• 제목/요약/키워드: Transportation Noise

검색결과 353건 처리시간 0.024초

서울시 초고층 아파트의 외부소음 측정과 평가 (Survey and Evaluation for Exterior Noise of a High Rise Apartment in Seoul)

  • 이선동;박유라;이상우;유호천
    • KIEAE Journal
    • /
    • 제4권3호
    • /
    • pp.95-101
    • /
    • 2004
  • As a part of acoustical design, it is often necessary to quantify aspects of an existing environment and to predict the result of adding an acoustical treatment. The most common sources of exterior noise, also termed as environmental noise,(or community noise) are traffic noise, air craft noise, industrial noise, etc. Transportation(air, road, and rail)noise is the dominant and most common source of noise exposure in residential neighborhoods, and the annoyance is its most consequential effect. The road traffic noise becomes aggravated due to the rapid increase of vehicles. It has a great effect on the dwelling environment. Therefore we investigate the characteristics and sources of the road traffic noise through grasping the status of the road traffic noise. In the present study, preceding studies investigated the noise level of urban areas in Seoul were reviewed and the noise level of urban areas in Seoul was measured at first, fifth, tenth, and nineteenth floor for two days of weekdays and two days of weekend.

음향근사기법을 이용한 고속철도 판토그래프의 공력소음 예측 (Prediction of Aerodynamic noise of Pantograph on a high-speed train using the Acoustic Analogy)

  • 한재현;김태민;김정태;김정수
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 정기총회 및 추계학술대회 논문집
    • /
    • pp.150-157
    • /
    • 2011
  • Nowadays, high speed train has settled down as a fast and convenient environment-friendly transportation and it's need is gradually increasing. However increased train speed leads to increased aerodynamic noise, which causes critically affects comfortability of passengers. Especially, the pantograph of high speed train is protruded out of train body, which is the main factor for increased aerodynamic noise. Since aerodynamic noise caused pantograph should be measured in high speed, it is difficult to measure it and to analysis aerodynamic noise characteristics due to the various types of pantograph. In this research, aerodynamic noise of pantograph is predicted by CFD (Computational Fluid Dynamic) and FW-H (Ffowcs Williams-Hawkings) equation. Also, Wind tunnel test results and numerical simulation results were compared. As a result, Simulation results predicting sound pressure level is very similar with wind tunnel test result. This research will draw major factor in aerodynamic noise of pantograph and will be utilized for predict sound pressure level of pantograph.

  • PDF

공동주택 외부소음 현장측정방법 (Field Measurements of Exterior Noise at Apartment Houses)

  • 송민정;정성수;장길수;김선우
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 추계학술대회논문집
    • /
    • pp.359-362
    • /
    • 2005
  • Road traffic noise level and railway noise level are important factors on apartment inhabitant's comforts. The measurement methods which noted by Ministry of Construction & Transportation(MOCT) and Ministry of Environment(ME) are used for measurement of exterior noise at apartment houses. But these methods are out of date because the height of apartment houses have increased dramatically and owing to the sampling methods of the measurement time interval, rating values are induced differently due to sampling methods. In this study, the sound level of each floor of apartment houses is measured and compared. And rating value due to sampling methods are compared. As a result, the KS outline of 'Field Measurement of Exterior Noise at Apartment Housess' is suggested.

  • PDF

고속철도 판토그래프의 공력소음 기여도 연구 (Prediction of the Aerodynamic Noise Generated by Pantograph on High Speed Trains)

  • 한재현;김태민;김정태
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2013년도 춘계학술대회 논문집
    • /
    • pp.425-431
    • /
    • 2013
  • Nowadays, high speed train has settled down as a fast and convenient environment-friendly transportation and it's need is gradually increasing. However increased train speed leads to increased aerodynamic noise, which causes critically affects comfortability of passengers. Especially, the pantograph of high speed train is protruded out of train body, which is the main factor for increased aerodynamic noise. Since aerodynamic noise caused pantograph should be measured in high speed, it is difficult to measure it and to analysis aerodynamic noise characteristics due to the various types of pantograph. In this research, aerodynamic noise of pantograph is predicted by CFD (Computational Fluid Dynamic) and FW-H (Ffowcs Williams-Hawkings) equation. Also, Wind tunnel test results and numerical simulation results were compared. As a result, Simulation results predicting sound pressure level is very similar with wind tunnel test result. To analyze contribution of the pantograph to the noise of high-speed train, simulation results compared with measurement results of exterior noise. The simulation reuslts found that pantograph is a dominant noise source of high-speed trains's exterior noise in low frequency section. This dominant noise was come out from vortex shedding of the panhead in the pantograph. This research will be utilized for reduce sound pressure level of pantograph.

  • PDF

A Study on the Sustainability of Compact Cities in Korea

  • Sun-Ju, KIM
    • 융합경영연구
    • /
    • 제11권2호
    • /
    • pp.13-22
    • /
    • 2023
  • Purpose: The purpose of this study is to examine the policy implications of establishing a compact city in Seoul, analyzing whether it is an appropriate and efficient eco-friendly housing supply alternative. Research design, data, and methodology: The analysis criteria include efficiency, safety, and comfort, with efficiency encompassing economic, energy, and public transport links' efficiency. Safety and comfort are aspects of eco-friendliness, housing safety, and improvement in living environments. Results: In terms of economic efficiency, compact cities are a less expensive option than purchasing land for housing construction. To increase energy efficiency, we plan to adopt eco-friendly energy sources. Transportation efficiency is high in locations near public transport stations. To enhance safety and comfort, we intend to create large-scale parks and forests in Seoul. To ensure residential safety, measures will be taken to reduce road vibration, vehicle noise, and scattering dust. Conclusions: Selecting an appropriate location that provides convenient public transportation is essential for creating a compact city for housing in a large city. Combining a compact and smart city is necessary, and implementing smart technologies is needed to prevent dust, noise, and vibrations, which are undesirable in a residential environment.

항공기 소음 측정 시 이동측정지점에 대한 소음도 예측방법 (A Noise Prediction Method on the Movement Measuring Points at Measurement for Aircraft Noise)

  • 우정하;이병찬
    • 한국소음진동공학회논문집
    • /
    • 제25권12호
    • /
    • pp.901-906
    • /
    • 2015
  • It is difficult to measure aircraft noise at many points, because the noise measurement is need to long time, 24 hours and consecutive 7 days, which results in high costs. As an alternative, movement measuring points are set to measure aircraft noise for less than 24 hours, and so it is needed to overcome the limitation of shorter measuring time. Thus, this study measured military aircraft noise on movement measuring points and conducted a comparative analysis on the data according to each measuring time. The data of measuring noise for 24 hours and less than 24 hours were compared to suggest appropriate measuring time on the movement measuring points. As a result of comparing data of measuring noise, an error was within 3 dB in case of measuring time of 3 hours, and an error was within 1 dB in case of 6 hours of measurement.

방음벽 상단소음저감장치의 성능평가 방법에 관한 연구(2) - 음압레벨에 의한 평가 - (Estimation Method of Noise Reducing Devices Installed on the Noise Barrier(2) - Estimation by Sound Pressure Level -)

  • 김철환;장태순;이기정;김동준;정태량;장서일
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 추계학술대회논문집
    • /
    • pp.1125-1128
    • /
    • 2007
  • In order to improve the acoustic performance of a noise barrier without increasing its height, various type of acoustic devices are suggested but, there is no proper method to estimate the performance in Korea. For this, an outdoor test facility was established in Expressway and Transportation Technology Institute(ETTI) of Korea Expressway Corporation for testing the acoustical performance of noise reducing devices installed on the top of a noise barrier. Noise measurements before and after installation of the noise reducing devices were carried out by using sound pressure level for long distance range from the barrier, from 10m to 40m. For considering the directivity effects of noise reducing devices, multivariate regression analysis was attempted.

  • PDF

도심환경교통(Urban Air Mobility, UAM) 도입에 따른 소음 문제에 대한 시론 -UAM 소음의 특성과 잠재적 건강영향: 연구 방향 및 관리를 위한 정책적 고려사항- (Perspectives on Noise Issues Arising from the Introduction of Urban Air Mobility (UAM) -Characteristics and Potential Health Effects of UAM Noise: Research Directions and Policy Considerations-)

  • 함승헌
    • 한국환경보건학회지
    • /
    • 제50권2호
    • /
    • pp.81-82
    • /
    • 2024
  • Urban air mobility (UAM) is emerging as an innovative transportation solution for cities. However, the potential noise impact on urban life must be carefully examined. Continuous exposure to UAM noise, with its unique frequency characteristics and temporal variability, may adversely affect citizens' health by causing sleep disorders, cardiovascular disease, and cognitive impairmenet, particularly in children. NASA has formed a UAM Noise Working Group to study this issue comprehensively. In Korea, the Seoul Metropolitan Government's UAM demonstration project is expected to accelerate related research and development. Scientific analysis, including noise measurement, prediction modeling, and health impact assessment, must be prioritized. Measures to minimize noise should be established based on this evidence, such as optimizing flight modes, developing noise reduction technologies, and establishing new noise management standards. Transparency and social consensus are crucial throughout this process. Expert review and open communication with civil society are necessary to address related concerns. Sharing demonstration project results and providing opportunities to experience UAM noise through digital twin simulations can help address public concerns and build social consensus. Proactively and scientifically tackling noise issues is essential for the sustainable development and successful integration of UAM into daily life.

자동차 뒷 창문 개방에 의한 공명소음 전산해석 연구 (COMPUTATIONAL ANALYSIS ON DRONE NOISE OF AN AUTOMOBILE WITH OPENED REAR WINDOW)

  • 배익현;문영준
    • 한국전산유체공학회지
    • /
    • 제18권2호
    • /
    • pp.26-34
    • /
    • 2013
  • In modern days, automobiles are the most important means of transportation. With the development of automobiles, noises generated during operation has been recognized as a significant factor of performance to provide drivers with better driving environment along with other passengers. In this study, drone noise(pulsating noise), generated at the rear window when its opened, is predicted to understand the physics of its phenomenon at various velocities. The compressible Navier-stokes equation will be used with $6^{th}$ order compact finite difference scheme to analyze the characteristics.

환경진동의 전달경로 대책 (A Plan on Propagation Process of Environment Vibration)

  • 이성호;이주원;정갑철
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2001년도 춘계학술대회논문집
    • /
    • pp.635-641
    • /
    • 2001
  • This study introduces the basic concepts of the vibration reducing methods and presents a case study of 'A' apartment construction site which located nearby railroad. The site is only 60m away from the railroad. Therefor much noise and vibration damages could be expected during train or any other transportation's passing. Especially, the first and second floor may suffer much vibration with the low frequency radiation noise from the walls and floors. This study estimates the noise level of indoor area by measuring the vibration of indoor walls and floors. From this result, vibration barrier, as a method to reduce the noise level which exceeds proper standard value, was attempted to protect vibration transmit from the railroad.

  • PDF