• Title/Summary/Keyword: Travel Frequency

Search Result 217, Processing Time 0.02 seconds

The Effect of Acupuncture and Electro-acupuncture at ST41 on Experimentally-induced Intestinal Hypo-motility in Rats: Comparison between Pre-treatment and Post-treatment (해계(解谿)(ST41) 유침 및 전침의 전.후처치가 loperamide로 억제된 흰쥐의 장운동에 미치는 영향)

  • Kim, KyungMin;Lee, Hyun;Yim, YunKyoung
    • The Journal of Korean Medicine
    • /
    • v.33 no.3
    • /
    • pp.20-32
    • /
    • 2012
  • Objectives: The purpose of this study was to investigate the effect of acupuncture and electro-acupuncture (EA) of low and high frequencies at Haegye (ST41) in rats. Methods: The intestinal motility of rats was experimentally suppressed with loperamide. Acupuncture, low frequency EA and high frequency EA were carried out before the loperamide administration in the pre-treatment group, and after the loperamide administration in the post-treatment group. The rats were fed charcoal and the travel rate of charcoal in the gastrointestinal track was measured to analyze the effect of acupuncture, low frequency EA and high frequency EA on the intestinal hypo-motility. Results: 1. None of acupuncture, low frequency EA or high frequency EA at ST41 showed significant influences on intestinal motility of rats in normal status. 2. Pre-treatment with acupuncture at ST41 showed no significant effect on the intestinal hypo-motility induced by loperamide in rats. 3. Pre-treatment with low frequency EA and high frequency EA at ST41 significantly reduced the suppression of intestinal motility by loperamide in rats. 4. Post-treatment of acupuncture, low frequency EA and high frequency EA at ST41 had no significant influences on the intestinal hypo-motility induced by loperamide in rats. Conclusions: These results suggest that low and high frequency EA at ST41 may be effective to prevent gastric disorders such as intestinal hypo-motility.

Design and Analysis of High Frequency High Power Density. High Voltage Pulse Transformer for Travel Wave Tube(TWT) High Voltage Power Supply (진행파관 고전압전원공급기의 고주파수, 고밀도, 고전압 펄스변압기의 설계 및 해석)

  • Kim, S.C.;Jung, S.H.;Nam, S.H.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07b
    • /
    • pp.1043-1045
    • /
    • 2002
  • 고전압 전원공급기를 고 밀도로 제작하기 위하여 고 주파수 동작을 시켜야 한다. 이에 따라 전원 공급기에서 최대의 부피를 차지하는 부품인 변압기는 원하는 주파수에서 최소의 부피로 충분한 전력을 수용하면서 완벽한 펄스재현을 하여야 한다. 고전압 전원공급기는 풀-브릿지 DC/DC 컨버트로 구성되어 있으며 스윗칭 주파수는 100 kHz 이다. 변압기는 일차권선이 1개이며 이차 권선은 4개로 구성된다 일차전압은 250 Vdc, 이차 권선 각각의 출력은 520 Vrms이다. 변압의 이차 권선은 배 전압 회로를 이용하여 승압 후 각각을 직렬로 연결하여 -4,100 VDC와 -2,050 VDC를 만들어 TWT(Travel Wave Tube)의 케소드 및 콜렉트에 공급한다. 이 변압기는 100 kHz 펄스로 동작하고 최대부피가 400$cm^3$이하가 되어야 한다. 본 논문에서는 이러한 변압기의 설계 방법 및 최소 온도상승을 위한 적절한 동작 자속밀도의 선택에 대하여 기술하고 변압기의 누설 인덕턴스, 분포 케페시턴스, 공진 주파수에 대하여 설계치 및 실험치를 비교 평가하였다.

  • PDF

Fabrication of magnetic levitation - traveling model using YBCO high Tc superconductor (YBCO 고온초전도체를 이용한 자기부상 주행모델 제작)

  • Oh, S.S.;Ha, D.W.;Lee, E.Y.;Kwon, Y.K.;Cho, J.W.;Nah, W.S.;Jin, H.B.;Han, T.H.;Ryu, K.S.
    • Proceedings of the KIEE Conference
    • /
    • 1994.07a
    • /
    • pp.189-191
    • /
    • 1994
  • YBCO bulks for levitation have fabricated using MPMG method. The superconducting properties and repulsive/attractive force against permanent magnet were investigated for the specimens annealed at various periods after MPMG. A linear induction motor type levitation - traveling vehicle using the pinning force of MPMG processed YBCO bulk has fabricated. The floating or hanging small vehicle mounted with two YBCO pellets was confirmed to travel stabley on the Nd-Fe-B permanent magnet track. The traveling speed of the vehicle was confirmed to depend on AC frequency linearly. At 200 Hz, the travel ins speed was found to be 110 cm/sec.

  • PDF

Intesity and phase Indetificaion of the 13 June 1997 Kyeongju Earthquake (1997년 6월 26일 경주지진의 진도 및 파형분석)

  • 김우한
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 1997.10a
    • /
    • pp.70-81
    • /
    • 1997
  • The intesity survery on the 26 June 1997 Kyeongju Earthquake whose magnitude is 4.3, has been made for 316 locations throughout southen park of Korean Peninsula, then we have investigated the intensities distribution of the earthquake. Because the earthquake was occurred during night time (03:50:23.19), the most people who live farather than about 200km from the epicenter did not feel the earthquake. Therefore, the intensities are estimated only from IV to V in this study. The iso-seismal intensity map shows that the shape of iso-seismal intensity is similar to the boundary of the Kyeongsang Basin. This phenomenon may indicates that the energy of the earthquake is trapped within the Kyeongsang Basin due to low velocity within the basin compared with the velocity outside of the basin. The travel time curves with 10 possible phases are used to identify the earquake records. The Pg and Sg phases are crearly shown in the records whose epicental distance is less than 60 km. The records of MUN and PCH stations located outside of the Kyiongsang Basin show different frequency compared with that of the other stations located within the Kyeongsang Basin.

  • PDF

A Case of Pleural Hydatid Cyst Mimicking Malignancy in a Non-Endemic Country

  • Kim, Se-Joong;Jung, Ki-Hwan;Jo, Won-Min;Kim, Young-Sik;Shin, Chol;Kim, Je-Hyeong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.70 no.4
    • /
    • pp.338-341
    • /
    • 2011
  • Hydatid disease is caused by the larval stage of taenia $Echinococcus$, which endemic in the Mediterranean region. Recently, the prevalence of the disease has increased worldwide due to an increase in the frequency of travel and immigration. As the infested larvae migrate through the bloodstream, the final destination is most commonly the liver or lungs; direct pleural invasion is very rare. A 50-year-old diabetic Korean man presented with an incidentally noted 2 cm right pleural nodule. On follow up imaging after three months, its size had increased. To confirm the diagnosis of the lesion, surgical excision was performed. Histopathological examination showed the diagnosis of a hydatid cyst. The patient had no history of overseas travel, but lives in an urban area where many foreign workers from endemic countries reside. This is the first reported case of primary pleural hydatid disease in a non-endemic country.

Research on Satisfaction Evaluation Based on Tourist Big Data

  • Guo, Hanwen;Liu, Ziyang;Jiao, Zeyu
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.16 no.1
    • /
    • pp.231-244
    • /
    • 2022
  • With the improvement of people's living standards and the development of tourism, tourists have greater freedom in choosing destinations. Therefore, as an indicator of satisfaction with scenic spots, tourist comments are becoming increasingly prominent. This paper aims to compare and analyze the landscape image of the Five Great Mountains in China and provide specific strategies for its development. The online reviews of tourists on the Online Travel Agency (OTA) website about the Five Great Mountains from 2015 to 2018 are collected as research samples. The text analysis method and R language are used to analyze the content of the tourist reviews, while the high-frequency words in the word cloud are used for visual display. In addition, the entropy weight method is used to determine the index weight and tourist satisfaction is evaluated to understand the weaknesses of those scenic spots. The results of the study show that firstly, the tourist satisfaction with the Five Great Mountains is basically consistent with its popularity. Secondly, through weight analysis, tourists pay special attention to the landscape features and environmental health of the scenic area, so that relevant departments should focus on building the landscape characteristics and improving the environmental health of the scenic area. At the same time, the accommodation and service management of the scenic spot cannot be ignored. Finally, according to the analysis results, suggestions are made on how to improve the tourist satisfaction with the Five Great Mountains.

FFT analysis of load data during field operations using a 75-kW agricultural tractor

  • Ryu, Myong-Jin;Chung, Sun-Ok;Kim, Yong-Joo;Lee, Dae-Hyun;Choi, Chang-Hyun;Lee, Kyeong-Hwan
    • Korean Journal of Agricultural Science
    • /
    • v.40 no.1
    • /
    • pp.53-59
    • /
    • 2013
  • Analysis of load data during field operations is highly important for optimum design of power drive lines for agricultural tractor. Objective of the paper was to analyze field load data using FFT to determine frequency and the energy levels of meaningful cyclic patterns. Rotary tillage, plowing, baling, and wrapping operations were selected as major field operations of agricultural tractor. An agricultural tractor with power measurement system was used. The tractor was equipped with strain-gauge sensors to measure torque of four driving axles and a PTO axle, speed sensors to measure rotational speed of the driving axles and an engine shaft, pressure sensors to measure pressure of hydraulic pumps, an I/O interface to acquire the sensor signals, and an embedded system to calculate power requirement. In rotary tillage, calculated frequency was decreased as travel speed increased. In baler operation, calculated frequency was increased as PTO speed was increased. The calculated peak frequency levels and expected levels were similar. Results of the study would provide information on power utilization patterns and on better design of power drive lines.

Train Service Analysis of Intercity Rail Station (지역간 철도역의 열차운행체계 연구)

  • Lee, Jin-Seon;Kim, Gyeong-Tae;Park, Beom-Hwan
    • Journal of Korean Society of Transportation
    • /
    • v.25 no.5
    • /
    • pp.111-122
    • /
    • 2007
  • This paper investigates the rail service patterns by train class. The emphasis in intercity rail planning is to more efficiently use of existing station facilities. Rail transit operations are affected by the system layout and ridership patterns and by work rules. Operations are also influenced by past practices and the institutional setting. Main factors to decide train service patterns are the location, socioeconomic characteristics, land use and travel demand of the station. In this context, the travel demand of intercity rail station is of crucial significance. Tests on a KTX case shows that train service frequency can be efficiently decreased in weekday to transport the same passenger demand. The work has shown many subjects that need further research including various factors influencing on train frequency. This study serves the railroad authorities in planning and determining business strategy in the increasingly competitive environment of regional rail transport.

Attenuation of Coda Wave in the Southeastern Korea (한반도 남동부에서의 Coda파 감쇠)

  • 김성균
    • Economic and Environmental Geology
    • /
    • v.32 no.4
    • /
    • pp.379-384
    • /
    • 1999
  • In order to know the characteristics of attenuation of coda wave in the Kyungsang Sedimetary Basin, quality faclity factor for coda wave (coda Q) is estimated from the earthquake data recorded in the KIGAM local seismic network. Thesingle scattering model for coda wave generation is adopted is adopted in estimating coda Q. In the present study, coda Q(Qc)is estimated in the range of $\alpha$=1.5~3.0, where $\alpha$ denotes the normalized time to S-wave travel time and expressed in terms of frequency (f). The deduced function in the range of 1 to 25 Hz is Qc=36.8283$f^{1.15095}$ which represents the strong dependence of coda Q on frequency. It is found that the difference of Qc between U-D, N-S, and E-W components is negligible. This fact suports the back scattering therory that coda wave originates from scattered waves by randomly distributed heterogenities in the crust On the other hand, it is observed that the coda Q increases with increasing epicentral distence. This observation suggests that QC increases with depth.

  • PDF

A Study for Tubing Pipe Flaw Sizing by Using Guided Ultrasonic Wave (유도초음파기법을 이용한 튜빙 결함측정에 관한 연구)

  • Joo, Kyung Mun;Cheon, Keun Young;Lee, Jeong Seok
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.5 no.1
    • /
    • pp.20-24
    • /
    • 2009
  • There is extensive tubing pipe in the nuclear power plant under high temperature and pressure. Erosion and corrosion defects are expected on this tubing pipe due to environmental and mechanical factors. In this study, Guided Ultrasonic Wave technique was applied to detect defects. The technique explores the advantages of the Guided Ultrasonic Wave method that inspects along the wall of the pipe and can travel long distances, providing rapid collection of data. This paper presents a case study of the Guided Ultrasonic Wave testing of 3/8" tubing pipe. This study offers to understand detected signals through correlation between amplitude and depth of defects.

  • PDF