Improvement of Treatment Efficiency for the Korean Type Biofilter System in Cold Climates

한국형 Biofilter system의 동절기 처리효율 증진

  • Published : 2001.10.12

Abstract

The prototype biofilter was constructed in Suwon campus of Seoul National University and monitored for temperature and treatment efficiencies during a two-year programme. During the winter, daily influent wastewater temperature averages $7.7C^{\circ}$; without heating in 2000 experiment, the treatment efficiencies for BOD and SS droped down to 88.7% and 68.4%, respectively. However, as increased the influent wastewater by installting a heater tank before the biofilter tank in 2001 at the same period ($Feb.\;9{\sim}Mrach\;30$) of 2000 experiment, average daily influent temperature which was $7.2C^{\circ}$ increased to over $18.2C^{\circ}$. As a result, effluent quality remains excellent through the winter and even the post winter with BOD and SS values close to less than 10 mg/L. Nitrification follows temperature patterns. However, there was no improvement of treatment efficiency in total nitrogen (T-N) was observed by increasing temperature.

Keywords