• 제목/요약/키워드: Treatment Efficiencies

검색결과 777건 처리시간 0.033초

한국형 Biofilter system의 동절기 처리효율 증진 (Improvement of Treatment Efficiency for the Korean Type Biofilter System in Cold Climates)

  • 권순국;손수근
    • 한국농공학회:학술대회논문집
    • /
    • 한국농공학회 2001년도 학술발표회 발표논문집
    • /
    • pp.501-504
    • /
    • 2001
  • The prototype biofilter was constructed in Suwon campus of Seoul National University and monitored for temperature and treatment efficiencies during a two-year programme. During the winter, daily influent wastewater temperature averages $7.7C^{\circ}$; without heating in 2000 experiment, the treatment efficiencies for BOD and SS droped down to 88.7% and 68.4%, respectively. However, as increased the influent wastewater by installting a heater tank before the biofilter tank in 2001 at the same period ($Feb.\;9{\sim}Mrach\;30$) of 2000 experiment, average daily influent temperature which was $7.2C^{\circ}$ increased to over $18.2C^{\circ}$. As a result, effluent quality remains excellent through the winter and even the post winter with BOD and SS values close to less than 10 mg/L. Nitrification follows temperature patterns. However, there was no improvement of treatment efficiency in total nitrogen (T-N) was observed by increasing temperature.

  • PDF

Nutrient removal from secondary effluent using filamentous algae in raceway ponds

  • Min, Kyung-Jin;Lee, Jongkeun;Cha, Ho-Young;Park, Ki Young
    • Membrane and Water Treatment
    • /
    • 제10권3호
    • /
    • pp.191-199
    • /
    • 2019
  • In this study, we investigated the cultivation possibility using Hydrodictyon reticulatum in a continuous raceway pond as a tertiary sewage treatment plant. The cultivation possibility was evaluated by varying the light quantity, wavelength, and hydraulic retention time (HRT). Experimental results showed that the growth rates of algae and the removal efficiencies of nutrients increased as the light quantity increased, and the maximum photosynthetic rate was maintained at $100{\mu}mol/m^2{\cdot}s$ or higher. When wavelength was varied, nutrient removal efficiency and growth rate increased in the following order: green light, red light, white light, and blue light. The nutrient removal efficiencies and algae productivity in HRT 4 d were better than in HRT 8 d. We conclude that if Hydrodictyon reticulatum is cultivated in a raceway pond and used as a tertiary treatment facility in a sewage treatment plant, nutrients can be effectively removed, and production costs can be reduced.

전극 간격에 따른 전기화학적 처리를 통한 폐수처리에 관한 연구 (A Study on Wastewater Treatment by Electrochemical Treatment with Various Electrode Interval)

  • 송주영
    • 한국응용과학기술학회지
    • /
    • 제36권2호
    • /
    • pp.417-423
    • /
    • 2019
  • 전기화학적 처리를 통해 합성폐수 내의 질산성 질소, 인을 제거하는 새로운 폐수처리 공정 시스템 개발을 위한 연구를 수행하였다. 전류밀도에 따른 제거율은 전류밀도가 높아질수록 질산성 질소의 높은 제거효율을 얻었고, 전극 스위칭시간에 따른 $NO_3^-$ 제거율은 스위칭 간격이 1 min일 때 높은 질산성 질소 제거효율을 얻었다. 전류밀도에 따른 총인 제거율은 전류밀도와 간격의 변화에 크게 영향을 받지 않으면서 90%이상 처리되는 것으로 나타났고, 스위칭시간(1 min간격)의 증가에 따른 총인 제거율은 증가한 것으로 나타났다. 반면 COD의 경우는 전기화학적 처리를 통해서는 처리되지 않는 것으로 나타났으며 오히려 전극이 용출되면서 증가하는 결과를 얻었다. 또한, 전극의 소모율은 스위칭 간격이 짧을수록 적은 것으로 나타났다. 최종적으로 전기화학적 처리(전류밀도 $50mA/cm^2$, 스위칭 간격 1 min, 유량 540 mL/min)를 통해 질소 98.1%, 인 90% 이상의 제거 효율을 얻을 수 있었다.

소규모 고도하수처리를 위한 변형 연속회분식공정에 관한 연구 (The Study of Modified Sequencing Batch Reactor Process for Small Advanced Wastewater Treatment)

  • 한운우;김규형
    • 한국지반환경공학회 논문집
    • /
    • 제9권3호
    • /
    • pp.35-43
    • /
    • 2008
  • 본 연구는 소규모 하수고도처리시설에 대해 변형 연속회분식공정을 적용하여 그 효용성을 평가하였다. 변형 연속회분식공정은 단일 반응조 내에서 유기물질 및 질소, 인 등이 제거되며 유입수의 유량 및 수질특성에 의해 적합한 운전방식을 선택할 수 있다. 각 공정의 기능 향상을 위해 원수 유입조건의 제어, 간헐 폭기방식에 의한 무산소 및 호기조건의 적절한 분배 그리고 처리수와 잉여슬러지의 고액분리를 위한 처리수 배출장치의 적용으로 설계된 유량 및 수질에 비해 낮은 부하 조건임에도 1일 3Cycle 운전모드로써 안정적인 처리효율을 나타냈다. 평가결과 유기물질 제거효율은 BOD의 경우 평균 120.4mg/L에서 6.8mg/L로 94.4%, CODMn은 95.7mg/L에서 11.0mg/L로 88.5%의 처리효율을 나타냈다. T-N의 제거효율은 평균 32.2mg/L의 유입수 농도에 대해서 약 69.6%, T-P의 경우는 유입수 농도 4.65mg/L에 대해 73.6%의 처리효율을 나타냈다. 동절기 평균 T-N과 T- P의 처리효율은 58.8%, 68.5%로 약간 감소하였지만 안정적인 처리효율을 나타냈다. 1차 무산소 호기조건에서 BOD는 90%, T-N은 67% T-P는 46%정도로 제거되었으며 T-P는 2차 무산소 호기조건에서 약 70%정도 제거되었다. 따라서 유입수의 간헐유입과 무산소 호기조건의 적정한 분배에 의해 질산화, 탈질 및 인의 과잉섭취에 유기물이 적절히 이용된 것으로 평가되어 소규모 고도하수처리시설에 적합한 공정으로 판단된다.

  • PDF

제지공정 페슬러지처리용 지렁이 분변토의 담체화 기술 (Immobilization of Earthworm Casts to Treat the Waste Sludge Produced from Pulp & Paper Plants as a Biocarrier)

  • 조욱상;이은영;조남혁
    • 청정기술
    • /
    • 제8권3호
    • /
    • pp.167-172
    • /
    • 2002
  • 제지슬러지를 지렁이에게 급이하여 생산된 분변토의 하 폐수 고도처리용 담체로의 적용 가능성에 대하여 알아보았다. 먼저 폐수를 일반 활성슬러지법으로 운전한 후 이를 담체와 유입수의 조건을 달리하여 영양 염류의 제거 효율을 알아보았다. 담체를 적용하기 전엔 T-P및 T-N의 제거율은 각각 평균 52%와 31%정도로 나타났다. Pellet 형 및 pack 형으로 제조된 두 종류의 분변토 담체를 적용한 후에는 T-P의 경우는 제거효율이 약 1.3~1.4배 증가하였으며 T-N의 제거효율은 약 1.9 ~ 2.0 배 증가하여 상당히 뛰어난 영양염류의 제거 효율을 보여주었다. 또한, T-N 및 T-P의 제거효율은 담체의 종류에는 큰 영향을 받지 않아 다양한 미생물이 서식하는 분변토는 성형 방법에 관계없이 뛰어난 성능을 보임을 알 수 있었다. 반면, 담체 적용 전후의 BOD 및 COD의 제거 효율은 큰 차이가 없었다. 본 연구를 통하여 분변토로 제조된 담체는 하 폐수 고도처리용 담체로의 활용 가능성이 매우 높은 것으로 사료된다.

  • PDF

화학 응집제 투입에 따른 수질항목별 하수처리 반응곡선 (Saturation curves for chemical coagulation of wastewater treatment)

  • 류재나;오재일;이경종
    • 상하수도학회지
    • /
    • 제24권5호
    • /
    • pp.537-548
    • /
    • 2010
  • Recently the Government has announced updated water quality standards for wastewater treatment effluent (become effective in 2012). That includes highly enforced regulations for T-P, BOD and COD, and a large budget, in particular for phosphorus removal, was set by the Ministry of environment. Chemical coagulation destabilizes colloidal particles so that particles grow to larger flocs, and solid particles are removed by solid-liquid separation. The efficiency of chemical coagulation depends on a various factors, including coagulant types and costs, construction and operation costs for the treatment facilities and so on. The proper selection should be based on the treatment efficiency of coagulants and underlying costs. The current research was to evaluate the treatment efficiencies of coagulants on a variety of wastewater influents and to develop saturation curves for several water quality parameters. Typical $Al_2(SO_4)_3$ and $FeCl_3$ were tested under a range of coagulant concentrations. The pollutant removal efficiencies of chemical treatment both for the $Al_2(SO_4)_3$ and $FeCl_3$ were especially high for T-P, followed by SS, BOD and COD. Correlation test also proved the highest relationship between SS and T-P.

전자빔 공정을 이용한 1,4-Dioxane 처리의 통계적 최적화 연구 (The Study of Statistical Optimization of 1,4-dioxane Treatment Using E-beam Process)

  • 황혜영;장순웅
    • 한국지반환경공학회 논문집
    • /
    • 제12권4호
    • /
    • pp.25-31
    • /
    • 2011
  • 본 연구의 목표는 전자빔공정을 통한 1,4-dioxane 처리의 최적화를 이루기 위해 실험계획법을 적용하는 것이다. 주요 인자를 1,4-dioxane removal efficiencies(%), TOC removal efficiencies(%)로 반응표면분석법(RSM) 중 중심합성실험법을 이용하여 수학적으로 표시하였다. 1,4-dioxane의 농도를 "$x_1$", Irradiation intensity를 "$x_2$"로 지정하였다. 1,4-dioxane 농도와 removal efficiencies(%)의 코드화된 회귀방정식은 $y=71.00-10.85x_1+20.67x_2+{1.53x_1}^2-{7.92x_2}^2-1.23x_1x_2$, 1,4-dioxane 농도와 TOC Removal efficiencies(%)의 코드화된 회귀방정식은 $y=44.48-13.25x_1+9.54x_2+{5.43x_1}^2-{1.35x_2}^2+4.45x_1x_2$로 나타났다. 모델 예측식의 $R^2$(Adj.)가 90%이상으로 실험적인 관찰결과 잘 맞는 것으로 나타났다. 마지막으로 조류 Pseudokirchneriella Subcapitata를 이용하여 전자빔에 의한 1,4-dioxane에 대한 독성평가를 실시한 결과 전자빔 조사선량의 증가에 따라 생물학적 방해영향이 저감되었다.

산업폐수처리장에서의 미량유해물질 제거율 평가 (Evaluation of Removal Efficiencies of Micropollutants in Wastewater Treatment Plants)

  • 이인석;심원진;오정은;김창원;장윤석;윤영삼
    • 대한환경공학회지
    • /
    • 제29권2호
    • /
    • pp.214-219
    • /
    • 2007
  • 본 연구에서는 낙동강 수계 9곳의 산업폐수처리장을 대상으로 66종 미량유해물질을 대상으로 미량유해물질의 수계 방류 현황과 처리 공정별 제거율을 조사하였다. 그 결과 산업폐수처리장을 통해 수계로 방류되는 대상 미량유해물질의 농도수준은 기준치 이하이거나 타 연구의 농도수준보다 낮았다. 산업폐수 처리공정을 거치면서 1,4-다이옥산이 가압부상/화학응집, 활성탄흡착 처리공정에 의해 각각 84.6% 및 81.6% 제거되었다. 페놀 및 클로로페놀류, 다환방향족탄화수소류의 경우 표준 활성슬러지법에 의해 각각 94.6%, 66.4% 및 80.6% 제거되었다. 클로로벤젠류는 표준 활성슬러지법과 활성탄흡착법에 의해 각각 45.3% 및 60.6% 제거되었으나, 기타 처리공정에서는 제거율이 매우 낮았다(<20%). 또한 다이옥신류는 입자상 물질을 제거할 수 있는 공정인 사여과(SF)에서 제거효율이 가장 뛰어났지만(99% 이상), 사여과 공정일지라도 유입수의 농도가 낮은 경우에는 제거율이 높지 않았다(50% 이하).

평판식 태양열 공기가열기의 성능에 관한 연구 -도장재료, 도장방법 및 공기통로 구조를 중심으로- (A Study on the Performance of Ak Heaters -Black Coating Materials, Coating Methods and Structure of Air Path-)

  • 박종길;연광석;차균도
    • 한국농공학회지
    • /
    • 제21권1호
    • /
    • pp.78-85
    • /
    • 1979
  • In order to obtain the basic data for designing optimum flat plate solar air heaters, which can be operated with relatively low temperature for drying farm products, 8 different treatment of solar air heaters were devised and tested for their heating performances and efficiencies. The results were analised and summarized as follows. 1. The primary factors, structure of air path (C), black coating materials (A) and bottom coating methods (B) showed very high significant effect of far above 1% level. With respect to the mutual multiplying effect of secondary factors, 1% level of significance was found with coating materials and methods (AB), and 5% level of significance was found with coating materials and air path structure (AC). 2. The heating performance of the air heaters with winding air path showed about twice those with straight air path. 3. The Korean black ink which is less expensive than dim oil paint showed 3-4% better heating efficiencies as the black coating material of flat plate solar air heaters. 4. The heating efficiencies of the solar air heaters whose bottoms were not black coated were 2-3% higher than those with black coated bottoms. 5. The highest heating efficiency of solar air heater among 8 different treatment was found in the plot of Korean black ink-bottom not coated-winding air path showing 29.0-34.5%

  • PDF

철염 응집과 펜톤 산화를 이용한 인의 존재형태별 처리 (Treatment of Phosphorus Species using Iron Coagulation and Fenton Oxidation)

  • 박성환;문병현
    • 한국물환경학회지
    • /
    • 제30권6호
    • /
    • pp.653-657
    • /
    • 2014
  • Effects of $H_2O_2$ addition for fenton oxidation on iron coagulation for treatment of phosphorus species, such as orthophosphate, metaphosphate, pyrophosphate, organic phosphate, were investigated. The effects of coagulant dosage, hydrogen peroxide dosage and the combined sequence ferric coagulation and $H_2O_2$ addition for fenton oxidation and coagulation were studied. The characteristics of floc growth rate were monitored using the PDA. The removal efficiencies of phosphorus species by iron coagulation were increased as Fe/P molar ratio increased. However, the removal efficiencies of metaphosphate, pyrophosphate, organic phosphate by a ferric coagulation were not increased as Fe/P molar ratio increased. The removal efficiency of metaphosphate, pyrophosphate, organic phosphate was increased by using iron coagulation and $H_2O_2$ addition for fenton oxidation. The result indicated that non-reactive phosphorus after iron coagulation was changed to reactive phosphorus by $H_2O_2$ addition for fenton oxidation and the oxidized iron enhanced the coagulation efficiencies.