SHD Digital Cinema Distribution over a Fast Long-Distance Network

  • Takahiro Yamaguchi;Daisuke Shirai;Mitsuru Nomura;Kazuhiro Shirakawa;Tatsuya Fujii;Tetsuro Fujii;Kim, io-Oguchi
    • 방송공학회논문지
    • /
    • 제9권2호
    • /
    • pp.119-130
    • /
    • 2004
  • We have developed a prototype super-high-definition (SHD) digital cinema distribution system that can store, transmit, and display eight-million-pixel motion pictures that have the image quality of a 35-mm film movie. The system contains a movie server, a real-time decoder, and an SHB projector. Using a Gigabit Ethernet link and TCP/IP, the server transmits JPEG2000 compressed motion picture data streams to the decoder at transmission speeds as high as 300 Mbps. The received data streams are decompressed by the decoder, and then projected onto a screen via the projector. By using an enlarged TCP window, multiple TCP streams, and a shaping function to control the data transmission quantity, we achieved real-time streaming of SHD movie data at about 300 Mbps between Chicago and Los Angeles, a distance of more than 3000 km. We also improved the decoder performance to show movies with Image qualities of 450 Mbps or higher. Since UDP is more suitable than TCP for fast long-distance streaming, we have developed an SHD digital cinema UDP relay system, in which UDP is used for transmission over a fast long-distance network. By using four pairs of server-side-proxy and decoder-side-proxy, 450-Mbps movie data streams could be transmitted.

Transmission Characteristics in LonWorks/IP-based Virtual Device Network (II)

  • Park, Gi-Heung;Song, Ki-Won;Kim, Jong-Hwi;Park, Gi-Sang
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2002년도 ICCAS
    • /
    • pp.121.6-121
    • /
    • 2002
  • Web-based virtual machine/manufacturing system (VMS) utilizes Virtual Device Network (VDN.) VDN inevitably involves the implementation of Distributed Monitoring and Control Networks (DMCN). In general, one needs to integrate device (control) network and IP network to realize DMCN over IP network or internet, which can be viewed as a VDN. In this study, LonWorks networking technology is used for device network and the transmission characteristics of LonWorks/IP-based VDN is investigated. A method to minimize the transmission delay in the LonWorks/IP networks is also suggested.

  • PDF

IEEE 802.15.4기반의 제어용 무선 네트워크에 대한 연구 (Wireless Networked Control Systems Using IEEE 802.15.4)

  • Lee, Jung-Il;Choi, Dong-Hyuk;Kim, Dong-Sung
    • 한국지능시스템학회:학술대회논문집
    • /
    • 한국퍼지및지능시스템학회 2006년도 추계학술대회 학술발표 논문집 제16권 제2호
    • /
    • pp.289-292
    • /
    • 2006
  • In this paper, a wireless control network based on IEEE 802.15.4 MAC protocol is proposed. The superframe of IEEE 802.15.4 is applied to the proposed wireless control network. The transmission and bandwidth management method are proposed for efficient transmission in the superframe. By these methods, the proposed wireless control network protocol is able to transmit three types of data (periodic data, sporadic data, and non real-time message), and guarantee real-time transmission within deadline.

  • PDF

효율적인 전송을 위한 액티브 광 링네트워크 시스템의 성능 분석 (Performance Analysis of Active Optical Ring Network System for the Efficient Transmission)

  • 이상화
    • 한국콘텐츠학회논문지
    • /
    • 제6권7호
    • /
    • pp.69-78
    • /
    • 2006
  • 본 논문에서는 네트워크 물리층이 광소자들로 구성된 액티브 광 링네트워크 시스템에서의 전송 능력과 그에 따른 효율성에 관하여 기술한다. 실험을 위한 시뮬레이션은 광 전송 시스템에서 광 전송 품질을 측정 할 수 있는 트랜스미션메이커 WDM(Transmissionmaker WDM)이 사용되었다. 광액티브 네트워크는 메인링과 서브링에 의한 두 개의 링으로 구성되었다. 서브링의 노드 개수와 각 노드들 간의 간격에 따른 비트 에러율 (Bit Error Rate)의 특성을 측정한다. 이러한 물리층에서의 성능 분석은 액티브 광 링네트워크의 성능 최적화를 위한 설계의 기준이 된다. 따라서 궁극적으로는 실제 가입자망에서 각 노드의 물리적 거리, 트래픽 요구량, 가입자 수를 반영한 효율적인 광전송 시스템을 구성할 수 있다.

  • PDF

레이저 장비의 전송 경로 자가 교정을 위한 무선 네트워크 시스템 (Wireless Networked System for Transmission Path Self-Calibration of Laser Equipment)

  • 이준영;유성은
    • 대한임베디드공학회논문지
    • /
    • 제15권2호
    • /
    • pp.79-85
    • /
    • 2020
  • IIoT stands for Industrial Internet of Things used in manufacturing, healthcare, and transportation in networked smart factories. Recently, IIoT's environment requires an automated control system through intelligent cognition to improve efficiency. In particular, IIoT can be applied to automatic calibration of production equipment for improved management in industrial environments. Such automation systems require a wireless network for transmitting industrial data. Self-calibration systems in laser transmission paths using wireless networks can save resources and improve production quality by real-time monitoring and remote control of laser transmission path. In this paper, we propose a wireless networked system for self-calibration of laser equipment that requires a laser transmission path, and we show the results of the prototype evaluation. The self-calibration system of laser equipment measures the coordinates of the laser points with sensors and sends them to the host using the proposed application protocol. We propose a wireless network service for the wired motor controller to align the laser coordinates. Using this wireless network, the host controls the motor by sending a control command of the motor controller in an HTTP message based on the received coordinate values. Finally, we build a prototype system of the proposed design to verify the detection performance and analyze the network performance.

신재생에너지 계통 연계에 따른 송전망 Risk Level 평가에 대한 연구 (A Study on Evaluation for Risk Level in Transmission Network Connected with Renewable Energy)

  • 김성열;문상근;김진오
    • 조명전기설비학회논문지
    • /
    • 제25권2호
    • /
    • pp.87-95
    • /
    • 2011
  • A Renewable Portfolio Standard(RPS) is a regulation that requires the increased generation of energy from renewable energy sources such as solar, wind, fuel cell, small hydro, biomass and geothermal. By environmental, technical and these regulatory reasons, the amount of renewable energy sources will be increased in a network. However, it is hard to assess risk of a transmission network with large scale renewable energy sources because the output characteristics of renewable energies are intermittent. This paper evaluates effects of a transmission system with supplemental large scale renewable energies into the existing system. To evaluate these effects, a methodology for risk level of components in a network is proposed considering steady state and contingency N-1 in this paper. We consider line current and bus voltage in each state of a network.

제주계통에서 동기조상기 기동에 따른 전압안정도 영향 검토 (Analysis of Impact on Voltage Stability by Starting Synchronous Condenser in Jeju AC Network)

  • 최순호;이성두;김찬기
    • 전기학회논문지
    • /
    • 제64권1호
    • /
    • pp.23-28
    • /
    • 2015
  • Two old synchronous condensers in Jeju are being replaced by new machines to operate Jeju AC network with Haenam-Jeju HVDC system stably. Before new synchronous condensers operate on site, voltage stability analysis is conducted to verify stable operation of jeju AC network. Through impedance analysis of the synchronous machine, transformer and ac network, the equivalent circuit is constructed and the voltage drop during start-up is calculated. Then, PSS/E fault analysis is performed to acquire short-circuit capacity according to the generator operation scenarios. Voltage variation when starting synchronous condenser is simulated in PSCAD/EMTDC and satisfies the operating condition of jeju AC network and HVDC #1 system.

PHS를 이용한 열차정보 전송 방안 (Method for Train Information Transmission using PHS)

  • 조봉관
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.240-241
    • /
    • 2004
  • JP Nagoya. Inc started special work(passenger order} to transmit information to the passenger from 2001 following the eastern area' heavy rain in 2000. They introduced 'Passenger Information System' which uses self communication network(LAN, PHS) mainly and wire/wireless and internet jointly. As an information transmission method of this system, there is "train information transmission using PHS" which transmits info to LED display in special train. This system configured by adding new equipments and using existing equipments, network in maximum, this study reviewed the system, which transmits real time operation condition unified by these passenger order to passenger in high quality, more promptly.

  • PDF

A Novel Algorithm for Fault Classification in Transmission Lines Using a Combined Adaptive Network and Fuzzy Inference System

  • Yeo, Sang-Min;Kim, Chun-Hwan
    • KIEE International Transactions on Power Engineering
    • /
    • 제3A권4호
    • /
    • pp.191-197
    • /
    • 2003
  • Accurate detection and classification of faults on transmission lines is vitally important. In this respect, many different types of faults occur, such as inter alia low impedance faults (LIF) and high impedance faults (HIF). The latter in particular pose difficulties for the commonly employed conventional overcurrent and distance relays, and if undetected, can cause damage to expensive equipment, threaten life and cause fire hazards. Although HIFs are far less common than LIFs, it is imperative that any protection device should be able to satisfactorily deal with both HIFs and LIFs. Because of the randomness and asymmetric characteristics of HIFs, their modeling is difficult and numerous papers relating to various HIF models have been published. In this paper, the model of HIFs in transmission lines is accomplished using the characteristics of a ZnO arrester, which is then implemented within the overall transmission system model based on the electromagnetic transients program (EMTP). This paper proposes an algorithm for fault detection and classification for both LIFs and HIFs using Adaptive Network-based Fuzzy Inference System (ANFIS). The inputs into ANFIS are current signals only based on Root-Mean-Square (RMS) values of 3-phase currents and zero sequence current. The performance of the proposed algorithm is tested on a typical 154 kV Korean transmission line system under various fault conditions. Test results demonstrate that the ANFIS can detect and classify faults including LIFs and HIFs accurately within half a cycle.

전력용 보호제어정보의 ATM전송조건 모델링에 관한 연구 (A Study on the Transmission Constraints Modeling of Carrier Relay Signal over ATM network)

  • 이재조;윤일환;유재택;이원태;허영;김관호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 추계학술대회 논문집 학회본부
    • /
    • pp.584-587
    • /
    • 1997
  • In this paper, we present a transmission constraints modeling of carrier relay signal over ATM network. Since teleprotection system, which is used for protecting power transmission lines using telecommunications, has strict transmission delay constraints, it is a important problem to transmit teleprotection signals in future utilities' ATM networks when utilites' communications are integrated. Therefore, we considered the transmission constraints of carrier relay signal over ATM network and the transmission model system.