• Title/Summary/Keyword: Transverse and longitudinal distance

Search Result 44, Processing Time 0.021 seconds

Seismic loss-of-support conditions of frictional beam-to-column connections

  • Demartino, Cristoforo;Monti, Giorgio;Vanzi, Ivo
    • Structural Engineering and Mechanics
    • /
    • 제61권4호
    • /
    • pp.527-538
    • /
    • 2017
  • The evaluation of the loss-of-support conditions of frictional beam-to-column connections using simplified numerical models describing the transverse response of a portal-like structure is presented in this paper considering the effects of the seismic-hazard disaggregation. Real earthquake time histories selected from European Strong-motion Database (ESD) are used to show the effects of the seismic-hazard disaggregation on the beam loss-of-support conditions. Seismic events are classified according to different values of magnitudes, epicentral distances and soil conditions (stiff or soft soil) highlighting the importance of considering the characteristics of the seismic input in the assessment of the loss-of-support conditions of frictional beam-to-column connections. A rigid and an elastic model of a frame of a precast industrial building (2-DoF portal-like model) are presented and adopted to find the minimum required friction coefficient to avoid sliding. Then, the mean value of the minimum required friction coefficient with an epicentral distance bin of 10 km is calculated and fitted with a linear function depending on the logarithm of the epicentral distance. A complete parametric analysis varying the horizontal and vertical period of vibration of the structure is performed. Results show that the loss-of-support condition is strongly influenced by magnitude, epicentral distance and soil conditions determining the frequency content of the earthquake time histories and the correlation between the maxima of the horizontal and vertical components. Moreover, as expected, dynamic characteristics of the structure have also a strong influence. Finally, the effect of the column nonlinear behavior (i.e. formation of plastic hinges at the base) is analyzed showing that the connection and the column are a series system where the maximum force is limited by the element having the minimum strength. Two different longitudinal reinforcement ratios are analyzed demonstrating that the column strength variation changes the system response.

노면 종.횡단 요철 자동 측정 시스템 개발 (Development of an Automatic Transverse and Longitudinal Road Profile Measurement System)

  • 엄정현;서동선;허웅;류명찬;김준범
    • 전기전자학회논문지
    • /
    • 제5권1호
    • /
    • pp.75-84
    • /
    • 2001
  • 도로 노면상태와 관련된 신뢰성 있는 데이터는 도로 유지 및 관리 당국과 운전자에게 도로 노면상태에 대한 정보를 제공하기 위해 그 중요성이 날로 증대하고 있다. 본 논문은 새로운 고속의 자동 노면 데이터 획득장치의 개발에 관한 것이다. 개발된 장치는 100km/h의 주행속도에서 도로노면 청단 전체 폭에 대해 30cm 간격으로 종단 노면 데이터를 수집하고, 수집된 데이터로부터 국제평탄성지수(IRI)를 계산하여 노면요철 데이터와 함께 스크린상에 디스플레이 한다. 이 같은 시스템의 구현을 위해 광학적 거리측정기, 계측차량의 진행거리 및 움직임 계측기, 데이터 처리 및 디스플레이 모듈을 고안하였다. 70km/h의 주행 속도로 측정한 결과, 개발된 시스템의 측정 정확도는 표준 노면에 대해 IRI에서 ${\pm}0.1m/km$ 정도의 오차를 보이는 것으로 나타났다. 또한, 개발된 장비의 성능을 검증하기 위해 이미 포설된 노면에 대한 측정을 수행하여 기존 장비 및 육안 측정 결과와 비교하였다.

  • PDF

마사치오의 "삼위일체" 벽화에서 나타난 공간적인 특성에 관한 연구 (A Study on the Spatial Characteristics from the "The Holy Trinity" Fresco Painted by Masaccio)

  • 김석만
    • 건축역사연구
    • /
    • 제22권6호
    • /
    • pp.7-22
    • /
    • 2013
  • The purpose of this paper is to study on the spatial characteristics from the "The Holy Trinity" fresco painted by Masaccio in the early Renaissance paintings. The results of this study are as follows. 1. The elevation composition of the "The Holy Trinity" fresco is divided into the upper and lower structure through horizontal axis on horizontal line around vanishing point. The upper structure is composed of vertical axis formed through the disposition of the "Trinity" elements and horizontal axis on horizontal line. The lower structure is composed of the sarcophagus and skeleton in such inside and the altar supported through circular columns of left and right. 2. The section composition of the "The Holy Trinity" fresco is composed of the ceiling structure of cylindrical-shaped vault on upper part around basic square floor plan that is interior space and upper structure. The exterior space and lower structure is placed with sarcophagus in inner part that altar and step is projected as same height and width in the outside direction. 3. The basic floor composition of the "The Holy Trinity" fresco is planned by square shape around structural columns that is placed at corners as symmetry through transverse, longitudinal and diagonal axis. The whole floor composition planned through the altar and step that is in exterior space at front, the apse of round form at rear part and the structure of the middle story concept at interior. 4. The visual aspect of the "The Holy Trinity" fresco is composed of the stable balance in relation with distance and height because the interior and exterior space as well as the upper structure and lower structure is formed by regular proportion system. The elevation angle of visual range was planned to view in detail generally or partially the architectural composition system and element, characters through proper visual distance, center and position.

지하 복합발전 플랜트 내에서의 가스 누출 및 확산 거동에 관한 수치해석 연구 (Numerical Analysis of Gas Leakage and Diffusion Behavior in Underground Combined Cycle Power Plant)

  • 방주원;이성혁
    • 한국산학기술학회논문지
    • /
    • 제18권4호
    • /
    • pp.118-124
    • /
    • 2017
  • 본 연구에서는 상용코드인 Fluent(v.17.1)을 사용하여 수치해석을 진행하였으며, 지하복합발전 플랜트의 형상을 단순화하여 파공 크기 및 파공 위치에 따른 가스 누출에 관한 해석을 진행하였다. 누출 가스는 메탄으로 설정하였다. 파공 크기는 10 mm, 20 mm로 설정하였으며, 파공 위치는 파이프 엘보우 부근, 가스터빈 부근에서 가스가 누출될 경우로 가정하여, 총 4가지 Case에 대해 비교 및 분석을 진행하였다. 가스 누출을 분석하기 위해 연소 하한계의 개념을 바탕으로 누출 거리를 정의하여 종 방향, 횡 방향으로의 거리를 추정하여 정량적으로 분석하였다. 결과적으로 동일 위치에서 파공 크기에 따라 누출거리가 최대 52.3 %의 차이를 보이며 종 방향의 누출 거리가 달라지는 것을 알 수 있었다. 그리고 동일 파공 크기일 때, 파공 위치에 따라 최대 34.8 %의 차이를 보이며 가스의 확산 경향이 달라지게 된다. 공기보다 가벼워 부력의 영향으로 상승하던 가스가 장애물로 인해 수평방향으로 확산이 제한되어 장애물이 없는 경우보다 재순환이 빨라지게 된다. 따라서 종 방향 누출거리와 횡 방향 누출거리가 파공 크기 및 파공 위치에 따라 다른 성장 거동을 보인다. 이와 같은 결과는 지하 복합발전 플랜트와 같은 밀폐공간에서 가스 센서의 위치 및 개수를 최적화 하는데 유용한 데이터가 될 것으로 보인다.

N-365 다목적팬텀에서 초음파진단장치의 음속변화 효과 (The Effect of Acoustic Velocity of Ultrasonographic Equipment Using an N-365 Multipurpose Phantom)

  • 김연민;심재구;김상현
    • 한국방사선학회논문지
    • /
    • 제11권4호
    • /
    • pp.221-225
    • /
    • 2017
  • 초음파영상 진단장치의 성능을 평가할 때, 초음파장비에서 제공하는 음속변화 파라메타를 변화시킴에 따른 공간분해능의 변화를 알아보고자 하였다. 익산 소재 A기관에서 사용중인 초음파 진단장치에서 3.0 ~ 5.0 MHz 볼록형 탐촉자를 이용하여 초음파팬텀영상를 얻었다. N-365 다목적 초음파팬텀으로 종거리 측정정확도, 종 횡 해상도를 측정하였다. 같은 방법으로 초음파장치의 음속을1580 m/sec부터 1400 m/sec 까지 6단계로 변화시켜 측정 값의 차이가 있는지 image J 프로그램을 이용하여 반치폭을 측정하였다. 측정 결과, 횡측해상도는 속도변화에 따라 1.91 mm ~ 5.3 mm까지 측정되었으며, 음속 1420 m/sec 일 때 반치폭 1.91 mm로 가장 작게 측정되었다. 종측해상도는 1.03 mm ~ 1.14 mm까지 측정되었으며, 음속 1400 m/sec 일 때 반치폭 1.03 mm 로 가장 작게 측정되었다. 초음파장치의 음속이 느려질수록 종측정 길이가 짧아지는 상관관계를 보였다.

Semicircular Horizontal Approach in Breast Reduction: Clinical Experience in 38 Cases

  • Shin, Hee Su;Lee, Yong Hae;Jung, Sung Gyun;Lee, Doo Hyung;Roe, Young;Cha, Jong Hyun
    • Archives of Plastic Surgery
    • /
    • 제42권4호
    • /
    • pp.446-452
    • /
    • 2015
  • Background Various techniques are used for performing breast reduction. Wise-pattern and vertical scar techniques are the most commonly employed approaches. However, a vertical scar in the mid-lower breast is prominent and aesthetically less pleasant. In contrast, a semicircular horizontal approach does not leave a vertical scar in the mid breast and transverse scars can be hidden in the inframammary fold. In this paper, we describe the experiences and results of semicircular horizontal breast reductions performed by a single surgeon. Methods Between September 1996 and October 2013, our senior author used this technique in 38 cases in the US and at our institution. We used a superiorly based semicircular incision, where the upper skin paddle was pulled down to the inframammary fold with the nipple-areola complex pulled through the keyhole. Results The average total reduction per breast was 584 g, ranging from 286 to 794 g. The inferior longitudinal pedicle was used in all the cases. The average reduction of the distance from the sternal notch to the nipple was 13 cm (range, 11-15 cm). The mean decrease in the bra cup size was 1.7 cup sizes (range, a decrease of 1 to 3). We obtained very satisfactory results with a less noticeable scar, no complication such as necrosis of the nipple or the skin flap, wound infection, aseptic necrosis of the breast tissue, or wound dehiscence. One patient had a small hematoma that resolved spontaneously. Conclusions This technique is straightforward and easy to learn, and offers a safe, effective, and predictable way for treating mammary hypertrophy.

Elastic local buckling behaviour of corroded cold-formed steel columns

  • Nie Biao;Xu Shanhua;Hu WeiCheng;Chen HuaPeng;Li AnBang;Zhang ZongXing
    • Steel and Composite Structures
    • /
    • 제48권1호
    • /
    • pp.27-41
    • /
    • 2023
  • Under the long-term effect of corrosive environment, many cold-formed steel (CFS) structures have serious corrosion problems. Corrosion leads to the change of surface morphology and the loss of section thickness, which results in the change of instability mode and failure mechanism of CFS structure. This paper mainly investigates the elastic local buckling behavior of corroded CFS columns. The surface morphology scanning test was carried out for eight CFS columns accelerated corrosion by the outdoor periodic spray test. The thin shell finite element (FE) eigen-buckling analysis was also carried out to reveal the influence of corrosion surface characteristics, corrosion depth, corrosion location and corrosion area on the elastic local buckling behaviour of the plates with four simply supported edges. The accuracy of the proposed formulas for calculating the elastic local buckling stress of the corroded plates and columns was assessed through extensive parameter studies. The results indicated that for the plates considering corrosion surface characteristics, the maximum deformation area of local buckling was located at the plates with the minimum average section area. For the plates with localized corrosion, the main buckling shape of the plates changed from one half-wave to two half-wave with the increase in corrosion area length. The elastic local buckling stress decreased gradually with the increase in corrosion area width and length. In addition, the elastic local buckling stress decreased slowly when corrosion area thickness was relatively large, and then tends to accelerate with the reduction in corrosion area thickness. The distance from the corrosion area to the transverse and longitudinal centerline of the plate had little effect on the elastic local buckling stress. Finally, the calculation formula of the elastic local buckling stress of the corroded plates and CFS columns was proposed.

경암층 발파현장에서 진동예측 및 장약량산정 (Vibration Prediction and Charge Estimation in Hard Rock Blasting Site)

  • 박연수;박선준;최선민;문수봉;문병옥;정경열;정태형;황승일;김민중;박상철;김정주;이병근
    • 한국소음진동공학회논문집
    • /
    • 제19권3호
    • /
    • pp.313-319
    • /
    • 2009
  • The blasting has a lot of economic efficiency and speediness but it can damage to a neighbor structure, a domestic animal and a cultured fish due to the blasting vibration, then the public grievance is increased. Therefore, we need to manage the blasting vibration efficiently. The prediction of the correct vibration velocity is not easy because there are lots of different kinds of the scale of blasting vibration and it has a number of a variable effect. So we figure the optimum line through the least-squares regression by using the vibration data measured in hard rock blasting and compared with the design vibration prediction equation. As a result, we confirm that the vibration estimated in this paper is bigger than the design vibration prediction equation in the same charge and distance. If there is a Gaussian normal distribution data on the left-right side of the least squares regression, then we can estimate the vibration prediction equation on reliability 50%(${\beta}=0$), 90%(${\beta}=1.28$), 95%(${\beta}=1.64$). 99.9%(${\beta}=3.09$). As a result, it appears to be suitable that the reliability is 99% at the transverse component, the reliability 95% is at the vertical component, the reliability 90% is at the longitudinal component and the reliability is 95% at the peak vector sum component.

콘크리트포장의 노면 잔류 이물질에 따른 미끄럼저항변화 (Skid Resistance Change by Dirt Material on Road Surface of Concrete Pavement)

  • 이승우;김남철
    • 한국도로학회논문집
    • /
    • 제6권4호
    • /
    • pp.35-43
    • /
    • 2004
  • 미끄럼저항은 자동차의 타이 어 와 포장노면 사이에서 발생하는 미끄러짐을 방지하여 제동거리를 제어하고 주행 안전성을 확보하는데 중요한 역할을 한다. 우천시의 미끄럼저항 감소는 치명적인 교통사고를 유발할 수 있다. 노면위에 남은 토사 및 겨울철 제설재는 미끄럼저항을 감소시킬 수 있는 요소가 될 수 있다. 본 연구에서는 노면상의 잔류하는 이물질이 타이어와 포장노면사이에서 발생하는 미끄럼저항에 미치는 영향을 다양한 콘크리트 노면조직 형태 (횡방향타이닝, 종방향타이닝, 골재노출) 및 노면조직의 마모조건(신설노면, 마모된 노면)에 대하여 검토하였다. 노면상의 이물질로는 모래, 염화칼슘과 자동차에서 발생하는 폐 오일을 사용하였으며 각 경우별로 이물질의 양을 달리하여, 모래의 경우는 입도 및 양을 달리해가며 미끄럼저항에 미치는 영향을 검토하였다.

  • PDF

복합토양층의 불포화대와 포화대에서 연속주입 추적자시험을 이용한 수리분산특성 연구 (A Study of Hydrodynamic Dispersions in the Unsaturated and the Saturated Zone of a Multi-soil Layer Deposit Using a Continuous Injection Tracer Test)

  • 정상용;강동환;이민희;손주형
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제11권4호
    • /
    • pp.48-56
    • /
    • 2006
  • 여러 개의 층으로 구성된 토양층에서 연속주입 추적자시험을 수행하여, 불포화대와 포화대 구간에서의 수리분산특성 차이를 추적자의 농도이력곡선, 시간에 따른 농도변화 및 농도변화율, 그리고 거리에 따른 농도비 분석을 통해 비교 연구하였다. 연속주입 추적자시험에 의하면, 약 160시간이 경과된 후에 불포화대와 포화대에서 Rhodamine WT 최대농도의 차이는 약 $13{\sim}15$배 정도에 달하였고, 시험시간 대 추적자 농도증가율의 차이는 약 10배 정도로 나타났다. 또한 시간에 따른 추적자 농도이력곡선의 변화와 농도변화율이 불포화대에 비하여 포화대에서 크게 나타났다. 주입공에서의 이격거리에 따른 추적자의 농도비는 포화대 구간에서 더 빠르게 선형적으로 감소하였으며, 그 이후에 농도비가 2배 이하로 완만해 지는데 걸린 시간은 포화대 구간이 더 길었다. 이러한 차이들은 여러 개의 층서로 구성된 토양층의 포화대에서는 지하수가 존재하며, 또한 매질의 불균질성이 크고 투수성이 다양하기 때문에, 비교적 균질한 층서를 이루는 불포화대에 비하여 추적자 용액의 농도는 낮고, 추적자의 확산이 느리게 진행되어진데서 기인하였다. 그리고 포화대 구간에서의 유효공극율은 $10.19{\sim}10.50%$, 종분산지수는 $0.80{\sim}l.98m$, 횡분산지수는 $0.02{\sim}0.04m$의 범위로 산정되었으며, 실내주상시험의 종분산지수와 비교할 때 12배 이상의 규모종속효과가 나타났다.