• Title/Summary/Keyword: Trip Generation

Search Result 107, Processing Time 0.039 seconds

Techno-Economic Analysis of Reversible Solid Oxide Fuel Cell System Couple with Waste Steam (폐스팀을 이용한 가역 고체산화물 연료전지의 기술적 경제적 해석)

  • GIAP, VAN-TIEN;LEE, YOUNG DUK;KIM, YOUNG SANG;AHN, KOOK YOUNG
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.30 no.1
    • /
    • pp.21-28
    • /
    • 2019
  • Reversible solid oxide fuel cell (ReSOC) system was integrated with waste steam for electrical energy storage in distributed energy storage application. Waste steam was utilized as external heat in SOEC mode for higher hydrogen production efficiency. Three system configurations were analyzed to evaluate techno-economic performance. The first system is a simple configuration to minimize the cost of balance of plant. The second system is the more complicated configuration with heat recovery steam generator (HRSG). The third system is featured with HRSG and fuel recirculation by blower. Lumped models were used for system performance analyses. The ReSOC stack was characterized by applying area specific resistance value at fixed operating pressure and temperature. In economical assessment, the levelized costs of energy storage (LCOS) were calculated for three system configurations based on capital investment. The system lifetime was assumed 20 years with ReSOC stack replaced every 5 years, inflation rate of 2%, and capacity factor of 80%. The results showed that the exergy round-trip efficiency of system 1, 2, 3 were 47.9%, 48.8%, and 52.8% respectively. The high round-trip efficiency of third system compared to others is attributed to the remarkable reduction in steam requirement and hydrogen compression power owning to fuel recirculation. The result from economic calculation showed that the LCOS values of system 1, 2, 3 were 3.46 ¢/kWh, 3.43 ¢/kWh, and 3.14 ¢/kWh, respectively. Even though the systems 2 and 3 have expensive HRSG, they showed higher round-trip efficiencies and significant reduction in boiler and hydrogen compressor cost.

Protection Coordination Analysis for Distribution Systems Integrated with Distributed Generation (분산전원이 도입된 배전계통의 보호협조 해석방법)

  • Kim, Jae-Eon;Kim, Eui-Hwan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.5
    • /
    • pp.2279-2284
    • /
    • 2011
  • In most of radial distribution systems, the overcurrent protection coordination is adopted for the protection of apparatus and the improvement of electrical power system reliability. The protection coordination structure in distribution substation is composed of several circuit breakers(CB) with distribution lines originating from one substation bus under one transformer, which trip for their fault current. But sufficient analysis is necessary for the capacity of CB's in distribution systems with several distribution generations(DG). In this paper, a protection coordination method not to exceed the traditional capacity of CB's was proposed and certified through simulation by the PSCAD-EMTDC S/W.

Survey on the Adoptability of IT and Smart Sensor Technologies into the Next-Generation High-Speed Train (차세대 고속전철에 적용할 IT 및 스마트센서 기술의 수용성에 관한 조사 연구)

  • Chang, Duk-Jin;Kang, Song-Hee;Song, Dahl-Ho
    • Journal of the Korean Society for Railway
    • /
    • v.12 no.5
    • /
    • pp.649-655
    • /
    • 2009
  • To join the leading four countries in high speed railway technology, the next generation high speed railway technology development project is undergoing. And, applying the IT for the safety and convenience of a passenger and an attendant is one of the research topics of the project. From the 24 derived candidate IT applications, the seven applications, such as information on an individual LCD monitor, an emergency or reminder notification, an Internet connection, remote communication with an attendant, air quality monitoring, extraordinary noise detection, and detection of an emergency in the lavatory, were selected to be implemented on the next generation train. In this paper, we presented the survey that was performed to make the selection process to be objective. Additional findings, such as what other services a passenger wishes to be provided, what activities passengers prefer to do based on duration of the trip, and things that make a passenger discomfort, were summarized.

Reliability Establishment Method of Switchyard Equipment (스위치야드 기기 신뢰도 군축방안)

  • Moon, Su-Cheol;Kim, Keron-Joong
    • Proceedings of the KIEE Conference
    • /
    • 2007.11b
    • /
    • pp.51-53
    • /
    • 2007
  • The nuclear power plant uses the steam which occurs from reactor and T/G the drive. By the T/G in consequence of the fact that the electricity which is produced the power and supplies in transmission system. But, recently the transmission and generation system are placed under deregulation situation from domestic and foreign, the maintenance control is difficult with the accident or the breakdown which relates is increasing. Hereupon, considering for effect to the reactor core against trip element which it does apply a probability concept from the NRC of the United States and it study and the recognition for the importance of the switchyard which is a power equipment which will be revaluated. Hereupon using the American example, the reliability establishment method which is suitable in domestic and it searches it does.

  • PDF

LVRT Scheme for Doubly Fed Induction Generator Systems Based on Flux Tracking Method (자속 추종을 통한 DFIG 시스템의 LVRT 기법)

  • Park, Sun-Young;Chun, Yeong-Han;Lee, Dong-Myung
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.8
    • /
    • pp.1059-1065
    • /
    • 2013
  • Doubly Fed Induction Generator(DFIG) systems occupy the largest proportion of worldwide wind energy generation market. DFIG systems are very sensitive to grid disturbances especially to voltage dips due to the structure of the stator connected to grid. In the past, when a grid fault occurs generators are separated from grid(trip method) in order to protect the systems. Nowadays, due to the growing penetration level of wind power, many countries have made some requirements that wind turbines are required to have Low Voltage Ride Through(LVRT) capability during grid faults. In this paper, a flux tracking LVRT control strategy based on system modeling equations is proposed. The validity of the proposed strategy is verified through computer simulations.

Air Pollution Forecasting Using Urban Transportation Planning Models and Air Pollution Dispersion Models (都市交通計劃 모델과 大氣汚染 擴散모델을 이용한 都市地域 大氣汚染 豫測)

  • 董宗仁;趙康來;金良均;兪 浣
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.2 no.2
    • /
    • pp.31-40
    • /
    • 1986
  • Motor vehicle related air pollution has become more serious because of rapid increase of number of cars, specially in the urban area. The increase trend seems to be accelerated, however, the fact is that road conditions, parking facilities and traffic control systems are far behind coping with this situation. In spite of the lack of related basic data, urban transportation planning (UPT) and air pollution dispersion models were applied to predict air pollution level. In standard UPT model, trip generation, distribution, modal split and network assignment were estimated by experimental equations and appropriate models. The air pollution level in the central business area was believed to be higher and it will increase continuously due to the increase of traffic demand. To meet this situation, air pollution problem should be considered as a part of integrated plannings of urban plans or transportation plans as well as more stringent motor vehicle emission standards, have to be enforced.

  • PDF

Analysis of Trip Generation Behavior Based on the Multiday Travel Data (일기식 개인통행행태를 고려한 통행발생 예측)

  • 민연주
    • Proceedings of the KOR-KST Conference
    • /
    • 1998.10a
    • /
    • pp.73-82
    • /
    • 1998
  • 본 연구의 목적은 일주일간 조사된 개인통행행태를 고려한 각 특성별 통행발생예측 방법을 제시하는데 있다. 이를 위하여 일주일간 통행빈도수의 차이를 고려한 집단간 차이를 검정하고, 그 원인을 분석하여 이에 따른 특성별 개인 통행발생예측 모형을 정립하였다. 전체 표본의 각 특성별 개인 내부 변이성을 분석해 본 결과 기간의 차이에 따른 개인 통행행태의 변화는 직업별, 나이별, 성별, 차량소유 유무, 주택소유 형태, 통행목적, 통행수단, 가구원수에 따라 집단간 차이를 보여주었다. 이러한 변수를 이용한 통행발생 예측모형의 분석결과 개인소득이 높을수록, 주책을 자가로 소유한 경우, 자동차를 소유한 경우, 학생일수록, 유직일수록 개인 통행발생량이 많은 것으로 분석되었다. 반면, 아니는 연령대가 높아질수록 통행수가 적어졌다.

  • PDF

Study on the Application of IT and Smart Sensors to the High-Speed EMU (동력분산형 고속전철에 IT 및 스마트센서의 적용에 관한 연구)

  • Chang, Duk-Jin;Kang, Song-Hee;Song, Dahl-Ho
    • Proceedings of the KSR Conference
    • /
    • 2008.06a
    • /
    • pp.1201-1208
    • /
    • 2008
  • Ubiquotuous technology should be adopted in railroad business to provide passenger's security and convenience. In this project, IT and smart sensor technologies are reviewed, benchmarked, designed, and implemented. The target system is the next generation high speed train to be developed and operated in Korea with the maximum speed of 400km/h. Wireless sensor network with smart sensors is implemented around a train car. PC-like IT terminal will be designed and implemented so an individual passenger can use it to do information retrieval through the Internet, personal data processing, the e-learning, shopping on the railroad, and so on. These provision will give comfort, convenience, and safety of a passenger during his/her trip.

  • PDF

Analysis of characteristics at the various conditions of power system in case of frequency decrease due to disturbances (외란으로 인한 주파수 저하시 계통구성 요인에 따른 특성 분석)

  • Jang, B.T.;Lee, S.Y.;Lee, J.W.;Cho, K.B.;Kwak, N.H.;Ahn, J.S.;Lee, G.J.
    • Proceedings of the KIEE Conference
    • /
    • 2003.11a
    • /
    • pp.190-192
    • /
    • 2003
  • When generators trip on the occurrence of disturbance, the power system frequency declines by the amount of difference between demand and supply due to the imbalance between power generation and load. Even though the power system is operated with the same grid structure, generating capacity, and load, the resulting frequency decline and its recovery slope show different aspects according to the inertia constants of generators, spinning reserves, and the speed adjusting rates at the governors. From this point of view, we analysed differences of frequency decline at the various conditions in domestic power system.

  • PDF

LVRT Control Methods of Renewable Energy Generation Systems (신재생 에너지 발전시스템의 LVRT 제어 방안)

  • Kim, Jin-Hong;Hyon, Byongjo;Park, Joon Sung;Choi, Jun-Hyuk
    • Proceedings of the KIPE Conference
    • /
    • 2015.07a
    • /
    • pp.113-114
    • /
    • 2015
  • 최근 신재생 에너지에 대한 관심이 높아지면서 계통 연계시 안정성 유지에 대한 많은 연구가 이루어지고 있다. 계통의 안정성을 유지하기 위해 각국에서는 계통 연계 규정들을 통해 규제하고 있다. 본 논문은 계통연계형 신재생 에너지 발전 시스템에서 계통 사고 상황시 만족해야하는 LVRT (Low Voltage Ride Through) 규정과 이에 따른 제어 방안에 대한 논문이다. LVRT 규정은 계통 전압 사고시 전압 감소율에 따라서 발전시스템이 계통에 연계되어 있어야하는 조건, trip시킬 조건 및 계통 회복시간등에 대해 규정해 놓았다. 이러한 규정에 따라서 전압 감소율 및 회복 시간에 따라서 무효전류를 공급해주어야 한다. 본 논문에서는 각국의 grid code에 대해 살펴보고 계통사고 상황시 계통연계형 신재생 에너지 발전시스템의 LVRT 제어 방안을 개발하였다. 이 제어 방안은 시뮬레이션을 통해 그 유효성을 검증하였다.

  • PDF