• Title/Summary/Keyword: Tree discharges

Search Result 19, Processing Time 0.028 seconds

Internal PD Pulses Analysis Accompanying with Bush-type Tree in Solid Dielectrics (고체유전체에서 발생한 부시형 전기트리에 수반된 내부 부분방전 펄스 해석)

  • 강성화;홍현문;류부형
    • Journal of the Korean Society of Safety
    • /
    • v.15 no.1
    • /
    • pp.100-105
    • /
    • 2000
  • Correlation between propagation of bush-type electrical tree and internal partial discharges(PD) was discussed. We used specimens with needle-plane electrode system made of LDPE(Low Density Polyethylene), observed inception and propagation of electrical tree by optical microscope interfaced with computer and investigated characteristics of phase resolved PD pulses accompanying with propagation of electrical tree. Electrical tree generally growed bush-type tree. PD data detected and analyzed were average discharge current and statistical operator of q-n, $\psi$- $q_{avg}$, $\psi$-n, ${\psi}-q_{max}$ distribution. Parameters used were skewness, kurtosis, average discharge phase, cross-correlation factor, asymmetry and etc. In generally, average discharge current had good linear relationship with propagation of bush type electrical tree on this experiment. Peak discharge magnitude and repetition rate were increased, but they had not good linear relationship.p.

  • PDF

A Study on Image Processing of Tree Discharges for Insulation Destructive Prediction (절연파괴 예측을 위한 트리방전의 영상처리에 관한 연구)

  • 오무송;김태성
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.14 no.1
    • /
    • pp.26-33
    • /
    • 2001
  • The proposed system was composed of pre-processor which was executing binary/high-pass filtering and post-processor which ranged from statistic data to prediction. In post-processor work, step one was filter process of image, step two was image recognition, and step three was destruction degree/time prediction. After these processing, we could predict image of the last destruction timestamp. This research was produced variation value according to growth of tree pattern. This result showed improved correction, when this research was applied image Processing. Pre-processing step of original image had good result binary work after high pas- filter execution. In the case of using partial discharge of the image, our research could predict the last destruction timestamp. By means of experimental data, this prediction system was acquired $\pm$3.2% error range.

  • PDF

Electrical Pulses of Internal Partial Discharges Accompanying with Electrical Tree in LDPE (LDPE에서 발생된 전기트리에 수반된 내부 부분방전 펄스 해석)

  • Kang, S.H.;Park, Y.G.;Kwon, S.S.;Shin, T.S.;Lim, K.J.
    • Journal of the Korean Society of Safety
    • /
    • v.14 no.1
    • /
    • pp.216-221
    • /
    • 1999
  • The correlation between propagation of electrical tree and internal partial discharges is discussed. We use specimens with needle-plane electrode system made of LDPE(Low Density Polyethylene), observed inception and propagation of electrical tree by optical microscope and investigated the characteristics of the partial discharge (PD) pulses accompanying with propagation of electrical tree. In the specimens with needle-shaped void, the tree propagates branch type. The length of the tree has good linear relation with average discharge power of PD pulses. In the specimens without needle-shaped void, the tree grows bush type tree. The correlation between the area of the tree and the average discharge power of PD pulses has linear relation.

  • PDF

Partial Discharge Detection for the Power Cables using AC and Oscillating wave Voltage (전력케이블에서 교류전압과 진동파 전압을 이용한 부분방전 측정)

  • Kim, Jeong-Tae;Kim, Nam-Jun;Lee, Jeon-Seon;Gu, Ja-Yun
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.48 no.4
    • /
    • pp.247-252
    • /
    • 1999
  • In this paper, in order to investigate availability of the OW-PD measurement method which has been proposed as an alternative of AC-PD measurement method to an after laying test and/or diagnosis for the power cable system, partial discharges owing to the needle-type defect integrated into the cable have been measured using AC and OW(Oscillating Wave) voltages. In the AC-PD measurement, the magnitude, phase and pulse number of partial discharges have been changed with the duration of voltage application, which can be analyzed through the relation with the process of the electrical tree initiation and propagation. In addition, the characteristics of partial discharges using OW voltage are appeared to be similar to those in case of AC-PD measurement and to be different with the shapes of electrical tree. From these results, it is concluded that the OW-PD measurement method is available to the tests for the cable system.

  • PDF

The Characteristics of PD Patterns due to the Aging at the Interface between Solid Insulators (고체절연체 계면에서 부분방전 패턴의 열화에 따른 변화특성)

  • Lee, Woo-Young;Sun, Jong-Ho
    • Proceedings of the KIEE Conference
    • /
    • 1998.07e
    • /
    • pp.1725-1727
    • /
    • 1998
  • In this paper the patterns of partial discharges(PD) occurred from some defects at the interface of cable joints as the function of the phase of the applied voltage were investigated in order to discern the kind of a defect. The results obtained in this study show that it is possible to distinguish the PD patterns between the void discharges and the treeing or tracking discharges which were occured at the cable joint interface. While the state of defect transfers from a void discharge into a tree or tracking discharge with a aging time, the skewness for both half of the applied voltage cycle is observed to go to the negative value.

  • PDF

Fundamental Study of Degradation Diagnosis using AE Signals with Void Discharge in XLPE Insulation (XLPE 절연체의 트리 채널내 보이드방전에 의한 AE신호로 절연열화 검출 기법 연구)

  • Lee, Sang-Woo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.2
    • /
    • pp.75-80
    • /
    • 2006
  • In this paper, to detect and observation the void discharges pulse signal, AE signals and tree growth characteristics in case the high voltage is applied to a XLPE sample for a power cable. We also examined the partial discharge current pulse and AE signals with the increase of the applied voltage in XLPE insulation. The experimental results show that a branch-type tree grows in the presence of the voids, and a bush-type tree grows in the absence of the voids in both samples. A rate of tree growth increases abruptly in proportional to the deterioration time in the presence of the of the voids, but in the absence of the voids, a rate of tree growth decreases as time goes by and finally a breakdown occurs. The frequency band of AE signals that are generated from the partial discharges in a XLPE sample, one of solid dielectric materials, is about 1.0[MHz].

A Study of Measurement of Minimum Ignition Energy for Pine Tree Dust on Electrostatic Discharges (정전기 방전시의 소나무목분의 최소착화에너지 측정에 관한 연구)

  • 이동훈;박한석
    • Journal of the Korean Society of Safety
    • /
    • v.13 no.3
    • /
    • pp.74-79
    • /
    • 1998
  • To establish measuring method for minimum ignition energy of explosive powders caused by electrostatic discharge, A measuring method(Hartman) using a very small quantity of pine tree testing powder was proposed, and the influence of discharge current limiting resistance connected in series into a capacitive discharge circuit on ignition energies of explosive powders was investigated. As a result the minimum ignition energy was 42.25mJ when discharge current limiting resistance 300 $k\Omega$.

  • PDF

A Study on Life Estimate of Insulation Cable for Image Processing of Electrical Tree (전기트리의 영상처리를 이용한 절연케이블의 수명예측에 관한 연구)

  • 정기봉;김형균;김창석;최창주;오무송;김태성
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.07a
    • /
    • pp.319-322
    • /
    • 2001
  • The proposed system was composed of pre-processor which was executing binary/high-pass filtering and post-processor which ranged from statistic data to prediction. In post-processor work, step one was filter process of image, step two was image recognition, and step three was destruction degree/time prediction. After these processing, we could predict image of the last destruction timestamp. This research was produced variation value according to growth of tree pattern. This result showed improved correction, when this research was applied image Processing. Pre-processing step of original image had good result binary work after high pass- filter execution. In the case of using partial discharge of the image, our research could predict the last destruction timestamp. By means of experimental data, this Prediction system was acquired ${\pm}$3.2% error range.

  • PDF

Properties of PD Pulses accompanying with propagation of Bush-type tree in LDPE (LDPE에서 부시형 전기트리의 성장에 수반되는 부분방전 펄스의 특성)

  • 박영국;강성화;정수현;박철현;임기조
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1998.06a
    • /
    • pp.293-296
    • /
    • 1998
  • Surface electrical conduction in insulator is most important factor to assess the insulation performances of outdoor insulating materials. In this paper, contamination performance of the widely used materials for outdoor insulator - porcelain, EPDM, Silicone rubber - were discussed by measuring properties of average leakage current and scintillation discharge pulses under artificial contamination conditions. The artificial contaminations used were deionized distilled water fog, 0.5wt% NaCl salt fog of light pollution and 2wt% NaCl salt fog of medium pollution. The average leakage current was appeared linearly with applied voltage at dry and clean surface condition. The magnitude of leakage current was almost same at different kinds of samples. In case of deionized distilled water fog, the characteristics of leakage current and applied voltage was most different to that in case of dry and clean condition. In case of salt fog pollution condition, The leakage current was increased above critical voltage. The scintillation discharges were also activated at the level. the leakage current and scintillation discharges were increased with increasing pollution degree. The resistance to pollution properties of silicone rubber appeared excellent among them.

  • PDF

Properties of PD Pulses accompanying with Electrical Tree in LDPE (LDPE에서 전기트리에 수반된 부분방전 펄스의 특성)

  • Park, Y.G.;Bae, M.H.;Kang, S.H.;Lim, K.J.;Park, D.H.
    • Proceedings of the KIEE Conference
    • /
    • 1997.07d
    • /
    • pp.1507-1509
    • /
    • 1997
  • Property of insulation of electric machine is severely affected by process of electrical tree growing. Partial discharges(PD) have been used to determine degradation of insulations. In this paper, PD quantities detected and analyzed are PD magnitudes, repetition rates, phase angle distribution of PD pulses, and wavelet transformation. The wavelet transformation is an extended method of fourier transformation. The fourier transformation is a powerful tool for signal analysis, but it can't include informations for time. However the wavelet transformation analysis can include on the informations of time and frequencies at the same time. This paper discusses correlation between process of electrical tree growing and characteristics of PD in LDPE specimens.

  • PDF