• Title/Summary/Keyword: Treatment institution

Search Result 658, Processing Time 0.035 seconds

A comprehensive comparison of IMRT and VMAT plan quality for orbital lymphoma (안와 림프종 환자의 방사선치료를 위한 세기조절방사선치료와 용적세기조절회전치료의 전산화 치료계획에 대한 고찰)

  • Yoo, Soon Mi;Ban, Tae Joon;Yun, In Ha;Baek, Geum Mun;Kwon, Kyung Tae
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.2
    • /
    • pp.281-287
    • /
    • 2014
  • Purpose : The purpose of this study is to compare the plan quality of volumetric-modulated arc therapy (VMAT) and intensity-modulated radiation therapy (IMRT) for the treatment of orbital lymphoma. IMRT, partial single arc(SA) and partial-double arc(DA) VMAT plans for four patients with orbital lymphoma treated at our institution were used for this study. Conformity Index(CI), Paddick's Conformity Index(PCI) and Homogeneity Index(HI) of planning target volume(PTV) were used to evaluate dosimetric quality of each plan. The Monitor Unit (MU), treatment time and dose of ipsilateral lens from each type of plan were measured for comparison. Materials and Methods : The CI of PTV for IMRT, SA and DA were measured as 0.88, 0.86, 0.92. The PCI of DA was the lowest as 1.33. Also HI of DA was the lowest in measured plans as 1.15. Mean dose of lens, lacrimal gland, optic chiasm, the opposite optic nerve and both orbit was analyzed with V30, V20, V10, V5. The result showed that the lowest dose in IMRT highest in SA in opposite lens, lacrimal gland, optic nerve, orbit. Results : Treatment time and average MU of IMRT was about three times higher than SA. Conclusion : Considering the superior plan quality as well as the delivery efficiency of VMAT compared with that of IMRT, VMAT may be the preferred modality for treating orbital lymphoma.

Analysis of Output Constancy Checks Using Process Control Techniques in Linear Accelerators (선형가속기의 출력 특성에 대한 공정능력과 공정가능성을 이용한 통계적 분석)

  • Oh, Se An;Yea, Ji Woon;Kim, Sang Won;Lee, Rena;Kim, Sung Kyu
    • Progress in Medical Physics
    • /
    • v.25 no.3
    • /
    • pp.185-192
    • /
    • 2014
  • The purpose of this study is to evaluate the results for the quality assurance through a statistical analysis on the output characteristics of linear accelerators belonging to Yeungnam University Medical Center by using the Shewhart-type chart, Exponentially weighted moving average chart (EWMA) chart, and process capability indices $C_p$ and $C_{pk}$. To achieve this, we used the output values measured using respective treatment devices (21EX, 21EX-S, and Novalis Tx) by medical physicists every month from September, 2012 to April, 2014. The output characteristics of treatment devices followed the IAEA TRS-398 guidelines, and the measurements included photon beams of 6 MV, 10 MV, and 15 MV and electron beams of 4 MeV, 6 MeV, 9 MeV, 12 MeV, 16MeV, and 20 MeV. The statistical analysis was done for the output characteristics measured, and was corrected every month. The width of control limit of weighting factors and measurement values were calculated as ${\lambda}=0.10$ and L=2.703, respectively; and the process capability indices $C_p$ and $C_{pk}$ were greater than or equal to 1 for all energies of the linear accelerators (21EX, 21EX-S, and Novalis Tx). Measured values of output doses with drastic and minor changes were found through the Shewhart-type chart and EWMA chart, respectively. The process capability indices $C_p$ and $C_{pk}$ of the treatment devices in our institution were, respectively, 2.384 and 2.136 for 21EX, 1.917 and 1.682 for 21EX-S, and 2.895 and 2.473 for Novalis Tx, proving that Novalis Tx has the most stable and accurate output characteristics.

Dosimetric Comparison of Intensity Modulated Radiation, Proton Beam Therapy and Proton Arc Therapy for Para-aortic Lymph Node Tumor (대동맥림프절 종양에 대한 세기조절방사선치료, 양성자치료, 양성자회전치료의 선량 비교평가)

  • Kim, JungHoon
    • Journal of radiological science and technology
    • /
    • v.37 no.4
    • /
    • pp.331-339
    • /
    • 2014
  • To test feasibility of proton arc therapy (PAT) in the treatment of para-aortic lymph node tumor and compare its dosimetric properties with advanced radiotherapy techniques such as intensity modulated radiation therapy (IMRT) and conventional 3D conformal proton beam therapy (PBT). The treatment plans for para-aortic lymph node tumor were planned for 9 patients treated at our institution using IMRT, PBT, and PAT. Feasibility test and dosimetric evaluation were based on comparisons of dose volume histograms (DVHs) which reveal mean dose, $D_{30%}$, $D_{60%}$, $D_{90%}$, $V_{30%}$, $V_{60%}$, $V_{90%}$, organ equivalent doses (OEDs), normal tissue complication probability (NTCP), homogeneity index (HI) and conformity index (CI). The average doses delivered by PAT to the liver, kidney, small bowel, duodenum, stomach were 7.6%, 3%, 17.3%, 26.7%, and 14.4%, of the prescription dose (PD), respectively, which is higher than the doses delivered by IMRT (0.4%, 7.2%, 14.2%, 15.9%, and 12.8%, respectively) and PBT (4.9%, 0.5%, 14.12%, 16.1% 9.9%, respectively). The average homogeneity index and conformity index of tumor using PAT were 12.1 and 1.21, respectively which were much better than IMRT (21.5 and 1.47, respectively) and comparable to PBT (13.1 and 1.23, respectively). The result shows that both NTCP and OED of PAT are generally lower than IMRT and PBT. This study demonstrates that PAT is better in target conformity and homogeneity than IMRT and PBT but worse than IMRT and PBT for most of dosimetric factor which indicate that PAT is not recommended for the treatment of para-aortic lymph node tumor.

The Long-term Clinical Outcomes after Coronary Artery Bypass Graft Surgery (관상동맥 우회술의 장기 임상성적)

  • Park, Chan Beom;Jo, Min-Seop;Kim, Young-Du;Jin, Ung;Moon, Seok-Whan;Kim, Chi-Kyung;Jo, Keon Hyon
    • Journal of Chest Surgery
    • /
    • v.42 no.1
    • /
    • pp.22-27
    • /
    • 2009
  • Background: Coronary artery bypass grafting (CABG) is the standard surgical treatment for coronary artery disease. Although there are many clinical reviews of the long term results after CABG in the Western countries, not many such studies have been done for Korea. Therefore, we reviewed the long term clinical results for the patients who underwent CABG at our hospital. Material and Method: We retrospectively reviewed the medical records of 342 patients who underwent CABG at our hospital from February 1984 to December 2006, which is when CABG was first performed in our institution. A total of 286 patients (83.6%) were able to be followed-up, and the mean follow-up period was $75.7{\pm}46.1$ months. Result: The early mortality rate was 5.6%, and late mortality rate was 23.1%. The one-year survival rate, the five-year survival rate, the ten-year survival rate and the fifteen-year survival rate were 91.5%, 82.1%, 60.7% and 50.0%, respectively. The survival rate was significantly lower for the patients over the age of 60 (p=0.002) and for those with diabetes mellitus (p=0.000), hypertension (p=0.002), multivessel disease (p=0.006) and left ventricular dysfunction (p=0.015). No significant difference was observed between the genders. Multivariate analysis showed that the statistically significant risk factors were diabetes mellitus (p=0.001), age (p=0.005) and those cases for which the left internal thoracic artery was not used (p=0.037). Conclusion: CABG is the effective method of treatment for coronary artery disease. Therefore, active usage of the internal thoracic artery and appropriate medical treatment after surgery, and especially for diabetes mellitus patients, are mandatory for achieving good long-term survival.

Research for Lateral Penumbra and Dose Distribution When Air Gap Changing in Proton Therapy Case (양성자치료시 Air Gap 변화에 따른 Lateral Penumbra와 선량분포 변화에 대한 비교 및 연구)

  • Kim, Jae-Won;Sim, Jin-Seob;Jang, Yo-Jong;Kang, Dong-Yun;Choi, Gye-Suk
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.22 no.1
    • /
    • pp.47-51
    • /
    • 2010
  • Purpose: In the treatment of high-energy protons Air gap (the distance between the patient and the exit Beam) Lateral Penumbra of the changes to the increase in the radiation fields can form unnecessary and Increase the maximum dose at the site of treatment and reduced the minimum dose homogeneity of dose distributions can decline. Air gap due to this change in dose distribution compared to investigate studied. Materials and Methods: Received proton therapy at our institution Lung, Liver patients were selected and the size of six other Air gap in Field A and Field B 2, 4, 6, 8, 10 cm Proton external beam planning system by setting up a treatment plan established. Air gap according to the Lateral Penumbra area and DVH (Dose Volume Histogram) to compare the maximum dose and minimum dose of PCTV areas were compared. In addition, the dose homogeneity within PCTV Homogeneity index to know the value and compared. Results: Air gap (2, 4, 6, 8, 10 cm) at each change in field size were analyzed according to the Lateral Penumbra region Field A Change in the Air gap 2~10 cm by 1.36~1.75 cm, the average continuously increased about 28.7% and Field B Change in the Air gap 2~10 cm by 1.36~1.75 cm, the average continuously increased about 31.6%. The result of DVH analysis for relative dose of the maximum dose According to Air gap 2~10 cm is the mean average of 110.3% from 108.1% to a sustained increased by approximately 2.03% and The average relative dose of minimum dose is the mean average of 93.9% percent to 90.8 percent from the continuous decrease of about 3.31 percent. The result of Homogeneity index value to the according to Air gap 2~10 cm is the 2-fold increase from 1.09 to 2.6. Conclusion: In proton therapy case, we can see the increasing of lateral penumbra area when airgap getting increase. And increasing of Dmax and decreasing Dmin in the field are making increase homogeneity index, So we can realize there are not so good homogeneity in the PCTV. Therefore we should try to minimize air gap in proton therapy case.

  • PDF

A Study of Energy Dependency in Intensity Modulated Radiation Therapy of Lung Cancer (폐암환자의 세기조절방사선치료에서 에너지에 따른 선량분포 특성 비교)

  • Kim, Sung-Kyu;Kim, Myung-Se;Yun, Sang-Mo
    • Progress in Medical Physics
    • /
    • v.19 no.3
    • /
    • pp.191-199
    • /
    • 2008
  • PTV considered for the energy, dose distribution exposed to lung and spinal cord, and the characteristic of DVH(Dose Volume Histogram) were compared and investigated by planning the intensity modulated radiation therapy (IMRT) using the photon energies of 6 MV and 10 MV according to tumor location like as the anterior, middle, and posterior regions of lung, and the mediastinum region in lung cancer patients. Our institution installed the linear accelerator (Varian 21 EX-s, USA) equipped with 120 multileaf collimator for lung cancer patients, which is producing the photon energies of 6 MV and 10 MV, and radiation therapy planning was performed with ECLIPSE system (Varian, SomaVision 6.5, USA), which support inverse treatment planning. The tomographic images of 3 mm slice thickness for lung cancer patients were acquired using planning CT, and acquired tomographic images were sent to the Varis system, and then treatment planning was performed in the ECLIPSE system. The radiation treatment planning of the IMRT was processed from various angles according to the regions of the tumor, and using various beam lines according to the size and location of the tumor. The investigation of the characteristic of dose distributions for the energy of 6 MV and 10 MV according to tumor locations in lung cancer patients resulted that the maximum dose of 10 MV energy was 1.2% less than that of 6 MV energy without depending on the tumor location of lung cancer, and the reduction effects of MU were occurred from 10 to 25 MU. Radiation dose exposed to the lung satisfied the less 30% of V20, however radiation dose in 6 MV energy was from 0.1% to 0.5% less than that in 10 MV energy. Radiation dose exposed to the spinal cord for 6 MV energy was from 0.6% to 2.1% less than that for 6 MV energy.

  • PDF

Suggestion for Comprehensive Quality Assurance of Medical Linear Accelerator in Korea (국내 선형가속기의 포괄적인 품질관리체계에 대한 제언)

  • Choi, Sang Hyoun;Park, Dong-wook;Kim, Kum Bae;Kim, Dong Wook;Lee, Jaiki;Shin, Dong Oh
    • Progress in Medical Physics
    • /
    • v.26 no.4
    • /
    • pp.294-303
    • /
    • 2015
  • American Association of Physicists in Medicine (AAPM) Published Task Group 40 report which includes recommendations for comprehensive quality assurance (QA) for medical linear accelerator in 1994 and TG-142 report for recommendation for QA which includes procedures such as intensity-modulated radiotherapy (IMRT), stereotactic radiosurgery (SRS) and stereotactic body radiation therapy (SBRT) in 2010. Recently, Nuclear Safety and Security Commission (NSSC) published NSSC notification no. 2015-005 which is "Technological standards for radiation safety of medical field". This notification regulate to establish guidelines for quality assurance which includes organization and job, devices, methods/frequency/tolerances and action levels for QA, and to implement quality assurance in each medical institution. For this reason, all of these facilities using medical machine for patient treatment should establish items, frequencies and tolerances for proper QA for medical treatment machine that use the techniques such as non-IMRT, IMRT and SRS/SBRT, and perform quality assurance. For domestic, however, there are lack of guidelines and reports of Korean Society of Medical Physicists (KSMP) for reference to establish systematic QA report in medical institutes. This report, therefore, suggested comprehensive quality assurance system such as the scheme of quality assurance system, which is considered for domestic conditions, based the notification of NSSC and AAPM TG-142 reports. We think that the quality assurance system suggested for medical linear accelerator also help establishing QA system for another high-precision radiation treatment machines.

Results of Treatment for Children with Primary Brain Tumors : Long-Term Follow Up Results of a Single Institute (소아 원발성 뇌종양의 치료 결과 : 단일 기관에서의 장기간 추적 관찰)

  • Choi, Sung-Yeon;Won, Sung-Chul;Lyu, Chuhl-Joo;Oh, Seung-Hwan;Yang, Chang-Hyun;Suh, Chang-Ok;Choi, Joong-Uhn;Kim, Byung-Soo
    • Clinical and Experimental Pediatrics
    • /
    • v.45 no.8
    • /
    • pp.1016-1023
    • /
    • 2002
  • Purpose : Brain tumors are the most common solid tumor in children. We retrospectively investigated the clinical characteristics of pediatric brain tumors, such as age, sex, tumor site and survival, as seen in a single institution over the last 15 years. We tried to evaluate the role of chemotherapy on the survival of some brain tumors. Methods : Three hundred fifty four children with primary brain tumor who were treated at Severance Hospital from Jan. 1985 to Sep. 2001 were enrolled. Results : Pediatric brain tumors were found most frequently in 10-15 years of age group(35.3%) and the ratio of male to female was 1.3 : 1. Supratentorial tumors(52%) were more frequent than infratentorial tumors(48%). Medulloblastoma/primitive neuroectodermal tumor(PNET) was the most common type(24.6%), followed by cerebellar astrocytoma(14.1%). Ten year survival rate of medulloblastoma, cerebellar astrocytoma and cerebral astrocytoma were 59.4%, 79.3% and 71%, respectively. The prognosis for brain stem glioma and glioblastoma multiforme were still grim with a 10 year survival rate of 12.7% and 13.3%, respectively. The addition of chemotherapy for high grade medulloblastoma led to an improved 10 year survival rate of 54.5%, compared with 40% without chemotherapy. Conclusion : The combined use of chemotherapy and radiation and surgery improved survival rate of pediatric brain tumors in our study. Chemotherapy for high grade medulloblastoma improved the 10 year survival rate. Further data analysis of the treatment modalities will lead to better comparisons.

Role of Radiotherapy for Squamous Cell Carcinoma of the External Auditory Canal and Middle Ear (외이도 및 중이 편평상피암의 방사선치료)

  • Kang, Hyun-Cheol;Wu, Hong-Gyun;Lee, Ji-Hye;Park, Charn-Il;Kim, Chong-Sun;Oh, Seung-Ha;Heo, Dae-Seog;Kim, Dong-Wan;Lee, Se-Hoon
    • Radiation Oncology Journal
    • /
    • v.27 no.4
    • /
    • pp.173-180
    • /
    • 2009
  • Purpose: To investigate the role of radiotherapy for squamous cell carcinomas of the external auditory canal and middle ear. Materials and Methods: A series of 35 patients who were treated at a single institution from 1981 through 2007 were retrospectively analyzed. Thirteen patients were treated by radiotherapy alone; four by surgery only and 18 by a combination of surgery and radiotherapy. The total radiation dose ranged from 39~70 Gy (median, 66 Gy) in 13~35 fractions for radiotherapy alone and 44~70 Gy (median, 61.2 Gy) in 22~37 fractions for the combined therapy. Clinical end-points were the cause of specific survival (CSS) and local relapse-free survival (LRFS). The median follow-up time was 2.8 years (range, 0.2~14.6 years). Results: The 3-year CSS and LRFS rate was 80% and 63%, respectively. Based on a univariate analysis, performance status and residual disease after treatment had a significant impact on CSS; performance status and histologic grade for LRFS. Patients treated by radiotherapy alone had more residual disease following the course of treatment compared to patients treated with the combined therapy; 69% vs. 28%, respectively. Conclusion: Our results suggest that radiation alone was not an inferior treatment modality for CSS compared to the combined therapy for squamous cell carcinoma of the external auditory canal and middle ear. However, local failure after radiotherapy is the main issue that will require further improvement to gain optimal local control.

The Significance of Sentinel Node Biopsy in Malignant Melanoma and Squamous Cell Carcinoma of Lower Extremities (하지에 발생한 악성흑색종 및 편평상피세포암에서 소속 림프절 생검의 의미)

  • Kim, Jae-Do;Lee, Gun-Woo;Kwon, Young-Ho;Chung, So-Hak
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.16 no.2
    • /
    • pp.69-73
    • /
    • 2010
  • Purpose: Sentinel lymph node (SLNB) is the first confronted lymph node from primary lesion of tumor through lymphatic drainage, which is important for determining early metastasis and setting guidelines for treatment. We reported significant of sentinel lymph node biopsy in malignant melanoma (MM) and squamous cell carcinoma (SCC) of lower extremities. Materials and Methods: Twenty-five cases of surgically treatment and being possible for follow up more than 1 year among the patients who were diagnosed as MM and SCC in this institution from Sep. 2005 to Jan. 2009, and 10 cases of them were performed SLNB. Average age was 64 years old, and 15 cases of male and 10 cases of female were in this group. Results: 3 years overall survival rate was 100% and 3 years disease-free survival rate was 76%. Metastasis occurred in total 6 patients, 4 cases of inguinal lymph nodes, 1 case of soft tissue around knee, 1 case of left achilles tendon. In 15 cases of not performing SLNB, overall survival rate was 93.3% and disease-free survival rate was 73.3%. In 10 cases of performing SLNB, overall survival rate was 100% and disease-free survival rate was 90%. And only 1 case showed positive finding in the biopsy, and none of the 10 cases showed metastasis in follow-up. Conclusion: SLNB leads simpler and less complications compared to prior elective lymph node dissection, and shows high degree of accuracy. Throughout the SLNB, setting guidelines for treatment by accurate staging is thought to be helpful for increasing the survival rate in the patient with MM and SCC.