• Title/Summary/Keyword: Transmission-Loss

Search Result 2,307, Processing Time 0.033 seconds

Improvement of Sound Transmission Loss of Ship's Bulkhead at Low Frequency Range (선박 격벽의 저주파수 대역 차음성능 향상에 관한 연구)

  • Kim, Sung-Hoon;Joo, Won-Ho;Bae, Jong-Gug
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2009.10a
    • /
    • pp.167-168
    • /
    • 2009
  • The noise sources in ship and offshore structure have an influence on adjacent receiving area through a partition between noise sources and receiving area. The partition in ship is usually made of stiffened plate. Sound transmission loss (STL) of the partition at high frequency could be improved by additional installation of insulation or wall panel. At low frequency, however, it is very difficult and needs an increase of plate thickness which causes a considerable weight increase of ship. In this paper, we have investigated the effect of the bulkhead boundary condition. From measurement result, we found that the bulkhead boundary condition can affect a lot in STL, especially at low frequency range. Finally, we get the 5dB increase in STL through the modification of boundary condition.

  • PDF

A Study on the Acoustic Performance Design Technique of Underwater Acoustic Material (수중 음향재료의 음향성능 설계기법 연구)

  • Seo, Youngsoo;Ham, Ilbae;Jeon, Jaejin
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.23 no.10
    • /
    • pp.920-927
    • /
    • 2013
  • The requirement of acoustic performance about underwater acoustic material which is used in underwater environment more increases. Underwater acoustic material was made by viscoelastic material such as a rubber and a polyurethane etc. In order to increase an acoustic performance, several kinds of inclusions were added to viscoelastic material. In this paper, acoustic modelling and analysis techniques were introduced and the acoustic characteristics of underwater acoustic material were studied. Echo reduction and transmission loss were calculated with volume fraction of inclusion in the material. Also the characteristic impedance and the input impedance of underwater acoustic material were obtained and effects on the echo reduction and transmission loss of material were discussed.

Noise Reduction Performance of a Reactive type Silencer with Perforated Panels (다공판이 내장된 반사형 소음기의 소음저감 성능)

  • Lee, Sun-Ki;Lee, Young-Chul;Song, Hwa-Young;Lee, Dong-Hoon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.1415-1418
    • /
    • 2007
  • When a high voltage COS fuse becomes a short circuit by the over current, the impulse noise over 150 dB(A) with the strong pulse jet is radiated from the COS fuse of an electric transformer. For the purpose of the impulse noise reduction, in this study, a reactive type silencer with perforated panels are considered. The transmission loss of the silencer are calculated by transfer matrix method. The effect of the porosity, the distance between panels, and the number of perforated panel on the sound transmission loss is investigated and discussed.

  • PDF

Muffler Design Using Transmission Loss Prediction Considering Heat and Flow (열과 유동을 고려한 음장해석을 통한 머플러의 설계)

  • Kim, Hyunsu;Kang, Sang-Kyu;Lim, Yun-Soo
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.24 no.8
    • /
    • pp.600-605
    • /
    • 2014
  • Two mufflers for a large-size sedan are suggested aiming (1) sporty-sound and (2) quiet-sound as well as both satisfying low back-pressure and low manufacturing cost. Transmission loss prediction considering heat and flow may increase the accuracy and reduce the development cost in muffler design; thus, GT-power prediction considering heat, flow, and acoustics is utilized. By understanding the fundamentals of flow-acoustic theory in small orifice(hole), an effective muffler design concept is proposed. Vehicle tests show the consistence with predictions for sound; also a back-pressure test bench confirms the advantage in pressure drop for both suggested mufflers. Those suggested mufflers also have advantages in manufacturing cost due to simplicity of the design.

Analysis of Acoustic Characteristics of Muffler including Flow effects (유체유동을 포함한 소음기의 음향 특성 해석)

  • Kim, Hyung-Tae;Jeong, Weu-Bong;Kim, Heui-Won
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.11a
    • /
    • pp.861-864
    • /
    • 2006
  • In general, 4-pole parameter and three-point method are used for predicting transmission loss which is one of characteristics of Muffler using CAE tools. However, these mehtods show different results from experiment when the flow effects are presented in practical model. In this parer, to overcome these problems, both Fluent and.Sysnoise are used to analyze the performance of extended inlet/outlet muffler including flow effects with varying flow velocity at inlet of duct. Flow fields and quadrupole source is calculated by Fluent. And Sysnoise is used to analyze acoustic performances of muffler with quadrupole source data extracted from Fluent. Finally, the variation of transmission loss is estimated according to various inlet flow velocity.

  • PDF

Partial Discharge Electromagnetic Wave Penetration Characteristics Throughout Transformer Winding (전자기파 부분방전 신호의 권선 투과 특성)

  • Ju, Hyung-Jun;Han, Ki-Son;Yoon, Jin-Yul
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.23 no.10
    • /
    • pp.809-813
    • /
    • 2010
  • Frequency domain measurement of propagation loss for ultra high frequency (UHF) partial discharge in the winding of power transformer using a spectrum analyzer and pulse generator is presented. We compared the performance of the method using a network analyzer with and without a winding. Using a network analyzer simplifies the measurement and offers better dynamic range and frequency range. It also provides precise propagation loss within the winding in frequency domain at UHF range. We applied this method to measure UHF propagation loss of transformer mock-up, modeled 154 kV 20 MVA power in KEPCO substation.

Design of Variable Power Distributor and Waveguide Connecting Structure for Wireless Microwave Power Transmission in a Building (실내 마이크로파 배전 전송계를 위한 가변전력분배기와 도파관의 결합구조 설계)

  • Choi, Young-Kyu
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.10
    • /
    • pp.1477-1482
    • /
    • 2012
  • This paper deals with a new variable microwave power distributor and a connector between a deck plate and a input power waveguide for indoor microwave wireless power transmission. We design a new type connector built in the 3-stage coaxial line structure, and calculate the return loss of the connector at 2.45GHz. Newly designed connector shows the excellent return loss performance less than -30dB at the operating frequency of 2.45GHz. And we show a power distributor in which the dividing ratio of the power is controlled mechanically by three rotary fins. The distributor can control the dividing power from 4.5% to 58% with the variance of 5% output power. The experimentally tested results of the distributor are good agreement with the simulation within the return loss of 1%.

A measuring technology of the absorption ratio and the transmission loss using the tube method (관내법을 이용한 흡.차음 성능 측정방법)

  • 이장명;김동률
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1998.04a
    • /
    • pp.659-663
    • /
    • 1998
  • To measure the absorption ratio and the transmission loss of a material, a usage of the reverberation room has been popular. However, the reverberation room is expensive to build it and, sometimes, test procedure is not easy. Therefore, to get the data of absorption ratio, several possible technologies has been proposed using the tube. Among these technologies, with the analysis of the spectral density, a convenient method has been introduced to measure both the absorption ratio and transmission loss. The measured data has been compared with the results of the measurement at the reverberation room.

  • PDF

Exhaust Noise Reduction of Dry vacuum Pump (건식진공펌프의 배기 소음 저감)

  • Ahn, Young-Chan;Lee, Hae-Jin;Lee, Jung-Yoon;Yang, Jung-Jik;Oh, Jae-Eung
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.05a
    • /
    • pp.349-354
    • /
    • 2007
  • This paper considers acoustic analysis of silencer within a Dry vacuum pump. Main object is noise reduction of Dry Vacuum Pump using the silencer. First, we measured SPL and Intensity for noise source identification and then, designed for the silencer corresponding with noise character. 4-pole parameter are used for predicting transmission loss which is one of characteristics of silencer when we designed for silencer. Calculated Transmission Loss to change main effective factor and selected to optimal value using Design of Experiment. Finally, noise reduction is estimated to compare existing silencer with optimal silencer.

  • PDF

Improvement of Sound Insulation at Low Frequencies Using Resilient Channel (탄성채널을 이용한 석고보드 건식벽체의 저주파 대역 차음성능 개선)

  • Kim, Kyung Ho;Jeon, Jin Yong
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.27 no.1
    • /
    • pp.94-99
    • /
    • 2017
  • Breaking the rigid connection between the two faces of the wall can significantly improve the sound transmission loss of the wall. This is usually achieved by resiliently mounting the gypsum board on one of the two faces of the wall using resilient channel. Resilient channel with less stiffness than that of air cavity could move the resonance frequency of the light-weight wall. So we can get higher sound transmission loss at low frequencies for light-weight wall using resilient channel. It's sound transmission loss is 17 dB higher than that of single stud wall, and 5 dB higher than that of double stud wall.