• Title/Summary/Keyword: Treated sewage

Search Result 244, Processing Time 0.03 seconds

Automatic control of coagulant dosage on the sedimentation and dissolved air flotation(SeDAF) process for enhanced phosphorus removal in sewage treatment facilities (하수처리시설에서 인 고도처리를 위한 일체형 침전부상공정(SeDAF)의 응집제 주입농도 자동제어기법 검토)

  • Jang, Yeoju;Jung, Jinhong;Kim, Weonjae
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.34 no.6
    • /
    • pp.411-423
    • /
    • 2020
  • To remove phosphorus from the effluent of public wastewater treatment facilities, hundreds of enhanced phosphorus treatment processes have been introduced nationwide. However, these processes have a few problems including excessive maintenance cost and sludge production caused by inappropriate coagulant injection. Therefore, the optimal decision of coagulant dosage and automatic control of coagulant injection are essential. To overcome the drawbacks of conventional phosphorus removal processes, the integrated sedimentation and dissolved air flotation(SeDAF) process has been developed and a demonstration plant(capacity: 100 ㎥/d) has also been installed. In this study, various jar-tests(sedimentation and / or sedimentation·flotation) and multiple regression analyses have been performed. Particularly, we have highlighted the decision-making algorithms of optimal coagulant dosage to improve the applicability of the SeDAF process. As a result, the sedimentation jar-test could be a simple and reliable method for the decision of appropriate coagulant dosage in field condition of the SeDAF process. And, we have found that the SeDAF process can save 30 - 40% of coagulant dosage compared with conventional sedimentation processes to achieve total phosphorus (T-P) concentration below 0.2 mg/L of treated water, and it can also reduce same portion of sludge production.

Enhancement of anaerobic digestion of sewage sludge by combined process with thermal hydrolysis and separation (하수슬러지 혐기성 소화 효율 향상을 위한 열가수분해-고액분리 결합 공정)

  • Lee, See-Young;Han, Ihn-Sup
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.29 no.4
    • /
    • pp.99-106
    • /
    • 2021
  • The purpose of this study was to evaluate the performance of novel process with thermal hydrolysis and separation as pre-treatment of anaerobic digestion (AD). The dewatered sludge was pre-treated using THP, and then separated. The separated liquid used as substrate for AD and separated solid was returned on THP(Thermal Hydrolysis Process). The degree of disintegration (DD, based on COD) using only THP found 45.1-49.3%. The DD using THP+separation found 76.1-77.6%, which was higher than only THP. As result from dual-pool two-step model, the ratio of rapidly degradable substrate to total degradable substrate found 0.891-0.911 in separated liquid, which was higher than only THP. However, the rapidly degradable substrate reaction constant (kF) of only THP and THP+separation were similar. This results found that dewatered sludge was disintegrated by THP, and then rapidly degradable substrate of hydrolyzed sludge was sorted by separation.

Advanced Treatment of Sewage and Wastewater Using an Integrated Membrane Separation by Porous Electrode-typed Electrolysis (분리막/다공 전극형 전기분해 조합공정을 이용한 하.폐수의 고도처리)

  • Choi, Yong-Jin;Lee, Kwang-Hyun
    • Membrane Journal
    • /
    • v.22 no.2
    • /
    • pp.95-103
    • /
    • 2012
  • To treat nitrate and non-biodegradable organics effectively in sewage, industrial wastewater and livestock wastewater, the activated sludge process integrated by a membrane separation and a porous electrode- electrolysis was proposed and its efficiency was investigated. The proposed system was consisted of 3 processes; activated sludge, membrane filtration and electrolysis. In the study, the membrane filtration played a role in reducing the load of the electrolysis to operate the proposed process stably. The electrolysis consisted of a porous electrode to increase the efficiency due to the extension of the specific surface area. Additionally, redox reaction in the electrolysis was induced by decomposing influent water as current was applied. As a result, hydrogen free radicals and oxygen radicals as intermediates were produced and they acted as oxidants to play a role in decomposing non-degradable organics. It was environmentally-friendly process because intermediates produced by porous electrode were used to treat waste matters without supplying external reagent. Experimental data showed that the proposed process was more excellent than activated sludge process. SS removal efficiencies of the proposed process, membrane filtration and activated sludge process were about 100%, about 100% and about 90%, respectively. COD removal efficiencies of the proposed system, membrane filtration and activated sludge process were about 92%, about 84% and about 78%, respectively. T-N removal efficiencies of the proposed system, membrane filtration and activated sludge process were about 88%, about 67%, and about 58%, respectively. The SS data showed that SS was efficiently removed in the single of the membrane filtration. The COD/T-N data showed that COD/T-N of membrane hybrid process was treated by removing a little soluble organics and SS, and that COD/T-N of electrolysis hybrid process was treated by oxidize organics with high removal rate.

Aquaculture Recycling Effluent from a Pond System Treating Animal Excreta Ecologically (축산폐수 처리 연못시스템의 처리수 재활용 양어)

  • Yang, Hong-Mo
    • Korean Journal of Environmental Agriculture
    • /
    • v.19 no.4
    • /
    • pp.339-344
    • /
    • 2000
  • Utilization of animal excreta in aquaculture can have potentials of high fish production and low maintenance costs for fish farming and it can reduce water pollution caused by animal waste disposal. Integration of wastewater treatment pond system with aquaculture has been utilized in many countries. Ecologically balanced pond ecosystem is formed through the stabilization of wastes, the growth of aquatic plants, and the cultivation of fish. The most appropriate fish for rearing in these ponds are those which can feed directly on phytoplankton, especially algae. Carp were introduced into a tertiary pond - water depth of 2.2 m, water surface area of $130\;m^2$, volume of $148\;m^3$ - of a pond system treating milk cow excreta. The carp production was $125g{\cdot}m^{-2}year^{-1}$ which falls into upper range of $18\;-\;137g{\cdot}m^{-2}year^{-1}$ of treated sewage-fed carp farming of other countries. Average $BOD_5$ and T-N of the pond was 19.8 and $21.0\;mg{\cdot}L^{-1}$ respectively, and the ecological environment of it was suitable for growth of carp. Several carp of 100g were introduced in August into a secondary pond of the treatment system, whose average $BOD_5$ and T-N was 27.9 and $30.8\;mg{\cdot}L^{-1}$ respectively. They were died within one week, which may be attributed to the depletion of dissolved oxygen at dawn. Effluents from primary treatment can be used in fish pond with dilution and those from secondary treatment can be directly funnelled into it. Waste stabilization pond treating animal excreta can be utilized for fish rearing when its water quality maintains secondary treatment level.

  • PDF

Epidemiological Studies on Giardia Infection Associated with environmental Pollution (Giardia에 의한 환경오염(環境汚染)과 감염(感染)에 관한 역학적(疫學的) 연구(硏究))

  • Lee, Keun-Tae;Kim, Seok-Chan;Song, Jong-Sool;Chung, Pyung-Rim
    • Journal of agricultural medicine and community health
    • /
    • v.9 no.1
    • /
    • pp.56-66
    • /
    • 1984
  • Giardia lamblia is a pathogenic flagellate causing intestinal disorders such as diarrhea, abdominal pain and malabsorption of nutrients. Giardia is mainly infected by the ingestion of contaminated foods per os. Craun (1979) has recently reported that mass infection of this flagellate through the contaminated water supply systems is one of public health hazards. Also, so-called traveller's diarrhea is sometimes caused by Giardia infection (CDC, U.S.A., 1971). However, a few epidemiological studies figuring out the mode of infection or control measures of Giardia infection has been done so far in Korea. The present study was aimed to know the prevalence of Giardia infection in several Korean populations, detectability of this flagellate in water systems and the viability of the cysts against sewages and disinfectants applying to drinking water. In the present study, 388 stool specimens from orphanage children in Chun-joo, Chung-joo, On-yang and Chun-an areas and 538 stool specimens from inhabitants in Woo-do, In-chon, and Chun-joo were examined by formalin-ether concentration technique to detect out Giardia cysts. On the other hand, water samples from 14 sites of Han River and its tributaries were collected in May through July, 1984. Fifty liter of water sample in each sampling site was then filtered through water filtering system deviced by U.S. Environmental Proutection Agency and the sediments rinsed out from the thread rolls, a part of water filtering system, were examined to detect out the Giardia cysts. In order to observe the viability of Giardia cysts in the sewage samples, the cysts were treated in it at $4^{\circ}C$ or $25^{\circ}C$ for 7 through 28 days. For this purpose, the cysts were also exposed to various concentrations of disinfectants such as chlorine, iodine and ozone gas for proper time intervals. After treatment, the viability test of the Giardia cysts were carried out by method of Rice and Schaefer (1981) with minor modification. The results obtained in this study were as follows : 1) The detection rates of G lamblia cysts in the stool specimens were 18.3% in orphans and 4.3% in general examinees. 2) The prevalences of Giardia Infection were higher in the young age groups than in-adults. The highest positive rate was 18.4% in the age group less than 10. 3) Of 14 water specimens sampled from Han River system and its tributaries around the Seoul area, the Giardia cysts were detected from 4 samples, and no cyst was found in the water supply systems. 4) The cysts treated in the sewage survived for 28 days at $4^{\circ}C$ and for 13 days at $25^{\circ}C$. 5) The cysts were completely destroyed within 60 minutes by exposure to 8 mg/l of residual chlorine at 4g and within 30 minutes by exposure to the same concentration of chlorine at $25^{\circ}C$. 6) The cysts were all dead when exposed to 1 mg/1 of iodine for 60 minutes at $4^{\circ}C$ or $25^{\circ}C$. 7) The cysts were destroyed after 10 minute exposure in 0.15 mg to 0.25mg of residual ozone gas per liter. Summarizing the above results, it is considered that Giardia infection is regarded as water-borne disease and the cysts are able to be controlled by the application with the disinfectants in the water supply systems.

  • PDF

A Study on the Runoff Characteristics and Water Quality Management of Seung-Gi Stream Area (승기천 유역의 오염물 유출특성 및 수질관리방안 연구)

  • Seo, Hyung-Joon;Chung, Sang-Won;Park, Mi-Ok;Lee, Byung-Ryul
    • Clean Technology
    • /
    • v.7 no.4
    • /
    • pp.251-263
    • /
    • 2001
  • This study was conducted to provide a basic information for recovery plan of Seung-Gi Stream which is a major stream of Incheon metropolitan area. Source and characteristics of pollutants were analyzed and studied. Samples were taken 10 rounds in 5 sections in Seung-Gi stream. Annual pollutants loads and sectional characteristics of pollutants loads were investigated regarding flow rate, pH, DO, SS, $BOD_5$, $COD_{Cr}$, T-P, TKN and concentrations of Zn, Cd, Cu, Cr atoms which enter into Seung-Gi stream during rainy and dry season respectively. As one came close to the Nam-Dong Industrial Complex, sectional discharge loads were heavy and water quality was failed to meet the standard by "Environmental Standard of River Quality". As a result, heavy load of pollutants in Seung-Gi stream was considered to influence negatively the sea water quality of Incheon. Solution plans to solve problems are as follows. First, circulation of treated water at Seung-Gi WWTP(Wastewater Treatment Plant) and retreated water by URC(ultra rapid coagulation) process treat with that. Second, sewage and wastewater is gathered, make it disposed. After then, we circulate treated water. If solution plans be applied, we can predict water quality. Then we could grope for how make to recovery role of Seung-Gi stream as stream.

  • PDF

Explanation of Foaming Mechanism and Experimental Application of Foam Reduction Techniques in the Treated Wastewater Outlet of Wastewater Treatment Plant Connected to a Tidal River, Korea (감조하천에 연결된 하수처리장 방류구의 거품 형성기작 해석 및 거품발생 저감기술의 실험적 현장적용)

  • Shin, Jae-Ki;Cho, Youngsoo;Kim, Youngsung;Kang, Bok-Gyoo;Hwang, Soon-Jin
    • Korean Journal of Ecology and Environment
    • /
    • v.49 no.3
    • /
    • pp.187-196
    • /
    • 2016
  • This study was performed to improve the foaming generated in the effluent of wastewater treatment plant from March 2015 to July 2016. The main cause of foaming was air entrainment by an impinging jet and the internal accumulation by the diffusion barrier. Particularly, the foam growth was most active when there is low tide and larger discharge. To solve this problem, we experimented after installing fine mesh screen and the artificial channel device with underwater discharging outlet in the treated wastewater discharge channel and the outlet, respectively. As a result, the effects of foam reduction by devices ranged 85.0~92.0% and 70.7~85.6%, respectively. In addition, the foam and the noise were easily solved, first of all look to contribute to the prevention of complaints. Our device studies were applied to a single wastewater treatment plant. However, it is considered to be able to apply in other similar cases of domestic sewage treatment plants.

A Preliminary Survey of a Typhoid Epidemic in the City of Samchunpo During 1967 (1967년(年) 삼천포시(三千浦市)에 발생(發生)된 장(腸)지브스유행(流行)에 관(關)한 조사(調査))

  • Ryu, Young-Hai;Kee, Ryong-Sook
    • The Journal of the Korean Society for Microbiology
    • /
    • v.3 no.1
    • /
    • pp.35-41
    • /
    • 1968
  • An outbreak of typhoid fever in Samchunpo city was surveyed and the results were summarized as follows: 1. 638 of clinical cases were detected in 17 Dongs(districts) of the city of Samchunpo,(54,064), during the epidemic period from 1st September to the end of November, 1967. 2. The morbidity rate was 1,189 per 100,000 population;(1,300 female, and 1,060 male). 3. The highest peak was reached in the third week of September and a second peak appeared at the end of September 1967. 4. The mode of infection was suspected strongly as a water-borne and the source of infection as an old public well called Gal-Dae-Saim, since the causative agent was found in close public latrine and the contaminated sewage ditch witch was connected with the well. 5. All patients and carriers were treated at their home under the supervision of local medical authorities. 6. The Gal-Dae-Saim was closed immediately on 7th October, 1967 by the order of the mayor. 7. At the end of November, 1967 when the outbreak in Samchunpo was almost ended, another small epidemic occurred in Koseong county which bordered the eastern outskirt of the city. 8. During the survey, a strain of Shigella flexneri was isolated from the sewage located three meters from Gal-Dae-Saim and also from one case. 9. It was reported by the local health center in May, 1968, that no carrier had been detected in the survey made among the persons who had had typhoid fever in 1967. Also thereafter no cases of typhoid fever were reported through October, 1968.

  • PDF

Spectrophotometric Quantitative Analysis of Cu(II) Ion Using N,N'-bis(4-methoxysalicylidene)phenylendiamine (N,N'-bis(4-methoxysalicylidene)phenylendiamine를 이용한 Cu(II) 이온의 분광학적 분석)

  • Kim, Sun-Deuk;Seol, Jong-Min
    • Journal of the Korean Chemical Society
    • /
    • v.56 no.2
    • /
    • pp.228-235
    • /
    • 2012
  • A $N_2O_2$ Schiff base ligand, N,N'-bis(4-methoxysalicylidene)phenylendiamine (4-$CH_3O$-salphen) was synthesized. Using the 4-$CH_3O$-salphen, the spectrophoto-metric quantitative analysis of Cu(II) ion in aqueous solution was performed. The optimum condition for the quantitative analysis of Cu(II) ion was determined as the following; the concentration of 4-$CH_3O$-salphen is $2.0{\times}10^{-4}\;mol/L$, ratio between solvent DMSO and water is 50/50(v/v), pH is 5.5. After 1 hr water incubation at $55^{\circ}C$ and then the absorbance measurements at 388 nm, a calibration curve (${\varepsilon}=3.6{\times}10^4\;mol^{-1}cm^{-1}$) with a correlation coefficient ($R^2$=0.9963) was obtained in this condition. Using this optimized condition, the quantitative analysis of Cu(II) ion was performed with various samples such as hot spring water, semiconductor factory waste water and treated water from sewage treatment plant. The average value of the measured values agreed well with standard value with a range of 0.6~5.4%. The limit of determination was 31.77 ng/mL ($5.0{\times}10^{-7}\;mol/L$).

Adsorption and Degradation of Alkylbenzenesulfonate by Soils (Alkylbenzenesulfonate의 토양(土壤)에 의한 흡착(吸着)과 분해(分解))

  • Ha, Sang-Keon;Joo, Jin-Ho;Um, Myung-Ho;Lim, Hyung-Sik
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.21 no.2
    • /
    • pp.169-175
    • /
    • 1988
  • A laboratory experiment was conducted to investigate the effects of pH, organic matters and anion on the adsorption and degradation of surfactant by different soils; Anmi series (limestone region), Gangseo series (alluvial soil). For this study, Alkyl Benzene Sulfonate (ABS ; Sodium Dodecylbenzenesulfonate) was used as a surfactant. The results were as follows: 1. Adsorption of ABS by soils was correlated positively with the equilibrium concentration of ABS in a soil suspension. (Anmi seris : r=0.9855, Gangseo series : r=0.9931). 2. Adsorption rate of ABS by soils was about 70% of the treated concentration ($600{\mu}g$ ABS/g soil) in a range of pH 4 to pH 5, and about 20% for pH 8. 3. Addition of electrolytes increased ABS adsorption by soils in a soil suspension; the higher concentration, the higher adsorption. But the influence among electrolytes was not significant. 4. Adsorption of ABS by soils was not affected by soil organic matter content in this experiment. 5. Degradation rate of ABS in a soil suspension was about 85% at $30^{\circ}C$, and about 10 to 15% at $10^{\circ}C$. Addition of sewage accelerated the degradation rate regardless of temperature and reached about 85% in a week.

  • PDF