• 제목/요약/키워드: Transmission line analysis

검색결과 901건 처리시간 0.03초

송전선로 DC화에 따른 융통조류 마진 분석 (Analysis of system power flow margin on replacement of transmission line to DC line)

  • 황성철;이재형;황평익;윤민한;장길수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2015년도 제46회 하계학술대회
    • /
    • pp.420-421
    • /
    • 2015
  • Recently construction of new transmission line is getting harder because of social hostility to transmission tower. Howevere, load is converged in metropolitan area and power plants near this area are old and life of generator will end soon. Therefore, power to supply load in this area should be transmitted from east coast area and southern area. For these reasons, securement of transmission capacity without new transmission line construction is important. In this paper, effect of one circuit AC line change to DC transmission at the same transmission tower on the system available transfer capacity is analyzed.

  • PDF

백 플레인의 개구를 통과하는 길이가 다른 전송 선로의 삽입 손실 특성 (Characteristics of Insertion Loss of Transmission Line with Different Line Length Crossing a Rectangular Aperture in a Backplane)

  • 정성우;김기채
    • 한국전자파학회논문지
    • /
    • 제19권2호
    • /
    • pp.237-243
    • /
    • 2008
  • 본 논문에서는 무한히 넓은 백 플레인의 사각형 개구를 관통하는 길이가 다른 평행 2선 전송 선로에 대하여 백 플레인의 존재가 전송 선로에 미치는 영향을 검토하였다. 이론 해석에는 FDTD법을 사용하였으며, 길이가 다른 구조를 가지게 하는 부가 선로의 길이와 전송 선로의 간격 변화에 따른 반사 손실 및 삽입 손실 특성을 계산하여 백 플레인이 전송 선로에 미치는 영향을 고찰하였다. 그 결과, 전송 선로의 간격이 좁은 경우에는 부하 측의 전송 선로가 안테나처럼 동작하여 삽입 이득 특성이 나타나고, 부가 선로의 길이가 길어지면 백 플레인에 의한 삽입 손실 특성이 현저히 나타남을 확인할 수 있었다. 반사 손실을 측정하고 수치 계산 결과와 비교하여 이론 해석의 타당성도 확인하였다.

지중송전 및 배전계통에서 알루미늄 도체 선로운용의 실용성 평가 (Evaluation of Operation Practicality on Line with Aluminum Conductor in Underground T&D Systems)

  • 장주영;이종범;김용갑
    • 전기학회논문지
    • /
    • 제60권3호
    • /
    • pp.492-499
    • /
    • 2011
  • This paper describes that the evaluation on operation practicality of Al conductor cable will be used instead of Cu conductor cable. Analysis is divided into two kinds of cases as transmission and distribution. To evaluate that Al conductor line has the insulation strength indeed safely, various analysis and calculation such as single line-to-ground fault current, lightning surge and allowance current were carried. Model was established based on real combined transmission and distribution is being used in utility with EMTP. The analysis results on Al and Cu conductor line were compared each other. It was proved that Al conductor line can be operated instead of Cu conductor line without special insulation problem in transmission and distribution, in electrical view point such as overvoltage and allowance current.

Response evaluation and vibration control of a transmission tower-line system in mountain areas subjected to cable rupture

  • Chen, Bo;Wu, Jingbo;Ouyang, Yiqin;Yang, Deng
    • Structural Monitoring and Maintenance
    • /
    • 제5권1호
    • /
    • pp.151-171
    • /
    • 2018
  • Transmission tower-line systems are commonly slender and generally possess a small stiffness and low structural damping. They are prone to impulsive excitations induced by cable rupture and may experience strong vibration. Excessive deformation and vibration of a transmission tower-line system subjected to cable rupture may induce a local destruction and even failure event. A little work has yet been carried out to evaluate the performance of transmission tower-line systems in mountain areas subjected to cable rupture. In addition, the control for cable rupture induced vibration of a transmission tower-line system has not been systematically conducted. In this regard, the dynamic response analysis of a transmission tower-line system in mountain areas subjected to cable rupture is conducted. Furthermore, the feasibility of using viscous fluid dampers to suppress the cable rupture-induced vibration is also investigated. The three dimensional (3D) finite element (FE) model of a transmission tower-line system is first established and the mathematical model of a mountain is developed to describe the equivalent scale and configuration of a mountain. The model of a tower-line-mountain system is developed by taking a real transmission tower-line system constructed in China as an example. The mechanical model for the dynamic interaction between the ground and transmission lines is proposed and the mechanical model of a viscous fluid damper is also presented. The equations of motion of the transmission tower-line system subjected to cable rupture without/with viscous fluid dampers are established. The field measurement is carried out to verify the analytical FE model and determine the damping ratios of the example transmission tower-line system. The dynamic analysis of the tower-line system is carried out to investigate structural performance under cable rupture and the validity of the proposed control approach based on viscous fluid dampers is examined. The made observations demonstrate that cable rupture may induce strong structural vibration and the implementation of viscous fluid dampers with optimal parameters can effectively suppress structural responses.

실리콘에 기초한 새로운 크로스바 구조의 손실있는 대칭 결합선로에 대한 유한차분법을 이용한 해석 (Analysis of Symmetric Coupled Line with New Crossbar Embedded on Si-based Lossy Structure using the FDTD Method)

  • Kim, Yoonsuk
    • 한국군사과학기술학회지
    • /
    • 제4권2호
    • /
    • pp.122-129
    • /
    • 2001
  • A characterization procedure for analyzing symmetric coupled MIS(Metal-Insulator-Semiconductor) transmission line is used the same procedure as a general single layer symmetric coupled line with perfect dielectric substrate from the extraction of the characteristic impedance and propagation constant for even- and odd-mode. In this paper, an analysis for a new substrate shielding symmetric coupled MIS structure consisting of grounded crossbar at the interface between Si and SiO2 layer using the Finite- Difference Time-Domain(FDTD) method is presented. In order to reduce the substrate effects on the transmission line characteristics, a shielding structure consisting of grounded crossbar lines over time-domain signal has been examined. Symmetric coupled MIS transmission line parameters for even- and odd-mode are investigated as the functions of frequency, and the extracted distributed frequency- dependent transmission line parameters and corresponding equivalent circuit parameters as well as quality factor for the new MIS crossbar embedded structure are also presented. It is shown that the quality factor of the symmetric coupled transmission line can be improved without significant change in the characteristic impedance and effective dielectric constant.

  • PDF

플라나 마이크로스트립 전송선의 효율적 해석 방법 (An Efficient Analysis Method for Planar Microstrip Transmission Line)

  • 김태원
    • 전자공학회논문지 IE
    • /
    • 제45권2호
    • /
    • pp.13-19
    • /
    • 2008
  • TLM 수치 해석법의 주요한 장점은 가장 복잡한 전송선 구조에 있어서도 해석이 용이하다는 것이다. 본 논문에서는 대칭압축노드를 이용한 TLM법을 마이크로스트립 meander 라인에 성공적으로 적용하였다. 플라나 마이크로스트립 전송선을 모델화하기 위한 대칭압축노드에 대한 상세한 기술이 제시되었고 또한 2종류의 마이크로스트립 meander 라인의 산란 파라메터 $S_{11}$$S_{21}$을 계산하였다. 구해진 결과로부터 TLM 해석법이 복잡한 플라나 마이크로웨이브 전송선 구조를 모델링하는데 유용한 해석법임을 보였다. 제시된 TLM 해석 결과는 고주파 영역에서 마이크로웨이브 집적 회로를 설계하는데 유용하게 사용될 수 있다.

초고속 광전송 시스템용 전송로 부호의 성능 분석 (The Performance Analysis of Transmission Line Codes for the Very-High Speed Optical Transmission System.)

  • 유봉선
    • 한국정보처리학회논문지
    • /
    • 제1권4호
    • /
    • pp.479-489
    • /
    • 1994
  • 정보신호계열을 초고속으로 전송하기 위한 디지틀 광전송 시스템이 대용량화, 경 제화됨에 따라, 효율적으로 순수 정보신호계열을 신뢰성있게 전송할 수 있는 초고속 광전송 시스템용 전송로 부호의 선택이 현시점에서 중요한 문제로 대두되고 있다. 따라서 본 논문에서는 지금 까지 제안된 2치 unipolar 전송로 부호들 중 고속(100Mb/s 이상의 전송속도) 광전송 시스템으로 적합한 전송로 부호들을 우선 선택하여, 선택한 전송로 부호들 간의 성능 평가를 전송로 부호의 요구조건들, 즉 최대 동부호 연속수, 전송지연시간, 클럭 상승률, 마크율, 회로규모, 전송로 에러 감시 및 전력 스펙트럼에 따라 상호 비교 분석 한 결과, mBIZ부호가 최적의 초고속 광전송 시스템용 전송로 부 호임을 밝혔다.

  • PDF

조류에 의한 가공송전선로의 고장분석 및 예방대책 고찰 (The Study for Analysis and Prevention Measure of Overhead Transmission Line Fault with Birds)

  • 정시환;강철원;김완식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.96-98
    • /
    • 2006
  • Recently major power outages are increased, because of transmission line fault by birds. Therefore, after finding out the problem of the current prevention measure for the super high voltage transmission Line in Korea and analyzing the protection measure of other foreign power companies for the transmission facilities fault by birds, this paper describes an effective device for power line fault protection by birds which has no legal problem and also protects birds. The described prevention measure of power outage by birds in this paper, has a special feature that is able to be installed on the current overhead transmission facilities without a replacement or change.

  • PDF

송전 선로의 사고 거리에 따른 특성 주파수 해석 (Analysis of Characteristic Frequency along Fault Distance on a Transmission Line)

  • 남순열;홍정기;강상희;박종근
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제53권8호
    • /
    • pp.432-437
    • /
    • 2004
  • Since the characteristic frequency is decreased in proportion to the fault distance, the characteristic frequency component may be insufficiently eliminated by a low-pass filter on a long transmission line. In order to set a standard for the cut-off frequency of the low-pass filter, this paper proposes a method for obtaining the characteristic frequencies due to line faults. The application results of the proposed method are presented for line to ground (LG) faults and line to line (LL) faults on a 345 kV 200 km overhead transmission line. The EMTP is used to generate fault signals under different fault locations and fault inception angles. By comparison between the characteristic frequencies obtained from the proposed method and the EMTP simulation, it is shown that the proposed method accurately obtains the characteristic frequency.

RLH-TL (Right/left-handed transmission line)을 이용한 8 port 전력 분배기 설계 및 분석 (Design and Analysis of 8-Port Power Divider for Using RLH-TL(Right/Left-Handed Transmission Line))

  • 김형미;이범선
    • 한국전자파학회:학술대회논문집
    • /
    • 한국전자파학회 2005년도 종합학술발표회 논문집 Vol.15 No.1
    • /
    • pp.29-32
    • /
    • 2005
  • 본 논문에서는 right/left-handed특성을 이용한 8 포트 동위상 전력분배기를 제안한다. 이 전력분배기는 사용되는 전송선의 전기적 길이에 상관없이 동위상 분배가 가능하기 때문에 전력 분배기의 크기를 크게 줄일 수 있다. 전력분배기에 사용되는 전송선의 길이가 짧을수록 광대역 특성을 보이며 분배기의 크기는 줄어든다.

  • PDF