• Title/Summary/Keyword: Triethylenediamine

Search Result 9, Processing Time 0.021 seconds

Adsorption of Cesium from an Aqueous Solution Using Activated Carbon Impregnated with triethylenediamine (TEDA) (Triethylenediamine (TEDA)로 첨착된 활성탄소를 이용한 수용액에서 세슘의 흡착)

  • Jong-Soo Choi;Suk Soon Choi;Choong Jeon;Tae-Young Jeong;Jeong Hyub Ha;Jae-Hoon Lee
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.31 no.3
    • /
    • pp.65-71
    • /
    • 2023
  • Cesium discharged from nuclear power plants requires technology for safely treating, due to its harmfulness to the human body. In this work, activated carbon impregnated with triethylenediamine (TEDA) process was applied to effectively remove cesium dissolved in aqueous solution. The surfaces on the activated carbon were chemically modified with various TEDA concentrations (2.5, 5.0, 7.5, 10.0, and 12.5%) and the optimal TEDA concentration was obtained to be 5.0% by the assessment for cesium removal efficiency. In addition, when 5.0% TEDA-impregnated activated carbon was used to treat 5.0 and 10.0 mg/L of cesium, the removal efficiency was 71.5% and 61.1%, respectively. Also, it was found to be the chemical adsorption from the adsorption kinetics experiment by temperature change. A novel remediation technology developed in this study could be practically employed for removing cesium contained in surface and ground water.

A Study on the Removal Efficiency of a TEDA Impregnated Charcoal Bed for Methyl iodide under Humid Conditions (습윤 조건하에서 TEDA함침탄소층에 의한 Methyl Iodide 제거효율에 관한 연구)

  • Won Jin Cho;Soon Heung Chang
    • Nuclear Engineering and Technology
    • /
    • v.16 no.3
    • /
    • pp.161-168
    • /
    • 1984
  • The adsorption model to predict the time dependent removal efficiency of methyl iodide by triethylenediamine (TEDA) impregnated charcoal bed under humid condition is proposed. Under humid conditions, the reduction of equilibrium adsorption capacity and effective pore diffusivity is considered. The predicted values are compared with the experimental results.

  • PDF

Radon Removal Efficiency of Activated Carbon Filter from Coconut (코코넛 기반 활성탄 필터의 라돈 제거 효율)

  • Yun-Jin Ahn;Gi-Sub Kim;Tae-Hwan Kim;Sang-Rok Kim
    • Journal of radiological science and technology
    • /
    • v.46 no.2
    • /
    • pp.141-149
    • /
    • 2023
  • The Korea Institute of Radiological and Medical Sciences plans to produce 225Ac, a therapeutic radio-pharmaceutical for precision oncology, such as prostate cancer. Radon, a radioactive gas, is generated by radium, the target material for producing 225Ac. The radon concentration is expected to be about 2000 Bq·m-3. High-concentration radon-generating facilities must meet radioactive isotope emission standards by lowering the radon concentration. However, most existing studies concerning radon removal using activated carbon filters measured radon levels at concentrations lower than 1000 Bq·m-3. This study measured 222Rn removal of coconut-based activated carbon filter under a high radon concentration of about 2000 Bq·m-3. The 222Rn removal efficiency of activated carbon impregnated with triethylenediamine was also measured. As a result, the 222Rn removal amount of the activated carbon filter showed sufficient removal efficiency in a 222Rn concentration environment of about 2000 Bq·m-3. In addition, despite an expectation of low radon reduction efficiency of Triethylenediamine-impregnated activated carbon, it was difficult to confirm a significant difference in the results. Therefore, it is considered that activated carbon can be used as a radioisotope exhaust filter regardless of whether or not Triethylenediamine is impregnated. The results of this study are expected to be used as primary data when building an air purification system for radiation safety management in facilities with radon concentrations of about 2000 Bq·m-3.

Impregnated Active Carbon-Shelf Life Studies and Its Evaluation Against Cyanogen Chloride with and without Canister

  • Singh, Beer;Saxena, Amit;Srivastava, Avanish Kumar;Dubey, Devendra Kumar;Gupta, Arvind Kumar
    • Carbon letters
    • /
    • v.8 no.4
    • /
    • pp.280-284
    • /
    • 2007
  • Samples of active carbon of $1150\;m^2/g$ surface area were impregnated with ammoniacal salts of copper, chromium and silver, with and without triethylenediamine. The samples of impregnated carbon were aged at $50^{\circ}C$, with and without 90% RH (relative humidity), for a little more than one year and chemically evaluated periodically. Initially copper (II) and chromium (VI) reduced very fast in the samples in humid atmosphere to the extent of 30% and 60% respectively in four months. These values were found to be unaffected by the presence of triethylenediamine (TEDA) indicating that the chemical did not retard the reduction process of chromium (VI) and copper (II). However, in the absence of humidity the reduction of the impregnants was significantly less (10-12%, w/w) in four months. It was quite evident; therefore, that the moisture was mainly responsible for the reduction of chromium (VI) and copper (II) species in impregnated carbons. The prolonged ageing of the samples with and without triethylenediamme after four months with and without humid atmosphere showed that the extent of reduction of chromium (VI) was very low, i.e. 5-10% and of copper (II) was 2-25%. Silver is not reduced due to carbon, as it remained unchanged in concentration on storage. The impregnated carbon samples (100 g) without triethylenediamine, which were aged at room temperature for 5 years in absence of humidity and unaged when evaluated against cyanogen chloride (CNCl) at a concentration of 4 mg/L and airflow rate of 30 lpm showed a high degree of protection (80- 110 minutes).

Electroanalytical Measurement of TEDA (Triethylenediamine) in the Masks of War

  • Ariani, Zahra;Honarmand, Ebrahim;Mostaanzadeh, Hossein;Motaghedifard, Mohammadhassan;Behpour, Mohsen
    • Journal of Electrochemical Science and Technology
    • /
    • v.8 no.1
    • /
    • pp.43-52
    • /
    • 2017
  • In this paper, for the first time, the electroanalytical study of Triethylenediamine, TEDA was done on a typically graphene modified carbon paste electrode (Gr/CPE) in pH=10.5 of phosphate buffer solutions (PBS). The surface morphology of the bare and modified electrodes was characterized by scanning electron microscopy (SEM), electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV). The electro-oxidation of TEDA was investigated at the surface of modified electrode. The results revealed that the oxidation peak current of TEDA at the surface of Gr/CPE is 2.70 times than that shown at bare-CPE. A linear calibration plot was observed in the range of 1.0 to 202.0 ppm. In this way, the detection limit was found to be 0.18 ppm. The method was then successfully applied to determination of TEDA in aqueous samples obtained from two kinds of activated carbon from the masks of war. On the other hand, density functional theory (DFT) method at B3LYP/6-311++G** level of theory and a conductor-like Polarizable Continuum Model (CPCM) was used to calculate the $pK_a$ values of TEDA. The energies of lowest unoccupied molecular orbital ($E_{LUMO}$) and highest occupied molecular orbital ($E_{HOMO}$), gap energy (${\Delta}E$) and some thermodynamic parameters such as Gibbs free energy of TEDA and its conjugate acid ($HT^+$) were calculated. The results of calculated $pK_a$ were found to be in good agreement with the experimental values.

Study on the Removal Efficiency of a TEDA Impregnated Charcoal Bed for Methyliodide under Dry Condition (건조 조건하에서 TEDA주입 탄소층에 의한 Methyliodide 제거 효율에 관한 연구)

  • Won Jim Cho;Soon Heung Chang
    • Nuclear Engineering and Technology
    • /
    • v.16 no.2
    • /
    • pp.80-88
    • /
    • 1984
  • The removal mechanism of air borne methyl iodide by triethylenediamine (TEDA) impregnated charcoal bed was investigated. The analysis of experimental data indicates that pore diffusion is the rate controlling step when the air velocity is over 20cm/sec, and both fore diffusion resistance and external mass transfer resistance are contributed to the overall resistance when the air velocity is 10cm/sec. The adsorption model to describe the performance of impregnated charcoal bed under dry condition where water vapors do not exist in air, is proposed. The calculated values and experimental results are well matched.

  • PDF

Removal of radioactive methyliodide from the gas stream with a composite sorbent based on polyurethane foam

  • Obruchikov, Alexander V.;Magomedbekov, Eldar P.;Merkushkin, Aleksei O.
    • Nuclear Engineering and Technology
    • /
    • v.52 no.5
    • /
    • pp.1093-1097
    • /
    • 2020
  • A composite iodine sorbent was obtained in the form of porous polymer matrix with activated carbon particles impregnated with triethylenediamine deposited on its surface. A comparative assessment of the radioactive methyliodide capturing efficiency by the composite sorbent and a sample of industrial charcoal sorbent was conducted. It was shown that under the selected testing conditions, the hydraulic resistance of the composite sorbent is lower, and the sorption capacity is higher than that of the industrial charcoal sorbent. A method for comparing the effectiveness of iodine sorbents, based on the calculation of the ratio of the sorption capacity index to the minimum capacity index, needed for the required purification degree was proposed.

Radioiodine removal from air streams with impregnated UVIS® carbon fiber

  • Obruchikov, Alexander V.;Merkushkin, Aleksei O.;Magomedbekov, Eldar P.;Anurova, Olga M.
    • Nuclear Engineering and Technology
    • /
    • v.53 no.5
    • /
    • pp.1717-1722
    • /
    • 2021
  • This study is devoted to the ability of carbon fiber material samples impregnated with various amounts of barium iodide and triethylenediamine to remove radioactive methyliodide from air streams. The main sorption characteristics of impregnated UVIS® carbon fiber were determined and the use of this material for purifying of technological gas flows at nuclear power plants was evaluated. The methyliodide trapping efficiency by samples impregnated with barium iodide, TEDA, and their mixture was 83.4 ± 0.8%; 93.1 ± 0.6% and 93.5 ± 0.7% respectively, under the same conditions. The study established a significantly higher capacity (8.3 ± 0.07 mg/cm2) of samples impregnated simultaneously with both chemical compounds toward methyliodide. Under the same test conditions, the values of this parameter for the samples impregnated separately with TEDA and BaI2 were 2.85 ± 0.05 mg/cm2 and 0.86 ± 0.04 mg/cm2, respectively.

Analysis of a Gas Mask Using CFD Simulation (CFD모사기법을 이용한 가스 여과기 성능 해석)

  • Jeon, Rakyoung;Kwon, Kihyun;Yoon, Soonmin;Park, Myungkyu;Lee, Changha;Oh, Min
    • Korean Chemical Engineering Research
    • /
    • v.57 no.4
    • /
    • pp.475-483
    • /
    • 2019
  • Special chemical warfare agents are lethal gases that attack the human respiratory system. One of such gases are blood agents that react with the irons present in the electron transfer system of the human body. This reaction stops internal respiration and eventually causes death. The molecular sizes of these agents are smaller than the pores of an activated carbon, making chemical adsorption the only alternative method for removing them. In this study, we carried out a Computational Fluid Dynamics simulation by passing a blood agent: cyanogen chloride gas through an SG-1 gas mask canister developed by SG Safety Corporation. The adsorption bed consisted of a Silver-Zinc-Molybdenum-Triethylenediamine activated carbon impregnated with copper, silver, zinc and molybdenum ions. The kinetic analysis of the chemical adsorption was performed in accordance with the test procedure for the gas mask canister and was validated by the kinetic data obtained from experimental results. We predicted the dynamic behaviors of the main variables such as the pressure drop inside the canister and the amount of gas adsorbed by chemisorption. By using a granular packed bed instead of the Ergun equation that is used to model porous materials in Computational Fluid Dynamics, applicable results of the activated carbon were obtained. Dynamic simulations and flow analyses of the chemical adsorption with varying gas flow rates were also executed.