• Title/Summary/Keyword: Transmission rate

Search Result 3,608, Processing Time 0.03 seconds

The Performance Improvement of PLC by Using RTP Extension Header Data for Consecutive Frame Loss Condition in CELP Type Vocoder (CELP Type Vocoder에서 RTP 확장 헤더 데이터를 이용한 연속적인 프레임 손실에 대한 PLC 성능개선)

  • Hong, Seong-Hoon;Bae, Myung-Jin
    • The Journal of the Acoustical Society of Korea
    • /
    • v.29 no.1
    • /
    • pp.48-55
    • /
    • 2010
  • It has a falling off in speech quality, especially when consecutive packet loss occurs, even if a vocoder implemented in the packet network has its own packet loss concealment (PLC) algorithm. PLC algorithm is divided into transmitter and receiver algorithm. Algorithm in the transmitter gives superior quality by additional information. however it is impossible to provide mutual compatibility and it occurs extra delay and transmission rate. The method applied in the receiver does not require additional delay. However, it sets limits to improve the speech quality. In this paper, we propose a new method that puts extra information for PLC in a part of Extension Header Data which is not used in RTP Header. It can solve the problem and obtain enhanced speech quality. There is no extra delay occurred by the proposed algorithm because there is a jitter buffer to adjust network delay in a receiver. Extra information, 16 bits each frame for G.729 PLC, is allocated for MA filter index in LP synthesis, excitation signal, excitation signal gain and residual gain reconstruction. It is because a transmitter sends speech data each 20 ms when it transfers RTP payload. As a result, the proposed method shows superior performance about 13.5%.

Bovine mastitis-associated Escherichia coli

  • Hong Qui Le;Se Kye Kim;Jang Won Yoon
    • Journal of Food Hygiene and Safety
    • /
    • v.39 no.3
    • /
    • pp.181-190
    • /
    • 2024
  • Bovine mastitis-associated Escherichia coli (BMEC) is considered the main causative agent of significant financial losses in the dairy industry worldwide, as it alters both the quantity and quality of milk produced and increases the rate of culling. This creates a variety of challenges for researchers, veterinarians, and farmers in understanding and determining the most effective therapies and diagnostic techniques. Subclinical mastitis is particularly concerning, as infected bovines exhibit no obvious symptoms and continue to secrete apparently normal milk over an extended period, allowing the causative pathogen, E. coli, to spread within the herd. For effective prevention, understanding the pathogenesis of mastitis through three stages invasion, infection, and inflammation is essential. To date, no clear correlation has been found between virulence factors and pathogenicity contributing to the clinical severity of BMEC. Multidrug-resistant E. coli and the evolution of novel resistance mechanisms have become concerns owing to the extensive use of antibiotics to treat mastitis. Therefore, it is vital to explore alternative controls to enhance the efficacy of BMEC treatment. Over the past 30 years, various genetic typing techniques have been used to examine the subspecies-level epidemiology of bovine mastitis. These studies have advanced our understanding of the origin, transmission pathway, population structure, and evolutionary relatedness of BMEC strains. In this review we provide an overview of BMEC, including insights into its etiology, genetic relationship, pathogenesis, and management of the disease, as well as new therapy options.

A Pilot Research for Real-Time Specific Patient Quality Assurance Using the Hybrid Optimized Vmat Phantom (Hovp) in Volume Modulated Arc Therapy (체적변조회전치료에서 Hybrid Optimized VMAT Phantom (HOVP)을 이용한 실시간 환자 맞춤형 정도관리를 위한 예비연구)

  • Huh, Hyun-Do;Choi, Sang-Hyoun;Kim, Woo-Chul;Kim, Hun-Jeong;Kim, Kum-Bae;Kim, Seong-Hoon;Cho, Sam-Ju;Min, Chul-Kee;Cho, Kwang-Hwan;Lee, Sang-Hoon;Lee, Suk;Shim, Jang-Bo;Shin, Dong-Oh;Ji, Young-Hoon
    • Progress in Medical Physics
    • /
    • v.22 no.4
    • /
    • pp.206-215
    • /
    • 2011
  • The purpose of this was to investigate the measurement of fluence dose map for the specific patient quality assurance. The measurement of fluence map was performed using 2D matrixx detector. The absorbed dose was measured by a glass detector, Gafchromic film and ion chamber in Hybrid Optimized VMAT Phantom (HOVP). For 2D Matrixx, the results of comparison were average passing rate $85.22%{\pm}1.7$ (RT_Target), $89.96%{\pm}2.15$ (LT_Target) and $95.14%{\pm}1.18$ (G4). The dose difference was $11.72%{\pm}0.531$, $-11.47%{\pm}0.991$, $7.81%{\pm}0.857$, $-4.14%{\pm}0.761$ at the G1, G2, G3, G4. In HOVP, the results of comparison for film were average passing rate (3%, 3 mm) $93.64%{\pm}3.87$, $90.82%{\pm}0.99$. We were measured an absolute dose in steep gradient area G1, G2, G3, G4 using the glass detector. The difference between the measurement and calculation are 8.3% (G1), -5.4% (G2), 6.1% (G3), 7.2% (G4). The using an Ion-chamber were an average relative dose error $-1.02%{\pm}0.222$ (Rt_target), $0.96%{\pm}0.294$ (Lt_target). Though we need a more study using a transmission detector. However, a measurement of real-time fluence map will be predicting a dose for real-time specific patient quality assurance in volume modulated arc therapy.

Properties of Organic-Inorganic Protective Films on Flexible Plastic Substrates by Spray Coating Method (연성 플라스틱 기판위에 스프레이 코팅방법으로 제조한 유·무기 보호막의 특성)

  • Lee, Sang Hee;Chang, Ho Jung
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.24 no.4
    • /
    • pp.79-84
    • /
    • 2017
  • The solar cells should be protected from the moisture and oxygen in order to sustain the properties and reliability of the devices. In this research, we prepared the protection films on the flexible plastic substrates by spray coating method using organic-inorganic hybrid solutions. The protection characteristics were studied depending on the various process conditions (nozzle distance, thicknesses of the coatings, film structures). The organic-inorganic solutions for the protection film layer were synthesized by addition of $Al_2O_3$ ($P.S+Al_2O_3$) and $SiO_2$ ($P.S+SiO_2$) nano-powders into PVA (polyvinyl alcohol) and SA (sodium alginate) (P.S) organic solution. The optical transmittances of the protection film with the thicknesses of $5{\mu}m$ showed 91%. The optical transmittance decreased from 81.6% to 73.6% with the film thickness increased from $78{\mu}m$ to $178{\mu}m$. In addition, the protective films were prepared on the PEN (polyethylene naphthalate), PC (polycarbonate) single plastic substrates as well as the Acrylate film coated on PC substrate (Acrylate film/PC double layer), and $Al_2O_3$ film coated on PEN substrate ($Al_2O_3$ film/PEN double layer) using the $P.S+Al_2O_3$ organic-inorganic hybrid solutions. The optimum protection film structure was studied by means of the measurements of water vapor transmittance rate (WVTR) and surface morphology. The protective film on PEN/$Al_2O_3$ double layer substrate showed the best water protective property, indicating the WVTR value of $0.004gm/m^2-day$.

Epidemiologic Investigation for the Etiology of an Epidemic Ocurred among Animals and Humans in an Isolated Island, Korea(I) (신안군(新安郡) 낙도(落島)에서 발생(發生)한 괴질(怪疾)의 원인(原因)에 관한 역학적(疫學的) 조사(調査)(I))

  • Kim, J.S.;Heo, Y.;Yoon, H.Y.;Lee, W.Y.
    • Journal of Preventive Medicine and Public Health
    • /
    • v.22 no.2 s.26
    • /
    • pp.290-301
    • /
    • 1989
  • This is preliminary report on anthrax epidemic occurred in an island with about 100 residents. Since 1982 there had been sudden deaths among all kinds of domestic animals including cattle, dogs, ducks, chicken and goat but only a few among cats in an isolated island about three hours distance away by ferry boat from Mokpo city. From 1986 through 1988 nine human deaths and four patients occurred, which made the government intervene for investigation on June 25 1988. The epidemiological investigation consisted of interview survey and medical examination, medical record analysis, laboratory work to isolate the pathogens under the direction of hypothesis derived from the study and further confirmation of the pathogens by international institute. The summarized results are as followings: 1. According to the interview survey there were many deaths among domestic animals usually in cold and dry season such as January through March and September through November; 36 heads of cattle leaving one head, more than 40 hogs(all), hundreds of chicken leaving few alive, goats that had taken home from mountain and two or three cats out of around 40 had sudden deaths from 1982 till 1985, when the residents stopped to purchase and take them into the island anymore. Also there were eleven persons who had experienced the similar syndrome complex to those of admitted and expired patients and four of them revealed typical chest X-ray findings; from one of these four patients(Rho) B. anthracis is isolated. 2. Medical record on patients who had been admitted, showed common characteristics of the disease course. On admission they had either gastrointestinal or upper respiratory infection symptoms which invariably progressed to septicemic nature with pulmonary interstitial infiltration and mediastinal widening/bulging, and then to deadly acute respiratory distress syndrome. At the end stage chest X-ray revealed multiple bullous emphysema. One of another characteristics was oral ulceration with bleeding occurred in about 50% of the patients. Laboratory test results in common were leukocytosis with left shift and abnormal liver and kidney functions, particularly at the later stage of the illness. 3. Epidemiological characteristics was striking in that both mortality and incidence rates were high: the mortality rate was 8.7% average, male being three times higher than females but there was no distictive clustering by age group. The incidence rate for both sexes was 28.2% and there was no sex difference although a tendency of higher incidence among older ages was noticed. The highest mortality and incidence were observed in Won village where the first death of animal occurred and with the highest frequency among three villages of the island. 4. Among twelve bacilli species isolated from various specimens, two strains, one from patient and the other from soil where the recently died cow is hurried, were confirmed as B. anthracis by Pasteur Institute and CDC of USA(strain from soil). CDC reported that the strain did not produce capsule in bicarbonate media but reacted with the bacteriophage and one of five sera taken from the patients. Mode of transmission as well as incubation period of the agent has not been established yet, which needs further investigation in relation to the antigenic structure of the variant when it is confirmed.

  • PDF

Improvement of Shelf-life and Quality in Fresh-Cut Tomato Slices:

  • Hong Ji Heun
    • Proceedings of the Korean Society of Postharvest Science and Technology of Agricultural Products Conference
    • /
    • 2004.10a
    • /
    • pp.67-72
    • /
    • 2004
  • Quality of fresh-cut tomato slices was compared during cold storage under various modified atmosphere packaging conditions. Chilling injury of slices in containers sealed with Film A was higher than with Film B; these films had oxygen transmission rates of 87.4 and 60.0 ml $h^{-1}\;m^{-2}\;atm^{-1}$ at $5^{\circ}C\;and\;99\%$ RH, respectively. While slices in containers with an initial atmospheric composition of air, $4\%\;CO_2+1\;or\;20\%\;O_2,\;8\%\;CO_2+1\;or\;20\%\;O_2,\;or\;12\%\;CO_2+20\%\;O_2$ showed fungal growth, slices in containers with $12\%\;CO_2+1\%\;O_2$ did not. Low ethylene in containers enhanced chilling injury. Modified atmosphere packaging provided good quality tomato slices with a shelf-life of 2 weeks or more at $5^{\circ}C$. Experiments were conducted to compare changes in quality of slices of red tomato (Lycopersicon esculentum Mill. 'Sunbeam') fruit from plants grown using black polyethylene or hairy vetch mulches under various foliar disease management systems including: no fungicide applications (NF), a disease forecasting model (Tom-Cast), and weekly fungicide applications (WF), during storage at $5^{\circ}C$ under a modified atmosphere. Slices were analyzed for firmness, soluble solids content (SSC), titratable acidity (TA), pH, electrolyte leakage, fungi, yeasts, and chilling injury. With both NF and Tom-Cast fungicide treatments, slices from tomato fruit grown with hairy vetch (Vicia villosa Roth) mulch were firmer than those from tomato fruit grown with black polyethylene mulch after 12 days storage. Ethylene production of slices from fruit grown using hairy vetch mulch under Tom-Cast was about 1.5- and 5-fold higher than that of slices from WF and NF fungicide treatments after 12 days, respectively. The percentage of water-soaked areas (chilling injury) for slices from tomato fruit grown using black polyethylene mulch under NF was over 7-fold that of slices from tomato fruit grown using hairy vetch under Tom-Cast. When stored at $20^{\circ}C$, slices from light-red tomato fruit grown with black polyethylene or hairy vetch mulches both showed a rapid increase in electrolyte leakage beginning 6 hours after slicing. However, slices from tomato fruit grown using the hairy vetch mulch tended to have lower electrolyte leakage than those grown with black polyethylene mulch. These results suggest that tomato fruit from plants grown using hairy vetch mulch may be more suitable for fresh-cut slices than those grown using black polyethylene mulch. Also, use of the disease forecasting model Tom-Cast, which can result in lower fungicide application than is currently used commercially, resulted in high quality fruit for fresh-cut processing. Experiments were conducted to determine if ethylene influences chilling injury, as measured by percentage of slices exhibiting water-soaked areas in fresh-cut tomato slices of 'Mountain Pride' and 'Sunbeam' tomato (Lycopersicon esculentum Mill.). Ethylene concentration in containers without ventilation significantly increased during storage at $5^{\circ}C$, whereas little or no accumulation of ethylene occurred in containers with one or six perforations. Chilling injury was greatest for slices in containers with six perforations, compared to slices in containers with one perforation, and was over 13-fold greater than that of slices in control containers with no perforations. An experiment was also performed to investigate the effectiveness of including an ethylene absorbent pad in containers on subsequent ethylene accumulation and chilling injury. While ethylene in the no-pad controls increased continually during storage of both 'Mountain Pride' and 'Sunbeam' tomatoes at $5^{\circ}C$ under modified atmosphere conditions, no increase in accumulation of ethylene was observed in containers containing ethylene absorbent pads throughout storage. The ethylene absorbent pad treatment resulted in a significantly higher percentage of chilling injury compared with the no-pad control. In studies aimed at inhibiting ethylene production using AVG during storage of slices, the concentration of ethylene in control containers (no AVG) remained at elevated levels throughout storage, compared to containers with slices treated with AVG. Chilling injury in slices treated with AVG was 5-fold greater than that of controls. Further, we tested the effect of ethylene pretreatment of slices on subsequent slice shelf-life and quality. In slices treated with ethylene (0, 0.1, 1, or $10\;{mu}L\;L^{-1}$) immediately after slicing, ethylene production in non-treated controls was greater than that of all other ethylene pre-treatments. However, pretreatment of slices 3 days after slicing resulted in a different pattern of ethylene production during storage. Ihe rate of ethylene production by slices treated with 1 L $L^{-1}$ ethylene 3 days after slicing was greater during storage than any of the other ethylene treatments. With slices pre-treated with ethylene, both immediately and 3 days after slicing, the rate of ethylene production tended to show an negative correlation with chilling injury. Chemical name used: 1-aminoethoxyvinylglycine (AVG).

  • PDF

The Dose Attenuation according to the Gantry Angle and the Photon Energy Using the Standard Exact Couch and the 6D Robotic Couch (Standard Exact Couch와 6D Robotic Couch를 이용한 광자선의 조사각에 따른 선량 감쇠에 대한 연구)

  • Kim, Tae Hyeong;Oh, Se An;Yea, Ji Woon;Park, Jae Won;Kim, Sung Kyu
    • Progress in Medical Physics
    • /
    • v.27 no.2
    • /
    • pp.79-85
    • /
    • 2016
  • The objective of this study is to increase the accuracy of dose transmission in radiation therapy using two types of treatment tables, standard exact couch (Varian 21EX, Varian Medical Systems, Milpitas, CA) and 6D robotic couch (Novalis, BrainLAB A.G., Heimstetten, Germany)). We examined the dose attenuation based on the two types of treatment tables and studied the dose of attenuation using the phase (In/Out) for the standard exact couch. We measured the relative dose according to the incident angle of a penetrative photon beam under a treatment table. The incident angle of the photon beam was from $0^{\circ}$ to $360^{\circ}$ in the increments of $5^{\circ}$. The reference angle was set to $0^{\circ}$. Furthermore, the relative dose of the 6D robotic couch was measured using 6 MV and 15 MV, and that of the standard exact couch was measured at the sliding rail position (In-Out) using 6 MV and 10 MV. In the case of the standard exact couch, the measured relative dose was 16.53% (rails at the "In position," $175^{\circ}$, 6 MV), 12.42% (rails at the "In position," $175^{\circ}$, 10 MV), 13.13% (rails at the "Out position," $175^{\circ}$, 6 MV), and 9.96% (rails at the "Out position," $175^{\circ}$, 10 MV). In the case of the 6D robotic couch, the measured relative dose was 6.82% ($130^{\circ}$, 6 MV) and 4.92% ($130^{\circ}$, 15 MV). The photon energies were surveyed at the same incident angle. The dose attenuation for an energy of 10 MV was 4~5% lower than that for 6 MV. This indicated that the higher photon energy, lesser is the attenuation. The results of this study indicated that the attenuation rate for the 6D robotic couch was confirmed to be 1% larger than that for the standard exact couch at 6 MV and $180^{\circ}$. In the case of the standard exact couch, the dose attenuation was found to change rapidly in accordance with the phase ("In position" and "Out position") of the sliding rail.

Novel LTE based Channel Estimation Scheme for V2V Environment (LTE 기반 V2V 환경에서 새로운 채널 추정 기법)

  • Chu, Myeonghun;Moon, Sangmi;Kwon, Soonho;Lee, Jihye;Bae, Sara;Kim, Hanjong;Kim, Cheolsung;Kim, Daejin;Hwang, Intae
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.54 no.3
    • /
    • pp.3-9
    • /
    • 2017
  • Recently, in 3rd Generation Partnership Project(3GPP), there is a study of the Long Term Evolution(LTE) based vehicle communication which has been actively conducted to provide a transport efficiency, telematics and infortainment. Because the vehicle communication is closely related to the safety, it requires a reliable communication. Because vehicle speed is very fast, unlike the movement of the user, radio channel is rapidly changed and generate a number of problems such as transmission quality degradation. Therefore, we have to continuously updates the channel estimates. There are five types of conventional channel estimation scheme. Least Square(LS) is obtained by pilot symbol which is known to transmitter and receiver. Decision Directed Channel Estimation(DDCE) scheme uses the data signal for channel estimation. Constructed Data Pilot(CDP) scheme uses the correlation characteristic between adjacent two data symbols. Spectral Temporal Averaging(STA) scheme uses the frequency-time domain average of the channel. Smoothing scheme reduces the peak error value of data decision. In this paper, we propose the novel channel estimation scheme in LTE based Vehicle-to-Vehicle(V2V) environment. In our Hybrid Reliable Channel Estimation(HRCE) scheme, DDCE and Smoothing schemes are combined and finally the Linear Minimum Mean Square Error(LMMSE) scheme is applied to minimize the channel estimation error. Therefore it is possible to detect the reliable data. In simulation results, overall performance can be improved in terms of Normalized Mean Square Error(NMSE) and Bit Error Rate(BER).

The Immune Response and Protective Efficacy of Hepatitis B Vaccine in Neonates Born from Hepatitis B Carrier Mothers (B형 간염 바이러스 보유 산모로부터 분만된 신생아의 B형 간염 백신의 면역반응 및 방어효과)

  • Kim, Jong-Hyun;Kang, Jin-Han;Hur, Jae-Kyun;Koh, Dae-Kyun;Oh, Chang-Kyu
    • Pediatric Infection and Vaccine
    • /
    • v.5 no.1
    • /
    • pp.96-103
    • /
    • 1998
  • Purpose : We performed this study to evaluate the immune responses and protective efficacies of the HBV vaccine in infants born from hepatitis B virus(HBV) carrier mothers. Methods : Seventy eight infants born from HBV carrier mothers, who were able to follow up for 12months in the Catholic University St. Vincents hospital, were involved in this study from July 1995 to December 1996. Samples were collected at birth, 4, 8 and 12months after injection of HBIG and HBV heat-inactivated plasma derived vaccines. We evaluated the changes and relationships of viral markers detecting by enzyme immunoassay and radioimmunoassay between HBV carrier mothers and their infants. Results : 1) A total of 5.0%(106/2,117) of pregnant women were found to be a HBV carrier. The rates of HBeAg positive and negative were 38.5%(37/96) and 61.5%(59/96), respectively. 2) The seroconversion rates of anti-HBs with infants of HBV carrier mothers at 4, 8 and 12 months were 85.9%(67/78), 75.6%(59/78) and 73.1%(57/78), respectively. Although these were statistically significant differences(P<0.05), they were not related to HBeAg status of the mothers. The geometric mean titers of anti-HBs at 8 and 12 months were significantly higher than at 4 months, statistically(P<0.05). The protective efficacy of the HBV vaccine and HBIG at 12 months in infants from HBeAg positive and negative mothers were 89.8% and 100%, respectively. 3) Five of 78(6.4%) infants became infected by HBV from only HBeAg positive mothers during the follow up period of 12 months. Three of 5 infected infants became HBV carriers. HBsAg positive at birth from HBeAg positive and negative mother were 4 infants, respectively. Three of 4 infants became infected by HBV from only HBeAg positive mothers. Conclusion : We confirmed that the seroconversion rate of HBV heat-inactivated plasma derived vaccine which was one of other vaccines manufacturing in Korea was 85.9%. The protective efficacy of this HBV vaccine and HBIG at 12 months in infants from HBeAg positive and negative mothers were 89.8% and 100%, respectively.

  • PDF

Performance of Direct Seeded Rice in Ridged Dry Soil at Different Seeding Methods and Seeding Rates (벼 건답휴립직파재배에서 파종양식과 파종량에 따른 생육과 수량)

  • 이석순;백준호;김태주
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.37 no.6
    • /
    • pp.514-520
    • /
    • 1992
  • Performance of direct seeded paddy rice in ridged dry soil was evaluated at different seeding methods (broadcasting, drilling, and seeding in group) and seeding rates (4, 6, and 8kg /10a). The number of maximum tillers at broadcasting and drilling of seeds was higher than that at seeding in group. At broadcasing and drilling the number of maximum tillers at seeding rate of 6kg /10a was greater than that at 4 or 8kg /10a, but at seeding in group the number of maximum tillers increased with seeding rates. Among the seeding methods there were no differences in the number of seedlings per unit area, culm and panicle lengths, and productive tiller ratio, but heading date at seeding in group was delayed by a day compared with broadcasting or drilling. At heading stage leaf area index(LAI) and dry matter production at broadcasting of seeds were higher compared with drilling and seeding in group, but light transmission ratio at drilling and seeding in group was higher than that at broadcasting of seeds. Although the number of seedlings increased with seeding rates, LAI and dry matter production at heading stage, culm and panicle lengths, and productive tiller ratio were not different among the seeding rates. There were no differences in the number of panicles and spikelets per unit area, 1,000 grain weight, yield, and harvest index among the seeding methods. The number of spikelets per panicle at seeding in group was higher, but percent ripened grains was lower compared with broadcasting and drilling. There were no significant differences in the number of panicles and spikelets per panicle and unit area, percent ripened grains, and harvest index among the seeding rates, but yield at seeding rate of 6kg /10a was higher than at 4 or 8kg /10a. There were no significant differences in tiller length, bending moment, and fresh weight of tiller among the seeding methods. Breaking strength was lower in the order of seeding in group, drilling, and broadcasting of seeds. However, lodging index was similar among the seeding rates and lodging was not occurred in the field. There was a significant interaction in the cellulose, hemicellulose, and lignin contents of culm base between seeding methods and seeding rates.

  • PDF