• Title/Summary/Keyword: Trigger Coil

Search Result 16, Processing Time 0.022 seconds

The Design of Phase Angle Controller Reducing Sub-harmonic Current for Universal Motor in Vacuum Cleaner (진공청소기용 유니버셜모터의 고조파전류 저감 위상각제어기 설계)

  • 임홍우;장용해;백형래
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.7 no.3
    • /
    • pp.237-243
    • /
    • 2002
  • The single phase angle control system may become noisy when speed Is modulated with a conventional TRIAC AC controller. But this system is widely used despise of occurring sub-harmonic current because of its simply structure and low cost. Most of the vacuum cleaner drive control system regulates TRIAC's phase angle, so that it is controlled the speed. In the case of marketing product, it is not considered linearity of the speed to minimize occurring harmonic current. The sub-harmonic current reduces effectively in regulating specification TRIAC trigger phase angle. In this paper, we examined about characteristics of phase angle controller and parameter of parallel coil for eliminating sub-harmonic current.

Crystallization Behavior of Polymers as Viewed from the Molecular Level

  • Tashiro, Kohji;Sasaki, Sono;Ueno, Yoko;Yoshioka, Akiko;Kobayashi, Masamichi
    • Macromolecular Research
    • /
    • v.8 no.3
    • /
    • pp.103-115
    • /
    • 2000
  • The structural changes viewed from the molecular level have been investigated for the isothermal crystallization phenomena of polyethylene (PE) and the solvent-induced crystallization phenomenon of syndiotactic polystyrene (sPS) glassy sample. The data, which were collected by the time-resolved measurements of Fourier-transform infrared spectra, Raman spectra, synchrotron-sourced small-angle X-ray scattering, wide-angle X-ray scattering, and so on, were combined together to extract the detailed structural information in these phase transition phenomena. In the case of PE, the isothermal crystallization from the melt to the orthorhombic form was found to occur via the conformationally-disordered trans chain form, followed by the formation of the lamellar stacking structure of regular orthorhombic-type crystals. In the case of sPS, the amorphous chains in the glassy sample were found to enhance the mobility through the interaction with the injected solvent molecules, which act as a trigger to cause the conformational ordering from the random coil to the regular T$_2$G$_2$-type helical form. The thus created short helical segments were found to grow into longer helices, which gathered together to form the crystallites, as revealed by the organized coupling of the infrared, Raman and X-ray scattering data.

  • PDF

Development of Resonant-Type Magnetometer Using High Permeability Isotropic Magnetic Material (고투자율 등방성 자기 물질을 이용한 공진형 마그네토미터 개발)

  • Yim, Jeong-Bin;Shim, Yeong-Ho;Ahn, Yeong-Sub
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.11 no.1 s.22
    • /
    • pp.29-37
    • /
    • 2005
  • The design and development if Resonant-type Magnetometer(RM) using isotropic magnetic with high permeability is described in this paper. At first, the relationship between the inductance L if the coil winding on a magnetic material and the permeability u(H) appearing in the magnetic material with isotropic and high permeability is defined as a background theory. Then the circuit if RM, which is to obtain the values if L as the change qf frequency is implemented using simple Schmitt Trigger Circuit Through the swinging tests, which is to evaluate the measurement ability if RM, the measurement possibility for the component of earth field was confined.

  • PDF

3 Stage 2 Switch Application for Transcranial Magnetic Stimulation

  • Ha, Dong-Ho;Kim, Whi-Young;Choi, Sun-Seob
    • Journal of Magnetics
    • /
    • v.16 no.3
    • /
    • pp.234-239
    • /
    • 2011
  • Transcranial magnetic stimulation utilizes the method of controlling applied time and changing pulse by output pulse through power density control for diagnosis purposes. Transcranial magnetic stimulation can also be used in cases where diagnosis and treatment are difficult since output pulse shape can be changed. As intensity, pulse range, and pulse shape of the stimulation pulse must be changed according to lesion, the existing sine wave-shaped stimulation treatment pulse poses limitations in achieving various treatments and diagnosis. This study actualized a new method of transcranial magnetic stimulation that applies a 3 Stage 2 Switch( power semiconductor 2EA) for controlling pulse repetition rate by achieving numerous switching control of stimulation coil. Intensity, pulse range, and pulse shape of output can be freely changed to transform various treatment pulses in order to overcome limitations in stimulation treatment presented by the previous sine wave pulse shape. The method of freely changing pulse range by using 3 Stage 2 Switch discharge method is proposed. Pulse shape, composed of various pulse ranges, was created by grafting PFN (Pulsed Forming Network) through AVR AT80S8535 one-chip microprocessor technology, and application in transcranial magnetic stimulation was achieved to study the output characteristics of stimulation treatment pulse according to delaying time of the trigger signal applied in section switch.

A System for Concurrent TMS-fMRI and Evaluation of Imaging Effects (동시 뇌경두개자기자극-기능자기공명영상 시행을 위한 홀더 제작과 시뮬레이션 및 영상 데이터 평가)

  • Kim, Jae-Chang;Kyeong, Sunghyon;Lee, Jong Doo;Park, Hae-Jeong
    • Investigative Magnetic Resonance Imaging
    • /
    • v.17 no.3
    • /
    • pp.169-180
    • /
    • 2013
  • Purpose : The purpose of this study was to setup a concuurent transcranial magnetic stimulation (TMS)-functional MRI (fMRI) system for understanding causality of the functional brain network. Materials and Methods: We manufactured a TMS coil holder using nonmagnetic polyether ether ketone (PEEK). We simulated magnetic field distributions in the MR scanner according to TMS coil positions and angles. To minimize image distortions caused by TMS application, we controlled fMRI acquisition and TMS sequences to trigger TMS during inter-volume intervals. Results: Simulation showed that the magnetic field below the center of the coil was dramatically decreased with distance. Through the MR phantom study, we confirmed that TMS application around inter-volume acquisition time = 100 miliseconds reduced imaging distortion. Finally, the applicability of the concurrent TMS-fMRI was tested in preliminary studies with a healthy subject conducting a motor task within TMS-fMRI and passive motor movement induced by TMS in fMRI. Conclusion: In this study, we confirmed that the developed system allows use of TMS inside an fMRI system, which would contribute to the research of brain activation changes and causality in brain connectivity.

Design of Resonant-Type Magnetometer Using High Permeability Isotropic Magnetic Material (고투자율 등방성 자기물질을 이용한 공진형 마그네토미터의 설계)

  • Yim, Jeong-Bin;Sim, Yeong-Ho;Ahn, Yeong-Sub
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • v.29 no.1
    • /
    • pp.133-139
    • /
    • 2005
  • Resonant-Type Magnetometer(RM) using high permeability isotropic magnetic material is designed to implement Smart Digital Compass. Theoretically, the inductance L of a coil, winding on the magnetic core, is proportion to the change of permeability $\mu(H)$ and, the change values of L can be obtain as the change of frequency by simple Schmitt Trigger circuit. By the use of integrated circuit switch, the RM can be designed with simple circuit and it can provide overcoming the drift by temperature and the variation of operating points in $\mu(H)$ curve. The facts that Metglas 2705M is an optimum magnetic material and ship's permanent magnetism can be obtain from measured values of RM are also known in this study.

  • PDF