• Title/Summary/Keyword: Treeing Phenomena

Search Result 29, Processing Time 0.028 seconds

A Study on Time Variation of ${\phi}-a$ Distribution Patterns due to Treeing Propagation in low Density Polyethylene (저밀도 폴리에틸렌에 있어서 트리잉 진전에 따른 ${\phi}-a$ 분포양상의 시간적 변화에 관한 연구)

  • Kang, Tae-O;Baek, Kwan-Hyun;Kim, Myung-Ho;Kim, Kyung-Hwan;Park, Jae-Jun;Kim, Jae-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 1991.11a
    • /
    • pp.427-430
    • /
    • 1991
  • In this study, in order to observe treeing of prebreakdown phenomena, time variation of acoustic emission properties due to initiation and propagation of tree in LDPE was investigated under AC voltage. The experimental results were as following, pulse number and average amplitude of AE were increased along with near breakdown rather than tree initiation, also, according to increasing of applied voltage, tree propagation was blunted, while pulse number and average amplitude of AE was promoted. In each applied voltage, ${\phi}-a$ distributions during propagation of tree were changed to special patterns, skewness S and kurtosis K reflected well time variation of ${\phi}-a$ distribution patterns. It is thought that initiation and propagation state of tree can be easily monitored, so long as time variation of pulse number and average amplitude of AE, skewness Sand kurtosis K of ${\phi}-a$ distribution are always monitored.

  • PDF

A Study on Electric Field Dependence of Tree Shape in Low Density Polyethylene (저밀도폴리에틸렌에서 트리 형상의 전계의존성에 관한 연구)

  • 김재환;박창옥;윤헌주
    • Fire Science and Engineering
    • /
    • v.14 no.1
    • /
    • pp.1-7
    • /
    • 2000
  • Internal insulators give rise to partial discharge(PD), which cause local breakdown and even entire insulation breakdown. Treeing due to PD is one of the main causes of breakdown of the insulating materials and reduction of the insulation life. Therefore the necessity for establishing a method to diagnose the aging of insulation materials and to predict the breakdown of insulation has become important. From this viewpoint, we have studied on Electric Field dependence of tree shape in Low Density Polyethylene about treeing phenomena occurring on the high electrical field. As the result, under the reasoning that the growing of tree supposing when the inner part of tree is either dielectrec or conductor has the intermediate characteristics between dielectrec and conductor, theoretically investicated results well according with the experimental results.

  • PDF

Efficiency Estimation of Toxicity Free Eire Resistance Cable

  • Yoon, Hun-Ju;Hon, Jin-Woong
    • Transactions on Electrical and Electronic Materials
    • /
    • v.3 no.3
    • /
    • pp.34-38
    • /
    • 2002
  • In this paper, efficiency estimation of toxicity fee fire resistance cable experiments was measured smoke density of toxicity free fire resistance polyolefin insulation material and electric field dependence of tree shape in low density polyethylene (LDPE). One of the most serious causes of failure in high-voltage cables, can be an electrical discharge across an internal gab or void in the insulating material. Treeing due to partial discharge is one of the main causes of breakdown in the insulating materials and reduction of the insulation life. Therefore the necessity for establishing a method to diagnose the aging of insulation materials and to predict the breakdown of insulation and research of the fire resistance character has become important. First, we have studied on electric field dependence of tree shape in LDPE about treeing phenomena occurring on the high electrical field. Second, the measurement method is the attenuation quantity of irradiation by smoke accumulating with in a closed chamber due to non-flaming heat decomposition and flaming combustion. A main cause of fire-growth and generating toxic gas when, it bums, should be dealt with great care in life. safety design. The fire gases were occurred carbon monoxide and decomposition than in polyolefin due to incomplete combustion of PVC, which has high content of carbon in chemical compound.

The Deterioration Phenomena for Dielectrics Causing Corona Discharge (Corona방전에 의한 유전체의 열화현상)

  • 성영권;백영학;차균현
    • 전기의세계
    • /
    • v.19 no.6
    • /
    • pp.18-25
    • /
    • 1970
  • The object of this project is to manifest the mechanism of deterioration phenomena for dielectrics causing corona discharge and applies it for determine the standard corona detection technique. As the results, we observed that corona discharges may occur more strongly around cylindrical shape electrode in air than hemisphere shape electrode in vacuum, so that it depends on effects such as shape of the electrode, moisture, surface coditions, etc. According to observed the deterioration of dielectrics takes place in following stages. At first the attacked surface by an electron avalanche is uniformly eroded; then pits are formed; after that sharp channels are formed which lead to break-down as a treeing. The test are accelerated with higher frequencies by the cylindrical bar shape electrode in the pulse stright detection method more sensitive than Lissajous patterns. Lissajous patterns detection method is simple but usually insensitive and has disadvantage that the magnitude of the individual discharge is not measured.

  • PDF

A Study On the Diagnosis Breakdown Using Fractal Characteristics and the Method of Acoustic Emission in Low Density Polyethylene (프랙탈 특성과 음향방출 계측법을 이용한 LDPE 시료에서의 트리잉 파괴진단에 관한 연구)

  • Yoon, H.J.;Park, J.J.;Shin, S.J.;Choi, J.K.;Kim, S.H.;Kim, J.H.
    • Proceedings of the KIEE Conference
    • /
    • 1997.07e
    • /
    • pp.1758-1760
    • /
    • 1997
  • Automatic detection system to detect acoustic emission pulse and fractal dimension were developed, to observe tree deterioration phenomena in LDPE. The purpose of our work are to use acoustic emission system and fractal dimension and to investigate the treeing phenomena in polymeric insulation under applied AC voltage 11[kV] with an artificial needle-shaped void(1.5[mm]) using the above system. We analyzed and phase angle-acoustic emission pulse amplitude-deterioration time ($\Phi$-AEA-t) pattern and phase angle-acoustic emission pulse number-deterioration time($\Phi$-AEN-t) pattern using statistical operators such as skewness, fractal dimension. In this paper show that the correlation of $\Phi$-AEA-t, $\Phi$-AEN-t, fractal dimension using regression analysis by the method of least squares can be used to predict the breakdown just before the breakdown occurs.

  • PDF

An Experimental investigation on the dependation characteristics of CN/CV cables : dependence on the materials and curing process (배전용 CN/CV 케이블의 절연재료 및 가교방식별 열화특성연구)

  • Kim, H.J.;Choi, Y.H.;Ahn, Y.K.;Kim, K.S.;Koo, J.Y.
    • Proceedings of the KIEE Conference
    • /
    • 1992.07b
    • /
    • pp.969-972
    • /
    • 1992
  • It is shown that the ac breakdown strength, treeing phenomena, oxidation level, and crystallinity of unaged and aged distribution CV cables vary with XLPE insulations (characterizing anti-oxidation) and curing process. The maximum size of bow-tie tree in insulation influenced on the decrease of ac breakdown strength and the increase of oxidation level and crystallinity of XLPE according to aging time lead to increase the size and density of bow-tie trees.

  • PDF

Treeing Phenomena to High Temperature for Epoxy Based Nanocomposites (에폭시기반 나노콤포지트의 고온부에서 트리잉현상)

  • Park, Jae-Jun;Cho, Dae-Ryung;Um, Ji-Yong;Yun, Yo-Wook;Baek, Kwan-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2008.10a
    • /
    • pp.155-156
    • /
    • 2008
  • 물리적 분산기법으로 초음파와 균질기를 동시에 적용한 분산기법을 이용하여 에폭시 기반 층상나노실리케이트를 충진한 에폭시-나노콤포지트 제조하였다. 유리천이온도 특성으로 무충진 에폭시수지와 층상실리케이트가 충진된 나노콤포지트의 비교에서 $9.2^{\circ}C$가 상승되는 결과를 얻었다. 고온부인 $130^{\circ}C$ 환경온도에서 장시간 트리잉 절연파괴측정에서 무충진에폭시 수지에 비하여 나노콤포지트가 절연파괴시간이 13.39배 늦은 시간에 파괴되었고, 트리진전속도의 경우 나노콤포지트가 13.9배 늦은 지연속도를 나타내었다.

  • PDF

Development of a Measurement Method for Three Dimensional Treeing Degradation using a Computerized Tomography Method

  • Masateru-Yanagiwara;Noboru-Yoshimura
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1990.10a
    • /
    • pp.23-25
    • /
    • 1990
  • In this paper, a system to measure tree degradation of three dimensional phenomena in organic insulating materials using image processing system is discussed. Using a computerized tomography method, volume of tree immediately after tree initiation, as well as changes in the configuration of the tree were measured, which up to now have been difficult to measure. The specimens used an acrylic acid resin. As a result, it was possible to record the cross sections of the tree, and to describe the volume of the tree by the three dimensional measurement.

Applied Voltage Dependence of Treeing Growth in GN Introduced Epoxy Resin System (GN이 도입된 에폭시 수지계의 트리 진전의 인가 전압 의존성)

  • An, Hyun-Soo;Shim, Mi-Ja;Kim, Sang-Wook
    • Proceedings of the KIEE Conference
    • /
    • 1996.11a
    • /
    • pp.212-214
    • /
    • 1996
  • The growth of tree is affected by voltage, frequency, temperature, mechanical stress, etc.. This paper describes the effect of applied voltage on the growth of tree in DGEBA/MDA/GN(10 phr) system. As applied voltage increased, the time to breakdown of the system reduced. As applied time increased, the tree length of X-axis increased with sigmoid shape, however, the tree length of Y-axis increased sharply at the initial step and then were nearly constant. The phenomena of tree were complicated more and more, as applied time increased.

  • PDF