 cats, 50.6%) and C. coli (16 cats, 18.8%). Also, single infection was the most common (43 cats), followed by double infection in 31 cats, triple infection in 7 cats, and quadruple infection in 4 cats. There was no significant relationship between pathogen detection and age, gender, living environment, weather, and diarrhea. However, there was a significant difference between the age group under 1 year and the age group 1~7 (P value<0.05). In this study, cats with suspected gastrointestinal infection were randomly evaluated, and other factors that could affect pathogen detection were insufficiently considered. For this reason, additional epidemiological investigations with a larger number of cats and sufficient consideration of the causes that may affect the results are needed. Nevertheless, it is thought that this study can also provide valuable information on gastrointestinal pathogens in Korean cats.

Genetic polymorphism of merozoite surface protein 1 and antifolate-resistant genes in Plasmodium falciparum from Mali and Niger

  • Mahaman Moustapha Lamine;Rabia Maman;Abdoul Aziz Maiga;Ibrahim Maman Laminou
    • Parasites, Hosts and Diseases
    • /
    • v.61 no.4
    • /
    • pp.455-462
    • /
    • 2023
  • Since 2015, countries in the Sahel region have implemented large-scale seasonal malaria chemoprevention (SMC). However, the mass use of sulfadoxine-pyrimethamine (SP) plus amodiaquine impacts the genetic diversity of malaria parasites and their sensitivity to antimalarials. This study aimed to describe and compare the genetic diversity and SP resistance of Plasmodium falciparum strains in Mali and Niger. We collected 400 blood samples in Mali and Niger from children aged 3-59 months suspected of malaria. Of them, 201 tested positive (Niger, 111, 55.2%; Mali, 90, 44.8%). Polymorphism of merozoite surface protein 1 (msp1) genetic marker showed 201 allotypes. The frequency of the RO33 allotype was significantly higher in Niger (63.6%) than in Mali (39.3%). There was no significant difference in the frequency of the K1 and MAD20 allotypes between the 2 countries. The multiplicity of infection was 2 allotypes per patient in Mali and one allotype per patient in Niger. The prevalence of strains with the triple mutants Pfdhfr51I/Pfdhfr59R/Pfdhps436A/F/H and Pfdhfr51I/Pfdhfr59R/Pfdhps437G was 18.1% and 30.2%, respectively, and 7.7% carried the quadruple mutant Pfdhfr51I/Pfdhfr59R/Pfdhps436A/F/H/Pfdhps437G. Despite the significant genetic diversity of parasite populations, the level of SP resistance was comparable between Mali and Niger. The frequency of mutations conferring resistance to SP still allows its effective use in intermittent preventive treatment in pregnant women and in SMC.

Study for Automatic Exposure Control Technique (AEC) in SPECT/CT for Reducing Exposure Dose and Influencing Image Quality (SPECT/CT에서 자동노출제어(AEC)를 이용함으로써 얻어지는 영상의 질 평가와 피폭선량 감소에 관한 고찰)

  • Yoon, Seok-Hwan;Lee, Sung-Hwan;Cho, Seong-Wook;Kim, Jin-Eui
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.2
    • /
    • pp.33-38
    • /
    • 2014
  • Purpose Auto exposure control (AEC) in SPECT/CT automatically controls the exposure dose (mA) according to patient's shape and size. The aim of this study was to evaluate the effect of AEC in SPECT/CT on exposure dose reduction and image quality. Materials and Methods The model of SPECT/CT used in this study was Discovery 670 (GE, USA), Smart mA for AEC; and $^{99m}Tc$ as a radioisotope. To compare SPECT and CT images by CT exposure dose variation, we used a standard technique set at 80, 100, 120, 140 kVp, 10, 30, 50, 100, 150, 200, 250 mA, and AEC at 80, 100, 120, 140 kVp, 10-250 mA. To evaluate resolution and contrast of SPECT images, triple line phantom and flangeless Esser PET phantom were used. For CT images, noise and uniformity were checked by anthropomrphic chest phantom. For dose evaluation to find DLP value, anthropomorphic chest phantom was used and the CT protocol of torso was applied by standard technique (120 kVp, 100 mA) and AEC (120 kVp, 10-250 mA). Results When standard and AEC were applied, the resolutions at SPECT images with attenuation correction (AC) were the same as FWHM by center 3.65 mm, left 3.48 mm, right 3.61 mm. Contrasts of standard and AEC showed no significant difference: standard 53.5, 29.8, 22.5, 15.8, 6.0, AEC 53.5, 29.6, 22.4, 15.7, 6.1 In CT images, noise values at standard and AEC were 15.4 and 18.5 respectively. The application of AEC increases noise but the value of coefficient variation were 33.8, 24.9 respectively, obtaining uniform noise image. The values of DLP at standard and AEC were 426.78 and 352.09 each, which shows that the application of AEC decreases exposure dose more than standard by approximately 18%. Conclusion The results of our study show that there was no difference of AC in SPECT images based on the CT exposure dose variation at SPECT/CT images. It was found that the increased CT exposure dose leads to the improvement of CT image quality but also increases the exposure dose. Thus, the use of AEC in SPECT/CT contributes to obtaining equal AC SPECT images, and uniform noise in CT images while reducing exposure dose.

  • PDF

Evaluation of Image Quality Based on Time of Flight in PET/CT (PET/CT에서 재구성 프로그램의 성능 평가)

  • Lim, Jung Jin;Yoon, Seok Hwan;Kim, Jong Pil;Nam Koong, Sik;Shin, Seong Hwa;Yoon, Sang Hyeok;Kim, Yeong Seok;Lee, Hyeong Jin;Lee, Hong Jae;Kim, Jin Eui;Woo, Jae Ryong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.2
    • /
    • pp.110-114
    • /
    • 2012
  • Purpose : PET/CT is widely used for early checking up of cancer and following up of pre and post operation. Image reconstruction method is advanced with mechanical function. We want to evaluate image quality of each reconstruction program based on time of flight (TOF). Materials and Methods : After acquiring phantom images during 2 minutes with Gemini TF (Philips, USA), Biograph mCT (Siemens, USA) and Discovery 690 (GE, USA), we reconstructed image applied to Astonish TF (Philips, USA), ultraHD PET (Siemens, USA), Sharp IR (GE, USA) and not applied. inside of Flangeless Esser PET phantom (Data Spectrum corp., USA) was filled with $^{18}F$-FDG 1.11 kBq/ml (30 Ci/ml) and 4 hot inserts (8. 12. 16. 25 mm) were filled with 8.88 kBq/ml (240 ${\mu}Ci/ml$) the ratio of background activity and hot inserts activity was 1 : 8. Inside of triple line phantom (Data Spectrum corp., USA) was filled with $^{18}F$-FDG 37 MBq/ml (1 mCi). Three of lines were filled with 0.37 MBq (100 ${\mu}Ci$). Contrast ratio and background variability were acquired from reconstruction image used Flangeless Esser PET phantom and resolution was acquired from reconstruction image used triple line phantom. Results : The contrast ratio of image which was not applied to Astonish TF was 8.69, 12.28, 19.31, 25.80% in phantom lid of which size was 8, 12, 16, 25 mm and it which was applied to Astonish TF was 6.24, 13.24, 19.55, 27.60%. It which was not applied to ultraHD PET was 4.94, 12.68, 22.09, 30.14%, it which was applied to ultraHD PET was 4.76, 13.23, 23.72, 31.65%. It which was not applied to SharpIR was 13.18, 17.44, 28.76, 34.67%, it which was applied to SharpIR was 13.15, 18.32, 30.33, 35.73%. The background variability of image which was not applied to Astonish TF was 5.51, 5.42, 7.13, 6.28%. it which was applied to Astonish TF was 7.81, 7.94, 6.40 6.28%. It which was not applied to ultraHD PET was 6.46, 6.63, 5.33, 5.21%, it which was applied to ultraHD PET was 6.08, 6.08, 4.45, 4.58%. It which was not applied to SharpIR was 5.93, 4.82, 4.45, 5.09%, it which was applied to SharpIR was 4.80, 3.92, 3.63, 4.50%. The resolution of phantom line of which location was upper, center, right, which was not applied to Astonish TF was 10.77, 11.54, 9.34 mm it which was applied to Astonish TF was 9.54, 8.90, 8.88 mm. It which was not applied to ultraHD PET was 7.84, 6.95, 8.32 mm, it which was applied to ultraHD PET was 7.51, 6.66, 8.27 mm. It which was not applied to SharpIR was 9.35, 8.69, 8.99, it which was applied to SharpIR was 9.88, 9.18, 9.00 mm. Conclusion : Image quality was advanced generally while reconstruction program which is based on time of flight was used. Futhermore difference of result compared each manufacture reconstruction program showed up, however this is caused by specification of instrument of each manufacture and difference of reconstruction algorithm. Therefore we need further examination to find out appropriate reconstruction condition while using reconstruction program used for advance of image quality.

  • PDF

The Efficacy of P2Y12 Reactive Unit to Predict the Periprocedural Thromboembolic and Hemorrhagic Complications According to Clopidogrel Responsiveness and Safety of Modification of Dual Antiplatelet Therapy : A Meta-Analysis

  • Kim, Hyun Jung;Oh, Jae Sang;Park, Sukh Que;Yoon, Seok Mann;Ahn, Hyeong Sik;Kim, Bum Tae
    • Journal of Korean Neurosurgical Society
    • /
    • v.63 no.5
    • /
    • pp.539-549
    • /
    • 2020
  • The efficacy of P2Y12 reaction unit (PRU) of VerifyNow still remains as a controversial issue in neurointervention. So we investigated the usefulness of PRU of VerifyNow to predict the peri-procedural thromboembolic events (TE) and hemorrhagic events (HE). And we evaluated the safety of modified dual antiplatelet therapy (DAPT) or triple antiplatelet therapy (TAPT) for clopidogrel hyporesponders. We searched MEDLINE, EMBASE, the Cochrane Central Register of Controlled Trials, Web of Science and Scopus on August 19 2018. Data was collected the 1) incidence of TE between clopidogrel responder and clopidogrel hypo-responder, 2) incidence of HE between clopidogrel hyper-responder and clopidogrel responder and hypo-responder, and 3) incidence of TE and HE between modified DAPT or TAPT and standard DAPT in clopidogrel hypo-responder. High cut-off value of PRU was defined as PRU >40% or <220. Fifteen studies were enrolled. Clopidogrel responder showed lower incidence of TE than hypo-responder (risk ratio [RR], 0.32; 95% confidence interval [CI], 0.17-0.61; p<0.001). With the high cut-off value of PRU, clopidogrel responder showed more lower incidence of TE than hypo-responder (RR, 0.11; 95% CI, 0.02-0.45; p=0.002). The incidence of periprocedural HE have higher on clopidogrel hyper-responder than clopidogrel responder and hypo-responder (RR, 4.26; 95% CI, 1.10-16.44; p=0.04; I2=66%). The incidence of periprocedural TE after changing regimen of DAPT for clopidogrel hypo-responder have a tendency to reduce, but there was no significant difference between modified DAPT or TAPT group and standard DAPT group (p>0.05). The incidence of periprocedural HE after changing regimen of DAPT for clopidogrel hypo-responder was no significant difference between modified DAPT or TAPT group and standard DAPT group (p>0.05). PRU is a useful tool as a predictor of peri-procedural TE or HE on neurointervention. PRU has a threshold effect of cut-off value to predict the peri-procedural TE. Modified DAPT or TAPT to prevent TE in clopidogrel hypo-responders could not reduce the incidence of TE. We should investigate the further research about modification of regiment on neurointervention.

Effects of amount of phosphate(${P_2}{O_5}$) applied on growth and yields of soybean (인산시비량의 다소가 대두의 생육 및 수량에 미치는 영향)

  • Ki-Jun Kim
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.12
    • /
    • pp.37-41
    • /
    • 1972
  • This study has been conducted to estimate the proper amount of phosphatic fertilizer required to increase-yield in growing soybeans on newly reclaimed-sterile land which is short of phosphatic fertilizer. IKSAN, the variety chosen for this study, was planted, using the plant spacing $60cm{\times}30cm$. Phosphatic fertilizer was applied in 4 levels in none, standard, double, and triple amount. and at the same time, nitrogen and postassium were applied only in standard amount. Randomized block design was applied in arranging the experimental plots. A series of results acquired are summarized as follows. 1. The fact was recognized that only the standard amount of phosphatic fertilizer is effective for increasing the pod numbers and the soybean yield per l0a. 2. The difference in stem length and stem diameter was very remarkable even among individual plants in the same plot, Throughout all four of the plots there were difference in stem length and stem diameter. That is to say, any invariable tendency on them due to the amount of phosphatic fertilizer applied could not be observed at all. 3. It was recognized that amount of phosphatic fertilizer applied did not have a considerable influence upon the weight of the seeds and the number of seeds contained in 0.l8ι. 4. It was observed that the weight of 1000 seeds was strikingly increased as far as double the amount phosphatic fertilizer.

  • PDF

A Comparative Study on Soumin Bojungyikgitang and Bojungyikgitang in the View of Constitution Medicine (소음인(少陰人) 보중익기탕(補中益氣湯)과 보중익기탕(補中益氣湯)에 대한 사상의학적(四象醫學的) 비교(比較) 연구(硏究))

  • Kim, Ilwhan;Kim, kyungyo
    • Journal of Sasang Constitutional Medicine
    • /
    • v.8 no.2
    • /
    • pp.69-94
    • /
    • 1996
  • The main purpose of this work is comparing the difference between Soumin Bojungyikgitang of constitutional medicine and Li Dongyuan's Bojungyikgitang Bojungyikgitang, the prescription originated from the Pi-Wei theory(脾胃論) of Li Dongyuan who was a medical man in the Jin Yuan dynasty, had been used widely for many kinds of disease caused by the singking of the qi of middle energizer due to the weakness of the spleen and stomach. But in the singking of the qi of middle energizer due to the weakness of the spleen and stomach. But in the end of Choseon dynasty Li Je Ma, the creator of the constitutional medicine, modified the Bojungyikgitang and applied to Soumin's disease. In this paper, the difference between the two prescription were investigated from the viewpoint of chinese herb pharmacology and purpose of prescription. Additionally the problems which could be brought out by applying Bojungyikgitang to the Soyangin and the Taeumin were studied. And the conclusion could be summarized as follows: 1. The prescription of the Li Dongyuan's Bojungyikgitang is based on the deficiency of vital energy due to internal damage and the Soumin Bojungyikgitang is useful to only a certain stage of progressing disease on the basis of Shanghanlun(傷寒論). 2. In the Li Dongyuan's Bojungyikgitang, Cimicifugae Rhizoma and Bupleuri Radix were used for emphasizing the ascending action and have the antipyretic action and the effect of elavating of yangqi as they are bitter in taste and cold in nature. 3. In the Soumin Bojungyikgitang, Pogostemonis Herba and Perillae Folium have the ascending-descending action and strengthen the stomach with the effect of mild sweating by pungent taste and warm nature. 4. The effect of elavating of yangqi in the Li Dongyuan's Bojungyikgitang offers the pathway where vital qi go up by eleminating the pathogenic fire with the action of Cimicifugae Rhizoma and Bupleuri Radix in the triple energizer and yangming muscular striae. On the other hand, the Soumin Bojungyikgitang depends on the effect of reinforcing qi and elavating yangqi by Astrgalli Radix entirely and supply vital qi by reinforcing yangqi with Ginseng Rsdix. 5. The exahausion of yin(亡陰證) in the Soyangin exterior syndrome and cold limbs(寒厥證) in Taeumin exterior syndrome are similar to the indication of Li Dongyuan's Bojungyikgitang. As the causes of the disease are fundamentally different in the view of constitutional medicine, the diseases could be aggravated by applying Li's Bojungyikgitang. These results suggest that Li Dongyuan's Bojungyikgitang is proper to the exterior syndrome of Soumin and Soumin Bojungyikgitang seems to be appropriate to the Soumin's disease.

  • PDF

Growth Characteristics of Juvenile Abalone, Haliotis discus hannai by Reared Methods in order to High Density Intermediate Culture in Land-based Tank (육성수조 내 북방전복, Haliotis discus hannai 치패 고밀도 중간양성 사육방식별 성장특성)

  • Lee, Si-Woo;Kim, Byeong-Hak;Park, Min-Woo;Kim, Tae-Ik;Son, Maeng-Hyun
    • The Korean Journal of Malacology
    • /
    • v.31 no.2
    • /
    • pp.83-92
    • /
    • 2015
  • The effect of different intermediated rearing method by expanding the attached floor space in order to highly density culture on the growth characteristics and survival rate of the juvenile abalone, Haliotis discus hannai, were investigated in land-based tanks. The intermediated culture methods was determined thru the shelter counts and layer for 10 month with two replicates : the single layer shelter (SLS), the double layer shelter (DLS), the triple layer shelter (TLS) and the single layer shelter under net cage (SLSNC). In addition, the culture on shallow race way tank had to set up as culture of the ditch raceway tank (CDRT) and the floor race way tank (CFRT). In the growth performance of reared abalone (initial mean shell length $54.18{\pm}7.39mm$ and weight $1.93{\pm}0.14g$) at experimental tanks, that the absolute growth rate (ARG), daily growth rate (DGR) and specific growth rate (SGR) to the shell length and shell breadth was not significant at each experimental tanks except SLSNC. As well as too, weight gain (WG), daily weight gain (DWG) and specific weight gain (SWG) to weight was not significant at each experimental tanks except SLSNC, too. Survival rates of CDRT and CFRT was lower than those of different experimental tanks (P < 0.05). Therefore, these results is showed that high density different intermediated rearing method by expanding the attached floor space for juvenile H. discus hannai was not have difference as growth performance and survival rate both one layer shelter and multi layer shelter. Also, it is considered that shallow race way tank was not useful rearing for the juvenile intermediate culture of H. discus hannai in land based.

Fuel Supply of Direct Carbon Fuel Cells via Thermal Decomposition of Hydrocarbons Inside a Porous Ni Anode (다공성 니켈 연료 전극 내부에서 탄화수소의 열분해를 통한 직접 탄소 연료 전지의 연료공급)

  • Yi, Hakgyu;Li, Chengguo;Jalalabadi, Tahereh;Lee, Donggeun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.39 no.6
    • /
    • pp.527-534
    • /
    • 2015
  • This study offers a novel method for improving the physical contact between the anode and fuel in a direct carbon fuel cell (DCFC): a direct generation of carbon in a porous Ni anode through the thermal decomposition of gaseous hydrocarbons. Three kinds of alkane hydrocarbons with different carbon numbers (CH4, C2H6, and C3H8) are tested. From electron microscope observations of the carbon particles generated from each hydrocarbon, we confirm that more carbon spheres (CS), carbon nanotubes (CNT), and carbon nanofibers (CNF) were identified with increasing carbon number. Raman scattering results revealed that the carbon samples became less crystalline and more flexible with increasing carbon number. DCFC performance was measured at $700^{\circ}C$ with the anode fueled by the same mass of each carbon sample. One-dimensional carbon fuels of CNT and CNF more actively produced and had power densities 148 and 210 times higher than that of the CS, respectively. This difference is partly attributed to the findings that the less-crystalline CNT and CNF have much lower charge transfer resistances than the CS.

Risk Factors of Morbidity and Mortality after Coronary Artery Bypass Grafting (관상동맥우회로 이식술 후 이환과 사망의 위험요인)

  • 박창률;이응배;전상훈;장봉현;이종태;김규태
    • Journal of Chest Surgery
    • /
    • v.31 no.12
    • /
    • pp.1159-1164
    • /
    • 1998
  • Background: Although operative outcome is progressing due to the development of operative techniques and myocardial protection, some patients face an increased morbidity and mortality. Therefore, it has become increasingly important to predict the operative morbidity and mortality. Material and Method: This retrospective study reports the results of risk factor analysis of morbidity and mortality of 137 consecutive patients who were underwent coronary artery bypass graft surgery(CABG). Preoperative variables were age, sex, preoperative myocardial infarction, operative priority, left ventricular ejection fraction, obesity and triple vessel disease. Postoperative morbidities were arrhythmia, wound infection, cerebral infarction, prolonged postoperative hospitalization, pneumonia, acute renal failure, prolonged use of ventilator and operative death. Result: The mean age of total patients was 56.7 years, from 27 to 74. The overall mortality was 6.6%(9 of 137) with the mortality of 3.9%(5 of 128) for elective operation, and 44.4%(4 of 9) for emergent or urgent cases. The morbidity of patients over 65 years was stastistically higher than that of under 65 years. Sex distribution showed no difference in morbidity, however operative mortality rate was slightly higher in women (5/41, 12.19%) than in men(4/96, 4.17%). Morbidity of emergent or urgent operation was 100%, much higher than that of the elective operation. Mortality of the patients whose left ventricular ejection fraction was under 50% was higher than that of those over 50%. Conclusion: We concluded that the risk factors of morbidity after CABG were old age above 65 years and emergent or urgent operation, and that risk factors of mortality were low left venticular ejection fraction under 50% and emergent or urgent operation.

  • PDF