• 제목/요약/키워드: Triangular Channel

검색결과 66건 처리시간 0.022초

Isonumber based Iso-Key Interchange Protocol for Network Communication

  • Dani, Mamta S.;Meshram, Akshaykumar;Pohane, Rupesh;Meshram, Rupali R.
    • International Journal of Computer Science & Network Security
    • /
    • 제22권2호
    • /
    • pp.209-213
    • /
    • 2022
  • Key exchange protocol (KEP) is an essential setup to secure authenticates transmission among two or more users in cyberspace. Digital files protected and transmitted by the encryption of the files over public channels, a single key communal concerning the channel parties and utilized for both to encrypt the files as well as decrypt the files. If entirely done, this impedes unauthorized third parties from imposing a key optimal on the authorized parties. In this article, we have suggested a new KEP term as isokey interchange protocol based on generalization of modern mathematics term as isomathematics by utilizing isonumbers for corresponding isounits over the Block Upper Triangular Isomatrices (BUTI) which is secure, feasible and extensible. We also were utilizing arithmetic operations like Isoaddition, isosubtraction, isomultiplication and isodivision from isomathematics to build iso-key interchange protocol for network communication. The execution of our protocol is for two isointegers corresponding two elements of the group of isomatrices and cryptographic performance of products eachother. We demonstrate the protection of suggested isokey interchange protocol against Brute force attacks, Menezes et al. algorithm and Climent et al. algorithm.

개수로에서의 부정류 수문곡선 재현을 위한 유량공급장치의 개발 및 정확도 분석 (Development and Accuracy Analysis of the Discharge-Supply System to Generate Hydrographs for Unsteady Flow in the Open Channel)

  • 김서준;김상혁;윤병만;지운
    • 한국수자원학회논문집
    • /
    • 제45권8호
    • /
    • pp.783-794
    • /
    • 2012
  • 시간에 따른 하도의 수위 및 유량 변화에 영향을 많이 받는 수리구조물의 설계에 있어서 부정류 흐름 해석은 반드시 필요하다. 일반적으로 부정류 흐름 해석에는 수치모형이 많이 활용되고 있으나 수치모형의 검 보정을 위한 현장 자료의 획득이 어려운 경우가 많다. 또한 자료구축이 가능하더라도 인력과 비용이 많이 소모되며, 측정 정확도를 신뢰하기 어려운 경우가 많다. 이러한 경우 수치모형의 검 보정을 위해 부정류 수리실험을 통해 획득되는 자료를 활용하는 것이 대안이 될 수 있다. 따라서 본 연구에서는 다양한 형태의 부정류 수문곡선을 실험에서 재현할 수 있는 유량공급장치를 개발하고자하며, 개발된 부정류 유량공급장치를 이용하여 수리실험 수로에서 재현되는 수문곡선과 목표 수문곡선을 비교 분석함으로써 재현 정확도를 정량적으로 평가하고자 한다. 본 연구에서는 유량이 급격하게 증가 또는 감소하는 사각형 형태, 첨두유량 발생 시간이 짧은 삼각형 형태 및 일반적인 홍수 수문곡선 형태의 종(bell) 형태 수문곡선을 대상으로 재현 오차 및 Root Mean Square Error (RMSE)를 분석하였다. 재현 정확도 분석 결과, 사각형 형태의 수문곡선 재현 오차는 약 59% 정도로 가장 크게 나타났으며, 삼각형 형태의 수문곡선은 단일첨두와 이중첨두 형태 모두 약 10% 정도의 재현 오차가 나타났지만 홍수 수문곡선 형태인 종 모양의 수문곡선의 재현 오차는 최대 2% 이내인 것으로 나타났다.

Riemann 해법을 이용한 1차원 개수로 수리해석 - 자연하도 적용 (One-dimensional Hydraulic Modeling of Open Channel Flow Using the Riemann Approximate Solver - Application for Natural River)

  • 김지성;한건연
    • 한국수자원학회논문집
    • /
    • 제42권4호
    • /
    • pp.271-279
    • /
    • 2009
  • 본 연구는 단순한 직사각형 하도에서 발생한 댐 붕괴 및 홍수전파 등에서 만족스러운 결과를 보였던 Riemann 근사해법을 이용한 1차원 유한체적기법을 불규칙한 하도형상의 자연하도에 적용하기 위하여 새로운 기법을 개발하는 것이 목적이다. 이를 위하여 자연하천 단면을 등가의 직사각형 단면으로 변환하는 개념을 도입하였으며, 그 결과, 운동량방정식이 수정되었다. 새롭게 개발된 기법을 정확해가 존재하는 삼각형 단면하도의 댐 붕괴 흐름에 적용하고 그 결과를 비교함으로써, 기법의 정확성 및 적용성이 검증되었다. 단면의 형상 및 단면간 거리가 균일하지 않는 자연하도에 적용한 결과는 실측수위와 비교하여 홍수파의 전파 양상, 도수의 발생 위치 및 크기, 그리고 전 구간에서의 최대 수위가 잘 일치함을 나타낸다. 본 연구결과로부터 기존의 균일한 단면을 사용하여 개발된 기법들을 복잡한 수치처리과정 없이 자연하천 단면에 직접 적용할 수 있을 것으로 판단된다.

대경사를 지나는 천수 흐름에서 수정된 정수압의 효과 (Effect of Corrected Hydrostatic Pressure in Shallow-Water Flow over Large Slope)

  • 황승용
    • 한국수자원학회논문집
    • /
    • 제47권12호
    • /
    • pp.1177-1185
    • /
    • 2014
  • 대경사 수로의 부등류에 대해 적용될 수 있도록 수정된, 새로운 정수압 분포를 제시하였다. 이것을 천수방정식에 적용하여 대경사를 지나는 천수 흐름을 정확하게 해석할 수 있는 유한체적 모형을 개발하였다. 포물선형 융기의 배수에 대해 압력 수정이 고려된 모형에서 바닥 경사 생성항의 영향이 줄어들어 융기의 하류에서 도수의 진행 속도가 크게 감소되었다. 삼각형 턱을 지나는 댐 붕괴 흐름에 대한 모의에서 압력 수정항이 추가된 모형으로 디지털 영상분석에 의한 수면을 압력 수정이 고려되지 않은 경우에 비해 더 잘 포착할 수 있음을 확인하였다. 압력 수정항 덕분에, 턱에 반사되는 흐름은 줄어들고 월류는 늘어 모의 결과가 실험 결과에 잘 부합된다. 따라서 댐의 여수로나 해안의 처오름 등 실용적인 문제에 대한 이 모형의 적용성이 기대된다.

전자전용 광대역 평면형 능동위상배열 안테나 시스템 개발 (Development of Wide-Band Planar Active Array Antenna System for Electronic Warfare)

  • 김재덕;조상왕;최삼열;김두환;박희준;김동희;이왕용;김인선;이창훈
    • 한국전자파학회논문지
    • /
    • 제30권6호
    • /
    • pp.467-478
    • /
    • 2019
  • 본 논문에서는 전자전용 재밍 송신기에 사용하기 위해서 개발된 광대역 평면형 능동위상배열 안테나 시스템의 설계 및 제작 그리고 측정 결과를 소개한다. 설계된 시스템은 $45^{\circ}$ slant 광대역 복사소자를 $8{\times}8$ 삼각 배열 구조로 배치하고, 광대역 GaN 반도체 고출력 증폭기와 GaAs 다기능집적회로(MFC)를 적용한 64개의 송신 채널을 구성하여 개발하였다. GaAs다기능집적회로는 광대역에서 빔 편이 현상을 피하기 위한 실시간 지연소자, 디지털 감쇠기 그리고 GaAs 구동증폭기를 포함하고 있어서 송신 빔 조향을 할 수 있으며, 시스템의 전자적 빔 조향 범위는 방위각/고각 방향으로 각각 ${\pm}45^{\circ}/{\pm}25^{\circ}$ 범위에서 가능하다. 개발된 시스템의 송신 빔 패턴 성능을 확인하기 위해 근접 전계 시험 시설을 이용하였다. 전자전용 송신 시스템 빔 패턴 측정 결과, 시스템의 유효방사출력은 목표성능(P) 대비 최대 9.8 dB 이상을 만족하였고, 방위각/고각 방향으로 각각 ${\pm}45^{\circ}/{\pm}25^{\circ}$ 빔 조향 결과 요구성능에 만족함을 확인하였다.

유역특성에 의한 합성단위도의 유도에 관한 연구 (Derivation of the Synthetic Unit Hydrograph Based on the Watershed Characteristics)

  • 서승덕
    • 한국농공학회지
    • /
    • 제17권1호
    • /
    • pp.3642-3654
    • /
    • 1975
  • The purpose of this thesis is to derive a unit hydrograph which may be applied to the ungaged watershed area from the relations between directly measurable unitgraph properties such as peak discharge(qp), time to peak discharge (Tp), and lag time (Lg) and watershed characteristics such as river length(L) from the given station to the upstream limits of the watershed area in km, river length from station to centroid of gravity of the watershed area in km (Lca), and main stream slope in meter per km (S). Other procedure based on routing a time-area diagram through catchment storage named Instantaneous Unit Hydrograph(IUH). Dimensionless unitgraph also analysed in brief. The basic data (1969 to 1973) used in these studies are 9 recording level gages and rating curves, 41 rain gages and pluviographs, and 40 observed unitgraphs through the 9 sub watersheds in Nak Oong River basin. The results summarized in these studies are as follows; 1. Time in hour from start of rise to peak rate (Tp) generally occured at the position of 0.3Tb (time base of hydrograph) with some indication of higher values for larger watershed. The base flow is comparelatively higher than the other small watershed area. 2. Te losses from rainfall were divided into initial loss and continuing loss. Initial loss may be defined as that portion of storm rainfall which is intercepted by vegetation, held in deppression storage or infiltrated at a high rate early in the storm and continuing loss is defined as the loss which continues at a constant rate throughout the duration of the storm after the initial loss has been satisfied. Tis continuing loss approximates the nearly constant rate of infiltration (${\Phi}$-index method). The loss rate from this analysis was estimated 50 Per cent to the rainfall excess approximately during the surface runoff occured. 3. Stream slope seems approximate, as is usual, to consider the mainstreamonly, not giving any specific consideration to tributary. It is desirable to develop a single measure of slope that is representative of the who1e stream. The mean slope of channel increment in 1 meter per 200 meters and 1 meter per 1400 meters were defined at Gazang and Jindong respectively. It is considered that the slopes are low slightly in the light of other river studies. Flood concentration rate might slightly be low in the Nak Dong river basin. 4. It found that the watershed lag (Lg, hrs) could be expressed by Lg=0.253 (L.Lca)0.4171 The product L.Lca is a measure of the size and shape of the watershed. For the logarithms, the correlation coefficient for Lg was 0.97 which defined that Lg is closely related with the watershed characteristics, L and Lca. 5. Expression for basin might be expected to take form containing theslope as {{{{ { L}_{g }=0.545 {( { L. { L}_{ca } } over { SQRT {s} } ) }^{0.346 } }}}} For the logarithms, the correlation coefficient for Lg was 0.97 which defined that Lg is closely related with the basin characteristics too. It should be needed to take care of analysis which relating to the mean slopes 6. Peak discharge per unit area of unitgraph for standard duration tr, ㎥/sec/$\textrm{km}^2$, was given by qp=10-0.52-0.0184Lg with a indication of lower values for watershed contrary to the higher lag time. For the logarithms, the correlation coefficient qp was 0.998 which defined high sign ificance. The peak discharge of the unitgraph for an area could therefore be expected to take the from Qp=qp. A(㎥/sec). 7. Using the unitgraph parameter Lg, the base length of the unitgraph, in days, was adopted as {{{{ {T}_{b } =0.73+2.073( { { L}_{g } } over {24 } )}}}} with high significant correlation coefficient, 0.92. The constant of the above equation are fixed by the procedure used to separate base flow from direct runoff. 8. The width W75 of the unitgraph at discharge equal to 75 per cent of the peak discharge, in hours and the width W50 at discharge equal to 50 Per cent of the peak discharge in hours, can be estimated from {{{{ { W}_{75 }= { 1.61} over { { q}_{b } ^{1.05 } } }}}} and {{{{ { W}_{50 }= { 2.5} over { { q}_{b } ^{1.05 } } }}}} respectively. This provides supplementary guide for sketching the unitgraph. 9. Above equations define the three factors necessary to construct the unitgraph for duration tr. For the duration tR, the lag is LgR=Lg+0.2(tR-tr) and this modified lag, LgRis used in qp and Tb It the tr happens to be equal to or close to tR, further assume qpR=qp. 10. Triangular hydrograph is a dimensionless unitgraph prepared from the 40 unitgraphs. The equation is shown as {{{{ { q}_{p } = { K.A.Q} over { { T}_{p } } }}}} or {{{{ { q}_{p } = { 0.21A.Q} over { { T}_{p } } }}}} The constant 0.21 is defined to Nak Dong River basin. 11. The base length of the time-area diagram for the IUH routing is {{{{C=0.9 {( { L. { L}_{ca } } over { SQRT { s} } ) }^{1/3 } }}}}. Correlation coefficient for C was 0.983 which defined a high significance. The base length of the T-AD was set to equal the time from the midpoint of rain fall excess to the point of contraflexure. The constant K, derived in this studies is K=8.32+0.0213 {{{{ { L} over { SQRT { s} } }}}} with correlation coefficient, 0.964. 12. In the light of the results analysed in these studies, average errors in the peak discharge of the Synthetic unitgraph, Triangular unitgraph, and IUH were estimated as 2.2, 7.7 and 6.4 per cent respectively to the peak of observed average unitgraph. Each ordinate of the Synthetic unitgraph was approached closely to the observed one.

  • PDF