Improvement of Treatment Efficiency for the Korean Type Biofilter System in Cold Climates (한국형 Biofilter system의 동절기 처리효율 증진)

  • Kwun, Soon-Kuk;Son, Su-Keun
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2001.10a
    • /
    • pp.501-504
    • /
    • 2001
  • The prototype biofilter was constructed in Suwon campus of Seoul National University and monitored for temperature and treatment efficiencies during a two-year programme. During the winter, daily influent wastewater temperature averages $7.7C^{\circ}$; without heating in 2000 experiment, the treatment efficiencies for BOD and SS droped down to 88.7% and 68.4%, respectively. However, as increased the influent wastewater by installting a heater tank before the biofilter tank in 2001 at the same period ($Feb.\;9{\sim}Mrach\;30$) of 2000 experiment, average daily influent temperature which was $7.2C^{\circ}$ increased to over $18.2C^{\circ}$. As a result, effluent quality remains excellent through the winter and even the post winter with BOD and SS values close to less than 10 mg/L. Nitrification follows temperature patterns. However, there was no improvement of treatment efficiency in total nitrogen (T-N) was observed by increasing temperature.

  • PDF

Nutrient removal from secondary effluent using filamentous algae in raceway ponds

  • Min, Kyung-Jin;Lee, Jongkeun;Cha, Ho-Young;Park, Ki Young
    • Membrane and Water Treatment
    • /
    • v.10 no.3
    • /
    • pp.191-199
    • /
    • 2019
  • In this study, we investigated the cultivation possibility using Hydrodictyon reticulatum in a continuous raceway pond as a tertiary sewage treatment plant. The cultivation possibility was evaluated by varying the light quantity, wavelength, and hydraulic retention time (HRT). Experimental results showed that the growth rates of algae and the removal efficiencies of nutrients increased as the light quantity increased, and the maximum photosynthetic rate was maintained at $100{\mu}mol/m^2{\cdot}s$ or higher. When wavelength was varied, nutrient removal efficiency and growth rate increased in the following order: green light, red light, white light, and blue light. The nutrient removal efficiencies and algae productivity in HRT 4 d were better than in HRT 8 d. We conclude that if Hydrodictyon reticulatum is cultivated in a raceway pond and used as a tertiary treatment facility in a sewage treatment plant, nutrients can be effectively removed, and production costs can be reduced.

A Study on Wastewater Treatment by Electrochemical Treatment with Various Electrode Interval (전극 간격에 따른 전기화학적 처리를 통한 폐수처리에 관한 연구)

  • Song, Ju Yeong
    • Journal of the Korean Applied Science and Technology
    • /
    • v.36 no.2
    • /
    • pp.417-423
    • /
    • 2019
  • A new wastewater treatment system was developed to remove nitrate nitrogen and phosphorus in synthetic wastewater through electrochemical treatment. Higher removal efficiencies of nitrate nitrogen were obtained as the current density increased. Higher nitrate removal efficiencies were obtained when the switching interval was 1 min. The total phosphorus removal rate according to the current density was found to be over 90% without being greatly affected by the change in current density and interval, and the total removal rate increased with increasing switching time (1 min interval). On the other hand, COD was not treated by electrochemical treatment, but rather increased as the electrode eluted. Also, the consumption rate of the electrode was smaller as the switching interval was shorter. Finally, removal efficiencies of 98.1% of nitrate and 90% of phosphorus were obtained through electrochemical treatment (current density $50mA/cm^2$, switching interval 1 min, flow rate 540 mL/min).

The Study of Modified Sequencing Batch Reactor Process for Small Advanced Wastewater Treatment (소규모 고도하수처리를 위한 변형 연속회분식공정에 관한 연구)

  • Han, Woonwoo;Kim, Kyuhyoung
    • Journal of the Korean GEO-environmental Society
    • /
    • v.9 no.3
    • /
    • pp.35-43
    • /
    • 2008
  • This study was carried out to estimate the performance of modified sequencing batch reactor (SBR) process by the application of SBR process for small advanced wastewater treatment plant. Organic, nitrogen and phosphorus were able to remove in the unit reactor by SBR process and it would be able to select the suitable operation method. The plant was operated to achieve high performance with influent control, optimum anoxic/oxic condition using intermediate aeration method, and solid (sludge) /liquid (effluent) separation by modified decanter. The optimum operating mode was 3Cycles a day and intermediate input and aeration. Under these conditions, the treatment efficiencies were good with 60% of designed flow rate and low influent quality. When the influent concentrations of BOD and CODMn were 120.4 mg/L and 95.7 mg/L, respectively. The effluent concentrations of BOD and CODMn were 6.8 mg/L and 11.0 mg/L, respectively. The average removal efficiencies of BOD and CODMn were 94.4% and 88.5%, respectively. The removal efficiencies of T-N and T-P were 69.6% and 73.6%, respectively when the average T-N and T-P concentrations were 32.2mg/L and 4.65mg/L, respectively. The T-N and T-P removal efficiencies were slightly decreased to 58.8% and 68.5%, respectively in the winter season but its were also stable efficiencies. BOD, T-N and T-P were removed by 90%. 67% and 46% respectively in the first anoxic/oxic condition, in addition to T-P was removed by 70% in the second anoxic/oxic condition. From the results, modified sequencing batch reactor (SBR) process is suitable for small advanced wastewater treatment.

  • PDF

Immobilization of Earthworm Casts to Treat the Waste Sludge Produced from Pulp & Paper Plants as a Biocarrier (제지공정 페슬러지처리용 지렁이 분변토의 담체화 기술)

  • Cho, Wook Sang;Lee, Eun Young;Cho, Nam Hyeuk
    • Clean Technology
    • /
    • v.8 no.3
    • /
    • pp.167-172
    • /
    • 2002
  • The adaptability of earthworm casts produced form the waste sludge of pulp and paper plants for a biocarrier used in the advanced wastewater treatment was investigated. Removal efficiencies of nutrients in the activated sludge technology without carrier were compared with those treated with carrier made of casts under the different conditions such as the composition of the input and kinds of carrier. When the waste water was treated in the activated sludge technology without carriers, removal efficiencies of T-P and T-N were average values of 31% and 52%, respectively. On the contrary, pellet type carrier and pack type carrier increased the removal efficiencies of T-P and T-N by 1.3~1.4 and 1.9~2.0 times, respectively. At the same time, the high removal of T-P and T-N were observed irrespective of the types of carrier in which many kinds of microorganisms were grown. The difference in the removal efficiencies of BOD and COD between the treatment with and without carrier was negligible. According to this research, the carrier made of casts was thought to be highly applicable in the advanced wastewater treatment.

  • PDF

Saturation curves for chemical coagulation of wastewater treatment (화학 응집제 투입에 따른 수질항목별 하수처리 반응곡선)

  • Ryu, Jae-Na;Oh, Je-Ill;Lee, Kyeoung-Jong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.24 no.5
    • /
    • pp.537-548
    • /
    • 2010
  • Recently the Government has announced updated water quality standards for wastewater treatment effluent (become effective in 2012). That includes highly enforced regulations for T-P, BOD and COD, and a large budget, in particular for phosphorus removal, was set by the Ministry of environment. Chemical coagulation destabilizes colloidal particles so that particles grow to larger flocs, and solid particles are removed by solid-liquid separation. The efficiency of chemical coagulation depends on a various factors, including coagulant types and costs, construction and operation costs for the treatment facilities and so on. The proper selection should be based on the treatment efficiency of coagulants and underlying costs. The current research was to evaluate the treatment efficiencies of coagulants on a variety of wastewater influents and to develop saturation curves for several water quality parameters. Typical $Al_2(SO_4)_3$ and $FeCl_3$ were tested under a range of coagulant concentrations. The pollutant removal efficiencies of chemical treatment both for the $Al_2(SO_4)_3$ and $FeCl_3$ were especially high for T-P, followed by SS, BOD and COD. Correlation test also proved the highest relationship between SS and T-P.

The Study of Statistical Optimization of 1,4-dioxane Treatment Using E-beam Process (전자빔 공정을 이용한 1,4-Dioxane 처리의 통계적 최적화 연구)

  • Hwang, Haeyoung;Chang, Soonwoong
    • Journal of the Korean GEO-environmental Society
    • /
    • v.12 no.4
    • /
    • pp.25-31
    • /
    • 2011
  • In this study, the experimental design methodology was applied to optimize 1,4-dioxane treatment in E-beam process. Main factor was mathematically described as a function of parameters 1,4-dioxane removal efficiencies(%), TOC removal efficiencies(%) modeled by the use of the central composite design(CCD) method among the response surface methodology(RSM). Concentration of 1,4-dioxane is designated as "$x_1$" and Irradiation intensity is designated as "$x_2$". The regression equation in coded unit between the 1,4-dioxane concentration and removal efficiencies(%) was $y=71.00-10.85x_1+20.67x_2+{1.53x_1}^2-{7.92x_2}^2-1.23x_1x_2$. The regression equation in coded unit between the 1,4-dioxane concentration and TOC removal efficiencies(%) was $y=44.48-13.25x_1+9.54x_2+{5.43x_1}^2-{1.35x_2}^2+4.45x_1x_2$. The model predictions agreed well with the experimentally observed results $R^2$(Adj) over 90%. Toxicity test using algae Pseudokirchneriella Subcapitata showed that the inhibition was reduced according to increasing an E-beam irradiation.

Evaluation of Removal Efficiencies of Micropollutants in Wastewater Treatment Plants (산업폐수처리장에서의 미량유해물질 제거율 평가)

  • Lee, In-Seok;Sim, Won-Jin;Oh, Jeong-Eun;Kim, Chang-Won;Chang, Yoon-Seok;Yoon, Young-Sam
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.29 no.2
    • /
    • pp.214-219
    • /
    • 2007
  • 66 micropollutants analyses in 9 wastewater treatment plants(WWTPs) along Nak-dong river were implemented to identify the concentrations and removal efficiencies before and after treatment processes. As a result of study, the concentration levels discharged from WWTP effluents to water system were below the water quality criteria and the levels of other studies. The removal efficiencies were 84.6%(DAF/CCR) and 81.6%(AC) for 1,4-dioxane. Phenol, Clphs and PAHs were removed 94.6%, 66.4% and 80.6% respectively by the activated sludge(AS) process. The removal efficiencies of Clbzs were 45.3% for the activated sludge(AS) process and 60.6% for the activated carbon(AC) process. However, other processes besides AS and AC, the removal efficiencies of Clbzs were very low(<20%). The sand filtration(SF) process that could remove particle matters showed the best efficiency for PCDDs / Fs removal$(\geq99%)$. However, in case of relatively low PCDDs/Fs concentration level in influent, the removal efficiency was not so high$(\leq50%)$.

A Study on the Performance of Ak Heaters -Black Coating Materials, Coating Methods and Structure of Air Path- (평판식 태양열 공기가열기의 성능에 관한 연구 -도장재료, 도장방법 및 공기통로 구조를 중심으로-)

  • 박종길;연광석;차균도
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.21 no.1
    • /
    • pp.78-85
    • /
    • 1979
  • In order to obtain the basic data for designing optimum flat plate solar air heaters, which can be operated with relatively low temperature for drying farm products, 8 different treatment of solar air heaters were devised and tested for their heating performances and efficiencies. The results were analised and summarized as follows. 1. The primary factors, structure of air path (C), black coating materials (A) and bottom coating methods (B) showed very high significant effect of far above 1% level. With respect to the mutual multiplying effect of secondary factors, 1% level of significance was found with coating materials and methods (AB), and 5% level of significance was found with coating materials and air path structure (AC). 2. The heating performance of the air heaters with winding air path showed about twice those with straight air path. 3. The Korean black ink which is less expensive than dim oil paint showed 3-4% better heating efficiencies as the black coating material of flat plate solar air heaters. 4. The heating efficiencies of the solar air heaters whose bottoms were not black coated were 2-3% higher than those with black coated bottoms. 5. The highest heating efficiency of solar air heater among 8 different treatment was found in the plot of Korean black ink-bottom not coated-winding air path showing 29.0-34.5%

  • PDF

Treatment of Phosphorus Species using Iron Coagulation and Fenton Oxidation (철염 응집과 펜톤 산화를 이용한 인의 존재형태별 처리)

  • Park, Sung-Hwan;Moon, Byung-Hyun
    • Journal of Korean Society on Water Environment
    • /
    • v.30 no.6
    • /
    • pp.653-657
    • /
    • 2014
  • Effects of $H_2O_2$ addition for fenton oxidation on iron coagulation for treatment of phosphorus species, such as orthophosphate, metaphosphate, pyrophosphate, organic phosphate, were investigated. The effects of coagulant dosage, hydrogen peroxide dosage and the combined sequence ferric coagulation and $H_2O_2$ addition for fenton oxidation and coagulation were studied. The characteristics of floc growth rate were monitored using the PDA. The removal efficiencies of phosphorus species by iron coagulation were increased as Fe/P molar ratio increased. However, the removal efficiencies of metaphosphate, pyrophosphate, organic phosphate by a ferric coagulation were not increased as Fe/P molar ratio increased. The removal efficiency of metaphosphate, pyrophosphate, organic phosphate was increased by using iron coagulation and $H_2O_2$ addition for fenton oxidation. The result indicated that non-reactive phosphorus after iron coagulation was changed to reactive phosphorus by $H_2O_2$ addition for fenton oxidation and the oxidized iron enhanced the coagulation efficiencies.